Omron E39-L6 Ideal for detecting glass wafers and other transparent object Datasheet

Transparent Object Detection Sensor
E3S-R
CSM_E3S-R_DS_E_5_1
Ideal for Detecting Glass
Wafers and Other Transparent
Objects
• Detects glass wafers and LCD glass circuit boards.
(Compact models with plastic housing only)
Be sure to read Safety Precautions on
page 7.
Ordering Information
Sensors
Compact Models with Plastic Housing (Refer to Dimensions on page 8.)
Red light
Model
Sensing
method
Appearance
Connection
method
Sensing distance
300 mm *1
Pre-wired
(2 m)
[100 mm]
1m
Åñ1*1
Horizontal
[100 mm]
Standard
M12 Connector
300 mm *1
[100 mm]
1m
Åñ1*1
[100 mm]
Retroreflective
300 mm *1
Vertical
Pre-wired
(2 m)
[100 mm]
1m
Åñ1*1
[100 mm]
Standard
M12 Connector
300 mm *1
[100 mm]
1 m *1
[100 mm]
Infrared light
Recommended application *2
Flat object
Cylindrical object
Detecting plastic
Detecting glass wafers
bottles and other
and LCD glass circuit
transparent conboards
tainers
NPN
PNP
E3S-R12 2M
---
Ideal
Ideal
E3S-R11 2M
E3S-R31 2M
Ideal
---
---
Ideal
Ideal
Ideal
---
E3S-R17
E3S-R16
E3S-R36
E3S-R62 2M
---
Ideal
Ideal
E3S-R61 2M
E3S-R81 2M
Ideal
---
---
Ideal
Ideal
Ideal
---
E3S-R67
E3S-R66
E3S-R86
*1. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.
*2. The E3S-R may not detect some glass wafer materials or plastic bottle shapes. Before using the E3S-R, be sure to test it on samples to make sure it can detect the
items reliably.
1
E3S-R
Models with Metal Housing (Refer to Dimensions on page 10.)
Sensing
method
Appearance
Connection
method
Sensing distance
300 mm
Horizontal
1m
Retroreflective
Red light
Model
Recommended application *
Flat object
Cylindrical object
Detecting glass wafers Detecting plastic botand LCD glass circuit
tles and other transboards
parent containers
E3S-RS30E4
---
Ideal
E3S-R1E4
---
Applicable
E3S-RS30E42
---
Ideal
E3S-R1E42
---
Applicable
Pre-wired
Vertical
300 mm
1m
* The E3S-R may not detect some glass wafer materials or plastic bottle shapes. Before using the E3S-R, be sure to test it on samples to make sure it can detect the
items reliably.
Accessories (Order Separately)
Sensitivity Adjuster/Screwdriver (Refer to Dimensions on E39-L/F39-L/E39-S/E39-R.)
Name
Model
Quantity
Remarks
Sensitivity adjuster
E39-G1
1
Provided with the E3S-RS30E4@ and E3S-R1E4@.
Screwdriver for sensitivity
adjustment
E39-G2
1
Provided with the E3S-R1@, E3S-R3@, E3S-R6@, and E3S-R8@.
Reflector (Refer to Dimensions on E39-L/F39-L/E39-S/E39-R.)
Name
Sensing distance
Refer to Ratings and
Specifications.
Reflector
Model
E39-R1
Quantity
1
Remarks
Provided with the E3S-R.
Note: Refer to Reflectors on E39-L/F39-L/E39-S/E39-R for details.
Mounting Brackets and Other Products (Refer to Dimensions on E39-L/F39-L/E39-S/E39-R.)
Appearance
Model
Quantity
Remarks
E39-L69
1
Provided with the E3S-R1@ and E3S-R3@.
E39-L70
1
Provided with the E3S-R6@ and E3S-R8@.
E39-L6
1
Provided with the E3S-RS30E4@ and E3S-R1E4@.
E39-L2
1
Can be used with the E3S-RS30E4@ and E3S-R1E4@.
E39-L97
1
Horizontal protective cover bracket
Can be used for compact models with plastic housing.
Refer to E39-L@.
E39-L98
1
Vertical protective cover bracket
Can be used for compact models with plastic housing.
Refer to E39-L@.
E39-L60
1
Close Mounting Plate
Provided with the E3S-R@6 and E3S-R@7.
Note: 1. When using through-beam models, order
one bracket for the Receiver and one for
the Emitter.
2. Refer to Mounting Brackets on E39-L/
F39-L/E39-S/E39-R for details.
2
E3S-R
Sensor I/O Connectors (M12) (Refer to Dimensions on XS2.)
Cable
Appearance
Cable type
Model
2m
Straight
XS2F-D421-DC0-F
5m
Standard
L-shape
XS2F-D421-GC0-F
3-wire
2m
XS2F-D422-DC0-F
5m
XS2F-D422-GC0-F
Note: For details on Sensor I/O Connectors and cables such as vibration-proof robot cables, refer to Introduction to Sensor I/O Connectors.
Ratings and Specifications
Sensing method
Item
Model
NPN
Retro-reflective
Retro-reflective
(with MSR function) *1
E3S-R12, R62, R17, R67
E3S-R11, R16, R61, R66
PNP
---
Retro-reflective
E3S-RS30E4, RS30E42
E3S-R31, R36, R81, R86
Sensing distance
300 mm [100 mm] *2
(When using E39-R1)
1 m [100 mm] *2
(When using E39-R1)
Standard sensing
object
Opaque: 75-mm dia. min.
0.7-mm-thick LCD glass
Opaque: 75-mm dia. min.
boards; 10-mm-dia., 1.0-mm- 0.7-mm-thick LCD glass
thick, 30-mm-long cylindrical boards
glass objects
Directional angle
3° to 10°
Light source
(wavelength)
Infrared LED (880 nm)
Power supply
voltage
10 to 30 VDC; ripple: 10% max.
E3S-R1E4, R1E42
--300 mm
(When using E39-R1)
--1m
(When using E39-R1)
Opaque: 75-mm dia. min.
10-mm-dia., 1.0-mm-thick, 30-mm-long cylindrical glass objects
---
Red LED (700 nm)
Current consumption 30 mA max.
Infrared LED (950 nm)
12 to 24 VDC±10%; ripple: 10% max.
40 mA max.
Control output
Load power supply voltage: 30 VDC max.
Load current: 100 mA max. with a maximum residual voltage
of 1 V
Open collector output configuration
Light-ON/Dark-ON selector switch
Load power supply voltage: 24 VDC max
Load current: 80 mA max. with a maximum residual voltage:
of 2 V
NPN voltage output configuration
Light-ON/Dark-ON cable connection selection
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention
Response time
Operate or reset: 1 ms max.
Sensitivity
adjustment
Two-turn endless adjuster
One-turn adjuster
Ambient illumination
(Receiver side)
Incandescent lamp: 5,000 lx max.
Sunlight: 10,000 lx max.
Incandescent lamp: 3,000 lx max.
Sunlight: 10,000 lx max.
Ambient
temperature range
Operating: 0 to 40°C, Storage: −40 to 70°C (with no icing or condensation)
Ambient
humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Operating: −25 to 55°C
Storage: −40 to 70°C
(with no icing or condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67
Connection method
Pre-wired (standard length: 2 m)/Standard connector
Weight
(packed state)
Pre-wired models: Approx. 110 g
Standard connector: Approx. 60 g
Materials
Pre-wired models: Approx. 190 g
Case
Polybutylene terephthalate
Zinc die-cast
Lens
Modified polyallylate
Polycarbonate
Mounting
Bracket
Stainless steel (SUS304)
Iron
Mounting Bracket (with screw), Adjustment screwdriver, Instruction manual, Reflector
Mounting Bracket (with screw), Adjustment screwdriver,
Sensitivity adjuster, Instruction manual, Reflector
Accessories
*1. Refer to MSR function of Technical Guide (Technical version).
*2. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.
3
E3S-R
Engineering Data (Typical)
Parallel Operating Range
Retro-reflective
E3S-R12, E3S-R62 + E39-R1
(Supplied Reflector)
E3S-R@1, E3S-R@6 + E39-R1
(Supplied Reflector)
E3S-RS30E4@ + E39-R1
(Supplied Reflector)
30 Reflector E39-R1
Y
20
X
10
0
100
200
300
400
500
600
60 Reflector: E39-R1
Set distance Y (mm)
Set distance Y (mm)
Retro-reflective
Set distance Y (mm)
Retro-reflective
Y
40
X
20
0
700
0.4
0.8
1.2
1.6
−40
−30
−60
300
400
500
Set distance X (mm)
−40
Excess Gain vs. Set Distance
E3S-R1E4@ + E39-R1
(Supplied Reflector)
E3S-R12, E3S-R62 + E39-R1
(Supplied Reflector)
E3S-R@1, E3S-R@6 + E39-R1
(Supplied Reflector)
6 Reflector: E39-R1
Excess gain ratio
Excess gain ratio
6 Reflector: E39-R1
5
4
5
4
5
1.2
1.6
2
Set distance X
(m)
3
3
2
2
Operating
level
−10
0.8
1
0
−15
100
200
300
400
1
500
0
0.4
0.8
1.2
E3S-RS30E4@ + E39-R1
(Supplied Reflector)
2.0
E3S-R1E4@ + E39-R1
(Supplied Reflector)
100 Reflector: E39-R1
100 Reflector: E39-R1
50
30
10
50
30
10
5
5
3
3
Operating
level
Excess gain ratio
1.6
Distance (m)
Distance (mm)
Excess gain ratio
−5
0.4
Operating
level
0
Operating
level
Set distance Y (mm)
200
−30
Retro-reflective
X
100
−20
−20
Y
10
−10
−20
10
X
20
0
Set distance X (mm)
15 Reflector: E39-R1
Y
30
2.0
Set distance X (m)
−10
40 Reflector: E39-R1
1
1
0.5
0.5
0.3
0.3
0.1
0.1
0
100
200
300
400
500
Distance X (mm)
0
0.5
1
1.5
2
2.5
Distance X (m)
4
E3S-R
Light Level Change Rates with Various Transparent Objects (*1)
The following are the permeation rates of various transparent objects on condition that a permeation rate of 100 means that there is no object within
the sensing distance of the E3S-R. The permeation rate of any type of object sensed by the E3S-R must be as low as possible for reliable detection
of the object. Before using the E3S-R, be sure to test it on samples to make sure it can detect the items reliably.
Sensing object
Appearance
Model
Through
position
10 dia. × 30, t = 1.0
Cylindri- 15 dia. × 30, t = 1.25
20 dia. × 30, t = 1.7
cal
glass
30 dia. × 30, t = 1.9
object
100 dia. × 30, t = 2.5
200 dia. × 30, t = 5.0
50 × 50, t = 0.5
50 × 50, t = 1
50 × 50, t = 2
Glass
plate
50 × 50, t = 3
50 × 50, t = 5
50 × 50, t = 10
t = 0.5
(permeability of 98%) *2
Liquid
t = 0.7
crystal
(permeability of 95%) *2
glass
t = 1.1
(permeability of 91%) *2
Operating range
Stable operating range
E3S-R12, R62
E3S-R17, R67
E3S-R11, R31, R61, R81
E3S-R16, R36, R66, R86
E3S-RS30@@
E3S-R1@@
Center
Center
Center
Center
27
27
22
41
58
55
82
74
73
62
53
38
------------82
74
73
62
53
38
20
20
28
43
55
58
78
70
70
58
50
35
33
13
13
23
50
58
--75
75
65
55
40
86
86
---
---
81
81
---
---
75
75
---
---
95 max.
90 max.
95 max.
90 max.
90 max.
70 max.
80 max.
60 max.
*1. The sensing distance of each model was set to the rated sensing distance.
*2. The permeability values were checked with light at a wavelength of 700 μm.
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing Charts
Operation
selector
Output circuit
Incident light
No incident light
Light
indicator
Light indicator ON
(Red)
OFF
Light-ON
Output
transistor
OFF
Operate
Load
(e.g., relay) Reset
E3S-R11(12)
E3S-R61(62)
E3S-R16(17)
E3S-R66(67)
L side
(LIGHT ON)
ON
(Between brown
and black leads)
(Red)
1
Stability
indicator
Brown
Load
(relay)
(Green)
Photoelectric
Sensor
main
circuit
100 mA max.
4
Black
10 to
30 VDC
ZD
3
Incident light
Blue
No incident light
Light indicator ON
(Red)
OFF
Dark-ON
Output
transistor
Connector Pin Arrangement
D side
(DARK ON)
ON
OFF
Operate
Load
(e.g., relay) Reset
1
2
4
3
(Between brown
and black leads)
Note: Pin 2 is not used.
5
E3S-R
PNP Output
Operation
mode
Model
Timing Charts
Operation selector
Output circuit
Incident light
No incident light
1
Light indicator ON
(Red)
OFF
Light-ON
OFF
Operate
Load
(e.g., relay) Reset
E3S-R31
E3S-R36
E3S-R81
E3S-R86
L side
(LIGHT ON)
ON
Output
transistor
Light
indicator
(Red)
Stability
indicator
(Green)
ZD
Photoelectric
Sensor
main
circuit
(Between blue
and black leads)
Brown
4
Load
(relay)
3
Incident light
10 to
30 VDC
Black
100 mA max.
Blue
No incident light
Connector Pin Arrangement
Light indicator ON
(Red)
OFF
Dark-ON
D side
(DARK ON)
ON
Output
transistor
OFF
Operate
Load
(e.g., relay) Reset
1
2
4
3
Note: Pin 2 is not used.
(Between blue
and black leads)
Plug (Sensor I/O Connector)
Terminal No.
1
2
3
4
2
1
3
4
Brown
Classification
Wire color
Connection
pin No.
Application
DC
Brown
--Blue
Black
1
2
3
4
Power supply (+V)
--Power supply (0 V)
Output
Blue
Black
XS2F-D421-DC0-F
Refer to Introduction
to Sensor I/O
connectors for
details.
Note: Pin 2 is not used.
Model
Operation
mode
Timing Charts
Cable
Connection
Output circuit
Incident light
No incident light
Light indicator ON
(Red)
OFF
Light-ON
Output
transistor
ON
OFF
Operate
Load 1
(e.g., relay) Reset
Brown cable:
+V
Blue cable:
0V
Light
indicator
(Red)
(Between brown and black leads)
H
Load 2
L
E3S-RS30E4(42)
E3S-R1E4(42)
(Between blue and black leads)
No incident light
Dark-ON
Output
transistor
ON
OFF
Operate
Load 1
(e.g., relay) Reset
Stability
indicator
(Green)
Photoelectric
Sensor
Main
Circuit
Incident light
Light indicator ON
(Red)
OFF
12 to
Brown *1 24 VDC
Brown cable:
0V
Blue cable:
+V
1.5 to
4 mA
Load 1
(relay)
80 mA max.
Black
*2
Load 2
Blue *1
1.5 to 4 mA
0V
(Between blue and black leads)
Load 2
H
L
(Between brown and black leads)
*1. Reverse the polarity of the power supply to change the output mode of the E3S-R.
*2. Voltage output (When connecting a transistor circuit, etc.)
6
E3S-R
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
● Adjusting
• When the E3S-R senses a cylindrical object, the amount of light
received varies with the direction of the cylindrical object. To
prevent this, locate the E3S-R as shown in the following illustration.
Reflector
• When the E3S-R senses an uneven plastic container or glass
bottle, the amount of light received varies with the direction and
sensing part of the plastic container or glass bottle. To prevent this,
turn a sample of the plastic container or glass bottle to the best
sensing position of the E3S-R to find and decide the optimum
direction and sensing part, and then make the sensitivity
adjustment.
• In principle, sensing objects must pass through the center between
the E3S-R and the reflector. Sensing objects must not be too close
to the Reflector, otherwise sensing errors may result.
• Unless otherwise indicated, the E39-R1 Reflector is required for
transparent object detection. The Receiver may not receive any
light and detection capability may decline with other Reflectors.
7
E3S-R
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
Compact Horizontal Models with Plastic Housing
Pre-wired Models
E3S-R11, E3S-R12
E3S-R31
With Mounting Bracket Attached
Light indicator (red)
*2
15.2
*1
42.3
7
2.3
Sensitivity adjuster (white)
(4)
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
Optical axis
12.4 12
Mounting Holes
16.9
Two, M3
10.7
16.5
3.2 7.2
Stability indicator
(green)
5
7.2
Two mounting holes
20
10.5
Lens (7 × 14)
20
Stainless steel (SUS304)
3.2
4.8
30
Operation selector (black)
Receiver
Light-ON
(ON when light
is received.)
Dark-ON (ON when
light is not received)
Optical
axis
D
1.3
L
21
9
11.5
29.2
19.7
1.2
Emitter
(A)*3
10.7
*4
*1. 40.0 for the E3S-R12
*2. 12.9 for the E3S-R12.
Two, M3 × 12
*3. The mounting bracket can be attached to this side.
*4. Not available on the E3S-R12.
Standard Connector Models
E3S-R16, E3S-R17
E3S-R36
With Mounting Bracket Attached
Light indicator (red)
*2
15.2
*1
42.3
Sensitivity adjuster
(10)
M12 Connector
7
2.3
12.4 12
Optical axis
Mounting Holes
16.9
Two, M3
10.7
16.5
3.2 7.2
3.2
4.8
Stability indicator (green)
5
10.5
Lens (7 × 14)
20
Stainless steel (SUS304)
7.2
Two mounting holes
20
30
Operation selector (black)
Receiver
Light-ON
(ON when light
is received)
Dark-ON (ON when
light is not received)
Optical
axis
D
1.3
L
21
1
9
11.5
29.2
4
2
3
19.7
1.2
Emitter
(A)*3
10.7
*4
Two, M3 × 12
*1. 40.0 for E3S-R17.
*2. 12.9 for E3S-R17.
*3. The mounting bracket can be attached to this side.
*4. Not available on the E3S-R17.
8
E3S-R
Compact Vertical Models with Plastic Housing
Pre-wired Models
E3S-R61, E3S-R62
E3S-R81
With Mounting Bracket Attached
Receiver
Lens (7 × 14)
Optical axis
Emitter
(4)
40
17
4.8
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
Optical axis
12.4 12
Mounting Holes
Use these two
holes for mounting.
16.9
10.7
Two, M3
16.5
7.2
20
Stainless steel (SUS304)
20
5.5 5.4
Stability indicator
(green)
Light indicator (red)
Sensitivity adjuster
Four mounting holes
3.1
3.6
41.7
7.2
Operation selector (black)
*5
5.9 *2
*1
23.3
Light-ON
(ON when light
is received)
Dark-ON (ON when
light is not received)
D
L
7
*3
31.5
1.2 10.7
(A)*4
1.3
*4. The mounting bracket can be attached to this side.
*5. Not available on the E3S-R62.
Standard Connector Models
E3S-R66, E3S-R67
E3S-R86
*1. 21.0 for the E3S-R62.
*2. 3.6 for the E3S-R62.
*3. 29.2 for the E3S-R62.
Two, M3 × 12
20±0.2
10.5
With Mounting Bracket Attached
Receiver
Lens (7 × 14)
Optical axis
Emitter
40
(10)
M12 Connector
17
Optical axis
14.9 12
Mounting Holes
Use these two
holes for mounting.
19.4
10.7
Two, M3
16.5
7.2
20
Stainless steel (SUS304)
20
Stability indicator (green)
3.1
3.6
41.7
Light indicator (red)
Sensitivity adjuster
Four mounting holes
7.2
Operation selector (black)
Light-ON
(ON when light is received)
*5
Dark-ON (ON when
light is not received)
5.9 *2
D
*1
23.3
L
7
31.5
1
*3
4
2
3
1.2 10.7
(A)*4
1.3
10.5
20±0.2
Two, M3 × 12
*1. 21.0 for the E3S-R67.
*2. 3.6 for the E3S-R67.
*3. 29.2 for the E3S-R67.
E39-L60 Close Mounting Plate (provided)
(Attach the mounting plate or the
*4. The mounting bracket can be attached to this side.
plug cannot be connected.)
*5. Not available on the E3S-R67.
9
E3S-R
Horizontal Models with Metal Housing
With Mounting Bracket Attached
E3S-RS30E4
E3S-R1E4
(A)*
Stability indicator (green)
Light indicator (red)
(66.6)
55
23
20
Optical 7.1 Lens (10 × 15)
axis
11
13
Sensitivity adjuster
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm),
Standard length: 2 m
7
Mounting Holes
Optical 20
axis
20.4
Two, M4
13 dia.
22.2
25.4
20
5
4.2
Emitter
Receiver
1.6
2.1R
Iron
4.2
12
22
24.9
Two, M4 slotted hexagon
head bolts
6.5
2.1R
5
25.4
39
* The mounting bracket can be attached to this side.
1.9
(32)
Vertical Models with Metal Housing
With Mounting Bracket Attachment
E3S-RS30E42
E3S-R1E42
Lens (10 × 15)
21.5
18.6
Emitter 7.1
Receiver
Optical axis
(A)*
Stability indicator (green)
Light indicator (red)
(74.6)
63
11
13
23
20
Sensitivity adjuster
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2,
Mounting Holes
Insulator diameter: 1.2 mm),
Standard length: 2 m
Two, M4
7
Optical 20
axis
20.4
10.2
13 dia.
25.4
22.2
20
1.6
5
4.2
2.1R
Iron
12
(32)
Two, M4 slotted hexagon
head bolts
6.5
2.1R
4.2 5
25.4
39
1.9
* The mounting bracket can be attached to this side.
Accessories (Order Separately)
Sensitivity Adjuster
Refer to E39-L/F39-L/E39-S/E39-R for details.
Reflectors
Refer to E39-L/F39-L/E39-S/E39-R for details.
Mounting Brackets
Refer to E39-L/F39-L/E39-S/E39-R for details.
Close Mounting Plates
Refer to E39-L/F39-L/E39-S/E39-R for details.
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
10
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2013.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2013 All Right Reserved.
Similar pages