Omron E3X-DA11AT-S Evolution and perfection the next-generation platform for a wide range of sensing Datasheet

CSM_E3X-DA-S_MDA_DS_E_3_1
E3X-DA-S
Digital Fiber Sensors
Perfection Transcended!
A Wealth of Advanced Functions
for Easy and Reliable Application
Evolution and Perfection
The next-generation platform for a wide range of sensing
The industry's first Power Tuning Function in a digital sensor.
Large, Easy-to-Read Displays that are clear even from a distance.
Seven convenient display formats.
Stable long-term performance achieved with
OMRON's Auto Power Control (APC) function.
A wide array of Advanced Functions for even more applications.
The same Ease-of-Use as the E3X-DA-N Amplifier.
Environmentally
Friendly design.
Improved Mobile Console.
2
3
Industry's First Power Tuning Function in a Digital Sensor.
No complicated mode settings.
Large, bright
operation indicator
(like earlier models)
Patent Pending
Troublesome power adjustments have been eliminated, so it isn't necessary
to select from power mode settings, such as long-distance mode, standard
mode, and short-distance mode. When the MODE Key is pressed once, the
power tuning function shifts the power level so that the present incident level
is set to the ideal level (2000 on the digital display.)
Earlier Method
Large, Easy-to-Read Displays: Clear Even from a Distance
The displays are large and easy-to-read,
despite the small case.
Incident
insufficient
Short-distance mode
Appropriate
Standard mode
Appropriate
Long-distance mode
Saturated
Super-long-distance mode
Saturated
Threshold level
RUN mode
New Method
Incident level Threshold level
High-speed mode
Incident level
Press
Up to 5-fold increase
No power modes
Industry's largest
characters: 6 mm
(like earlier models)
Settings can be made more simply and confidently with two digital displays. For example, the
threshold value can be changed while reading the
incident level or a setting can be changed while
confirming the setting's function item number.
Function
Power tuning indicator added
to indicate setting status.
Setting
Up to 1/25 reduction
SET mode
The Sensor can be used immediately without
setting the mode.
If the incident light level is too high or too low,
just press the Mode key to achieve the optimum
status.
The best mode for each application was
selected from several power modes.
Function numbers
added to function
items.
Settings are now reversible.
Insufficient light or saturation at short distances can be corrected.
The power tuning range is extended to the allowable limits to eliminate problems such as insufficient light or detection failures due to saturation.
If the installation distance is too short, the incident light may saturate (i.e., to
a digital incident level of 4,000), preventing detection. The power can be
tuned down to 1/25th of the default setting for stable detection even at close
range.
Seven Convenient Display Formats
Patent Pending
Press
An incident level/threshold display, percentage/threshold display, and large bar graph display
have been added, so you can select the best display method for the application.
Without workpiece
Transparent workpiece
With workpiece
Incident level
does not change.
Incident level changes.
Incident Level/Threshold Display
Large Bar Graph Display
Percentage/Threshold Display
Incident light
Detection is not possible
Detection is possible.
Incident level
Threshold level
Change the threshold level while reading the incident level.
Variations between different Sensors can be eliminated.
Threshold levels had to be set and maintained separately for individual Sensors due to variations in the digital light levels measured by each Sensor.
With power tuning, the incident level can be fine-tuned so the same threshold level can be set for each Sensor in an application. Maintenance is also
simplified because it is easier to recognize measurement levels that have
shifted during operation.
Earlier Method
Incident level
Threshold level
Verify the difference between the incident level and threshold level while setting the threshold level.
Incident Level/Peak Hold Display
No incident light
Bar display
Check the incident level intuitively. Ideal
when it is better to view an analog display instead of the actual digital level.
Peak Hold/Bottom Hold Display
2055
2010
Press
New Method
Incident level
Peak hold
Threshold
level
1350
Detecting missing tablets
4
Digital light levels vary due to individual
differences in the Sensors, so the
threshold levels must be set individually.
All of the Amplifiers are set to the same digital light level, so the same threshold level
can be set and maintained for the Sensors.
Simultaneously display the peak hold level and
present incident level. The optical axis can be
adjusted more easily and surely by checking the
peak hold level while adjusting the optical axis.
1280
Display the peak level when light was brightest and bottom level when light was
dimmest. The digital levels of high-speed objects can be read precisely.
(Refreshing the hold level was changed from a fixed time to synchronizing with
the output, so the peak and bottom hold values can be checked with certainty.)
5
Stable, Long-term Performance with OMRON's APC Function
Many Advanced Functions for Even More Applications
Fastest in the Industry
OMRON provides the industry's most stable long-term detection
by using new 4-element LEDs and an APC (Auto Power Control) circuit.
Detecting Leads on Electronic Parts
Highest Level of Stability
In addition to our unique APC circuit used in the
E3X-DA-N Amplifiers to compensate for the deterioration of the LED, the E3X-DA-S uses 4-element LEDs to counteract the deterioration of the
light-emitting elements over time and achieve the
industry's most stable long-term detection performance.
Furthermore, the circuit is designed with excess
light capacity, so the Sensors can be used with
high stability regardless of whether the APC circuit is ON or OFF.
Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times.
New Method
Earlier Method
Incident level
4-element LED and APC
Incident level
3-element LED and APC
Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s.
A one-shot timer is supported in addition to the ON-delay and OFF-delay timers.
The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection.
Long-term stability
Discriminating Tablet Lengths
Without APC circuit
Without APC circuit
Time
Time
Compensate for the effects of contaminants and temperature variation
with differential operation mode. (Advanced Models)
Area output function can be
used for range judgement.
(Advanced Twin-output Models)
Operations that required multiple Sensors, such as
height measurement, can be performed with just one
Sensor. Two threshold levels can be set to easily output
within-range and out-of-range outputs.
Area output
Incident
level
2000
Threshold 1
1000
Threshold 2
Time
Output
ON
OFF
This operation mode uses a special OMRON algorithm to compensate for slight light level changes
due to dirt or temperature variations and detect only the light level changes due to the workpiece.
Detecting Seals
Remote input function can control the Sensor remotely.
(Advanced External-input Models)
Slight light level changes can be detected with stability and
precision, eliminating the need for time-consuming manual adjustments for light level changes.
With the Twin-output Amplifiers, output 2 can function as an
alarm output (light level operation) to indicate when the light
level has changed due to dirt or other causes.
Patent Pending
Judges light level changes by comparing
the incident level and threshold level.
Judges light level changes by comparing the
incident level to a time-averaged incident level.
Threshold level
(absolute value)
Incorrect operation due to light level change
Incident level
Differential Operation
Incident level
Light Level Operation
(Normal Operation)
Alarm output
Detecting marks in a dusty environment
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter
OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation
or making settings remotely because teaching has to be performed often for frequent workpiece model
changes.
The counter function can output signal after counter Patent Pending
counts up or down.
Counter Function
(Advanced External-input Models)
Down Counter
Up Counter
Detecting knots in thread
A counter function is built-in, so the number
of workpieces can be counted without a separate counter or small PLC that used to be
required.
Incident
level
Incident
level
Threshold
level
Time
Counter
Alarm output
threshold
The light level varies due to dirt, temperature
variations, or other environmental factors.
Incorrect operation
6
Time
Counter
Counter
value
Light level difference
(absolute value)
Time
Time
Detecting Chip Components
Time
Time
Detecting differences in the light level enables
setting more subtle light level differences.
Minute changes are
detected reliably.
Output when count reaches SV.
Output when count reaches 0.
7
The Same Ease-of-Use as the E3X-DA-N
Up to 16 Amplifiers can be connected.
<Using 5 Amplifiers>
Connector models
Relay connectors
not required.
Patent Pending
Japan patent number 3266198
In Amplifiers with Connectors, the power supply is distributed to slave connectors through a single master
connector. This design has three major advantages.
Prewired models
Power is supplied
from the master
Amplifier Unit to
the slave Amplifier
Units through the
Master Connector.
Separate power
lines and output
lines are required
for each Amplifier.
7 cables
Streamlined
wiring
Eliminate the installation time, cost, and
space associated with relay connectors.
Optical
communications
Power supply pin
1
Materials containing lead have been completely eliminated.
The Fiber Sensor is the first in the industry
to use environmentally friendly lead-free
solder.
Master connector
First in the industry
No lead!
15 cables
Power line
1. Wiring time is significantly reduced.
2. Relay connectors are unnecessary, so wiring takes up less space.
3. Storage and maintenance are simpler because it isn't necessary to distinguish between master connector and slave connectors on the Amplifier.
Environmentally friendly features are
essential in truly high-performance products.
Reduced Power Wiring Saves Space
Power line Output lines only
Simplified Connector Design
Output lines only
The E3X-DA-S uses OMRON's own
simplified wiring connectors that
were introduced with the E3X-DA-N.
Environmentally Friendly Design
Relay connectors
Slave connector
Optical communications
prevents mutual interference.
Pb
This ECO label is indicated on produts
that meet the environmental standards
established by OMRON.
Mutual interference is prevented with optical communications, so up to 10 Amplifiers can be mounted together.
(The number of Amplifiers depends on the operating conditions.)
Optical
communications
Close-mounting of up to 10 Sensors
Zero reset function immediately
resets the digital display to 0.
With Workpiece
2
Up to 10 Amplifiers
The digital display can be turned OFF or dimmed during operation. Eco-mode
When the digital display is viewed infrequently during operation, current consumption can be reduced by dimming the
display or turning it OFF entirely.
The display will light up again automatically when an operation key is touched. (Ecomode can be set from the Mobile Console
only.)
Without Workpiece
Patent Pending
Japan patent number 3255229
The zero reset function can immediately reset the
digital display to 0 at any time. By setting the reference value to 0, the threshold value can be set
while monitoring differences in incident light levels. The threshold value will also shift simultaneously when the zero reset button is pressed.
Shift
Incident level
difference = 700
Threshold level
set to 350.
Display not lit.
Lights up if an
operation is
performed.
Dimmed display
During operation
(After 30 s without
an operation)
Lights up if an
operation is
performed.
During operation
(After 30 s without
an operation)
Zero reset
Display reset to 0.
3
Cable disposal is not required during maintenance.
In addition to saving space and reducing
wiring time, the new connector design
eliminates the need to dispose of cables
together with the Amplifiers.
Reversible Digital Display (Reverse Mode)
The digital display can be reversed to match the
Amplifier's mounting direction.
Standard mode
Selectable
Cable disposal is not necessary.
Reverse mode
8
9
Further Improvements to the Mobile Console
Retains all of the Previous Advantages of the Mobile Console.
New and Improved
Fiber Sensor and
Mobile Console.
Can also be used with Photoelectric Sensors with Separate Digital Amplifiers.
Settings, teaching, and fine-tuning
can be performed at the fiber tip.
The Mobile Console can be used for settings and teaching at
the tip of the fiber. Difficult adjustments can be made while
checking the workpiece position.
Even if the Amplifier and Sensor head are separated during
operation, it is still possible to flash the Sensor head and display the amplifier channels.
E3X-DA-S
Digital Fiber Sensor
Channel 5
Channel 4
Channel 3
Channel 2
Channel 1
E3C-LDA
Photoelectric Sensor with Separate Digital Amplifier
E3X-MC-S
Mobile Console
Easily set
multiple Sensors.
Group Power Tuning
With the group power tuning function, power tuning is possible
for multiple Sensors at the same time.
With Group Teaching, Teach Multiple
Amplifiers Simultaneously.
Group teaching
The tedious teaching that had to be performed separately for
each Amplifier can now be performed for several Amplifiers at
once using the Mobile Console.
Copying Settings within the Same Group
Copy channel 1's
contents to all channels.
Channel 1
Channel 1
All channels
Channel 2
Channel 5
Settings such as mode or threshold settings in an Amplifier or
bank can be copied to all of the Amplifiers in the same group.
Group Power Tuning
The Age of Usercustomizable Sensors.
Improved Mode Lock Function
Settings can be customized for different applications by locking
out unnecessary function blocks within function settings.
Copying Settings to Other Groups
Function Block
Application
Set for manual operation.
Manual
All of the group's
settings are copied.
Machine A
Machine B
Manual setting
Teaching
Function setting
Operation OK
Locked
Locked
The settings for a group of Amplifiers on one machine can be
copied to a group of Amplifiers on another machine.
(The settings can also be copied to and from banks.)
Machine D
Set for teaching operation.
Teaching
Teaching
10
+
Manual
Set for teaching
+
manual operation.
Locked
Operation OK
Locked
Operation OK
Operation OK
Locked
11
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
In the interest of product improvement, specifications are
subject to change without notice.
Authorized Distributor:
This document provides information mainly for selecting
suitable models. Please read the Instruction Sheet
carefully for information that the user must understand
and accept before purchase, including information on
warranty, limitations of liability, and precautions.
CSM_E3X-DA-S_MDA_DS_E_3_1
CSM_E3X-DA-S_MDA_DS_E_3_1
E3X-MDA
Super Dual Fiber Sensor
Bringing a new dimension to sensing…
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including
information on warranty, limitations of liability, and precautions.
OMRON Corporation
Regional Headquarters
Industrial Automation Company
OMRON EUROPE B.V.
Sensor Business Unit, Carl-Benz-Str. 4,
D-71154 Nufringen, Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022
Fax: (81)75-344-7107
Authorized Distributor:
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, #11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Road (M),
Shanghai, 200120 China
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
CSM_E3X-DA-S_MDA_DS_E_3_1
In the interest of product improvement, specifications are subject to change without notice.
…the 2-channel amplifier has arrived.
Having problems gang-mounting Fiber Sensor Amplifier Units
in tight spaces?
Slimmest in the industry — 5 mm per channel.
Two Amplifiers squeezed into a body of width
10 mm.
Remarkable space saving of approx. 50%.
Power saving of approx. 40%.
Patent pending
Checking alignment and mounting
of LCD substrates
(Savings per channel compared with
existing products.)
100 mm
10
2 ch
1 ch
mm
Emitting
Receiving
Emitting
Receiving
Equipped with AND/OR control output.
Patent pending
Two types of control output possible with one
Sensor (AND/OR).
Compact PLCs and Sensor Controllers no
longer required.
Detection and front/back
discrimination of parts
Half the Space
Detection of bends in electronic
component leads
Compact PLC
or
Sensor Controller
Operation
indicator
Incident level
Channel 1
display
AND/OR
Operation
indicator
Incident level
AND/OR
Channel 2
display
Flexible control with Mobile Console.
The Mobile Console, which can also be used with the E3X-DA-S,
allows handheld operation of the Fiber Head even when it is
separated from the Amplifier.
50 mm
An impressive lineup of Digital Amplifiers to
handle a wide variety of applications.
A host of remarkable functions inside a compact body.
A complete lineup of Sensor Heads to handle an even wider
range of applications.
This is the platform for OMRON's sensing technology.
The Digital Amplifiers achieve a maximum response time of 48 µs.
Standard Models
Models with Cables
(E3X-DA11-S)
Models with Connectors
(E3X-DA6-S)
Equipped with OMRON's own easy-wiring connector.
Laser-type Smart Sensors
ZX-L Series
Linear Platform
Inductive Displacement
Smart Sensors
ZX-E Series
High-resolution sensing using laser
and magnetic technology
Advanced Models
(Representative model: E3X-DA6TW-S)
Twin-output Models
Two threshold values can be set. Judgement and self-diagnosis
output available.
External-input Models
The Sensor can be controlled externally. Equipped with counting function.
(Representative model:
E3X-DA6RM-S)
Smart Monitor
A wide variety of color variations available. Equipped
with APC circuit for more stable detection.
An improved lineup for smarter sensing
Mark-detecting Models and Infrared Models
Models with Green LED
Models with Blue LED
(Representative model:
E3X-DAG6-S)
(Representative model:E3X-DAB6-S)
Digital Fiber Sensors
E3X-DA-S/MDA Series
ON/OFF Platform
Infrared Models
NEW
A lineup of Smart Sensors that use
the eddy current method
Available Soon
(Representative model:E3X-DAH6-S)
Laser-type Photoelectric Sensors
with Separate Amplifiers
E3C-LDA Series
A common platform for Fiber Sensors
and Sensors with Separate Amplifiers
Two Amplifiers squeezed into a single, compact Unit.
AND/OR output available.
2-channel Models
(Representative model:E3X-MDA6)
Mobile Console
Maximize Fiber Amplifier potential using remote setting,
copying, and other functionality.
Refinement and a new dimension that
goes beyond superior performance.
Mobile Console
(E3X-MC11-S)
Photoelectric Sensors with Separate
Digital Amplifiers have joined the Smart
Sensor family.
CSM_E3X-DA-S_MDA_DS_E_3_1
New Models That Counteract the Decline
in Operating Rates Caused by Dust and Dirt
Advanced ATC Models
■ Active Threshold Control (ATC)
Automatically adjusts the threshold value.
■ ATC Error Output (Selectable Function)
Digital Laser Sensors
E3C-LDA@AT
Provides an error output when ATC does not adjust
the threshold value.
■ Alarm Output (Selectable Function)
Provides an alarm when maintenance is required.
Digital Fiber Sensors
E3X-DA@AT-S
Glass substrate detection though
view ports
Chip component detection
Technology
Intelligently Solve Problems Onsite with The
Sensing
ATC Function
A unique OMRON algorithm has been used that can determine whether
changes have been caused by dust and dirt or by differences in
workpieces.
The threshold value is automatically adjusted by the Sensor according
to changes to increase equipment operating rates by reducing sensing
errors. This is particularly true in applications requiring high-precision
detection.
■ Fixed Threshold Value (Previous Models)
2000
1800
An absolute value
is set for the threshold.
Digital incident
level
Engine for High-performance
OMRON's many years of accumulated sensing technology and highspeed digital processing techniques merge to meet onsite needs. Our
goal is high-performance sensing that provides easy, reliable application.
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution),
high-speed response of 48 µs (Fiber Sensors)
Fine Sensing
Adjustment is required for sensing errors.
Automatic Compensation for
External Changes
Active Threshold Control (ATC)
Consistent Emitter Power
Auto Power Control (APC)
Time
ON
Output
OFF
Sensing Engine
High Performance
■ Active Threshold Control (ATC Models)
2000
−10%
Digital incident
level
A relative value
is set for the threshold.
The value of the threshold is
adjusted every 30 s (see note) to prevent sensing errors.✽
Time
ON
Output
OFF
✽
The monitoring range is set in the Sensor according to the threshold value. The threshold value is adjusted according to changes
within this range.
Easy Operation
Easy-to-read Displays Even at a Distance
Intelligent Display
Eliminates the Need for Distance Mode Settings
Power Tuning
Ordering Information
■ Digital Fiber Sensor
Type
Appearance
Model
Functions
Pre-wired Models
ATC
NPN output
PNP output
E3X-DA11AT-S
E3X-DA41AT-S
E3X-DA6AT-S
E3X-DA8AT-S
ATC error output
Alarm output
Connector Models
■ Separate Digital Amplifier Laser Sensors
Type
Appearance
Pre-wired Models
Model
Functions
NPN output
ATC
PNP output
E3C-LDA11AT
E3C-LDA41AT
E3C-LDA6AT
E3C-LDA8AT
ATC error output
Alarm output
Connector Models
Ratings and Specifications
Model
Digital Fiber Sensors
Separate Digital Amplifier Laser Sensors
NPN output
E3X-DA11AT-S
E3X-DA6AT-S
E3C-LDA11AT
E3C-LDA6AT
PNP output
E3X-DA41AT-S
E3X-DA8AT-S
E3C-LDA41AT
E3C-LDA8AT
Type
Item
Super-high-speed mode
High-speed mode
Response
Standard mode
time
Operate or Reset: 80 µs
Operate or Reset: 100 µs
Operate or Reset: 250 µs
Operate or Reset: 250 µs
Operate or Reset: 1 ms
High-resolution mode
Operate or Reset: 4 ms
ATC
Active threshold control (used for output 1)
Functions I/O settings
Startup operation
The signal that is output can be selected (used for output 2): ATC error output
The operation when power is turned ON can be selected: No operation, PT, or PT + ATC
Note: Basic performance is the same as the Advanced Twin-output Sensors. Refer to E3C-LDA Datasheet (E338) and E3X-DA-S Datasheet (E336) for details.
Only differences from the Advanced Twin-output Sensors have been given above.
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
Authorized Distributor:
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
OMRON ASIA PACIFIC PTE. LTD.
Kyoto, 600-8530 Japan
83 Clemenceau Avenue,
Tel: (81)75-344-7068/Fax: (81)75-344-7107
#11-01, UE Square,
239920 Singapore
Regional Headquarters
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON EUROPE B.V.
OMRON CHINA CO., LTD. BEIJING OFFICE
Sensor Business Unit,
Room 1028, Office Building,
Carl-Benz-Str. 4, D-71154 Nufringen,
Beijing Capital Times Square,
Germany
No. 88 West Chang'an Road,
Tel: (49)7032-811-0/Fax: (49)7032-811-199
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 Note: Specifications subject to change without notice.
CSM_E3X-DA-S_MDA_DS_E_3_1
CSM_E3X-DA-S_MDA_DS_E_3_1
New Models That Eliminate Worries about
Digital Sensor Setting Mistakes
Limited-function Models: Simple and Easy
Easy and Reliable Digital Sensors
with the Same Detection Performance
as Previous Models
■ One-key, one-operation concept for easy operation.
■ Threshold value setting with direct operation performed
while monitoring the detection status.
Digital Fiber Sensors
E3X-DA@SE-S
■ Lock function to prevent operating errors through
unintentional operation.
Technology
The Simplest Digital Fiber Sensor
The
Sensing
Some people think that digital sensors with their advanced performance
are difficult to use, so we went back to the drawing board to rethink performance and functions.
Without changing basic functions like APC and digital displays, OMRON
created a Digital Fiber Sensor that can be used as easily as the familiar
sensors with sensitivity adjustment knobs.
OMRON's many years of accumulated sensing technology and highspeed digital processing techniques merge to meet onsite needs.
Our goal is high-performance sensing that provides easy, reliable
application.
Engine for High-performance
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution)
UP/DOWN Key
Threshold adjustment
Incident level
Fine Sensing
Consistent Emitter Power
Auto Power Control (APC)
Threshold value
High Performance
Sensing Engine
KEY LOCK Switch
OPERATION MODE Selector
TEACH Key
Threshold Teaching
With/Without Workpiece: Teaching is performed in two states.
Automatic: Teaching is performed by passing a workpiece.
Easy Operation
Easy-to-read Displays Even at a Distance
Intelligent Display
One Key, One Operation
Simple and easy direct operation
Ordering Information
Type
Model
Appearance
NPN output
PNP output
Pre-wired Models
E3X-DA11SE-S
E3X-DA41SE-S
Connector Models
E3X-DA6SE-S
E3X-DA8SE-S
Ratings and Specifications
Model
Digital Fiber Sensor
NPN output
E3X-DA11SE-S
E3X-DA6SE-S
PNP output
E3X-DA41SE-S
E3X-DA8SE-S
Type
Item
Light source (wavelength)
Red LED (650 nm)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p): 10% max.
Power consumption
960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.)
Control output
Load power supply: 26.4 VDC max., Open-collector output, Load current: 50 mA max. (Residual voltage: 1 V max.)
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection
Response time
Operate or Reset: 1 ms
Sensitivity setting
Teaching or manual adjustment
Auto power
High-speed control method for emission current
control
Functions
Mutual interference
Optical communications sync, possible for up to 10 Units
prevention
Indicators
Operation indicator (orange)
Digital displays
Twin digital displays (incident level + threshold)
Note: Basic performance is the same as the E3X-DA-S Series. Refer to the E3X-DA-S Datasheet (E336) for details.
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
Authorized Distributor:
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
OMRON ASIA PACIFIC PTE. LTD.
Kyoto, 600-8530 Japan
83 Clemenceau Avenue,
Tel: (81)75-344-7068/Fax: (81)75-344-7107
#11-01, UE Square,
239920 Singapore
Regional Headquarters
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON EUROPE B.V.
OMRON CHINA CO., LTD. BEIJING OFFICE
Sensor Business Unit,
Room 1028, Office Building,
Carl-Benz-Str. 4, D-71154 Nufringen,
Beijing Capital Times Square,
Germany
No. 88 West Chang'an Road,
Tel: (49)7032-811-0/Fax: (49)7032-811-199
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 Note: Specifications subject to change without notice.
CSM_E3X-DA-S_MDA_DS_E_3_1
Digital Fiber Sensors
E3X-DA-S/MDA
CSM_E3X-DA-S_MDA_DS_E_3_1
OMRON’s Next-generation Platform
for a Wide Range of Detection
• Features a Power Tuning function that optimizes light reception at
the press of a button.
• Combines newly developed 4-element LEDs with an APC circuit to
ensure stable, long-term LED performance.
• Utilizes OMRON’s innovative wire-saving connector.
• 2-channel models achieve the thinnest profile in the industry, at only
5 mm per channel.
• 2-channel models also offer AND/OR control output.
Be sure to read Safety Precautions on
page 15.
Features
Equipped with an Industry’s First Power Tuning (Optimum Light Setting) Function
The E3X-DA-S/MDA features a Power Tuning function that optimizes
power at the press of a button.
This function easily but securely resolves saturation due to short
sensing distances or insufficient incident light due to long sensing
distances.
In addition, the response speed does not change as mode selection
has tuned the power.
New proposal
Conventional
Incident level Threshold
High-speed mode
Incident
level Low
Short-range mode
Appropriate
Standard mode
Appropriate
Long-range mode
Saturation
Super-long-range mode
Saturation
Up to approx.
5 times
Press
Modeless
Up to approx. 1/25 times
Available without mode setting.
Press the MODE key once to
adjust high or low incident levels
to be appropriate.
Selected from various
power mode according to applications
Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit
Achieves Long-term Reliable Detection at the Highest Level in the Industry
Newly developed
3-element LEDs + APC
4-element LEDs + APC
Incident level
Conventional
Incident level
The long-term reliable detection at the highest level in the industry is
achieved with the innovative APC circuit whose performance is
proved by E3X-DA-N series and the newly developed high-power
LEDs (4-element type) to ensure super stable, long-term LED
performance.
Stable performance is always available without the ON/OFF setting of
an APC circuit.
Long-term
stability
No APC circuit
No APC circuit
Time
Time
OMRON’s Innovative Wire-saving Connector Inherited from the E3X-DA-N
Wire-saving Connector Model
Reduced Wiring and Space Requirements for Power Lines
Up to 16 amplifier units connectable
<When using 5 amplifier units>
No relay connector required
Clear
Optical
communications
Power supply pin
Master connector
Slave connector
The power is
supplied from a
master unit to
slave units via a
master connector.
7 lines
Relay connector installation work, cost and space are saved.
Output lines
Amplifier units with cables
Power line Only output lines
1. Greatly reduced wiring work
2. Improved space usability due to the unnecessity of relay
connectors
3. Simple stock management due to the unnecessity of
distinction between master and slave for amplifiers
Amplifier units with connectors
Power and output
lines are required
respectively.
15 lines
Power lines
The amplifier units with connectors supply the power to slave
connectors via a master connector. This offers three following
advantages.
Relay connector
1
E3X-DA-S/MDA
Models available for a wide variety of applications at manufacturing sites
Industry Leading Two Amplifiers Loaded in a Small Body
. . . . 2-channel models
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
Liquid crystal board installation and alignment check
20mm
Simpler Digital Fiber Sensors
10mm
2-channel models
E3X-MDA
. . . . Simple & Easy Single-function Models
UP/DOWN keys
Threshold value adjustment
Current value
Threshold value
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
Key lock switch
Operation mode
selection switch
TEACH key
Threshold value teaching
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
High-speed and High-resolution Analog Output Supports Wide Variety of Applications . . . .Advanced Analog
Output Models
Analog Control Output
High-speed and High Resolution
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Detection modes can be switched in accordance with applications.
High-speed response of 80 µs (super-high-speed mode) supports the
positioning controls that require high-speed control.
Sheet Displacement
ON/OFF
Analog
Area Output Function Area Judgment Is
Possible . . . .Advanced, Twin-output Models
Only one sensor is enough for area judgment for height or others that
has required multiple sensors.
Setting two threshold values allows easy output inside and outside
range.
Area Output
Tablet length detection
Incident
level
2000
Threshold
value 1
1000
Threshold
value 2
Time
Output
ON
OFF
Remote Input Function Sensors Controlled from Outside . . . .Advanced, External-
Sticker detection
input Models
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites . . . .Advanced ATC Models
OMRON’s unique algorithm is equipped to
Fixed Threshold Value Method (Conventional Models)
Corrected Threshold Value Method (ATC Models)
distinguish dust or dirt and the change of
Threshold value
2000
2000
−10%
1800
set as a relative
workpieces. Automatic correction of threshold
Threshold value
value
set as an
values by sensors in accordance with changes Incident level
Incident level
absolute value
(digital value)
(digital value)
prevents malfunctions and improves the
Threshold value is corrected every 30 seconds *
operating rates of machines. The ATC function
Malfunctions are prevented
Malfunction Adjustment is required
is especially effective for the applications that
Time
Time
require high-resolution detection.
ON
ON
Output
Output
OFF
OFF
* Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.
2
E3X-DA-S/MDA
Ordering Information
Amplifier Units
Amplifier Units with Cables (2 m) [Refer to Dimensions on page 17.]
Item
Appearance
Model
Functions
Single-function models
NPN output
---
Standard models
Green LED
Mark-detecting models
Blue LED
(multiple color light sources)
Infrared LED
Advanced models
Timer, Response speed change
PNP output
E3X-DA11SE-S 2M
E3X-DA41SE-S 2M
E3X-DA11-S 2M
E3X-DAG11-S 2M
E3X-DAB11-S 2M
E3X-DAH11-S 2M
E3X-DA41-S 2M
E3X-DAG41-S 2M
E3X-DAB41-S 2M
E3X-DAH41-S 2M
External-input
models
Remote setting, counter, differential oper- E3X-DA11RM-S 2M
ation
E3X-DA41RM-S 2M
Twin-output
models
Area output, self-diagnosis, differential
operation
E3X-DA11TW-S 2M
E3X-DA41TW-S 2M
ATC function
models
ATC (Threshold value automatic correction)
E3X-DA11AT-S 2M
E3X-DA41AT-S 2M
Analog output
models
Analog output models
E3X-DA11AN-S 2M
E3X-DA41AN-S 2M
AND/OR output
E3X-MDA11 2M
E3X-MDA41 2M
2-channel models
Amplifier Units with Connectors
Item
Appearance
Single-function models
Standard models
---
Green LED
Mark-detecting models
(multiple color light sources) Blue LED
Infrared LED
Advanced models
Model
Functions
Timer, Response speed change
NPN output
E3X-DA6SE-S
E3X-DA6-S
E3X-DAG6-S
E3X-DAB6-S
E3X-DAH6-S
PNP output
E3X-DA8SE-S
E3X-DA8-S
E3X-DAG8-S
E3X-DAB8-S
E3X-DAH8-S
External-input
models
Remote setting, counter, differential operation
E3X-DA6RM-S
E3X-DA8RM-S
Twin-output
models
Area output, self-diagnosis, differential
operation
E3X-DA6TW-S
E3X-DA8TW-S
ATC function
models
ATC (Threshold value automatic correction)
E3X-DA6AT-S
E3X-DA8AT-S
AND/OR output
E3X-MDA6
E3X-MDA8
2-channel models
Ratings and Specifications
Control output/input
Light source
Single-function models
Standard models
Markdetecting
models
Advanced
models
E3X-DA@G-S
3X-DA@B-S
E3X-DA@H-S
Twin-output
models
External-input
models
ATC function
models
ON/OFF
output
Input
Analog
output
Power
tuning
Timer
---
---
Functions
InterferDifferenence pretial detecvention
tion
counter
ATC
Red LED
1 ms
50 µs to
4 ms
Only
main
---
---
---
---
---
Green LED
Blue LED
Infrared LED
50 µs to
4 ms
Only
main
---
---
---
---
---
Only
main
Red LED
50 µs to
4 ms
80 µs to
4 ms
130 µs to
4 ms
80 µs to
4 ms
Analog output
2-channel models
Response
time
Red LED
130 µs to
4 ms
Main +
sub
(2 lines)
Only
main
Main +
main
(2 independent
lines)
(1 line)
-----
---
--(1 line)
---
---
---
---
---
---
---
3
E3X-DA-S/MDA
Amplifier Unit Connectors (Order Separately)
Note: Protector seals are provided as accessories. [Refer to Dimensions on page 19.]
Item
Cable
length
Appearance
No. of conductors
Model
3
E3X-CN11
4
E3X-CN21
1
E3X-CN12
2
E3X-CN22
Master Connector
2m
Slave Connector
Combining Amplifier Units and Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
Amplifier Unit
Model
NPN output
Single-function models E3X-DA6SE-S
Standard models
E3X-DA6-S
E3X-DAG6-S
Mark-detecting models
(multiple color light
E3X-DAB6-S
sources)
E3X-DAH6-S
Advanced models
2-channel models
Applicable Connector (Order Separately)
Master Connector
Slave Connector
PNP output
E3X-DA8SE-S
E3X-DA8-S
E3X-DAG8-S
+
E3X-CN11
E3X-CN12
E3X-CN21
E3X-CN22
E3X-DAB8-S
E3X-DAH8-S
E3X-DA6TW-S
E3X-DA6RM-S
E3X-DA6AT-S
E3X-MDA6
E3X-DA8TW-S
E3X-DA8RM-S
E3X-DA8AT-S
E3X-MDA8
When Using 5 Amplifier Units
Amplifier Units (5 Units)
Mobile Console (Order Separately)
Appearance
+
1 Master Connector + 4 Slave Connectors
[Refer to Dimensions on page 20.]
Model
Remarks
E3X-MC11-SV2
(model number of set)
Mobile Console with Head,
Cable, and AC adapter provided as accessories
E3X-MC11-C1-SV2
Mobile Console
E3X-MC11-H1
Head
E39-Z12-1
Cable (1.5 m)
Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Amplifier Units.
The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model.
Accessories (Order Separately)
Mounting Bracket [Refer to E39-L/F39-L/E39-S/E39-R.]
Appearance
Model
E39-L143
Quantity
1
End Plate [Refer to PFP-@.]
Appearance
Model
PFP-M
Quantity
1
4
E3X-DA-S/MDA
Ratings and Specifications
Refer to pages 17 to 20 for dimensions.
Amplifier Units
Item
Type
Single-function
models
Standard
models
Model
E3X-DA@SE-S
E3X-DA@-S
Mark-detecting models (multiple color light sources)
Green LED
Blue LED
Infrared LED
E3X-DAG@-S
E3X-DAB@-S
E3X-DAH@-S
Infrared LED
Green LED (525 nm) Blue LED (470 nm)
(870nm)
Light source (wavelength)
Red LED (635 nm)
Power supply voltage
Power consumption
12 to 24 VDC ±10%, ripple (p-p) 10% max.
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Reverse polarity for power supply connection, output short-circuit
Control output
Protection circuits
Super-highspeed mode
High-speed
Remode
sponse
time
Standard mode
High-resolution
mode
Sensitivity setting
Power tuning
Timer function
---
Operate: 48 µs, reset: 50 µs *1, *2
---
Operate/reset: 250 µs
Operate or reset: 1 ms
---
Operate or reset: 4 ms
Teaching or manual method
--Light emission power and reception gain, digital control method
Select from OFF-delay, ON-delay, or one-shot timer.
--1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
High-speed control method for emission current
control (APC)
Zero-reset
--Negative values can be displayed. (Threshold value is shifted.)
Initial reset
Settings can be returned to defaults as required.
Mutual interferPossible for up to 10 Units *3
ence prevention
Operation indicator
Display
Operation indicator (orange), Power Tuning indicator (orange)
(orange)
incident level +
Digital display
Select from incident level + threshold or other 6 patterns
threshold
Display orientation
--Switching between normal/reversed display is possible.
Ambient illumination
Incandescent lamp: 10,000 lux max.
Sunlight:
20,000 lux max.
(Receiver side)
Functions
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Materials
Cover
Accessories
Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
5
E3X-DA-S/MDA
Advanced models
Type External input mod- Twin output mod- ATC function mod- Analog output mod- 2-channel models
els
els
els
els
Item
Model
E3X-DA@RM-S
E3X-DA@TW-S
E3X-DA@AT-S
E3X-DA@AN-S
E3X-MDA@
Light source (wavelength) Red LED (635 nm)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
ON/OFF output
load current: 50 mA max.; residual voltage: 1 V max.
Control output
Voltage output: 1 to
5 VDC
(Connection load
10 kΩ min.)
Temperature characteristics
Con0.3%F.S./°C
trol
Response speed/reoutput Analog output
--peat accuracy
--Super-high-speed
mode:
80 µs/1.5%F.S.
High-speed mode:
250 µs/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
Remote control input
No-voltage input (contact/non-contact) *1
Protection circuits
Reverse polarity for power supply connection, output short-circuit
Super-highOperate: 48 µs,
Operate or reset:
Operate or reset:
Operate or reset:
Operate or reset:
speed mode
reset: 50 µs *2, *3, *4 80 µs *2
130 µs *2
80 µs *2
130 µs *2, *5
High-speed
Operate or reset:
ReOperate or reset: 250 µs
450 µs
sponse mode
time
Standard mode Operate or reset: 1ms
High-resolution
Operate or reset: 4ms
mode
Sensitivity setting
Teaching or manual method
Power tuning
Light emission power and reception gain, digital control method
Switchable between single edge and double edge detection mode
Differential deSingle edge: Can be set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms.
--tection
Double edge: Can be set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
Timer function
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1 s-increments)
Automatic powHigh-speed control method for emission current
er control (APC)
Functions
Zero-reset
Negative values can be displayed. (Threshold value is shifted.)
Initial reset
Settings can be returned to defaults as required.
Mutual interferPossible for up to 9
Possible for up to 10 Units *6
ence prevention
Units (18 channels) *7
Switchable between
up counter and down
Counter
counter.
--Set count:
0 to 9,999,999
*1. Input Specifications
NPN
PNP
Contact input (relay or switch)
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
Non-contact input (transistor)
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
*2. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*3. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*4. When counter is enabled: 80 µs for operate and reset respectively.
*5. When differential output is selected for the output setting, the second channel output is 200 µs for operation and reset respectively.
*6. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*7. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
6
E3X-DA-S/MDA
Type
Item
Functions
External input
models
Model
E3X-DA@RM-S
External input setting (Select from
teaching, power tunI/O setting
ing, zero reset, light
OFF, or counter reset.)
Advanced models
Twin-output mod- ATC function modAnalog output
els
els
models
E3X-DA@TW-S
E3X-DA@AT-S
E3X-DA@AN-S
Output setting (SeOutput setting
lect from channel 2
Analog output set(Select from channel
output, area output,
ting (offset voltage
2 output, area outself-diagnosis outadjustable)
put, or self-diagnoput, or ATC error
sis.)
output)
Display
Operation indicator
(orange), Power
Operation indicator for channel 1 (orange),
Tuning indicator (or- Operation indicator for channel 2 (orange)
ange)
Digital display
Select from incident
level + threshold or
other 7 patterns
Display orientation
Ambient illumination
(Receiver side)
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Materials
Cover
Accessories
Select from incident level + threshold or other 6 patterns
Model
E3X-MDA@
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Operation indicator
for channel 1 (orange), Operation indicator for channel 2
(orange)
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
Switching between normal/reversed display is possible.
Incandescent lamp: 10,000 lux max.
Sunlight:
20,000 lux max.
Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
Amplifier Unit Connectors
Item
Operation indicator
(orange),
Power Tuning indicator (orange)
2-channel models
Mobile Console
E3X-CN11/21/22
E3X-CN12
Item
Model
E3X-MC11-SV2
Rated current
2.5 A
Rated voltage
50 V
Applicable
Sensors
Contact resistance
20 mΩ max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.)
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Power supply
voltage
Charged with AC adapter
No. of insertions
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Connection
method
Connected via adapter
Polybutylene terephthalate (PBT)
Weight
Approx. 580 g (Console
(packed state) only: 120 g)
Mate- Housing
rials
Contacts
Weight
(packed state)
Phosphor bronze/gold-plated nickel
Approx. 55 g
Approx. 25 g
Refer to Instruction Manual provided with
the Mobile Console for details.
7
E3X-DA-S/MDA
Sensing Distance
Through-beam Models
(Unit: mm)
Model
Type
Flexible
(new
standard)
Standard
models
Standard
Breakresistant
Specialbeam
models
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R)
E32-T14LR/E32-T15YR/E32-T15ZR
E32-T21R/E32-T22R/E32-T222R/
E32-T25XR/E32-TC200FR(F4R)
E32-T24R/E32-T25YR/E32-T25ZR
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4)
E32-T14L/E32-T15Y/E32-T15Z
E32-TC200A
E32-TC200E/E32-T22/E32-T222/
E32-T25X/E32-TC200F(F4)
E32-T24/E32-T25Y/E32-T25Z
E32-T11/E32-T12B/E32-T15XB
E32-T21/E32-T221B/E32-T22B
E32-T25XB
Fluorine
coating
E32-T11U
Longdistance,
high power
E32-T17L
E32-TC200 + E39-F1
E32-T11R + E39-F1
E32-T11 + E39-F1
E32-T14
E32-T11L/E32-T12L
E32-T11L + E39-F2
E32-T11R + E39-F2
E32-T11 + E39-F2
E32-T21L/E32-T22L
Ultracompact,
ultrafine
sleeve
E3X-DA@-S
E3X-MDA@
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
700
530
350
140
450
350
230
140
270
210
130
50
170
130
85
50
160
130
75
30
100
75
50
30
60
50
25
10
35
27
18
10
1,000
760
500
200
650
500
330
200
600
900
460
680
300
450
120
180
390
580
300
450
200
300
120
180
270
220
125
50
170
130
85
50
160
900
240
180
130
680
200
150
75
450
110
85
30
180
45
35
100
580
150
125
70
450
110
95
45
300
70
60
30
180
45
35
900
680
450
180
580
450
300
180
4,000 13,000 10,000
1,500 4,000 3,700
970 3,100 2,400
930 3,000 2,300
900 2,900 2,200
350 1,100
870
180
600
520
100
330
260
160
530
430
100
340
260
6,500
2,400
1,600
1,500
1,450
580
340
170
280
170
4,000
1,500
970
930
900
350
180
100
160
100
20,000*1 20,000*1 10,000
4,000*2 4,000*2 2,600
4,000*2 3,700 2,400
4,000*2 3,600 2,300
4,000*2 3,400 2,250
1,700 1,330
870
910
800
500
520
400
250
820
660
430
540
440
250
E32-T223R
160
130
75
30
110
85
55
30
E32-T33-S5
53
44
25
10
35
28
18
10
E32-T333-S5
12
10
6
4
8
6
5
4
E32-T334-S5
6
5
3
2
4
3
2
2
E32-T22S
2,500
1,900
1,250
500
1,600
1,250
830
500
E32-T24S
1,750
1,300
870
350
1,100
870
580
350
1,100
1,500
980
1,300
1,700
2,300
3,700
750
840
1,100
750
1,000
1,300
1,800
2,800
610
560
750
480
650
850
1,150
1,850
350
220
300
190
260
340
450
740
140
730
970
600
800
1,100
1,400
2,400
470
560
750
480
650
860
1,100
1,800
360
370
500
320
430
570
730
1,200
240
220
300
190
260
340
450
740
140
Fine beam
E32-T16PR
E32-T16P
E32-T16JR
E32-T16J
Area sensing
E32-T16WR
E32-T16W
E32-T16
E32-M21
*1. The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
8
E3X-DA-S/MDA
Model
Type
Heatresistant
Environment
resistant
models
Chemical
resistant
Vacuum
resistant
E3X-DA@-S
Highresolution
mode
1,000
300
360
600
4,000
1,750
600
2,500
4,000*
500
1,800
920
260
1,350
210
660
630
E32-T51
E32-T54
E32-T81R-S
E32-T61-S + E39-F2
E32-T61-S + E39-F1
E32-T84S-S
E32-T61-S
E32-T11F
E32-T12F
E32-T14F
E32-T51F
E32-T81F-S
E32-T51V
E32-T51V + E39-F1V
E32-T54V
E32-T54V + E39-F1V
E32-T84SV
Standard
mode
Highspeed
mode
760
230
280
450
3,400
1,300
450
2,000
3,000
400
1,400
700
200
1,000
130
500
480
500
150
180
300
2,200
870
300
1,300
2,000
250
900
460
130
680
100
330
320
E3X-MDA@
Superhighspeed
mode
200
60
70
120
900
350
120
520
800
100
350
190
50
260
35
180
130
Highresolution
mode
650
190
230
390
3,000
1,100
390
1,600
2,600
320
1,190
600
170
850
110
420
410
Standard
mode
Highspeed
mode
500
150
180
300
2,200
870
300
1,300
2,000
250
920
460
130
650
85
320
310
330
100
120
200
1,450
570
200
850
1,300
160
600
300
85
430
55
210
200
Superhighspeed
mode
200
60
70
120
900
350
120
520
800
100
350
190
50
260
35
180
130
* The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm.
Reflective Models
(Unit: mm)
Model
Type
Flexible
(new standard)
Standard
models
Standard
Breakresistant
Fluorine
coating
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R)
E32-D14LR
E32-D15YR/E32-D15ZR
E32-D211R/E32-D21R/E32-D22R/
E32-D25XR/E32-DC200FR(F4R)
E32-D24R
E32-D25YR/E32-D25ZR
E32-DC200/E32-D15X/
E32-DC200B(B4)
E32-D12
E32-D14L
E32-D15Y/E32-D15Z
E32-D211/E32-DC200E/E32-D22/
E32-D25X/E32-DC200F(F4)
E32-D24
E32-D25Y/E32-D25Z
E32-D11/E32-D15XB
E32-D21B/E32-D221B
E32-D21/E32-D22B
E32-D25XB
E32-D11U
E3X-DA@-S
Highresolution
mode
Standard
mode
300
170
120
80
70
45
40
50
E3X-MDA@
SuperHighhighspeed
speed
mode
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
50
170
120
80
50
30
26
14
12
45
40
33
29
22
19
14
12
30
20
8
30
22
14
8
26
14
15
8
10
5
4
2
15
8
10
5
6
3.3
4
2
500
300
200
90
300
210
130
90
400
200
170
230
110
100
160
80
65
70
36
30
230
110
100
160
80
70
100
50
45
70
36
30
130
80
50
22
80
55
35
22
50
35
300
110
50
85
30
20
170
70
30
50
20
12
120
45
20
30
8
6
50
20
8
15
30
20
170
70
30
50
22
14
125
50
22
35
14
9
80
30
14
23
8
6
50
20
8
15
300
170
120
50
170
125
80
50
9
E3X-DA-S/MDA
Model
Type
E32-D16
Long
distance,
high power
Ultracompact, ultrafine
sleeve
Specialbeam
models
Environmentresistant
models
Chemicalresistant
40 to
700
40 to
450
40 to
240
Standard
mode
Highspeed
mode
Superhighspeed
mode
40 to
600
40 to
490
40 to
300
40 to
240
400
260
110
400
270
180
110
E32-D21L/E32-D22L
210
130
80
35
130
85
55
35
E32-D33
25
16
10
4
16
10
6
4
E32-D331
5
3
2
0.8
3
2
1.3
0.8
E32-C41 + E39-F3A-5
E32-C31 + E39-F3A-5
E32-C41 + E39-F3B
E32-C31 + E39-F3B
E32-C31 + E39-F3C
Area sensing E32-D36P1
Heatresistant
40 to
1,000
Highresolution
mode
650
E32-C42 + E39-F3A
Coaxial/small
spot
E32-D32 + E39-F3A
Convergentreflective
Standard
mode
E3X-MDA@
SuperHighhighspeed
speed
mode
mode
E32-D11L
E32-CC200R
E32-CC200
E32-D32L
E32-C31/E32-D32
Retroireflective
E3X-DA@-S
Highresolution
mode
250
150
100
45
150
105
65
45
500
300
200
90
300
210
140
90
250
150
100
45
150
100
65
45
120
75
50
22
75
50
30
22
Spot diameter variable in the range 0.1 to 0.6 mm at distances in the
range 6 to 15 mm.
Spot diameter variable in the range 0.5 to 1mm at distances in the range
6 to 15 mm.
0.1-mm dia. spot at a distance of 7 mm.
0.5-mm dia. spot at a distance of 7 mm.
0.2-mm dia. spot at a distance of 17 mm.
0.5-mm dia. spot at a distance of 17 mm.
Spot diameter of 4 mm max. at distances in the range 0 to 20 mm.
250
150
100
45
150
100
65
45
E32-R21 + E39-R3 (provided)
10 to 250
E32-R16 + E39-R1 (provided)
150 to 1,500
E32-L25/E32-L25A
E32-L24S
E32-L24L
E32-L25L
E32-L86
E32-D51
E32-D81R-S
E32-D61-S
E32-D73-S
3.3
0 to 4
2 to 6 (center 4)
5.4 to 9 (center 7.2)
4 to 10
160
72
230
400
230
165
110
72
150
90
60
27
90
63
40
27
100
60
40
18
60
40
25
18
E32-D12F
160
95
65
30
95
70
45
30
E32-D14F
70
40
30
10
40
28
18
10
10
E3X-DA-S/MDA
Application-specific Models
(Unit: mm)
Model
E3X-DA@-S
Highresolution
mode
Type
Label
detection
Liquid-level
detection
Standard
mode
E32-G14
E32-T14
Wafer
mapping
Highspeed
mode
Superhighspeed
mode
4,000*
3,400
2,250
900
2,900
2,200
1,450
900
Applicable tube: Transparent tube with a diameter in the range 8 to 10
mm and a recommended wall thickness of 1 mm
E32-D36T
Applicable tube: Transparent tube (no restriction on diameter)
E32-A01
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm
and a recommended wall thickness of 1 mm
Applicable tube: Transparent tube with a diameter in the range 6 to 13
mm and a recommended wall thickness of 1 mm
Liquid-contact model
E32-L16-N
0 to 15
0 to 12
0 to 15
0 to 12
E32-A08
10 to 20
---
10 to 20
---
E32-A07E1(E2)
15 to 25
---
15 to 25
---
E32-L66
Glasssubstrate
Mapping
Standard
mode
10
E32-D82F1(F2)
Glasssubstrate
alignment
Highresolution
mode
E32-L25T
E32-A02
Applicationspecific
models
E3X-MDA@
SuperHighhighspeed
speed
mode
mode
5 to 18
5 to 16
---
5 to 18
5 to 14
---
E32-A09/E32-A09H
15 to 38
---
15 to 38
---
E32-A09H2
20 to 30
---
20 to 30
---
E32-A03/E32-A03-1
1,150
890
600
250
750
580
380
250
E32-T24S
1,750
1,300
870
350
1,100
870
580
350
460
340
225
100
300
220
145
100
E32-A04/E32-A04-1
* The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm.
11
E3X-DA-S/MDA
Green, Blue, and Infrared Light Sources
(Unit: mm)
Model
Type
Throughbeam
models
Reflective
models
Applicationspecific
models
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R)
E32-T14LR/E32-T15YR/E32-T15ZR
Standard
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4)
E32-T14L/E32-T15Y/E32-T15Z
Special beam E32-T11L/E32-T12L
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R)
E32-D14LR
E32-D15YR/E32-D15ZR
Standard
E32-DC200/E32-D15X/
E32-DC200B(B4)
E32-D14L
E32-D15Y/E32-D15Z
E32-D11L
E32-CC200R
Special beam E32-CC200
E32-D32L
E32-C31/E32-D32
Label
detection
E32-T14
E32-G14
E3X-DAG@-S/DAB@-S
HighSuperStan- Highresohighdard speed
lution
speed
mode mode
mode
mode
E3X-DAH@-S
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
65
50
35
30
280
190
130
55
25
20
22
12
100
75
80
21
100
75
50
45
400
280
180
80
50
150
40
120
30
85
25
75
240
700
160
490
110
320
45
140
17
14
10
8
120
90
60
21
4.4
4.2
3.5
3.3
2.5
2.2
2.2
2.1
32
28
24
20
16
13
5.5
5
32
25
16
16
200
150
100
35
11
10
44
15
32
15
7.5
9
8
35
12
25
12
6
6
5.5
22
8
16
8
4
5.5
5
22
7.5
16
7.5
3.5
80
65
260
100
200
100
50
60
50
190
75
150
75
37
40
33
130
50
100
50
25
14
11
45
17
35
17
8.5
320
260
220
160
1,800
1,200
820
360
10
10
Refer to E32 Series for details on Fiber Units.
12
E3X-DA-S/MDA
Output Circuit Diagrams
NPN Output
Operation
mode
Model
Light-ON
E3X-DA11-S
E3X-DA6-S
E3X-DAG11-S
E3X-DAG6-S
E3X-DAB11-S
E3X-DAB6-S
E3X-DA11SE-S
E3X-DA6SE-S
Operation
selector
Timing charts
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
Output circuit
LIGHT ON
(L-ON)
Power
tuning
indicator
(orange)
(Between brown and black leads)
Dark-ON
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
Reset
(relay)
Operation indicator
(orange)
Display
Brown
Black Load
Control output
Photoelectric
Sensor
main
circuit
12 to
24 VDC
Blue
DARK ON
(D-ON)
(Between brown and black leads)
Light-ON
E3X-DA11TW-S
E3X-DA6TW-S
E3X-MDA11
E3X-MDA6
E3X-DA11AT-S
E3X-DA6AT-S
CH1/ Incident light
CH2 No incident light
Operation ON
indicator OFF
(orange)
ON
Output
transistor OFF
Operate
Load
Reset
(relay)
LIGHT ON
(L-ON)
Display
Operation indicator
(orange)
ch 1
Brown
Load
Black
Control
output 1
Photoelectric
Sensor
main
circuit
(Between brown and black leads)
Dark-ON
Operation indicator
(orange) ch 2
CH1/ Incident light
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Operate
Load
(relay)
Reset
Load
Orange
Control
output 2
12 to
24 VDC
Blue
DARK ON
(D-ON)
(Between brown and black leads)
Light-ON
E3X-DA11RM-S
E3X-DA6RM-S
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
(relay)
Reset
LIGHT ON
(L-ON)
Power
tuning
indicator
(orange)
(Between brown and black leads)
Dark-ON
g
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
Reset
(relay)
Operation indicator
(orange)
Display
Brown
Load
Black
Control output
Photoelectric
Sensor
main
circuit
Orange
DARK ON
(D-ON)
External
input
12 to
24 VDC
Blue
(Between brown and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
LIGHT ON
(L-ON)
ON
Output
OFF
transistor
Load
Operate
(relay)
Reset
(Between brown and black leads)
E3X-DA11AN-S
Display
Power
tuning
indicator
(orange)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Load
Operate
(relay)
Reset
Operation indicator
(orange)
Brown
Load
Black
Control output
Analog
Orange
output
models
Photoelectric
Sensor
main
circuit
12 to
24 VDC
Load 10kΩmin
Blue
DARK ON
(D-ON)
(Between brown and black leads)
Note: 1. The ON/OFF regions when areas settings are used with the E3XDA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for
channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for
channels 1 and 2.
2. Timing Charts for Timer Function Settings (T: Set Time)
ON delay
OFF delay
One-shot
Incident light
Incident light
Incident light
No incident light
No incident light
No incident light
L-ON
D-ON
T
ON
OFF
ON
OFF
L-ON
T
D-ON
T
ON
OFF
ON
OFF
L-ON
T
D-ON
T
ON
OFF
T
3. Control Output (AND, OR, Sync) and Timing Chart for Timer Settings
(T: Set Time)
ON
OFF
ON
CH2
OFF
OUT ON
(AND) OFF
OUT ON
(OR) OFF
OUT ON
(sync) OFF
CH1
ON
OFF
ON
CH2
OFF
ON delay ON
(AND) OFF
OFF delay ON
(AND) OFF
One-shot ON
(AND) OFF
CH1
T
T
T
T
ON
OFF
13
E3X-DA-S/MDA
PNP Output
Model
Operation mode
Timing chart
Operation
selector
Output circuit
Incident light
E3X-DA41-S
E3X-DA8-S
E3X-DAG41-S
E3X-DAG8-S
E3X-DAB41-S
E3X-DAB8-S
E3X-DA41SE-S
E3X-DA8SE-S
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
LIGHT ON
(L-ON)
Operation indicator
(orange)
Display
OFF
Power
tuning
indicator
(orange)
Operate
Reset
(Between blue and black leads)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
Photoelectric
Sensor
main
circuit
DARK ON
(D-ON)
Brown
Control
output
Black
12 to
24 VDC
Load
Blue
(Between blue and black leads)
Light-ON
E3X-DA41TW-S
E3X-DA8TW-S
E3X-MDA41
E3X-MDA8
E3X-DA41AT-S
E3X-DA8AT-S
Incident light
CH1/
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
OFF
LIGHT ON
(L-ON)
Operation indicator
(orange)
ch 1
Display
Operate
Reset
Photoelectric
Sensor
main
circuit
(Between blue and black leads)
Incident light
Dark-ON
Operation indicator
(orange) ch 2
CH1/
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
Brown
Control
output 1
Black
12 to
24 VDC
Control
output 2
Orange
Load
Load
DARK ON
(D-ON)
Blue
OFF
Operate
Reset
(Between blue and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
E3X-DA41RM-S
E3X-DA8RM-S
LIGHT ON
(L-ON)
Display
Power
tuning
indicator
(orange)
(Between blue and black leads)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
Output
transistor
Load
(relay)
ON
Operation indicator
(orange)
Photoelectric
Sensor
main
circuit
Brown
Orange
Black
Blue
External
input
Control
output
12 to
24 VDC
Load
DARK ON
(D-ON)
OFF
Operate
Reset
(Between blue and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
LIGHT ON
(L-ON)
OFF
Power
tuning
indicator
(orange)
Operate
Reset
(Between blue and black leads)
E3X-DA41AN-S
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
Display
Operation indicator (orange)
Photoelectric
Sensor
main
circuit
Brown
Analog
Orange output models
12 to
Control
24 VDC
output
Black
Blue
Load
Load 10kΩmin
DARK ON
(D-ON)
OFF
Operate
Reset
(Between blue and black leads)
Note: The ON/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
14
E3X-DA-S/MDA
Nomenclature
Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Operation Keys
Function setting operations
UP
Lock lever
Locks the fiber.
DOWN
Main Display (Red)
Incident level, function, etc.
Lock lever
Locks the fiber.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
UP
DOWN
MODE
MODE
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Power Tuning Indicator
ON: Power tuning is set.
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Mode Selector
Use to select SET or RUN mode.
Operation indicator for
channel 1 (orange)
ON when output is ON.
OFF when output is OFF.
Channel Selector
Use to switch between channels
Operation indicator for
1 and 2.
channel 2 (orange)
Mode Selector
ON when output is ON.
Use to select SET or RUN mode.
OFF when output is OFF.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Press down
Lever
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
● Mounting
Connecting and Disconnecting Connectors
Remove
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Insert
2. Attach the protector seals (provided as accessories) to the sides of
master and slave connectors that are not connected.
Seal
Seal
Note: Attach the seals to the sides with grooves.
Click into place
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Note: 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
15
E3X-DA-S/MDA
Fibers That Cannot Be Free-Cut (with Sleeves)
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
9 mm
13 mm
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
End Plate
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Protective cover
20 mm
Locked
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Unlocked
Note: 1. To maintain the fiber properties, confirm that the lock is released
before removing the fibers.
2. Be sure to lock or unlock the lock button within an ambient
temperature range between −10°C and 40°C.
● Adjusting
Mutual Interference Protection Function
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e.,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
Lock button
Protective cover
Locked
Unlocked
Insertion position
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Fiber insertion mark
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Fiber
9 mm
Fibers with E39-F9 Attachment
● Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series
Amplifier Units.
Fiber Unit
9 mm
13 mm
16
E3X-DA-S/MDA
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Amplifier Units
Amplifier Units with Cables
E3X-DA11-S
E3X-DA41-S
E3X-DAG11-S
E3X-DAG41-S
E3X-DAB11-S
E3X-DAB41-S
E3X-DA11RM-S
E3X-DA41RM-S
E3X-DA11TW-S
E3X-DA41TW-S
E3X-DA11SE-S
E3X-DA41SE-S
E3X-DA11AT-S
E3X-DA41AT-S
E3X-DA11AN-S
E3X-DA41AN-S
E3X-MDA11
E3X-MDA41
Operation indicator
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Main display
Sub-display
Vinyl-insulated round cable
Standard length: 2 m*
CH2
CH1
(E3X-DA@-S)
(E3X-MDA@)
*Cable Specifications
E3X-DA11-S
-DA41-S
-DAG11-S
-DAG41-S
-DAB11-S
-DAB41-S
4-dia., 3-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
E3X-DA11TW-S
-DA41TW-S
-DA11RM-S
-DA41RM-S
4-dia., 4-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter, 1.1 mm)
E3X-MDA11
-MDA41
4-dia., 2-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
With Mounting Bracket Attached
3.9 × 3 = 11.7
32.8
29.8
3.9 × 3
15.1
=11.7
12.15
3.25
* The Mounting Bracket can also
be used on this side.
4.3
10
10
A*
70
Two, 2.4 dia.
4.5
32
Four, 2.4 dia.
7
4.5
4.5
5.65
5.65
(E3X-DA@-S)
9.9
12.5
3.4
(E3X-MDA@)
28.1
18.7
16
34.8
Hole for optical communications
44.3
Two, 3.2 dia. holes
3.4
Two, M3
16
28.1
Mounting Bracket (E39-L143)
SUS304 stainless steel
4.4
16
Mounting Holes
17
E3X-DA-S/MDA
Amplifier Units with Connectors
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
E3X-DAG8-S
E3X-DAB6-S
E3X-DAB8-S
E3X-DA6RM-S
E3X-DA8RM-S
CH2
E3X-DA6TW-S
E3X-DA8TW-S
E3X-DA6SE-S
E3X-DA8SE-S
E3X-DA6AT-S
CH1
E3X-DA8AT-S
(E3X-DA@-S)
E3X-MDA6
E3X-MDA8
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Operation indicator
Main display
Sub-display
(E3X-MDA@)
*1 The Mounting Bracket can also be
used on this side.
*2 Cable Diameters
With Mounting Bracket Attached
3.9 × 3 = 11.7
32.8
29.8
3.9 × 3
15.1
=11.75
12.15
3.25
10
10
A *1
E3X-CN22
(2 conductors)
E3X-CN21
(4 conductors)
E3X-CN11
(3 conductors)
4.0-mm
dia.
E3X-CN12
(1 conductor)
2.6-mm
dia.
70
4.3
8.1
Connector
Two, 2.4 dia.
Four, 2.4 dia.
4.5
Dia. A*2 32
7
4.5
4.5
5.65
5.65
(E3X-DA@-S)
9.9
12.95
3.4
(E3X-MDA@)
28.1
18.7
16
34.8
44.3
Two, 3.2-dia. holes
3.4
Two, M3
Hole for optical communications
Mounting Bracket (E39-L143)
SUS304 stainless steel
4.4
16
Mounting Holes
28.1
16
18
E3X-DA-S/MDA
Amplifier Unit Connectors
Master Connectors
E3X-CN11
E3X-CN21
2,000+500
10
6
2.9
2.6
10.7
6.8
4
*
4 dia.
14.4
6
0.8
8.4
15.1
30±2
10±2
50+50
*E3X-CN11: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave Connectors
E3X-CN12
E3X-CN22
2,000+500
10
6
10.7
6.8
2.9
4
2.6
*
E3X-CN12: 2.6 dia.
E3X-CN22: 4 dia.
14.4
6
0.8
3
8.4
15.1
30±2
10±2
50+50
*E3X-CN12: 2.6-dia. vinyl-insulated round cable with 1 conductor (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
19
E3X-DA-S/MDA
Mobile Console
E3X-MC11-SV2
Mobile Console
AC adapter jack
Menu indicators
22
Mobile Console Head
Communications jack
Optical communications connection indicator
Communications jack
52.8
10
20
Channel indicator
(38.2)
13.1
16.3
28.8
31.8
13.2
Sensor
operation
indicator
1.2
5.1
12.3
Main display
17.3
24.3
Channel
buttons
27.7
30.3
Sub-display
9.9
136
UP key
Optical communications position
RIGHT key
M5 ball plunger
LEFT key
31.2
36.7
51.3
5.6
ESC/PWR key
DOWN
key
ENT key
Operation keys
Battery
indicators
50
Refer to E32 Series for details on Fiber Units.
20
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.