EGP50A thru EGP50G Vishay General Semiconductor Glass Passivated Ultrafast Rectifier FEATURES • Cavity-free glass-passivated junction ® • Ultrafast reverse recovery time • Low forward voltage drop • Low leakage current d* e t n e Pat • Low switching losses, high efficiency • High forward surge capability GP20 *Glass Encapsulation technique is covered by Patent No. 3,996,602, brazed-lead assembly to Patent No. 3,930,306 • Solder dip 260 °C, 40 s • Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC TYPICAL APPLICATIONS For use in high frequency rectification and freewheeling application in switching mode converters and inverters for consumer, computer and telecommunication. PRIMARY CHARACTERISTICS IF(AV) 5.0 A VRRM 50 V to 400 V IFSM 150 A trr 50 ns VF 0.95 V, 1.25 V TJ max. 150 °C MECHANICAL DATA Case: GP20, molded epoxy over glass body Epoxy meets UL 94V-0 flammability rating Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD22-B102 E3 suffix for consumer grade, meets JESD 201 class 1A whisker test, HE3 suffix for high reliability grade (AEC Q101 qualified), meets JESD 201 class 2 whisker test Polarity: Color band denotes cathode end MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL EGP50A EGP50B EGP50C EGP50D EGP50F EGP50G UNIT Maximum repetitive peak reverse voltage VRRM 50 100 150 200 300 400 V Maximum RMS voltage VRMS 35 70 105 140 210 280 V Maximum DC blocking voltage VDC 50 100 150 200 300 400 V Maximum average forward rectified current 0.375" (9.5 mm) lead length at TL = 55 °C IF(AV) 5 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load IFSM 150 A TJ, TSTG - 65 to + 150 °C Operating and storage temperature range Document Number: 88585 Revision: 20-Aug-07 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 EGP50A thru EGP50G Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage 5.0 A SYMBOL EGP50A EGP50B EGP50C EGP50D EGP50F EGP50G UNIT VF 0.95 1.25 V TA = 25 °C TA = 125 °C IR 5.0 50 µA Maximum reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 50 ns Typical junction capacitance 4.0 V, 1 MHz CJ Maximum DC reverse current at rated DC blocking voltage 95 75 pF THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL EGP50A EGP50B EGP50C EGP50D EGP50F EGP50G UNIT RθJA RθJL Typical thermal resistance (1) 20 5.0 °C/W Note: (1) Thermal resistance from junction to ambient, and from junction to lead at 0.375" (9.5 mm) lead length, P.C.B. mounted ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE EGP50G-E3/54 1.01 54 1400 13" diameter paper tape and reel EGP50G-E3/73 1.01 73 1000 Ammo pack packaging EGP50GHE3/54 (1) 1.01 54 1400 13" diameter paper tape and reel EGP50GHE3/73 (1) 1.01 73 1000 Ammo pack packaging Note: (1) Automotive grade AEC Q101 qualified RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 175 Resistive or Inductive Load Peak Forward Surge Current (A) Average Forward Rectified Current (A) 6.0 5.0 4.0 Copper Heatsinks 3.0 2.0 TL L 0.375" (9.5 mm) Lead Length 1.0 TJ = TJ Max. 8.3 ms Single Half Sine-Wave 150 125 100 75 50 25 0 0 0 25 50 75 100 125 150 175 1 10 100 Lead Temperature (°C) Number of Cycles at 60 Hz Figure 1. Maximum Forward Current Derating Curve Figure 2. Maximum Non-Repetitive Peak Forward Surge Current www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88585 Revision: 20-Aug-07 EGP50A thru EGP50G Vishay General Semiconductor 210 Pulse Width = 300 µs 1 % Duty Cycle 10 TJ = 150 °C 1 TJ = 25 °C 0.1 120 90 60 EGP50A - EGP50D EGP50F & EGP50G 0 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 0.1 1 10 100 1000 Instantaneous Forward Voltage (V) Reverse Voltage (V) Figure 3. Typical Instantaneous Forward Characteristics Figure 5. Typical Junction Capacitance 100 100 Transient Thermal Impedance (°C/W) Instantaneous Reverse Leakage Current (µA) 150 30 EGP50A - EGP50D EGP50F & EGP50G 0.01 0.2 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p 180 Junction Capacitance (pF) Instantaneous Forward Current (A) 100 TJ = 150 °C 10 TJ = 125 °C 1 TJ = 75 °C 0.1 TJ = 25 °C 0.01 0.001 0 20 40 60 80 10 1 0.1 0.01 100 0.1 1 10 100 Percent of Rated Peak Reverse Voltage (%) t - Pulse Duration (s) Figure 4. Typical Reverse Leakage Characteristics Figure 6. Typical Transient Thermal Impedance PACKAGE OUTLINE DIMENSIONS in inches (millimeters) GP20 1.0 (25.4) MIN. 0.210 (5.3) 0.190 (4.8) DIA. 0.375 (9.5) 0.285 (7.2) 1.0 (25.4) MIN. 0.042 (1.07) 0.037 (0.94) DIA. Document Number: 88585 Revision: 20-Aug-07 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1