Omron E3T-FD13N Subminiature photoelectric sensor Datasheet

R
Subminiature Photoelectric Sensor
E3T
Omron’s Next Generation of
Sub-miniature Photoelectric Sensors
H Utilizes Omron’s “Hyper LED” technology
H
H
H
H
H
H
H
H
to achieve the industry’s smallest visible
red beam
Self-contained sensor ideal for
space-restricted applications
“Pin-point” beam for detecting extremely
small objects
Offered in both flat and rectangular
body styles
Retroreflective model employs Omron’s
Free-Angle Optics technology (FAO) to
detect objects as small as 2 mm dia.
Convergent-beam model spot diameter
is 0.15 mm
Through-beam model is capable of
sensing distances of 1 meter with a 2 mm
target diameter
CE conformance
Robotic cable versions available
(See Note 2, below.)
Ordering Information
J PHOTOELECTRIC SENSORS
Sensing method
Sensor type
yp
Retroreflective
Diffuse reflective
Convergent-beam
Appearance
pp
Through-beam
Side-view
Flat
Side-view
Flat
Side-view
Sensing distance
1m
500 mm
10 to 200 mm
5 to 30 mm
5 to 15 mm
5 to 30 mm
NPN
E3T-ST11
E3T-FT11
E3T-SR11
E3T-FD11N
E3T-SL11
E3T-SL21
PNP
E3T-ST13
E3T-FT13
E3T-SR13
E3T-FD13N
E3T-SL13
E3T-SL23
NPN
E3T-ST12
E3T-FT12
E3T-SR12
E3T-FD12N
E3T-SL12
E3T-SL22
PNP
E3T-ST14
E3T-FT14
E3T-SR14
E3T-FD14N
E3T-SL14
E3T-SL24
Part number
Light-ON
g
Dark-ON
Note: 1. All through-beam models are packaged and sold as pairs (one transmitter and one receiver).
2. E3T sensors are available with robotic cable. To order, add the letter “R” to the end of the part number. Example: E3T-ST11R
3. 5-M cable models are available. To order, add the desigination 5M to the end of the part number. Example: E3T-T11 5M
E3T
E3T
J ACCESSORIES (ORDER SEPARATELY)
Slits (Apertures)
Slits for sensor models
Slit width
Sensing distance
Minimum sensing object (typical)
Comments
Part number
E3T-ST1j
3 S j
0.5 dia.
50 mm
0.5 mm wide
E39-S63
1 dia.
100 mm
1 mm wide
One each for Emitter
and
d Receiver
R
i
Slits for sensor models
Slit width
Sensing distance
Minimum sensing object (typical)
Comments
Part number
j
E3T-FT1j
3
0.5 dia.
50 mm
0.5 mm wide
E39-S64
1 dia.
100 mm
1 mm wide
One each for Emitter
and
d Receiver
R
i
Item
Sensing distance
Minimum sensing object (typical)
Part number
Compact retroreflective model
10 to 200 mm
2 mm wide
E39-R4
(See Note.)
Reflectors
10 to 100 mm
Note:
E39-R37
E39-R4 reflector included with the E3T-SR1j (can also be ordered separately).
Adjustable Aperture
For sensor models
Appearance
Part number
E39-E10
E3T-ST1j
Mounting Brackets
For sensor models
E3T-Sj
Appearance
Comments
Part number
Two mounting brackets are required for through-beam
models.
E39-L116
E39-L117
E39-L118
E3T-Fj
E39-L119
E39-L120
2
E3T
E3T
Specifications
J RATINGS/CHARACTERISTICS
Sensing method
Through-beam
Shape
Side-view
Flat
Output type
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
Light-ON
-ST11
-ST13
-FT11
-FT13
-SR11
-SR13
-SL11
-SL13
-SL21
-SL23
-FD11
-FD13
Dark-ON
-ST12 -ST14
-FT12
-FT14
-SR12
-SR14
-SL12
-SL14
-SL22
-SL24
-FD12
-FD14
Sensing distance
1m
(adjustable
aperture is
available)
500 mm
Standard sensing target
Min. sensing target
(typical)
Hysteresis
---
Part number
Optical
p
angle
l
Retroreflective
Convergent beam
Flat
10 to 200 mm
(with the E39-R4)
5 to 15 mm
(50 x 50 mm
Kodak white
card)
2 mm dia. min.
10 mm dia. min.
---
2 mm dia. min.
2 mm dia.
(sensing distance
at 100 mm)
0.15 mm dia. (sensing distance at 10 mm)
2 mm max.
Emitter
3° to 10°
3° to 13°
2° to 5°
Receiver
3° to 70°
3° to 70°
---
5 to 30 mm
(50 x 50 mm
Kodak white
card)
6 mm max.
5 to 30 mm
(50 x 50 mm
Kodak white card)
6 mm max.
---
Light source
(wave length)
Red LED (“Pin-point” LED) (λ=670 nm)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Current consumption
12 mA max.
max emitter/receiver
Output
Open collector, load current: 50 mA max. at 24 VDC, residual voltage: 1 V max.,
operation mode: Light-ON or Dark-ON (separate models)
Circuit protection
(See Precautions
Section.)
Protection from reversed and
output short-circuit
Response time
1 ms max. each for on and off
24 VDC
±10%
20 mA max.
max
Protection from reversed polarity, output short-circuit, and mutual
interference
Ambient
g
light
i
immunity
it
Incandes- 5,000 ℓx max.
cent lamp
Sunlight
10,000 ℓx max.
Ambient
temperature
Operating
--25°C to 55°C (--13°F to 131°F)
Storage
--40°C to 70°C (--40°F to 158°F) with no icing or condensation
Ambient
h idi
humidity
Operating 35% to 85% RH
Storage
Diffuse reflective
Side-view
35% to 95% RH (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude or 300 m/s2 (approx. 30G) for 0.5 hrs each in X, Y, and Z axis
Shock resistance
1,000 m/s2 (approx. 100G) 3 times each in X, Y, and Z axis
Enclosure rating
IEC60529: IP67
Connection method
Pre-leaded (standard length: 2 m), optional 5-M cable, optional robotic cable
Weight (with packaging)
Approx. 40 g
Materials
Case
PBT
Lens and
cover
Polycarbonate
Accessories included
Approx. 20 g
Two each of M2 mounting screws, spring washers, and flat washers, and reflector (E39-R4: retroreflective
model only)
3
E3T
E3T
Engineering Data
J EXCESS GAIN VS. SET DISTANCE (TYPICAL)
Excess gain ratio
E3T-FD1j (Diffuse Reflective)
Operation
level
White paper
Black paper
Set distance (mm)
4
Excess gain ratio
Excess gain ratio
Set distance (mm)
Operation
level
0
400
800
1200
1600
2000
Set distance (mm)
E3T-SL1j (Convergent Beam)
Operation
level
White paper
Operation
level
Set distance (mm)
E3T-SL2j (Convergent Beam)
Excess gain ratio
Operation
level
E3T-SR1j with E39-R4 (Retroreflective)
E3T-FT1j (Through-beam)
Excess gain ratio
Excess gain ratio
E3T-ST1j (Through-beam)
White paper
Operation
level
Black paper
Set distance (mm)
Black paper
Set distance (mm)
E3T
E3T
J PARALLEL OPERATING RANGE (TYPICAL)
E3T-ST1j with Slit (Aperture)
(Through-Beam)
E3T-ST1j with Slit (Enlarged graph)
(Through-Beam)
E3T-SR1j with E39-R4
(Retroreflective)
400
800
1,200
1,600
2,000
Distance X (mm)
0.5-dia. Slit
200
1-dia. Slit
400
1-dia. Slit
Distance X (mm)
Without Slit
600
800
Distance X (mm)
E3T-FT1j with Slit (Enlarged graph)
(Through-Beam)
Distance Y (mm)
Distance Y (mm)
E3T-FT1j with Slit (Through-Beam)
0.5-dia. Slit
Distance Y (mm)
1-dia. Slit
0.5-dia.
Slit
Distance Y (mm)
Distance Y (mm)
Without Slit
0.5-dia. Slit
1-dia. Slit
Distance X (mm)
1,000
Distance X (mm)
J ANGLE CHARACTERISTICS (TYPICAL)
(Left and Right)
Sensing target:
100 x 100 mm white paper
Angle θ (°)
Sensing distance change rate (%)
E3T-SL1j
(Up and Down)
Sensing distance change rate (%)
E3T-SL1j
Sensing target:
100 x 100 mm white paper
Angle θ (°)
5
E3T
E3T
J CLOSE-DISTANCE SENSING CAPABILITY (TYPICAL)
E3T-SL1j, E3T-SL2j, E3T-FD1j
Sensing distance (mm)
j White paper
J Black paper
E3T-SL1j
E3T-SL2j
E3T-FD1j
J SENSING TARGET SIZE VS. SENSING DISTANCE (TYPICAL)
E3T-SL1j
E3T-FD1j, E3T-SL2j
Min. sensing target dia. (mm)
Min. sensing target dia. (mm)
Sensing target:
Pin-gauge, stainless steel
Sensing distance (mm)
E3T-FD1j
E3T-SL2j
Sensing distance (mm)
J OPERATION RANGE (TYPICAL)
E3T-FD1j (Diffuse Reflective)
E3T-SL1j (Convergent Beam)
6
Sensing target:
50 x 50 mm white paper
Sensing
distance
X (mm)
Sensing distance X (mm)
Operating position Y (mm)
Sensing target:
50 x 50 mm white paper
Operating position Y (mm)
Operating position Y (mm)
Sensing target:
50 x 50 mm white paper
E3T-SL2j (Convergent Beam)
Sensing
distance
X (mm)
E3T
E3T
J SENSING DISTANCE CHARACTERISTICS OF ADJUSTABLE APERTURE
(WHEN COMPLETING OPTICAL AXIS ADJUSTMENT)
Sensing distance (m)
E3T-SL1j with E39-E10
Sensitivity adjustment level
Operation
J OUTPUT CIRCUITS
NPN models
E3T-jjj1
E3T-jjj2
Operation mode
Light-ON
Dark-ON
Output circuit
Operation
indicator
(Orange)
Brown
Stability
indicator
(Green)
12 to 24 VDC
50 mA
max.
Black
Photoelectric
Sensor
main
circuit
Load
0V
Blue
PNP models
E3T-jjj3
E3T-jjj4
Operation mode
Light-ON
Dark-ON
Output circuit
Receiver (through-beam models),
Retroreflective, diffuse reflective, and convergent beam models
Operation
indicator
(Orange)
Brown
Stability
indicator
(Green)
Black
Photoelectric
Sensor
main
circuit
Internal circuit
50 mA
max.
12 to 24 VDC
Load
Blue
Emitter (through-beam models)
Brown
Photoelectric
Sensor
main
circuit
12 to 24 VDC
Blue
7
E3T
E3T
J TIMING CHART
Diffuse and convergent
g
beam
Light-ON
Dark-ON
Target present
Target present
Target not present
OFF
Output
transistor
OFF
ON
Operation
indicator
(orange)
ON
Load
De-energized
ON
OFF
ON
Output
transistor
Energized
Load
Retroreflective/through-beam
/
g
Target not present
Operation
indicator
(orange)
OFF
Energized
De-energized
Light-ON
Dark-ON
Target present
Target present
Target not present
Target not present
Operation
indicator
(orange)
OFF
Output
transistor
OFF
Load
ON
Operation
indicator
(orange)
ON
Output
transistor
Energized
Load
De-energized
ON
OFF
ON
OFF
Energized
De-energized
Dimensions
Unit: mm (inch)
J SIDE-VIEW SENSORS
Through-Beam Models
E3T-ST11
E3T-ST12
E3T-ST13
E3T-ST14
Mounting Holes
Emitter
7 (0.28)
Lens: 1.7 dia.
Receiver
Operation
indicator
Lens: 2 dia.
Emitter
Receiver
9.5
(0.37)
Two, M2
7 (0.28)
Stability
indicator
(0.59)
Two, 2.2 dia.
14.6
(0.57)
18.5
(0.73)
Polyvinyl chloride-covered cable,
2.4-mm dia. (7/0.127 dia.),
Robotic cable (20/0, 0.08-mm dia.),
2 conductors, emitter
3 conductors, receivers
Standard length: 2 m
8
E3T
E3T
Retroreflective Models
E3T-SR11
E3T-SR12
E3T-SR13
E3T-SR14
11
(0.43)
7 (0.28)
Operation
indicator
Stability
indicator
Mounting Holes
Two, M2
Two, 2.2 dia.
Len: 2 dia.
20.6
(0.81)
Emitter and
Receiver
(0.59)
24.5
(0.96)
Polyvinyl chloride-covered cable,
2.4-mm dia. (7/0.127 dia.),
Robotic cable (20/0, 0.08-mm dia.),
3 conductor Standard length: 3 m
Convergent-Beam Models
E3T-SL11
E3T-SL12
E3T-SL13
E3T-SL14
E3T-SL21
E3T-SL22
E3T-SL23
E3T-SL24
11
(0.43)
7 (0.28)
Operation
indicator
Lens 3.7 × 2
Emitter
Stability
indicator
Mounting Holes
Two, 2.2 dia.
Two, M2
20.6
(0.81)
24.5
(0.96)
(0.59)
Receiver
Lens 4.4 × 2
Polyvinyl chloride-covered cable
2.4-mm dia. (7/0.127 dia.),
Robotic cable (20/0, 0.08-mm dia.),
3 conductor
Standard length: 3 m
9
E3T
E3T
Unit: mm (inch)
J FLAT THIN SENSORS
Through-Beam Emitter and Receiver Models
E3T-FT11
E3T-FT12
E3T-FT13
E3T-FT14
Mounting Holes
Two, M2
Operation indicator
(See Note below)
12
(0.47)
Stability indicator
3.5
(See Note.)
(0.13)
Two, R2
0.2
(0.008)
(0.31)
Optical axis
15.8
(0.62)
Lens 1.3 dia.
19
(0.75)
Two, 2.2 dia.
Polyvinyl chloride-covered cable
2.4-mm dia. (7/0.127 dia.),
Robotic cable (20/0, 0.08-mm dia.)
3 conductor
Standard length: 2 m
Note: For E3T-FT11 and E3T-FT12 Receivers only.
Diffuse Reflective Models
E3T-FD11-N
E3T-FD12-N
E3T-FD13-N
E3T-FD14-N
Mounting Holes
Operation
indicator
12
(0.47)
Two, M2
Stability
indicator
Two, R2
0.2
3.5
(0.14)
(0.31)
Lens 1.5 dia.
Emitter
20.8
(0.82)
Optical axis
24
(0.94)
Receiver
Lens 3.1 dia.
Two, 2.2 dia.
1.75
Polyvinyl chloride-covered cable,
2.4-mm dia. (7/0.127 dia.),
Robotic cable (20/0, 0.08-mm dia.)
3 conductor
Standard length: 2 m
J REFLECTORS
Retroreflector
13.7
(0.54)
4.9
(0.19)
E39-R4 (Provided with the E3T-SR1j)
23
(0.91)
Two, 2.2 dia.
10
E3T
E3T
E39-R37 Reflector
13.7
(0.54)
23
(0.91)
Reflector
0.6 (with adhesive)
Two 3.1 dia
Stainless steel
mounting plate 0.5
301 Stainless steel
Note: A reflector and a stainless steel mounting
plate are supplied together as a set.
J SLITS/APERTURES (ORDER SEPARATELY)
Shown with Sensor
E39-S63 (Use with E3T-ST1j)
7.4
(0.29)
Two, 2.2 dia.
1.0±0.05 dia.
0.5±0.05 dia.
7.4
(0.29)
E39-S64 (Use with E3T-FT1j)
9.7
(0.38)
4.1
(0.16)
12.3
(0.48)
12.6
(0.50)
Notch
Material:
0.2-mm-thick stainless steel
(301 Stainless)
1 dia.
0.5 dia.
Note: Align the notch direction of
the slit when installing on
the Emitter and Receiver.
Use of E39-E10 Adjustable Aperture
Adjustable Aperture
(Example Dark-ON: E3T-ST12/ST14)
E39-E10 (Use with E3T-ST1j)
(At Min.)
With the Adjustable Aperture
Unit in Place
(At Center)
(At Max.)
Indicator
Adjuster
7.4
(0.29)
15.1
(0.59)
Optical axis
2 dia.
18.7
(0.74)
For Dark-ON:
1. Mount the unit on the receiver.
2. Set the adjuster of the Unit to Max (factory setting is
at Max).
3. Adjust the optical axis (align) and tighten mounting
hardware.
4. Place a target between emitter and receiver and
gradually turn the adjuster counterclockwise toward
the Min side. Stop turning the adjuster when the operation indicator and stability indicator (green) turn
ON.
5. Remove the target and confirm that the operation
indicator is OFF and the stability indicator (green) is
ON.
Note: For Light-ON, adjustment is similar, except that
indicators would operate in opposite manner as
with Dark-ON.
11
E3T
E3T
Unit: mm (inch)
J MOUNTING BRACKETS
E39-L116 (Use with E3T-Sjjj) Order Separately
Two, R1.7
17.8
(0.70)
Two, R2
Two, R2
10.3
(0.41)
Material: 1.2-mm-thick
stainless steel (SS 304)
31.2
(1.23)
Two, R1.1
9.7
(0.38)
17.8
(0.70)
Two, R1.2
R1.5 max.
10
(0.39)
E39-L116 (Use with E3T-ST1j)
Four, R2
Three, M2
20.5
(0.81)
31
(1.22)
7
(0.28)
12
Two, M2 × 12
31.2
(1.23)
24.5
(0.96)
E3T
E3T
Order brackets separately.
E39-L117 (Use with E3T-Sjjj)
R1 max.
Two, R1.7
Two, R2
Two, R2
11.2
(0.44)
Material: 1.2-mm-thick
stainless steel (SS 304)
18
(0.71)
23
(0.91)
Two, R1.7
3.4
(0.13)
4.5
(0.18)
Two, R1.1
11.2
(0.44)
E39-L117 (Shown with E3T-ST1j)
10.3
(0.41)
11.2
(0.44)
Two, M2 × 12
Four, R2
20.5
(0.80)
Three, M2
10.2
(0.40)
11.2
(0.44)
23
(0.91)
13
E3T
E3T
Unit: mm (inch)
Order brackets separately.
E39-L118 (Use with E3T-Sjjj)
11.5
(0.45)
11.5
(0.45)
22.7 (0.89)
Two, R1.7
Material: 1.2-mm-thick
stainless steel (SS 304)
15
(0.59)
5
(0.20)
Two, R1.1
23
(0.91)
Four, R2
7.7
(0.30)
E39-L118 (Shown with E3T-ST1j)
Four, R2
Three, M2
Two, M2 × 12
20.5
(0.81)
15
(0.59)
14
16.3
(0.64)
13.2
(0.52)
23
(0.91)
E3T
E3T
Mounting Brackets for E3T-FT1j/E3T-FD1j
E39-L119
E39-L119 Shown with E3T-Fj1j
10.5
(0.41)
8
(0.31)
16
(0.63)
Four, M2 tapping holes
9
(0.35)
8
(0.31)
12
(0.47)
9
(0.35)
7
(0.28)
E39-L120
10.6
(0.42)
Two, M2 × 4
E39-L120
(Shown with E3T-Fj1j)
22.5 (0.89)
Four, M2 tapping holes
8
(0.31)
3.2
2.4
(0.09)
13.5
(0.53)
16
(0.63) 12
(0.47)
2.4
(0.09)
Two, M2 × 4
15
E3T
E3T
Precautions
J LOAD SHORT-CIRCUIT PROTECTION
Caution
J AVOID DAMAGE TO THE E3T
•
•
•
Do not exceed the rated voltage on the E3T.
Do not short-circuit the load connected to the E3T.
When supplying power to the E3T, make sure that the
polarity of the power is correct.
J OPERATING ENVIRONMENT
To avoid malfunction, DO NOT install the E3T in the following
environments:
•
•
•
•
Locations where the E3T is exposed to intense sunlight.
Locations with high humidity and where condensation may
result.
Locations with corrosive gas.
Locations with vibration or shock affecting the E3T.
J HIGH-TENSION LINES
To avoid Sensor damage or malfunctioning due to induction
noise, do not place the power supply lines of the Photoelectric
Sensor within the same conduit as power lines or high-tension
lines.
The E3T incorporates a load short-circuit protection function. If
the load short-circuits, the output of the E3T will be turned OFF.
Recheck the wiring and turn on the E3T again to reset the load
short-circuit protection function. The load short-circuit protection
function will work if there is a current flow that is 2.4 times larger
than the rated load current.
When using an inductance load, be sure that the inrush current
will not exceed 2.4 times larger than the rated current.
J CLEANING
DO NOT apply paint thinner when cleaning the E3T. Paint thinner
will damage the casing of the E3T.
J INDICATORS
The following graphs indicate the status of each operation level.
Be sure to use the E3T within the stable operating range.
Stable
operation
range
Unstable
operation
range
Stable
operation
range
J CABLE
The cable can be extended up to 100 m provided that cable
thickness does not exceed the 0.3 mm2 maximum.
Light
!
Avoid damage to the E3T: NEVER apply AC power to the E3T.
Note:
J POWER SUPPLIES
Stability
indicator
(green)
ON
Operation
level x 1.2
Operation
level
Operation indicator (orange)
E3T-jjj1
E3T-jjj2
E3T-jjj3
E3T-jjj4
ON
OFF
OFF
ON
OFF
Operation
level x 0.8
ON
When the E3T’s operation level is set to the stable
operation range, the E3T will be in its most reliable
operation without being influenced by temperature,
voltage fluctuation, dust, or mounting changes.
If a switching regulator is connected to the E3T, you must ground
the FG (frame ground) and G (ground) terminals, or the switching
noise of the switching regulator may cause the E3T to
malfunction.
J TURNING ON POWER SUPPLY
J WATER RESISTANCE
•
•
•
Do not use the E3T underwater, outdoors, or in the rain.
Use M2 screws and washers to mount the E3T. When
mounting the E3T, NEVER strike the E3T with a hammer, or
the E3T will lose its watertight properties.
•
The E3T will be ready for sensing 100 ms after the power is
turned ON.
If the E3T is connected to a power source different from one
for loads, be sure to turn ON the power supply to the E3T
first.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC
OMRON ON--LINE
OMRON CANADA, INC.
1-800-55-OMRON
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
416-286-6465
One East Commerce Drive
Schaumburg, IL 60173
Cat. No. E262-E3-3
1/02
Specifications subject to change without notice.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
Printed in U.S.A.
Similar pages