SMSC EMC6D103S Fan control device with high frequency pwm support and hardware monitoring feature Datasheet

EMC6D103S
Fan Control Device with
High Frequency PWM
Support and Hardware
Monitoring Features
PRODUCT FEATURES
„
„
„
Datasheet
3.3 Volt Operation (5 Volt Tolerant Input Buffers)
SMBus 2.0 Compliant Interface (Fixed, not
Discoverable) with Three Slave Address Options
Fan Control
— PWM (Pulse width Modulation) Outputs (3)
— Fan Tachometer Inputs (4)
— Programmable automatic fan control based on
temperature
— Backwards compatible with fans requiring lower
frequency PWM drive
— High frequency fan support for 4 wire fans
— One fan can be controlled from as many as 3
temperature zones
— Fan ramp rate control for acoustic noise reduction
„
„
Temperature Monitor
— Monitoring of Two Remote Thermal Diodes (+/- 3 deg
C accuracy)
— Internal Ambient Temperature Measurement
— Limit Comparison of all Monitored Values
— Interrupt Pin for out-of-limit Temperature Indication
„
Voltage Monitor
— Monitors VCC and VCCP
— Limit Comparison of all Monitored Values
— Interrupt Pin for out-of-limit Voltage Indication
„
„
„
5 VID (Voltage Identification) Inputs
XOR Tree Test Mode
24-Pin SSOP Green, Lead-free Package
Power Savings Modes
— Two monitoring modes: continuous or cycling (for power
savings)
— Two low power modes when monitoring if off: Sleep and
Shutdown
ORDER NUMBER(S):
EMC6D103S-CZC FOR 24 PIN, SSOP PACKAGE (LEAD-FREE)
EMC6D103S-CZC-TR FOR 24 PIN, SSOP PACKAGE (LEAD-FREE, TAPE AND REEL)
EVALUATION BOARD IS AVAILABLE
SMSC EMC6D103S
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123
Copyright © 2006 SMSC or its subsidiaries. All rights reserved.
Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for
construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC
reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications
before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent
rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated
version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors
known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not
designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property
damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of
this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered
trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders.
SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE
OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT;
TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD
TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Revision 0.2 (06-14-06)
2
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table of Contents
Chapter 1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 2 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1
EMC6D103S Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 3 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1
3.2
3.3
Pin Functions for EMC6D103S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Buffer Type Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3V Operation, 5V Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 4 Operational Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1
4.2
Maximum Guaranteed Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Ratings for Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chapter 5 SMBus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
Slave Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slave Bus Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bus Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Invalid Protocol Response Behavior. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4.1
Undefined Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Call Address Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slave Device Time-Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stretching the SCLK Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMBus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bus Reset Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMBus Alert Response Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
17
17
18
18
18
18
19
19
19
19
Chapter 6 Hardware Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
Input Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resetting the EMC6D103S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.1
Power-On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.2
Soft Reset (Initialization) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1
Continuous Monitoring Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.2
Cycle Monitoring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.4.1
Diode Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Power Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.6.1
Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.6.2
Shutdown Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog Voltage Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.9.1
Internal Temperature Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.9.2
External Temperature Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.9.3
Temperature Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
21
21
21
21
23
23
24
25
26
27
27
27
27
28
28
28
28
29
30
Chapter 7 Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.1
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SMSC EMC6D103S
3
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
Limit and Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Set-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PWM Fan Speed Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Speed Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Linking Fan Tachometers to PWMs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
31
32
40
46
Chapter 8 Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.1
8.2
Undefined Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Defined Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.1
Registers 20-24h: Voltage Reading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.2
Registers 25-27h: Temperature Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.3
Registers 28-2Fh: Fan Tachometer Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.4
Registers 30-32h: Current PWM Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.5
Register 3Eh: Company ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.6
Register 3Fh: Version / Stepping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.7
Register 40h: Ready/Lock/Start Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.8
Register 41h: Interrupt Status Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.9
Register 42h: Interrupt Status Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.10 Register 43h: VID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.11 Registers 44-4Dh: Voltage Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.12 Registers 4E-53h: Temperature Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.13 Registers 54-5Bh: Fan Tachometer Low Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.14 Registers 5C-5Eh: PWM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.15 Registers 5F-61h: Zone Temperature Range, PWM Frequency . . . . . . . . . . . . . . . . . . .
8.2.16 Register 62h, 63h: PWM Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.17 Registers 64-66h: Minimum PWM Duty Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.18 Registers 67-69h: Zone Low Temperature Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.19 Registers 6A-6Ch: Absolute Temperature Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.20 Register 6F: XOR Test Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.21 Register 7Ch: Special Function Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.22 Register 7Eh: Interrupt Enable 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.23 Register 7Fh: Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.24 Register 80h: Interrupt Enable 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.25 Register 81h: TACH_PWM Association Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.26 Register 82h: Interrupt Enable 3 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.27 Registers 85h-88h: A/D Converter LSbs Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.28 Registers 90h-93h: TachX Option Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.29 Registers 94h-96h: PWMx Option Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
51
51
51
52
53
55
55
55
57
58
59
60
60
61
62
64
66
67
67
68
69
70
71
71
72
73
74
75
75
76
Chapter 9 Timing Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
9.1
9.2
PWM Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
SMBus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Chapter 10 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Appendix A ADC Voltage Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Appendix B Example Fan Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Revision 0.2 (06-14-06)
4
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
List of Figures
Figure 2.1
Figure 5.1
Figure 6.3
Figure 7.1
Figure 7.2
Figure 7.4
Figure 7.6
Figure 7.7
Figure 8.11
Figure 9.1
Figure 9.4
Figure 10.1
Figure B.1
Figure B.2
Figure B.3
Figure B.4
Figure B.5
EMC6D103S 24 Pin SSOP Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Address Selection on EMC6D103S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Interrupt Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Automatic Fan Control Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Automatic Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Spin Up Reduction Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Illustration of PWM Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
PWM and Tachometer Concept. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Fan Activity Above Low Temp Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
PWMx Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
SMBus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
24-Pin SSOP Package Outline, 0.150” Wide Body, 0.025” Pitch. . . . . . . . . . . . . . . . . . . . . . 80
Fan Drive Circuitry (Apply to PWM Driving Two Fans) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Fan Drive Circuitry (Apply to PWM Driving One Fan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Fan Tachometer Circuitry (Apply to Each Fan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Remote Diode (Apply to Remote2 Lines). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Suggested Minimum Track Width and Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
SMSC EMC6D103S
5
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
List of Tables
Table 3.1 Pin Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.2 Buffer Type Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.1 SMBus Slave Address Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.2 SMBus Write Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.3 SMBus Read Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.4 Modified SMBus Receive Byte Protocol Response to ARA. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.1 AVG[2:0] Bit Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.2 Conversion Cycle Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.3 ADC Conversion Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.4 Low Power Mode Control Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.5 Min/Max ADC Conversion Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.6 Temperature Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.1 PWM Ramp Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.2 Minimum RPM Detectable Using 3 Edges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.3 Minimum RPM Detectable Using 2 Edges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.1 Register Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.2 Registers 20-24h: Voltage Reading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.3 Voltage vs. Register Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.4 Registers 25-27h: Temperature Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.5 Temperature vs. Register Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.6 Registers 28-2Fh: Fan Tachometer Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.7 Registers 30-32h: Current PWM Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.8 PWM Duty vs Register Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.9 Register 3Eh: Company ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.10 Register 3Fh: Version / Stepping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.11 Register 40h: Ready/Lock/Start Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.12 Ready/Lock/Start Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.13 Register 41h: Interrupt Status Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.15 Register 42h: Interrupt Status Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.17 Register 43h: VID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.18 Registers 44-4Dh: Voltage Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.20 Registers 4E-53h: Temperature Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.21 Temperature Limits vs. Register Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.22 Registers 54-5Bh: Fan Tachometer Low Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.23 Registers 5C-5Eh: PWM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.24 Fan Zone Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.25 Fan Spin-Up Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.26 Registers 5F-61h: Zone Temperature Range, PWM Frequency . . . . . . . . . . . . . . . . . . . . . . .
Table 8.27 Register Setting vs. PWM Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.28 Register Setting vs. Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.29 Register 62h, 63h: Min/Off, PWM Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.30 PWM Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.31 Registers 64-66h: Minimum PWM Duty Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.32 PWM Duty vs. Register Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.33 Registers 67-69h: Zone Low Temperature Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.34 Temperature Limit vs. Register Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.35 Registers 6A-6Ch: Absolute Temperature Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.36 Absolute Limit vs. Register Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.37 Register 6F: XOR Test Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.38 Register 7Ch: Special Function Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.40 AVG[2:0] Bit Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.41 Register 7Eh: Interrupt Enable 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision 0.2 (06-14-06)
6
DATASHEET
10
11
16
18
18
19
22
22
23
27
28
29
38
44
45
47
51
51
51
52
52
53
54
55
55
55
56
57
58
59
60
60
61
61
62
63
63
64
65
65
66
66
67
67
67
68
68
69
69
70
70
71
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.43 Register 7Fh: Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.45 Register 80h: Interrupt Enable 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.47 Register 81h: TACH_PWM Association Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.50 Register 82h: Interrupt Enable 3 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.52 Registers 85h-88h: A/D Converter LSbs Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8.54 Registers 94h-96h: PWMx Option Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9.1 Timing for PWM[1:3] Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9.2 SMBus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10.1 24-Pin SSOP Package Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A.1 Analog-to-Digital Voltage Conversions for Hardware Monitoring Block. . . . . . . . . . . . . . . . . .
SMSC EMC6D103S
7
DATASHEET
71
72
73
74
75
76
78
79
80
81
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 1 General Description
The EMC6D103S is an environmental monitoring device with automatic fan control capability. This ACPI
compliant device provides hardware monitoring for up to fivevoltages and three thermal zones,
measures the speed of up to four fans, and controls the speed of multiple DC fans using Pulse Width
Modulator (PWM) outputs. High frequency and low frequency PWMs are supported.
The EMC6D103S hardware monitor provides analog inputs for monitoring external voltages of +2.5V,
+5V, +12V and the processor voltage Vccp. This device has the capability to monitor its own internal
VCC power supply, which may be connected to either main power (VCC) or the suspend power well
(VTR). In addition to monitoring the processor voltage, VID inputs are available to identify the voltage
specification. External components are not required for voltage scaling or similar treatment.
The EMC6D103S hardware monitor includes support for monitoring three thermal zones: two external
and one internal. The external temperatures are measured via thermal diode inputs capable of
monitoring remote devices. In addition, the EMC6D103S is equipped with an ambient temperature
sensor for measuring the internal temperature.
Pulse Width Modulators (PWM) control the speed of the fans by varying the output duty cycle of the
PWM. Each PWM can be associated with any or all of the thermal zones monitored. As the
temperature of the associated zone varies, the PWM duty cycle is adjusted accordingly. The Ramp
Rate Control feature controls the rate of change of the PWM output, thereby reducing system noise
created by changing the fan speed. The speed of each fan is monitored by a Fan Tachometer input.
The measured values are compared to values stored in Limit Registers to detect if a fan has stalled
or seized.
Fan speed may be under host software control or automatic. In host control mode, the host software
continuously monitors temperature and fan speed registers, makes decisions as to desired fan speed
and sets the PWM’s to drive the required fan speed. This device offers an interrupt output signal
(INT#), which may be used to interrupt the host on out-of-limit temperature or voltage condition
enabling an ACPI response as opposed to the host software continuously monitoring status. In auto
“zone” mode, the logic continuously monitors the temperature and fan speeds and adjusts speeds
without intervention from the host CPU. Fan speed is adjusted according to an algorithm using the
temperature measured in the selected zone, the high and low limits set by the user, and the current
fan speed.
The EMC6D103S supports two Monitoring modes: Continuous Mode and Cycle Mode. In the continuous
monitoring mode, the sampling and conversion process is performed continuously for each voltage and
temperature reading after monitoring is enabled. The time for each voltage and temperature reading
varies depending on the measurement option. In cycle monitoring mode, the part completes all
sampling and conversions, then waits approximately one second to repeat the process. It repeats the
sampling and conversion process typically every 1.2 seconds (1.4 sec max - default averaging
enabled). The sampling and conversion of each voltage and temperature reading is performed once
every monitoring cycle. (This is a power saving mode.)
The EMC6D103S can be placed in one of two low-power modes: Sleep mode or Shutdown mode. These
modes do not reset any of the registers of the device. In Sleep mode bias currents are on and the
internal oscillator is on, but the A/D converter and monitoring cycle are turned off. Serial bus
communication is still possible with any register in the Hardware Monitor Block while in this low-power
mode. In Shutdown mode the bias currents are off, the internal oscillator is off, and the A/D converter
and monitoring cycle are turned off. Serial communication is only possible with a select register.
Revision 0.2 (06-14-06)
8
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 2 Pinout
2.1
EMC6D103S Pinout
The EMC6D103S is offered in a 24 pin SSOP mechanical package.
SD
A
1
24
PWM1/xTest Out
SCLK
2
23
Vccp
VSS
3
22
2.5V
VCC
4
21
12V
VID0
5
20
5V
VID1
6
19
VID4
VID2
7
18
Remote1+
VID3
8
17
Remote1-
TACH3/INT#
9
16
Remote2+
PWM2/INT#
10
15
Remote2-
TACH1
11
14
TACH4/Address Select
TACH2
12
13
PWM3/Address Enable
EMC6D103
Figure 2.1 EMC6D103S 24 Pin SSOP Pinout
SMSC EMC6D103S
9
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 3 Pin Description
3.1
Pin Functions for EMC6D103S
Table 3.1 Pin Description
PIN #
NAME
BUFFER
REQUIREMENT
BUFFER PER FUNCTION POWER
TYPE
(Note 3.1)
WELL
FUNCTION
NOTES
HARDWARE MONITORING BLOCK (24)
1
SDA
2
SCLK
5
VID0
6
VID1
7
VID2
System Management Bus bi-directional
Data. Open Drain output.
IMOD3
IMOD3
VCC
System Management Bus Clock.
IM
IM
VCC
Voltage ID 0 Input
IM
IM
VCC
Voltage ID 1 Input
IM
IM
VCC
Voltage ID 2 Input
IM
IM
VCC
8
VID3
Voltage ID 3 Input
IM
IM
VCC
19
VID4
Voltage ID 4 Input
IM
IM
VCC
17
Remote1-
This is the negative Analog input (current
sink) from the remote thermal diode. This
serves as the negative input into the A/D.
Digital Input.
IAN
IAN
VCC
18
Remote1+ This is the positive input (current source)
from the remote thermal diode. This serves
as the positive input into the A/D.
IAN
IAN
VCC
15
Remote2-
This is the negative Analog input (current
sink) from the remote thermal diode. This
serves as the negative input into the A/D.
Digital Input.
IAN
IAN
VCC
16
Remote2+ This is the positive input (current source)
from the remote thermal diode. This serves
as the positive input into the A/D.
IAN
IAN
VCC
Analog input for +5V
IAN
IAN
VCC
Note 3.2
20
+5V_IN
22
+2.5V_IN
23
VCCP
21
+12V_IN
Revision 0.2 (06-14-06)
Analog input for +2.5V
IAN
IAN
VCC
Note 3.2
Analog input for +Vccp (processor voltage:
0 to 3.0V).
IAN
IAN
VCC
Note 3.2
Analog input for +12V
IAN
IAN
VCC
Note 3.2
10
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 3.1 Pin Description (continued)
PIN #
NAME
BUFFER
REQUIREMENT
BUFFER PER FUNCTION POWER
TYPE
(Note 3.1)
WELL
FUNCTION
NOTES
HARDWARE MONITORING BLOCK (24)
11
TACH1
Input for monitoring a fan tachometer input.
IM
IM
VCC
12
TACH2
Input for monitoring a fan tachometer input.
IM
IM
VCC
9
TACH3
/INT#
Input for monitoring a fan tachometer input.
/Interrupt output to indicate a thermal
and/or voltage event.
IMOD3
IM /OD3
VCC
14
TACH4
/Address
Select
Input for monitoring a fan tachometer input.
If in Address Select Mode, determines the
SMBus address of the device.
IM
IM
VCC
O8
OD8/O8
VCC
PWM Output 2 controlling speed of fan.
/Interrupt output to indicate a thermal
and/or voltage event.
OD8
OD8/OD8
VCC
PWM Output 3 controlling speed of fan.
If pulled to ground at power on, enables
Address Select Mode (Address Select pin
controls SMBus address of the device).
IOD8
OD8/I
VCC
24
PWM1
PWM Output 1 controlling speed of fan.
/xTest Out When in XOR tree test mode, functions as
XOR Tree output.
10
PWM2
/INT#
13
PWM3
/Address
Enable#
4
VCC
Positive Power Supply. Nominal 3.3V.
VCC is monitored by the Hardware
Monitoring Block.
(Can be powered by +3.3V Standby power
if monitoring in low power states is
required.)
3
VSS
Analog Ground.
Note: The “#” as the suffix of a signal name indicates an “Active Low” signal.
3.2
Note 3.1
Buffer types per function on multiplexed pins are separated by a slash “/” Buffer types in
parenthesis represent multiple buffer types for a single pin function.
Note 3.2
This analog input is backdrive protected.
Buffer Type Description
Note: The buffer type values are specified at VCC=3.3V
Table 3.2 Buffer Type Descriptions
BUFFER TYPE
DESCRIPTION
IM
Digital Input
IAN
Analog Input, Hardware Monitoring Block
IMOD3
Input/Output (Open Drain), 3mA sink.
O8
Output, 8mA sink, 4mA source.
OD8
Output (Open Drain), 8mA sink.
IO8
Input/Output, 8mA sink, 4mA source.
SMSC EMC6D103S
11
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
3.3
3.3V Operation, 5V Tolerance
The EMC6D103S is intended to operate with a nominal 3.3V power supply. The analog voltage pins
are connected to voltage sources at their respective nominal levels. All digital signal pins are 3V
switching, but are tolerant to 5V.
Revision 0.2 (06-14-06)
12
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 4 Operational Description
4.1
Maximum Guaranteed Ratings
Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0oC to +70oC
Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55o to +150oC
Lead Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refer to JEDEC Spec. J-STD-020
Maximum VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0V
Positive Voltage on any pin (except for analog inputs), with respect to Ground . . . . . . . . . . . . . . 5.5V
Negative Voltage on any pin (except for analog inputs), with respect to Ground. . . . . . . . . . . . . . -0.3V
Positive Voltage on voltage analog inputs:
Vccp_in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5V
2.5V_in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0V
+5V_in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0V
12V_in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17V
Note: Stresses above those listed could cause permanent damage to the device. This is a stress
rating only and functional operation of the device at any other condition above those indicated
in the operation sections of this specification is not implied. When powering this device from
laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be
exceeded or device failure can result. Some power supplies exhibit voltage spikes on their
outputs when the AC power is switched on or off. In addition, voltage transients on the AC
power line may appear on the DC output. If this possibility exists, it is suggested that a clamp
circuit be used.
4.2
Ratings for Operation
TA = 0oC - 70oC, VCC=+3.3V±10%
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
COMMENTS
Internal Temperature
Accuracy
-3
-2
±0.25
+3
+2
o
C
oC
0oC <= TA <= 70oC
40oC <= TA <= 70oC
External Diode Sensor
Accuracy
-5
-3
±0.25
+5
+3
oC
o
-40oC <= TS <= 125oC
40oC <= TS <= 100oC
Temperature-to-Digital
Converter Characteristics
SMSC EMC6D103S
13
DATASHEET
C
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
±2
%
Analog-to-Digital Converter
Characteristics
Total Unadjusted Error
Differential Non-Linearity
Power Supply Sensitivity
Total Monitoring Cycle Time
(Cycle Mode, Default
Averaging)
Conversion Time
(Continuous Mode, Default
Averaging)
TUE
COMMENTS
Note 4.1
DNL
±1
LSB
PSS
±1
%/V
tC(Cycle)
1.22
1.4
sec
Note 4.2
223
248
msec
Note 4.3
140
200
kΩ
tC(Cts)
203
Input Resistance
ADC Resolution
10 bits Note 4.6
Input Buffer
(VID0-VID4,TACH1-TACH4)
Low Input Level
VILI
High Input Level
VIHI
2.0
0.8
V
Vcc+0.3
V
0.8
V
Vcc+0.3
V
IOD Type Buffer
(SCL, SDA, PWM1, PWM2,
PWM3/ADDRESS ENABLE,
INT#
Low Input Level
VILI
High Input Level
VIHI
Hysteresis
VHYS
Low Output Level
VOL
2.0
500
mV
0.4
V
Leakage Current
(ALL - Digital)
Input High Current
Input Low Current
Digital Input Capacitance
(Note 4.4)
ILEAKIH
10
µA
VIN = VCC
ILEAKIL
-10
µA
VIN = 0V
CIN
10
pF
VCC Supply Current
Active Mode
ICC
3
mA
Sleep Mode
ICC
500
µA
ICC
3
µA
Shutdown Mode
IOL = +4.0 mA (Note 4.5)
All outputs open, all
inputs transitioning
from/to 0V to/from 3.3V.
Notes:
„
Voltages are measured from the local ground potential, unless otherwise specified.
„
Typical values are at TA=25°C and represent most likely parametric norm.
Revision 0.2 (06-14-06)
14
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
„
Timing specifications are tested at the TTL logic levels, VIL=0.4V for a falling edge and VIH=2.4V
for a rising edge. TRI-STATE output voltage is forced to 1.4V.
Note 4.1
TUE (Total Unadjusted Error) includes Offset, Gain and Linearity errors of the ADC.
Note 4.2
Total Monitoring Cycle Time for cycle mode includes a one second delay plus all
temperature conversions and all analog input voltage conversions.
Note 4.3
See Table 6.2, “Conversion Cycle Timing,” on page 22 for conversion cycle timing for all
averaging options. Only the nominal default case is shown in this section.
Note 4.4
All leakage currents are measured with all pins in high impedance.
Note 4.5
The low output level for PWM pins is actually +8.0mA.
Note 4.6
The h/w monitor analog block implements a 10-bit ADC. The output of this ADC goes to
an averager block, which can be configured to accumulate the averaged value of the
analog inputs. The amount of averaging is programmable. The output of the averaging
block produces a 12-bit temperature or voltage reading value. The 8 MSbits go to the
reading register and the 4 LSbits to the A/D LSb register.
SMSC EMC6D103S
15
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 5 SMBus Interface
The host processor communicates with the Fan Monitoring device through a series of read/write
registers via the SMBus interface. SMBus is a serial communication protocol between a computer host
and its peripheral devices.
5.1
Slave Address
The default Slave Address is 0101110b. If this address is desired, the designer should not ground the
Address Enable# pin and should not apply a strapping resistor to the Address Select pin.
If multiple devices are implemented in a system or another SMBus device requires address 0101110b,
TACH4 and PWM3 must be disabled. In this case, addressing is implemented as follows:
The board designer will apply a 10KΩ pull-down resistor to ground on the Address Enable# pin. Upon
power up, the EMC6D103S device will be placed into Address Enable mode and assign itself an SMBus
address according to the Address Select input. The device will latch the address during the first valid
SMBus transaction in which the first five bits of the targeted address match those of the EMC6D103S
address. This feature eliminates the possibility of a glitch on the SMBus interfering with address
selection.
Table 5.1 SMBus Slave Address Options
ADDRESS
ENABLE#
ADDRESS
SELECT
1
X
BOARD IMPLEMENTATION
Address Enable# pulled to VCC through resistor
Note:
Resistor value will be dependent on PWM
circuit implemented.
SMBUS ADDRESS [7:1]
0101 110b
(default)
0
0
Address Enable# pulled to ground through 10kΩ
resistor
Address Select Pulled to ground through a 10kΩ
resistor
0101 100b
0
1
Address Enable# pulled to ground through 10kΩ
resistor
Address Select pulled to VCC through a 10kΩ
resistor
0101 101b
In this way, there can be up to three EMC6D103S devices on the SMBus at any time. Multiple
EMC6D103S devices can be used to monitor additional processors and temperature zones.
Revision 0.2 (06-14-06)
16
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Address Decided
Start
0
1
0
1
1
SDA
SCL
First five address bits
Figure 5.1 Address Selection on EMC6D103S
5.2
Slave Bus Interface
The EMC6D103S device SMBus implementation is a subset of the SMBus interface to the host. The
device is a slave-only SMBus device. The implementation in the device is a subset of SMBus since it
only supports Write Byte and Read Byte protocols.
The Write Byte and Read Byte protocols are valid SMBus protocols for the device. This part responds
to other protocols as described in the Invalid Protocol Section. Reference the System Management
Bus Specification, Rev 2.0.
The SMBus interface is used to read and write the registers in the device. The register set is shown
in Chapter 8, "Register Set," on page 47.
5.3
Bus Protocols
Typical Write Byte and Read Byte protocols are shown below. Register accesses are performed using
7-bit slave addressing, an 8-bit register address field, and an 8-bit data field. The shading indicates
the Hardware Monitor Block driving data on the SDA line; otherwise, host data is on the SDA line.
The slave address is the unique SMBus Interface Address for the Hardware Monitor Block that
identifies it on SMBus. The register address field is the internal address of the register to be accessed.
The register data field is the data that the host is attempting to write to the register or the contents of
the register that the host is attempting to read.
Note: Data bytes are transferred MSB first.
Byte Protocols
A write byte transfer will always consist of the SMBus Interface Address byte, followed by the Internal
Address Register byte, then the data byte.
The normal read protocol consists of a write to the Hardware Monitor Block with the SMBus Interface
Address byte, followed by the Internal Address Register byte. Then restart the Serial Communication
with a Read consisting of the SMBus Interface Address byte, followed by the data byte read from the
Hardware Monitor Block. This can be accomplished by using the Read Byte protocol.
Write Byte
The Write Byte protocol is used to write data to the registers. The data will only be written if the protocol
shown in Table 5.2 is performed correctly. Only one byte is transferred at time for a Write Byte protocol.
SMSC EMC6D103S
17
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 5.2 SMBus Write Byte Protocol
FIELD
START
SLAVE ADDR
WR
ACK
REG. ADDR
ACK
REG. DATA
ACK
STOP
Bits
1
7
1
1
8
1
8
1
1
Read Byte
The Read Byte protocol is used to read data from the registers. The data will only be read if the
protocol shown in Table 5.3 is performed correctly. Only one byte is transferred at time for a Read Byte
protocol.
Table 5.3 SMBus Read Byte Protocol
FIELD:
Bits:
5.4
START
SLAVE
ADDR
WR
ACK
REG.
ADDR
ACK
START
SLAVE
ADDR
RD
ACK
REG.
DATA
NACK
STOP
1
7
1
1
8
1
1
7
1
1
8
1
1
Invalid Protocol Response Behavior
Registers that are accessed with an invalid protocol will not be updated. A register will only be updated
following a valid protocol. The only valid protocols are the Write Byte and Read Byte protocols, which
are described above.
The EMC6D103S device responds to three SMBus slave addresses:
1. The SMBus slave address that supports the valid protocols defined in the previous sections is
determined by the level on the Address Select and Address Enable pins as shown in Section 5.1,
"Slave Address," on page 16.
2. SMBus Alert Response (0001 100). The SMBus will only respond to the SMBus Alert Response
Address if the SMBus Alert Response interrupt was generated to request a response from the Host.
The SMBus Alert Response is defined in Section 5.10, "SMBus Alert Response Address," on
page 19.
Attempting to communicate with the Hardware Monitor Block over SMBus with an invalid slave
address, or invalid protocol will result in no response, and the SMBus Slave Interface will return to the
idle state.
The only valid registers that are accessible by the SMBus slave address are the registers defined in
the Registers Section. See Section 5.4.1, "Undefined Registers" for response to undefined registers.
5.4.1
Undefined Registers
Reads to undefined registers return 00h. Writes to undefined registers have no effect and return no
error.
5.5
General Call Address Response
The EMC6D103S will not respond to a general call address of 0000_000.
5.6
Slave Device Time-Out
The EMC6D103S supports the slave device timeout as per the SMBus Specification, v2.0.
Revision 0.2 (06-14-06)
18
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
According to SMBus specification, v2.0 devices in a transfer can abort the transfer in progress and
release the bus when any single clock low interval exceeds 25ms (TTIMEOUT, MIN). Devices that have
detected this condition must reset their communication and be able to receive a new START condition
no later than 35ms (TTIMEOUT, MAX).
Note: Some simple devices do not contain a clock low drive circuit; this simple kind of device typically
may reset its communications port after a start or stop condition
5.7
Stretching the SCLK Signal
The EMC6D103S supports stretching of the SCLK by other devices on the SMBus but will not stretch
the SCLK itself.
5.8
SMBus Timing
The SMBus Slave Interface complies with the SMBus AC Timing Specification. See the SMBus timing
diagram shown in the section titled Section 9.2, "SMBus Interface," on page 79.
5.9
Bus Reset Sequence
The SMBus Slave Interface will reset and return to the idle state upon a START field followed
immediately by a STOP field.
5.10
SMBus Alert Response Address
The EMC6D103S device responds to the SMBus Alert Response Address, 0001 100, if the INTEN bit
(register 7Ch bit 2) is set and one or more status events bits are high. The interrupt signal (INT#),
which can be enabled on either the PWM2 or TACH3 pins, can be used as the SMBALERT#. See the
section describing the Interrupt Status Registers on page 24 and the section describing the Interrupt
Pin on page 26 for more details on interrupts.
The device can signal the host that it wants to talk by pulling the SMBALERT# low, if a status bit is
set in one of the interrupt status registers and properly enabled onto the INT# pin. The host processes
the interrupt and simultaneously accesses all SMBALERT# devices through a modified Receive Byte
operation with the Alert Response Address (ARA).
The EMC6D103S device, which pulled SMBALERT# low, will acknowledge the Alert Response Address
and respond with its device address. The 7-bit device address provided by the EMC6D103S device is
placed in the 7 most significant bits of the byte. The eighth bit can be a zero or one.
Table 5.4 Modified SMBus Receive Byte Protocol Response to ARA
FIELD:
START
ALERT
RESPONSE
ADDRESS
Bits:
1
7
RD
ACK
1
1
EMC6D103SSLAVE
ADDRESS
NACK
STOP
8
1
1
After acknowledging the slave address, the EMC6D103S device will disengage the SMBALERT# pulldown by clearing the INT enable bit. If the condition that caused the interrupt remains, the Fan Control
device will reassert the SMBALERT# on the next monitoring cycle, provided the INT enable bit has
been set back to ‘1’ by software.
Note: The INT# signal is an alternate function on the PWM2 and TACH3 pins. The EMC6D103S device
will respond to the SMBus Alert Response address even if the INT# signal is not selected as
the alternate function on one of these pins as long as the following conditions exist: the INTEN
SMSC EMC6D103S
19
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
bit (register 7Ch bit 2) is set, an individual status bit is set in one of the interrupt status
registers, and the corresponding group enable bit is set. Each interrupt event must be enabled
into the interrupt status registers, and the status bits must be enabled onto the INT# signal via
the group enable bits for each type of event (i.e., temperature, voltage and fan). See the
section titled Interrupt Status Registers on page 24.
Revision 0.2 (06-14-06)
20
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 6 Hardware Monitoring
The following sub-sections describe the EMC6D103S Hardware Monitoring features.
6.1
Input Monitoring
The EMC6D103S device’s monitoring function is started by writing a ‘1’ to the START bit in the
Ready/Lock/Start Register (0x40). Measured values from the analog inputs and temperature sensors
are stored in Reading Registers. The values in the reading registers can be accessed via the SMBus
interface. These values are compared to the programmed limits in the Limit Register. The out-of-limit
and diode fault conditions are stored in the Interrupt Status Registers.
6.2
Resetting the EMC6D103S
6.2.1
Power-On Reset
All the registers in the Hardware Monitor Block, except the reading registers, reset to a default value
when power is applied to the block. The default state of the register is shown in the table in the
Register Summary subsection. The default state of Reading Registers are not shown because these
registers have indeterminate power on values.
Note: Usually the first action after power up is to write limits into the Limit Registers.
6.2.2
Soft Reset (Initialization)
Setting bit 7 of the CONF register performs a soft reset. This bit is self-clearing. Soft Reset performs
reset on all the registers except the Reading Registers.
6.3
Monitoring Modes
The Hardware Monitor Block supports two Monitoring modes: Continuous Mode and Cycle Mode.
These modes are selected using bit 1 of the Special Function Register (7Ch). The following
subsections contain a description of these monitoring modes.
The hardware monitor conversion clock is 45KHz ± 10%. Temperature conversions take 96 clocks,
each (2.133ms nom.); voltage conversions take 68 clocks, each (1.511ms nom). The time to complete
a conversion cycle depends upon the number of inputs in the conversion sequence to be measured
(see Table 6.3, “ADC Conversion Sequence,” on page 23) and the amount of averaging per input,
which is selected using the AVG[2:0] bits in the Special Function register (see Register 7Ch: Special
Function Register on page 70).
For each mode, there are four options for the number of measurements that are averaged for each
temperature and voltage reading. These options are selected using bits[7:5] of the Special Function
register (7Ch). These bits are defined as follows:
Bits [7:5] AVG[2:0]
The AVG[2:0] bits determine the amount of averaging for each of the measurements that are performed
by the hardware monitor before the reading registers are updated (Table 6.1). The AVG[2:0] bits are
priority encoded where the most significant bit has highest priority. For example, when the AVG2 bit is
asserted, 32 averages will be performed for each measurement before the reading registers are
updated regardless of the state of the AVG[1:0] bits.
SMSC EMC6D103S
21
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 6.1 AVG[2:0] Bit Decoder
SFTR[7:5]
MEASUREMENTS PER READING
AVG2
AVG1
AVG0
REMOTE
DIODE 1
REMOTE
DIODE 2
INTERNAL
DIODE
ALL VOLTAGE READINGS
(+2.5V, +5V, +12V, VCCP, AND VCC)
0
0
0
128
128
8
8
0
0
1
16
16
1
1
0
1
X
16
16
16
16
1
X
X
32
32
32
32
Note: The default for the AVG[2:0] bits is ‘010’b.
To calculate conversion cycle timing for a given averaging mode:
„
Compute total number of temperature conversions (TEMP_CONV)
„
Compute total number of voltage conversions (VOLT_CONV)
„
Calculate Time to complete all conversions is:
Total Conversion Time = (TEMP_CONV)*96/(45kHz +/-10%)+ (VOLT_CONV)*68/(45kHz +/-10%)
Example: To calculate the nominal conversion time FOR AVG[2:0] = 001b.
Total Conversion Time = (TEMP_CONV)*96/(45kHz)+ (VOLT_CONV)*68/(45kHz)
Total Conversion Time = (16+16+1)*96/(45kHz)+ (5*1)*68/(45kHz)
Total Conversion Time = (33)*2.133ms+ (5)*1.511ms = ~78ms
Table 6.2 illustrates the min., nom., and max. conversion cycle timing for each of the four averaging
modes.
Table 6.2 Conversion Cycle Timing
AVG[2:0]
TOTAL
TEMPERATURE
CONVERSIONS
TOTAL
VOLTAGE
CONVERSIONS
000
(2x128)+(1x8)=264
001
CONVERSION CYCLE TIME (MSEC)
MIN.
NOM.
MAX.
5x8=40
567
624
693
(2x16)+(1x1)=33
5x1=10
71
78
87
01X (default)
3x16=48
5x16=80
203
223
248
1XX
3x32=96
5x32=160
406
447
496
Note 6.1
The hardware monitor conversion clock is 45KHz ± 10%.
Note 6.2
Temperature conversions take 96 clocks, each (2.133ms nom.); Voltage conversions take
68 clocks, each (1.511ms nom).
Revision 0.2 (06-14-06)
22
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
6.3.1
Continuous Monitoring Mode
In the continuous monitoring mode, the sampling and conversion process is performed continuously
for each voltage and temperature reading after the Start bit is set high. The time for each voltage and
temperature reading is shown above for each measurement option.
The continuous monitoring function is started by doing a write to the Ready/Lock/Start Register, setting
the Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order
shown below (see Table 6.3). Sampling of all values occurs in a nominal 223 ms (default - see
Table 6.2, “Conversion Cycle Timing,” on page 22).
Table 6.3 ADC Conversion Sequence
SAMPLING ORDER
REGISTER
1
Remote Diode Temp Reading 1
2
Ambient Temperature reading
3
VCC reading
4
+12V reading
5
+5V reading
6
+2.5V reading
7
Vccp (processor) reading
8
Remote Diode Temp Reading 2
When the continuous monitoring function is started, it cycles through each measurement in sequence,
and it continuously loops through the sequence approximately once every 223 ms (default - see
Table 6.2, “Conversion Cycle Timing,” on page 22). Each measured value is compared to values stored
in the Limit registers. When the measured value violates the programmed limit the Hardware Monitor
Block will set a corresponding status bit in the Interrupt Status Registers.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See Auto
Fan Control Operating Mode on page 33.
The results of the sampling and conversions can be found in the Reading Registers and are available
at any time.
6.3.2
Cycle Monitoring Mode
In cycle monitoring mode, the part completes all sampling and conversions, then waits approximately
one second to repeat the process. It repeats the sampling and conversion process typically every 1.2
seconds (1.4 sec max - default averaging enabled). The sampling and conversion of each voltage and
temperature reading is performed once every monitoring cycle. This is a power saving mode.
The cycle monitoring function is started by doing a write to the Ready/Lock/Start Register, setting the
Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order shown
above.
When the cycle monitoring function is started, it cycles through each measurement in sequence, and
it produces a converted voltage and temperature reading for each input. The state machine waits
approximately one second before repeating this process. Each measured value is compared to values
stored in the Limit registers. When the measured value violates (or is equal to) the programmed limit
the Hardware Monitor Block will set a corresponding status bit in the Interrupt Status Registers.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See the
section titled Auto Fan Control Operating Mode on page 33.
SMSC EMC6D103S
23
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
The results of each sampling and conversion can be found in the Reading Registers and are available
at any time, however, they are only updated once per conversion cycle.
6.4
Interrupt Status Registers
The Hardware Monitor Block contains two interrupt status registers: Register 41h: Interrupt Status
Register 1 on page 57 and Register 42h: Interrupt Status Register 2 on page 58. These registers are
used to reflect the state of all temperature, voltage and fan violation of limit error conditions and diode
fault conditions that the Hardware Monitor Block monitors.
When an error occurs during the conversion cycle, its corresponding bit is set in its respective interrupt
status register. The bit remains set until the register is read by software, at which time the bit will be
cleared to ‘0’ if the associated error event no longer violates the limit conditions or if the diode fault
condition no longer exists. Reading the register will not cause a bit to be cleared if the source of the
status bit remains active.
These registers are read only – a write to these registers have no effect. These registers default to
0x00 on VCC POR and Initialization.
See the description of the Interrupt Status registers in Chapter 8, "Register Set," on page 47.
Each interrupt status bit has a corresponding bit located in an interrupt enable register, which may be
used to enable/disable the individual event from setting the status bit. See the following figure for the
status and enable bits used to control the interrupt bits and INT# pin.
Revision 0.2 (06-14-06)
24
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
INT_STS1 Reg
2.5V_Error
2.5V_Error (INT1[0])
2.5V_Error_En (IER1[2])
Vccp_Error
Vccp_Error (INT1[1])
Diode 1 Limit
Diode 1_En (IER3[2])
Ambient Limit
5V_Error (INT1[3])
Diode 1 Limit (INT1[4])
Ambient Limit (INT1[5])
Ambient_En (IER3[1])
Diode 2 Limit
+
Diode 2 Limit (INT1[6])
Diode 2_En (IER3[3])
INT2 (INT1[7])
INT_STS2 Reg
12V_Error_En (IER1[6])
TACH1 Out-of-Limit
TACH1_En (IER2[1])
TACH2 Out-of-Limit
TACH2 _En (IER2[2])
TACH3 Out-of-Limit
TACH3 _En (IER2[3])
TACH4 Out-of-Limit
12V_Error (INT2[0])
TACH1 (INT2[2])
TACH2 (INT2[3])
TACH3 (INT2[4])
+
TACH4 (INT2[5])
TACH4 _En (IER2[4])
Diode 1 Fault
INT#
TACH_EN
(IER2[0])
12V_Error
+
INT_EN
(SFTR[2])
5V_Error_En (IER1[5])
VCC_Error (INT1[2])
VOLTAGE_EN
(IER1[0])
VCC_Error_En (IER1[7])
5V_Error
+
TEMP_EN
(IER3[0])
Vccp_Error_En (IER1[3])
VCC_Error
Diode 1 Fault (INT2[6])
Diode 1_En (IER3[2])
Diode 2 Fault
Diode 2 Fault (INT2[7])
Diode 2_En (IER3[3])
Figure 6.3 Interrupt Control
Note: The diode fault bits are not mapped directly to the INT# pin. A diode fault condition forces the
diode reading register to a value of 80h, which will generate a Diode Error condition. See
section Diode Fault on page 25.
6.4.1
Diode Fault
The EMC6D103S Chip automatically sets the associated diode fault bit to 1 when any of the following
conditions occur on the Remote Diode pins:
„
The positive and negative terminal are an open circuit.
„
Positive terminal is connected to VCC
„
Positive terminal is connected to ground
„
Negative terminal is connected to VCC
„
Negative terminal is connected to ground
The occurrence of a fault will cause 80h to be loaded into the associated reading register, except for
the case when the negative terminal is connected to ground. A temperature reading of 80h will cause
SMSC EMC6D103S
25
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
the corresponding diode error bit to be set. This will cause the INT# pin to become active if the
individual, group (TEMP), and global enable (INTEN) bits are set.
Notes:
„
The individual remote diode enable bits and the TEMP bit are located inTable 8.51 on page 74. The
INTEN bit is located in bit[2] of Register 7Ch: Special Function Register on page 70.
„
When 80h is loaded into the Remote Diode Reading Register the PWM output(s) controlled by the
zone associated with that diode input will be forced to full on. See Thermal Zones on page 30.
If the diode is disabled, the fault bit in the interrupt status register will not be set. In this case, the
occurrence of a fault will cause 00h to be loaded into the associated reading register. The limits must
be programmed accordingly to prevent unwanted fan speed changes based on this temperature
reading. If the diode is disabled and a fault condition does not exist on the diode pins, then the
associated reading register will contain a “valid” reading.
6.5
Interrupt Pin
The INT# function is used as an interrupt output for out-of-limit temperature, voltage events, and/or fan
errors.
„
The INT# signal can be enabled onto the PWM2 or the TACH3 pins.
To configure the PWM2/INT# pin for the interrupt function, set bit[1] P2INT of the CONF register
(7Fh) to ‘1’
To configure the TACH3/INT# pin for the interrupt function, set bit[0] T3INT of the CONF register
(7Fh) to ‘1’
„
To enable the interrupt pin to go active, set bit 2 of the Special Function Register (7Ch) to ‘1’.
To enable temperature event, voltage events and/or fan events onto the INT# pin:
„
To enable out-of-limit temperature events set bit[0] of the Interrupt Enable 3 (TEMP) register (82h)
to ‘1’.
„
To enable out-of-limit voltage events set bit[0] of the Interrupt Enable 1(VOLT) register (7Eh) to ‘1’
„
To enable Fan tachometer error events set bit[0] of the Interrupt Enable 2(Fan Tachs) register (80h)
to ‘1’.
See Figure 6.3 on page 25. The following description assumes that the interrupt enable bits for all
events are set to enable the interrupt status bits to be set.
If the internal or remote temperature reading violates the low or high temperature limits, INT# will be
forced active low (if all the corresponding enable bits are set: individual enable bits (D1_EN, D2_EN,
and/or AMB_EN), group enable bit (TEMP_EN) and the global enable bit (INTEN)). This pin will remain
low while the Internal Temp Error bit or one or both of the Remote Temp Error bits in Interrupt Status
1 Register is set and the enable bit is set.
The INT# pin will not become active low as a result of the remote diode fault bits becoming set.
However, the occurrence of a fault will cause 80h to be loaded into the associated reading register,
which will cause the corresponding diode error bit to be set. This will cause the INT# pin to become
active if enabled.
The INT# pin can be enabled to indicate out-of-limit voltages. Bit[0] of the Interrupt Enable 1(VOLT)
register (7Eh) is used to enable this option. When this bit is set, if one or more of the voltage readings
violates the low or high limits, INT# will be forced active low (if all the corresponding enable bits are
set: individual enable bits (VCC_Error_En, VCCP_Error_En,12V_Error_En, 5V_Error_En,
33V_Error_En, 25V_Error_En, 18V_Error_En, and/or 15V_Error_En), group enable (VOLT_EN), and
global enable (INT_EN)). This pin will remain low while the associated voltage error bit in the Interrupt
Status Register 1 or Interrupt Status Register 2 is set.
Revision 0.2 (06-14-06)
26
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
The INT# pin can be enabled to indicate fan errors. Bit[0] of the Interrupt Enable 2(Fan Tachs) register
(80h) is used to enable this option. This pin will remain low while the associated fan error bit in the
Interrupt Status Register 2 is set.
The INT# pin will remain low while any bit is set in any of the Interrupt Status Registers. Reading the
interrupt status registers will cause the logic to attempt to clear the status bits; however, the status bits
will not clear if the interrupt stimulus is still active. The interrupt enable bit (Special Function Register
bit[2]) should be cleared by software before reading the interrupt status registers to insure that the INT#
pin will be re-asserted while an interrupt event is active, when the INT_EN bit is written to ‘1’ again.
The INT# pin can also be deasserted by issuing an Alert Response Address Call. See the description
in the section titled SMBus Alert Response Address on page 19.
The INT# pin may only become active while the monitor block is operational.
6.6
Low Power Modes
The Hardware Monitor Block can be placed in a low-power mode by writing a ‘0’ to Bit[0] of the
Ready/Lock/Start Register (0x40). The low power mode that is entered is either sleep mode or
shutdown mode as selected using Bit[0] of the Special Function Register (7Ch). These modes do not
reset any of the registers of the Hardware Monitor Block. In both of these modes, the PWM pins are
at 100% duty cycle.
Table 6.4 Low Power Mode Control Bits
START
LPMD
DESCRIPTION
0
0
Sleep Mode
0
1
Shutdown Mode
1
x
Monitoring
Notes:
6.6.1
„
START and LPMD bits cannot be modified when the LOCK bit is set.
„
START bit is located in the Ready/Lock/Start register (40h). LPMD bit is located in the Special
Function Register (7Ch)
Sleep Mode
This is a low power mode in which bias currents are on and the internal oscillator is on, but the A/D
converter and monitoring cycle are turned off. Serial bus communication is still possible with any
register in the Hardware Monitor Block while in this low-power mode.
6.6.2
Shutdown Mode
This is a low power mode in which bias currents are off, the internal oscillator is off, and the the A/D
converter and monitoring cycle are turned off. Serial communication is only possible with Bits[2:0] of
the Special Function Register at 7Ch and Bits [7:0] of the Configuration Register at 7Fh, which become
write-only registers in this mode.
6.7
Analog Voltage Measurement
The Hardware Monitor Block contains inputs for directly monitoring the power supplies (+12 V, +5 V,
+2.5V, Vccp, and VCC). These inputs are scaled internally to an internal reference source, converted
via an 8 bit successive approximation register ADC , and scaled such that the correct value refers to
3/4 scale or 192 decimal. The VCCP input is scaled for a full range of 0V to 3V.
This removes the need for external resistor dividers and allows for a more accurate means of
measurement since the voltages are referenced to a known value. Since any of these inputs can be
SMSC EMC6D103S
27
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
above VCC or below Ground, they are not diode protected to the power rails. The measured values
are stored in the Reading registers and compared with the Limit registers. The status bits in the
Interrupt Status Register 1 and 2 are set if the measured values violate the programmed limits.
The Vccp voltage input measures the processor voltage, which will lie in the range of 0V to 3.0V.
Table 6.5, "Min/Max ADC Conversion Table" shows the values of the analog inputs that correspond to
the min and max output codes of the A/D converter. For a complete list of the ADC conversions see
Appendix A, "ADC Voltage Conversion," on page 81.
Table 6.5 Min/Max ADC Conversion Table
INPUT VOLTAGE
+12VIN
+5VIN
VCC/3.3VIN
+2.5VIN
+1.8VIN
+1.5VIN
+VCCP
Min Value (Corresponds
to A/D output 00000000)
<0.062
<0.026
<0.017
<0.013
<0.009
<0.008
<0.012
Max Value (Corresponds
to A/D output 11111111)
>15.938
>6.640
>4.383
>3.320
>2.391
>1.992
>2.988
6.8
Voltage ID
VID0-VID4 digital inputs are used to store processor Voltage ID codes (for processor operating voltage)
in the VID0-4 register (43h). These VIDs can be read out by the management system using the SMBus
interface.
6.9
Temperature Measurement
Temperatures are measured internally by bandgap temperature sensor and externally using two sets
of diode sensor pins (for measuring two external temperatures). See subsections below.
Note: The temperature sensing circuitry for the two remote diode sensors is calibrated for a 3904
type diode.
6.9.1
Internal Temperature Measurement
Internal temperature can be measured by bandgap temperature sensor. The measurement is
converted into digital format by internal ADC. This data is converted in two’s complement format since
both negative and positive temperature can be measured. This value is stored in Internal Temperature
Reading register (26h) and compared to the Temperature Limit registers (50h – 51h). If this value
violates the programmed limits in the Internal High Temperature Limit register (51h) or the Internal Low
Temperature Limit register (50h) the corresponding status bit in Interrupt Status Register 1 is set.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See the
section titled Auto Fan Control Operating Mode on page 33.
6.9.2
External Temperature Measurement
The Hardware Monitor Block also provides a way to measure two external temperatures using diode
sensor pins (Remote x+ and Remote x-). The value is stored in the register (25h) for Remote1+ and
Remote1- pins. The value is stored in the Remote Temperature Reading register (27h) for Remote2+
and Remote2- pins. If these values violate the programmed limits in the associated limit registers, then
the corresponding Remote Diode 1 (D1) or Remote Diode 2 (D2) status bits will be set in the Interrupt
Status Register 1.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See Auto
Fan Control Operating Mode on page 33.
Revision 0.2 (06-14-06)
28
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
There are Remote Diode (1 or 2) Fault status bits in Interrupt Status Register 2 (42h), which, when set
to a logical ‘1’, indicate a short or open-circuit on remote thermal diode inputs (Remote x+ and Remote
x-). Before a remote diode conversion is updated, the status of the remote diode is checked. In the
case of a short or open-circuit on the remote thermal diode inputs, the value in the corresponding
reading register will be forced to 80h. Note that this will cause the associated remote diode limit
exceeded status bit to be set (i.e. Remote Diode x Limit Error bits (D1 and D2) are located in the
Interrupt Status 1 Register at register address 41h).
The temperature change is computed by measuring the change in Vbe at two different operating points
of the diode to which the Remote x+ and Remote x- pins are connected. But accuracy of the
measurement also depends on non-ideality factor of the process the diode is manufactured on.
6.9.3
Temperature Data Format
Temperature data can be read from the three temperature registers:
„
Internal Temp Reading register (26h)
„
Remote Diode 1 Temp Reading register (25h)
„
Remote Diode 2 Temp Reading register (27h)
Table 6.6, "Temperature Data Format" shows several examples of the format of the temperature digital
data, represented by an 8-bit, two’s complement word with an LSB equal to 1.0 0C.
Table 6.6 Temperature Data Format
-1270C
-127
81h
1000 0001
-25
E7h
…
1100 1110
1110 0111
…
…
…
CEh
…
…
-25 0C
-50
…
…
-50 0C
…
DIGITAL OUTPUT
…
READING (HEX)
…
READING (DEC)
…
TEMPERATURE
0 0C
0
00h
0000 0000
+1 0C
1
01h
0000 0001
50
32h
…
0001 1001
0011 0010
…
…
…
19h
…
…
+500C
25
…
…
+25 0C
…
1111 1111
…
FFh
…
-1
…
-1 0C
+1270C
127
7Fh
0111 1111
SENSOR ERROR
128
80h
1000 0000
SMSC EMC6D103S
29
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
6.10
Thermal Zones
Each temperature measurement input is assigned to a Thermal Zone to control the PWM outputs in
Auto Fan Control mode. These zone assignments are as follows:
„
Zone 1 = Remote Diode 1 (Processor)
„
Zone 2 = Ambient (Internal) Temperature Sensor
„
Zone 3 = Remote Diode 2
Revision 0.2 (06-14-06)
30
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 7 Fan Control
The following sections describe the various fan control and monitoring modes in the part.
7.1
General Description
This Fan Control device is capable of driving multiple DC fans via three PWM outputs and monitoring
up to four fans equipped with tachometer outputs in either Manual Fan Control mode or in Auto Fan
Control mode. The three fan control outputs (PWMx pins) are controlled by a Pulse Width Modulation
(PWM) scheme. The four pins dedicated to monitoring the operation of each fan are the TACH[1:4]
pins. Fans equipped with Fan Tachometer outputs may be connected to these pins to monitor the
speed of the fan.
7.1.1
Limit and Configuration Registers
At power up, all the registers are reset to their default values and PWM[1:3] are set to “Fan always on
Full” mode. Before initiating the monitoring cycle for either manual or auto mode, the values in the limit
and configuration registers should be set.
The limit and configuration registers are:
„
Registers 54h – 5Bh: TACHx Minimum
„
Registers 5Fh – 61h: Zone x Range/FANx Frequency
„
Registers 5Ch – 5Eh: PWMx Configuration
„
Registers 62h − 63h: PWM x Ramp Rate Control
„
Registers 64h – 66h: PWMx Minimum Duty Cycle
„
Registers 67h – 69h: Zone x Low Temp LIMIT
„
Registers 6Ah – 6Ch: Zone x Temp Absolute Limit – all fans in Auto Mode are set to full
„
Register 81h: TACH_PWM Association
„
Registers 90h – 93h: Tachx Option Registers
„
Registers 94h – 96h: PWMx Option Registers
The limit and configuration registers are defined in Chapter 8, Register Set.
Notes:
7.1.2
„
The START bit in Register 40h Ready/Lock/Start Register must be set to ‘1’ to start temperature
monitoring functions.
„
Setting the PWM Configuration register to Auto Mode will not take effect until after the START bit
is set
Device Set-Up
BIOS will follow the steps listed below to configure the fan registers on this device. The registers
corresponding to each function are listed. All steps may not be necessary if default values are
acceptable. Regardless of all changes made by the BIOS to the limit and parameter registers during
configuration, the EMC6D103S will continue to operate based on default values until the Start bit, in the
Ready/Lock/Start register, is set. Once the Start bit is set, the EMC6D103S will operate according to the
values that were set by BIOS in the limit and parameter registers.
1. Set limits and parameters (not necessarily in this order)
2. [5F-61h] Set PWM frequencies and Auto Fan Control Range.
3. [62-63h] Set Ramp Rate Control
SMSC EMC6D103S
31
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
4. [5C-5Eh] Set the fan spin-up delays.
5. [5C-5Eh] Match each PWM output with a corresponding thermal zone.
6. [67-69h] Set the zone temperature low limits.
7. [6A-6Ch] Set the zone temperature absolute limits.
8. [64-66h] Set the PWM minimum duty cycle.
9. [81h] Associate a Tachometer input to a PWM output Register
10. [90-93h] Select the TACH Mode of operation (Mode 1 or Mode 2)
11. [90-93h] Set the number of edges per tach reading
12. [90-93h] Set the ignore first 3 edges of tach input bit
13. [90-93h] Set the SLOW bit to 0b if tach reading should indicated slow fan event as FFFEh and 1b
if stalled fan event as FFFFh.
14. [94-96h] Set the TACH Reading Update rate
15. [94-96h] Set the tach reading guard time (Mode 2 Only)
16. [94-96h] Set the TACH reading logic for Opportunistic Mode (Mode 2 Only)
17. [94-96h] Set the SZEN bit, which determines if the PWM output will ramp to Off or jump to Off.
18. [40h] Set bit 0 (Start) to start monitoring.
19. [40h] Set bit 1 (Lock) to lock the limit and parameter registers (optional)
7.1.3
PWM Fan Speed Control
Note: The following description applies to PWM1, PWM2, and PWM3.
When describing the operation of the PWMs, the terms “Full on” and “100% duty cycle” means that
the PWM output will be high for 255 clocks and low for 1 clock (INVERT bit = 0). The exception to this
is during fan spin-up when the PWM pin will be forced high for the duration of the spin-up time.
7.1.3.1
Manual Fan Control Operating Mode (Test Mode)
When operating in Manual Fan Control Operating Mode, software controls the speed of the fans by
directly programming the PWM duty cycle. The operation of the fans can be monitored based on
reading the temperature and tachometer reading registers and/or by polling the interrupt status
registers. The EMC6D103S offers the option of generating an interrupt indicated by the INT# signal
located on the PWM2 and TACH3 pins.
To control the PWM outputs in manual mode:
„
Write ‘111’ to bits[7:5] Zone/Mode, located in Registers 5Ch-5Eh: PWMx Configuration.
„
The speed of the fan is controlled by the duty cycle set for that PWM output. The duty cycle must
be programmed in Registers 30h-32h: Current PWM Duty
To monitor the fans:
Fans equipped with Tachometer outputs can be monitored via the TACHx input pins. See Section 7.1.4,
"Fan Speed Monitoring," on page 40.
If an out-of-limit condition occurs, the corresponding status bit will be set in the Interrupt Status
registers. Setting this status bit will generate an interrupt signal on the INT# pin (if enabled). Software
must handle the interrupt condition and modify the operation of the device accordingly. Software can
evaluate the operation of the Fan Control device through the Temperature and Fan Tachometer
Reading registers.
When in manual mode, the current PWM duty cycle registers can be written to adjust the speed of the
fans, when the start bit is set. These registers are not writable when the lock bit is set.
Revision 0.2 (06-14-06)
32
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Note: The PWMx Current Duty Cycle register is implemented as two separate registers: a read-only
and a write-only. When a value is written to this register in manual mode there will be a delay
before the programmed value can be read back by software. The hardware updates the readonly PWMx Current Duty Cycle register on the beginning of a PWM cycle. If Ramp Rate
Control is disabled, the delay to read back the programmed value will be from 0 seconds to
1/(PWM frequency) seconds. Typically, the delay will be 1/(2*PWM frequency) seconds.
7.1.3.2
Auto Fan Control Operating Mode
The EMC6D103S implements automatic fan control. In Auto Fan Mode, this device automatically adjusts
the PWM duty cycle of the PWM outputs, according to the flow chart on the following page (see
Figure 7.1 Automatic Fan Control Flow Diagram on page 34).
PWM outputs are assigned to a thermal zone based on the PWMx Configuration registers (see Section
6.10, "Thermal Zones," on page 30). It is possible to have more than one PWM output assigned to a
thermal zone. For example, PWM outputs 2 and 3, connected to two chassis fans, may both be
controlled by thermal zone 2. At any time, if the temperature of a zone exceeds its absolute limit, all
PWM outputs go to 100% duty cycle to provide maximum cooling to the system (except those fans
that are disabled or in manual mode).
It is possible to have a single fan controlled by multiple zones, turning on when either zone requires
cooling based on its individual settings.
A VCC POR resets all values to their initial or default states.
If the start bit is one, the Auto Fan Control block will evaluate the temperature in the zones configured
for each Fan in a round robin method. The Auto Fan Control block completely evaluates the zones for
all three fans in a maximum of 0.25sec.
SMSC EMC6D103S
33
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
AutoFanMode
Initiated
EndPollingCycle
No
EndFanSpinUp
SpinUp
TimeElapsed?
(5C-5E)
BeginPolling
Cycle
Yes
FanSpinningUp?
Yes
No
Overrideall PWM
outputs to100%
dutycycleexceptif
disabledorin
manual mode
Temp>=
AbsLimit
(6A~6C)
Yes
No
T emp>=Low
Limit
(67~69)
SetFanOutputto
No
100%
Yes
BeginFanSpin-Up
MinPWM
at0%?
Yes
Setfantomin
PWM
(64~66)
No
Setfanspeedbasedon
AutoFanRange
Algorithm*
Figure 7.1 Automatic Fan Control Flow Diagram
*See Registers 5C-5Eh: PWM Configuration on page 62 for details.
When in Auto Fan Control Operating Mode the hardware controls the fans directly based on monitoring
of temperature and speed.
To control the fans:
Set the minimum temperature that will activate the Automatic Fan control algorithm. This value is
programmed in Registers 67h-69h: Zone x Low Temp Limit (Auto Fan Mode Only).
The speed of the fan is controlled by the duty cycle set for that device. The duty cycle for the minimum
fan speed must be programmed in Registers 64h-66h: PWMx Minimum Duty Cycle. This value
corresponds to the speed of the fan when the temperature reading is equal to the minimum
temperature LIMIT setting. As the actual temperature increases and is above the Zone LIMIT
temperature and below the Absolute Temperature Limit, the PWM will be determined by a linear
function based on the Auto Fan Speed Range bits in Registers 5Fh-61h.
Revision 0.2 (06-14-06)
34
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Set the absolute temperature for each zone in Registers 6Ah-6Ch: Zone x Temp Absolute Limit (Auto
Fan Mode only). If the actual temperature is equal to or exceeds the absolute temperature in one or
more of the associated zones, all Fans operating in auto mode will be set to Full on, regardless of
which zone they are operating in (except those that are disabled or configured for Manual Mode).
Note: Fans can be disabled via the PWMx Configuration registers and the absolute temperature
safety feature can be disabled by writing 80h into the Zone x Temp Absolute Limit registers.
To set the mode to operate in auto mode, set Bits[7:5] Zone/Mode, located in Registers 5Ch-5Eh: PWM
Configuration Bits[7:5]=’000’ for PWM on Zone 1; Bits[7:5]=’001’ for PWM on Zone 2; Bits[7:5]=’010’
for PWM on Zone 3. If the “Hottest” option is chosen (101 or 110), then the PWM output is controlled
by the zone that results in the highest PWM duty cycle value.
Notes:
„
Software can be alerted of an out-of-limit condition by the INT# pin if a status bit is set and enabled
and the interrupt function is enabled on either the PWM2 or TACH3 pins
„
Software can monitor the operation of the Fans through the Fan Tachometer Reading registers and
by the PWM x Current PWM duty registers. It can also monitor current temperature readings
through the Temperature Limit Registers if hardware monitoring is enabled.
„
Fan control in auto mode is implemented without any input from external processor.
In auto “Zone” mode, the speed is adjusted automatically as shown in the following figure. Fans are
assigned to a zone(s). It is possible to have more than one fan assigned to a thermal zone or to have
multiple zones assigned to one fan.
Figure 7.2 on page 36 shows the control for the auto fan algorithm. The part allows a minimum
temperature to be set, below which the fan will run at minimum speed. A temperature range is specified
over which the part will automatically adjust the fan speed. If the minimum fan speed is set to 00h,
then, when the temperature exceeds the low limit, the fan will “spin up” by going on full for a
programmable amount of time. Following this spin up time, the fan will go to a duty cycle computed
by the auto fan algorithm. As the temperature rises, the duty cycle will increase until the fan is running
at full-speed when the temperature reaches the minimum plus the range value. The effect of this is a
temperature feedback loop, which will cause the temperature to reach equilibrium between the
minimum temperature and the minimum temperature plus the range. Provided that the fan has
adequate cooling capacity for all environmental and power dissipation conditions, this system will
maintain the temperature within acceptable limits, while allowing the fan to run slower (and quieter)
when less cooling is required.
SMSC EMC6D103S
35
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
PWM Min set to 0%
Temp
Temp
TMAX = TMIN +
TRANGE
PWM Min set to x%
(x is not 0)
TMAX = TMIN +
TRANGE
TMIN
TMIN
Duty
Cycle
Duty
Cycle
100%
100%
Min
spin-up
time
Note: When spin-up ends, the PWM is set to the
current calculated PWM
Figure 7.2 Automatic Fan Control
7.1.3.3
Spin Up
When a fan is being started from a stationary state (PWM duty cycle =00h), the part will cause the fan
to “spin up” by going to 100% duty cycle for a programmable amount of time to overcome the inertia
of the fan (i.e., to get the fan turning). Following this spin up time, the fan will go to the duty cycle
computed by the auto fan algorithm.
Note 7.3
The EMC6D103S automatically performs the Spin Up routine upon power-up. The only
conditions that will allow the fan to be in an stationary state are if the user programs the
PWM input to 00h (in Manual Mode) or the user programs the Minimum PWM to 00h and
the corresponding temperature channel(s) are below the low temperature limit.
During spin-up, the PWM duty cycle is reported as 0%.
To limit the spin-up time and thereby reduce fan noise, the part uses feedback from the tachometers
to determine when each fan has started spinning properly. The following tachometer feedback is
included into the auto fan algorithm during spin-up.
Auto Fan operation during Spin Up:
The PWM goes to 100% duty cycle until the tachometer reading register is below the minimum limit
(see Figure 7.4), or the spin-up time expires, whichever comes first. This causes spin-up to continue
until the tachometer enters the valid count range, unless the spin up time expires. If the spin up expires
before the tachometer enters the valid range, an interrupt status bit will be set once spin-up expires.
Note that more than one tachometer may be associated with a PWM, in which case all tachometers
associated with a PWM must be in the valid range for spin-up to end.
Revision 0.2 (06-14-06)
36
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
PWM Output
tach reading
vs. tach limit
duty cycle = 0%
FFFFh
duty cycle = 100%
tach reading >
tach limit
tach reading < tach limit
Spin Up Time
Programmed Spin Up Time
Note: When Spin Up Reduction is enabled (SUREN), the Spin Up time will be less than
or equal to the programmed time for Spin Up. Once the tachometer(s) associated with a
PWM output are operating within the programmed limits or the Spin Up time expires,
whichever comes first, the PWM output is reduced to the calculated duty cycle.
Figure 7.4 Spin Up Reduction Enabled
This feature defaults to enabled; it can be disabled by clearing bit 4 of the Configuration register (7Fh).
If disabled, the all fans go to 100% duty cycle for the duration of their associated spin up time. Note
that the Tachometer x minimum registers must be programmed to a value less than FFFFh in order
for the spin up reduction to work properly.
Notes:
7.1.3.4
„
The tachometer reading register always gives the actual reading of the tachometer input.
„
No interrupt bits are set during spin-up.
Hottest Option
If the “Hottest” option is chosen (101 or 110), then the fan is controlled by the limits and parameters
associated with the zone that requires the highest PWM duty cycle value, as calculated by the auto
fan algorithm.
7.1.3.5
Ramp Rate Control Logic
The Ramp Rate Control Logic, if enabled, limits the amount of change in the PWM duty cycle over a
specified period of time. This period of time is programmable in the Ramp Rate Control registers
located at offsets 62h and 63h.
7.1.3.5.1
RAMP RATE CONTROL DISABLED: (DEFAULT)
The Auto Fan Control logic determines the duty cycle for a particular temperature. If PWM Ramp Rate
Control is disabled, the PWM output will be set to this calculated duty cycle.
7.1.3.5.2
RAMP RATE CONTROL ENABLED:
If PWM Ramp Rate Control is enabled, the PWM duty cycle will Ramp up or down to the new duty
cycle computed by the auto fan control logic at the programmed Ramp Rate. The PWM Ramp Rate
Control logic compares the current duty cycle computed by the auto fan logic with the previous ramp
rate duty cycle. If the current duty cycle is greater than the previous ramp rate duty cycle the ramp
rate duty cycle is incremented by ‘1’ at the programmed ramp rate until it is greater than or equal to
the current calculated duty cycle. If the current duty cycle is less than the previous ramp rate duty
cycle, the ramp rate duty cycle is decremented by ‘1’ until it is less than or equal to the current duty
cycle. If the current PWM duty cycle is equal to the calculated duty cycle the PWM output will remain
unchanged.
SMSC EMC6D103S
37
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Internally, the PWM Ramp Rate Control Logic will increment/decrement the internal PWM Duty cycle
by ‘1’ at a rate determined by the Ramp Rate Control Register (see Register 62h, 63h: PWM Ramp
Rate Control on page 66). The actual duty cycle output is changed once per the period of the PWM
output, which is determined by the frequency of the PWM output. (See Figure 7.6 Illustration of PWM
Ramp Rate Control on page 39.)
„
If the period of the PWM output is less than the step size created by the PWM Ramp Rate, the
PWM output will hold the duty cycle constant until the Ramp Rate logic increments/decrements the
duty cycle by ‘1’ again. For example, if the PWM frequency is 87.7Hz (1/87.7Hz = 11.4msec) and
the PWM Step time is 206msec, the PWM duty cycle will be held constant for a minimum of 18
periods (206/11.4 = 18.07) until the Ramp Logic increments/decrements the actual PWM duty cycle
by ‘1’.
„
If the period of the PWM output is greater than the step size created by the PWM Ramp Rate, the
ramp rate logic will force the PWM output to increment/decrement the actual duty cycle in
increments larger than 1/255. For example, if the PWM frequency is 11Hz (1/11Hz = 90.9msec)
and the PWM Step time is 5msec, the PWM duty cycle output will be incremented 18 or 19 out of
255 (i.e., 90.9/5 = 18.18) until it reaches the calculated duty cycle.
Notes:
„
The step size may be less if the calculated duty cycle minus the actual duty cycle is less than 18.
„
The calculated PWM Duty cycle reacts immediately to a change in the temperature reading value.
The temperature reading value may be updated once in 624msec, once in 78msec, once in
223msec (default), or once in 447msec (see Table 6.2, “Conversion Cycle Timing,” on page 22).
The internal PWM duty cycle generated by the Ramp Rate control logic gradually ramps up/down
to the calculated duty cycle at a rate pre-determined by the value programmed in the PWM Ramp
Rate Control bits . The PWM output latches the internal duty cycle generated by the Ramp Rate
Control Block every 1/(PWM frequency) seconds to determine the actual duty cycle of the PWM
output pin.
PWM Output Transition from OFF to ON
When the calculated PWM Duty cycle generated by the auto fan control logic transitions from the ‘OFF’
state to the ‘ON’ state (i.e., Current PWM duty cycle>00h), the internal PWM duty cycle in the Ramp
Rate Control Logic is initialized to the calculated duty cycle without any ramp time and the PWMx
Current Duty Cycle register is set to this value.The PWM output will latch the current duty cycle value
in the Ramp Rate Control block to control the PWM output.
Note 7.5
This event will only occur if the MInimum PWM for a particular PWM driver is programmed
to be 00h and is either changed (if the PWM driver is configured for Manual Operating
Mode) or the temperature rises above the low limit (if the PWM driver is configured for
Automatic Operating Mode).
PWM Output Transition from ON to OFF
Each PWM output has a control bit to determine if the PWM output will transition immediately to the
OFF state (default) or if it will gradually step down to Off at the programmed Ramp Rate. These control
bits (SZEN) are located in the PWMx Options registers at offsets 94h-96h.
This transition will only occur in Manual Mode if the user sets the PWM duty cycle to 0% from a nonzero value.
Table 7.1 PWM Ramp Rate
TIME PER
PWM STEP
RRX-[2:0]
PWM RAMP TIME (SEC)
(TIME FROM 33%
DUTY CYCLE TO
100% DUTY CYCLE)
PWM RAMP TIME (SEC)
(TIME FROM MIN DUTY
CYCLE TO 100% DUTY
CYCLE)
(PWM STEP SIZE =
1/255)
PWM
RAMP
RATE
(HZ)
000
35
52.53
206 msec
4.85
Revision 0.2 (06-14-06)
38
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 7.1 PWM Ramp Rate (continued)
TIME PER
PWM STEP
RRX-[2:0]
PWM RAMP TIME (SEC)
(TIME FROM 33%
DUTY CYCLE TO
100% DUTY CYCLE)
PWM RAMP TIME (SEC)
(TIME FROM MIN DUTY
CYCLE TO 100% DUTY
CYCLE)
(PWM STEP SIZE =
1/255)
PWM
RAMP
RATE
(HZ)
001
17.6
26.52
104 msec
9.62
010
11.8
17.595
69 msec
14.49
011
7.0
10.455
41 msec
24.39
100
4.4
6.63
26 msec
38.46
101
3.0
4.59
18 msec
55.56
110
1.6
2.55
10 msec
100
111
0.8
1.275
5 msec
200
Example 1: PWM period < Ramp Rate Step Size
PWM frequency = 87.7Hz (11.4msec) & PWM Ramp Rate = 38.46Hz (26msec)
Calculate Duty Cycle
70h
Ramping Duty Cycle
70h
74h
72h
71h
26ms
PWM Duty Cycle
70h
26ms
73h
74h
26ms
26ms
71h
71h
71h
72h
72h
73h
73h
73h
74h
74h
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
11.4ms
74h
Example 2: PWM period > Ramp Rate Step Size
PWM frequency = 11Hz (90.9msec) & PWM Ramp Rate = 38.46Hz (26msec)
Calculate Duty Cycle
70h
Ramping Duty Cycle
70h
74h
72h
71h
26ms
PWM Duty Cycle
26ms
70h
73h
74h
26ms
26ms
71h
74h
90.9msec
Figure 7.6 Illustration of PWM Ramp Rate Control
Notes:
„
The PWM Duty Cycle latches the Ramping Duty Cycle on the rising edge of the PWM output.
„
The calculated duty cycle, ramping duty cycle, and the PWM output duty cycle are asynchronous
to each other, but are all synchronized to the internal 90kHz clock source.
SMSC EMC6D103S
39
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
It should be noted that the actual duty cycle on the pin is created by the PWM Ramp Rate Control
block and latched on the rising edge of the PWM output. Therefore, the current PWM duty cycle may
lag the PWM Calculated Duty Cycle.
7.1.4
Fan Speed Monitoring
The chip monitors the speed of the fans by utilizing fan tachometer input signals from fans equipped
with tachometer outputs. The fan tachometer inputs are monitored by using the Fan Tachometer
registers. These signals, as well as the Fan Tachometer registers, are described below.
The tachometers will operate in one of two modes:
7.1.4.1
„
Mode 1: Standard tachometer reading mode. This mode is used when the fan is always powered.
„
Mode 2: Enhanced tachometer reading mode. This mode is used when the PWM is pulsing the fan.
TACH Inputs
The tachometer inputs are implemented as digital input buffers with logic to filter out small glitches on
the tach signal.
7.1.4.2
Selecting the Mode of Operation:
The mode is selected through the Mode Select bits located in the Tach Option register. This Mode
Select bit is defined as follows:
„
0=Mode 1: Standard tachometer reading mode
„
1=Mode 2 (default): Enhanced tachometer reading mode.
Default Mode of Operation:
7.1.4.3
„
Mode 2
„
Slow interrupt disabled (Force FFFEh)
„
Tach interrupt enabled via enable bit
„
Tach Limit = FFFFh
„
Look for 5 tach edges
„
Don’t ignore first 3 edges after guard time
„
Guard Time = 32 clock periods (1 clock period = 1/90kHz).
„
Tach readings updated once a second
Mode 1 – Always Monitoring
Mode 1 is the simple case. In this mode, the fan is always powered when it is ‘ON’ and the fan
tachometer output ALWAYS has a valid output. This mode is typically used if a linear DC Voltage
control circuit drives the fan. In this mode, the fan tachometer simply counts the number of 90kHz
pulses between the programmed number of edges (default = 5 edges). The fan tachometer reading
registers are continuously updated.
Notes:
„
Some enhanced features added to support Mode 2, are available to Mode 1 also. They are:
programmable number of tach edges and force tach reading register to FFFEh to indicate a SLOW
fan.
„
Five edges or two tach pulses are generated per revolution.
The counter is used to determine the period of the Fan Tachometer input pulse. The counter starts
counting on the first edge and continues counting until it detects the last edge or until it reaches FFFFh.
If the programmed number of edges is detected on or before the counter reaches FFFFh, the reading
register is updated with that count value. If the counter reaches FFFFh and no edges were detected
Revision 0.2 (06-14-06)
40
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
a stalled fan event has occurred and the Tach Reading register will be set to FFFFh. If one or more
edges are detected, but less than the programmed number of edges, a slow fan event has occurred
and the Tach Reading register will be set to either FFFEh or FFFFh depending on the state of the Slow
Tach bits located in the TACHx Options registers at offsets 90h - 93h. Software can easily compute
the RPM value using the tachometer reading value if it knows the number of edges per revolution.
7.1.4.4
Mode 2 – Monitor Tach input When PWM is ‘ON’
In this mode, the PWM is used to pulse the Fan motor of a 3-wire fan. 3-wire fans use the same power
supply to drive the fan motor and to drive the tachometer output logic. When the PWM is ‘ON’ the fan
generates valid tach pulses. When the PWM is not driving the Fan, the tachometer signal is not
generated and the tach signal becomes indeterminate or tristate. Therefore, Mode 2 only makes
tachometer measurements when the associated PWM is driving high during an update cycle. As a
result, the Fan tachometer measurement is “synchronized” to the PWM output, such that it only looks
for tach pulses when the PWM is ‘ON’.
Notes:
7.1.4.4.1
„
High frequency PWM operation is designed for use with four wire fans. Although some three wire
fans are capable of operating with high frequency PWM, the tach output is very difficult to read.
External circuitry is required for accurate tach reading of a three wire fan that is driven with high
frequency PWM.
„
Any fan tachometer input may be associated with any PWM output (see Linking Fan Tachometers
to PWMs on page 46.)
ASSUMPTIONS (REFER TO FIGURE 7.7, "PWM AND TACHOMETER CONCEPT"):
The Tachometer pulse generates 5 transitions per fan revolution (i.e., two fan tachometer periods per
revolution, edges 2→6). One half of a revolution (one tachometer period) is equivalent to three edges
(2→4 or 3→5). One quarter of a revolution (one-half tachometer period) is equivalent to two edges.
To obtain the fan speed, count the number of 90Khz pulses that occurs between 2 edges i.e., 2→3,
between 3 edges i.e., 2→4, or between 5 edges, i.e. 2→6 (the case of 9 edges is not shown). The
time from 1-2 occurs through the guard time and is not to be used. For the discussion below, an edge
is a high-to-low or low-to-high transition (edges are numbered – refer to Figure 7.7, "PWM and
Tachometer Concept").
The Tachometer circuit begins monitoring the tach when the associated PWM output transitions high
and the guard time has expired. Each tach circuit will continue monitoring until the programmed
number of edges has been detected, whichever comes first.
The Fan Tachometer value may be updated every 300ms, 500ms, or 1000ms.
SMSC EMC6D103S
41
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Internal PWM
Signal
PWM “ON”
Guard time A
Window for
Valid Tach
Pulses
1
2
3
4
5
6
A
B
C
D
E
F
Tach
Pulses
Tach
Pulses
Figure 7.7 PWM and Tachometer Concept
7.1.4.4.2
7.1.4.5
FAN TACHOMETER OPTIONS FOR MODE 2
„
2, 3, 5 or 9 “edges” to calculate the fan speed (Figure 7.7)
„
Guard time A is programmable (8-63 clocks) to account for delays in the system (Figure 7.7)
„
The PWM frequencies for modes 1 & 2 are: 11.0 Hz, 14.6 Hz, 21.9 Hz, 29.3 Hz, 35.2 Hz, 44.0 Hz,
58.6 Hz, 87.7Hz and 25Khz
„
Option to ignore first 3 tachometer edges after guard time
„
Option to force tach reading register to FFFEh to indicate a slow fan.
Fan Tachometer Reading Registers:
The Tachometer Reading registers are 16 bits, unsigned. When one byte of a 16-bit register is read,
the other byte latches the current value until it is read, in order to ensure a valid reading. The order
is LSB first, MSB second. The value FFFFh indicates that the fan is not spinning, or the tachometer
input is not connected to a valid signal (this could be triggered by a counter overflow). These registers
are read only – a write to these registers has no effect.
Notes:
„
The Fan Tachometer Reading registers always return an accurate fan tachometer measurement,
even when a fan is disabled or non-functional.
„
FFFFh indicates that the fan is not spinning, or the tachometer input is not connected to a valid
signal (This could be triggered by a counter overflow).
„
The Tachometer registers are read only – a write to these registers has no effect.
„
Mode 1 should be enabled and the tachometer limit register should be set to FFFFh if a tachometer
input is left unconnected.
Revision 0.2 (06-14-06)
42
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
7.1.4.6
Programming Options for Each Tachometer Input
The features defined in this section are programmable via the TACHx Option registers located at
offsets 90h-93h and the PWMx Option registers located at offsets 94h-96h.
7.1.4.6.1
TACH READING UPDATE TIME
In Mode 1, the Fan Tachometer Reading registers are continuously updated. In Mode 2, the fan
tachometer registers are updated every 300ms, 500msec, or 1000msec. This option is programmed
via bits[1:0] in the PWMx Option register. The PWM associated with a particular TACH(s) determines
the TACH update time.
7.1.4.6.2
PROGRAMMED NUMBER OF TACH EDGES
In modes 1 & 2, the number of edges is programmable for 2, 3, 5 or 9 edges (i.e., ½ tachometer pulse,
1 tachometer pulse, 2 tachometer pulses, 4 tachometer pulses). This option is programmed via bits[2:1]
in the TachX Option register.
Note: The “5 edges” case corresponds to two tachometer pulses, or 1 RPM for most fans. Using
the other edge options will require software to scale the values in the reading register to
correspond to the count for 1 RPM.
7.1.4.6.3
GUARD TIME (MODE 2 ONLY)
The guard time is programmable from 8 to 63 clocks (90kHz). This option is programmed via bits[4:3]
in the TachX Option register.
7.1.4.6.4
IGNORE FIRST 3 TACHOMETER EDGES (MODE 2 ONLY)
Option to ignore first 3 tachometer edges after guard time. This option is programmed for each
tachometer via bits[2:0] in the TACHx Option register. Default is do not ignore first 3 tachometer edges
after guard time.
7.1.4.7
Summary of Operation for Modes 1 & 2
The following summarizes the detection cases:
„
No edge occurs during the PWM ‘ON’ time: indicate this condition as a stalled fan
−The tachometer reading register contains FFFFh.
„
One edge (or less than programmed number of edges) occurs during the PWM ‘ON’ time :
indicate this condition as a slow fan.
−If the SLOW bit is set to 0, the tachometer reading register will be set to FFFEh to indicate that
this is a slow fan instead of a seized fan. Note: This operation also pertains to the case where the
tachometer counter reaches FFFFh before the programmed number of edges occurs.
−If the SLOW bit is set to one, the tachometer reading register will be set to FFFFh. In this case,
no distinction is made between a slow or seized fan.
Note: The Slow Interrupt feature (SLOW) is configured in the TACHx Options registers at offsets 90h
to 93h.
„
The programmed number of edges occurs:
-Mode 1: If the programmed number of edges occurs before the counter reaches FFFFh latch the
tachometer count
-Mode 2: If the programmed number of edges occurs during the PWM ‘ON’ time: latch the
tachometer count. (see Note below).
Notes:
„
Whenever the programmed number of edges is detected, the edge detection ends and the state
machine is reset. The tachometer reading register is updated with the tachometer count value at
this time. See Note 7.8 below for the one exception to this behavior.
SMSC EMC6D103S
43
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Note 7.8
7.1.4.8
This max value will be FFFFh if the programmed number of edges is detected when the
count reaches FFFFh or if no edges are detected. If the count reaches FFFFh in Mode 1
and some edges were detected, but less than the programmed number of edges, the
maximum tach count value is determined by the Slow Interrupt Enable bit located in the
TACHx Options registers at offsets 90h to 93h. If slow interrupt detection is set to 0, the
count will be forced to FFFEh, else the count will be forced to FFFFh.
Examples of Minimum RPMs Supported
The following tables show minimum RPMs that can be supported with the different parameters. The
first table uses 3 edges and the second table uses 2 edges.
As described in Assumptions (refer to Figure 7.7, "PWM and Tachometer Concept"): on page 41, the
TACH detection circuitry expects a fan to deliver 5 TACH edges per full revolution. When measuring
the fan speed using a PWM drive, the slowest fan speed that can be measured is dependent upon
how long the PWM drive is high as well as how many edges are being counted to make a valid
measurement.
The data shown in Table 7.2 is taken by measuring 3 TACH edges or 1/2 of a single rotation. If the
TACH signal is seen as a square wave with a fixed duty cycle and variable period (where period is
inversely proportional to the fan speed), then 3 edges would coincide with a single TACH pulse.
Therefore, in order to accurately measure a TACH signal using 3 edges, the PWM must be high for
at least as long as the full period of the TACH signal.
For example, if the PWM frequency is 87.7Hz (1st row), then the maximum measurement time
available is 11.36msec at 100% duty cycle. This implies, that the maximum period that can be
measured is also 11.36msec. Because period is inversely proportional to fan speed and 1 full period
is equivalent to 1/2 a single rotation, this means that the minimum fan speed that can be detected at
100% duty cycle is:
1 - 1
1000 ms 60 s
---------------------× --- rotation × ---------------------- × ---------- = 2641
11.36 ms 2
s
min
The values shown in Table 7.2 and Table 7.3 include a guard time that occurs immediately after the
PWM is set high where the TACH pulse is not measured. The effect of this guard time is to reduce
the effective “on” time of the PWM with respect to measuring a TACH pulse.
Table 7.2 Minimum RPM Detectable Using 3 Edges
PWM
FREQUENCY
PULSE WIDTH AT DUTY CYCLE
(PWM ”ON” TIME)
MINIMUM RPM AT DUTY CYCLE (Note 7.10)
(30/TTachPulse)
(HZ)
25%
(MSEC)
50%
(MSEC)
100%
(MSEC)
(Note 7.9)
25%
50%
100%
87.7
2.85
5.7
11.36
10865
5347
2662
58.6
4.27
8.53
17
7175
3554
1774
44
5.68
11.36
22.64
5366
2662
1330
35.2
7.1
14.2
28.3
4279
2126
1063
29.3
8.53
17.06
34
3554
1768
885
21.9
11.42
22.83
45.48
2648
1319
661
14.6
17.12
34.25
68.23
1761
878
440
11
22.73
45.45
90.55
1325
661
332
Revision 0.2 (06-14-06)
44
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Note 7.9
100% duty cycle is 255/256.
Note 7.10 RPM=60/TRevolution, TTachPulse= TRevolution/2. Using 3 edges for detection, TTachPulse =
(PWM ”ON” Time – Guard Time). Minimum RPM values shown use minimum guard time
(88.88usec).
Table 7.3 Minimum RPM Detectable Using 2 Edges
PWM
FREQUENCY
PULSE WIDTH AT DUTY CYCLE
(PWM ”ON” TIME)
MINIMUM RPM AT DUTY CYCLE (Note 7.12)
(30/TTachPulse)
(HZ)
25%
(MSEC)
50%
(MSEC)
100%
(MSEC)
(Note 7.11)
25%
50%
100%
87.7
2.85
5.7
11.36
5433
2673
1331
58.6
4.27
8.53
17
3588
1777
887
44
5.68
11.36
22.64
2683
1331
665
35.2
7.1
14.2
28.3
2139
1063
532
29.3
8.53
17.06
34
1777
884
442
21.9
11.42
22.83
45.48
1324
660
330
14.6
17.12
34.25
68.23
881
439
220
11
22.73
45.45
90.55
663
331
166
Note 7.11 100% duty cycle is 255/256
Note 7.12 RPM=60/TRevolution, TTachPulse= TRevolution/2. Using 2 edges for detection, TTachPulse =
2*(PWM ”ON” Time-Guard Time). Minimum RPM values shown use minimum guard time
(88.88usec).
7.1.4.9
Detection of a Stalled Fan
There is a fan failure bit (TACHx) in the interrupt status register used to indicate that a slow or stalled
fan event has occurred. If the tach reading value exceeds the value programmed in the tach limit
register the interrupt status bit is set. See Interrupt Status register 2 at offset 42h.
Notes:
7.1.4.10
„
The reading register will be forced to FFFFh if a stalled event occurs (i.e., stalled event =no edges
detected.)
„
The reading register will be forced to either FFFFh or FFFEh if a slow fan event occurs. (i.e., slow
event: 0 < #edges < programmed #edges). If the control bit, SLOW, located in the TACHx Options
registers at offsets 90h - 93h, is set then FFFEh will be forced into the corresponding Tach Reading
Register to indicate that the fan is spinning slowly.
„
The fan tachometer reading register stays at FFFFh in the event of a stalled fan. If the fan begins
to spin again, the tachometer logic will reset and latch the next valid reading into the tachometer
reading register.
Fan Interrupt Status Bits
The status bits for the fan events are in Interrupt Status Register 2 (42h). These bits are set when the
reading register is above the tachometer minimum and the Interrupt Enable 2 (Fan Tachs) register bits
are configured to enable Fan Tach events. No interrupt status bits are set for fan events (even if the
fan is stalled) if the associated tachometer minimum is set to FFFFh (registers 54h-5Bh).
SMSC EMC6D103S
45
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Note: The Interrupt Enable 2 (Fan Tachs) register at offset 80h defaults to enabled for the individual
tachometer status events bits. The group Fan Tach INT# bit defaults to disabled. This bit needs
to be set if Fan Tach interrupts are to be generated on the external INT# pin.
See Figure 6.3 Interrupt Control on page 25.
7.1.5
Linking Fan Tachometers to PWMs
The TACH/PWM Association Register at offset 81h is used to associate a Tachometer input with a
PWM output. This association has three purposes:
1. The auto fan control logic supports a feature called SpinUp Reduction. If SpinUp Reduction is
enabled (SUREN bit), the auto fan control logic will stop driving the PWM output high if the
associated TACH input is operating within normal parameters. (Note: SUREN bit is located in the
Configuration Register at offset 7Fh)
2. To measure the tachometer input in Mode 2, the tachometer logic must know when the associated
PWM is ‘ON’.
3. Inhibit fan tachometer interrupts when the associated PWM is ‘OFF’.
See the description of the PWM_TACH register. The default configuration is:
PWM1 -> TACH1.
PWM2 -> TACH2.
PWM3 -> TACH3 & TACH4.
Revision 0.2 (06-14-06)
46
DATASHEET
SMSC EMC6D103S
Revision 0.2 (06-14-06)
Chapter 8 Register Set
Definition for the Lock and Start columns:
Yes = Register is made read-only when the related bit is set; No = Register is not made read-only when the related bit is set.
Reg
Addr
Read
/Write
Reg Name
Bit 7
MSb
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
LSb
Default
Value
Lock
Start
20h
R
+2.5V Reading
7
6
5
4
3
2
1
0
N/A
No
No
21h
R
Vccp Reading
7
6
5
4
3
2
1
0
N/A
No
No
22h
R
VCC Reading
7
6
5
4
3
2
1
0
N/A
No
No
23h
R
+5V Reading
7
6
5
4
3
2
1
0
N/A
No
No
24h
R
+12V Reading
7
6
5
4
3
2
1
0
N/A
No
No
25h
R
Remote Diode 1 Temp Reading
7
6
5
4
3
2
1
0
N/A
No
No
26h
R
Internal Temp Reading
7
6
5
4
3
2
1
0
N/A
No
No
27h
R
Remote Diode 2 Temp Reading
7
6
5
4
3
2
1
0
N/A
No
No
28h
R
Tach1 LSB
7
6
5
4
3
2
1
0
N/A
No
No
29h
R
Tach1 MSB
15
14
13
12
11
10
9
8
N/A
No
No
2Ah
R
Tach2 LSB
7
6
5
4
3
2
1
0
N/A
No
No
2Bh
R
Tach2 MSB
15
14
13
12
11
10
9
8
N/A
No
No
2Ch
R
Tach3 LSB
7
6
5
4
3
2
1
0
N/A
No
No
2Dh
R
Tach3 MSB
15
14
13
12
11
10
9
8
N/A
No
No
2Eh
R
Tach4 LSB
7
6
5
4
3
2
1
0
N/A
No
No
2Fh
R
Tach4 MSB
15
14
13
12
11
10
9
8
N/A
No
No
30h
R/W
PWM1 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
Yes
No
Note 8.1
R/W
Note 8.1
PWM2 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
Note 8.1
32h
R/W
Yes
No
Note 8.1
PWM3 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
Note 8.1
Yes
No
Note 8.1
3Eh
R
Company ID
7
6
5
4
3
2
1
0
5Ch
No
No
3Fh
R
Version / Stepping
VER3
VER2
VER1
VER0
STP3
STP2
STP1
STP0
6Ah
No
No
40h
R/W
Ready/Lock/Start
RES
RES
RES
RES
OVRID
READY
LOCK
START
00h
Yes
No
Note 8.2
Note 8.2
SMSC EMC6D103S
31h
47
DATASHEET
Table 8.1 Register Summary
41h
Read
/Write
Reg Name
Bit 7
MSb
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
LSb
Default
Value
Lock
Start
R-C
Interrupt Status Register 1
INT2
D2
AMB
D1
5V
VCC
Vccp
2.5V
00h
No
No
Interrupt Status Register 2
ERR2
ERR1
TACH4
TACH3
TACH2
TACH1
RES
12V
00h
No
No
VID0-4
RES
RES
RES
VID4
VID3
VID2
VID1
VID0
N/A
No
No
Note 8.3
42h
R-C
Note 8.3
48
DATASHEET
SMSC EMC6D103S
43h
R
44h
R/W
2.5V Low Limit
7
6
5
4
3
2
1
0
00h
No
No
45h
R/W
2.5V High Limit
7
6
5
4
3
2
1
0
FFh
No
No
46h
R/W
Vccp Low Limit
7
6
5
4
3
2
1
0
00h
No
No
47h
R/W
Vccp High Limit
7
6
5
4
3
2
1
0
FFh
No
No
48h
R/W
VCC Low Limit
7
6
5
4
3
2
1
0
00h
No
No
49h
R/W
VCC High Limit
7
6
5
4
3
2
1
0
FFh
No
No
4Ah
R/W
5V Low Limit
7
6
5
4
3
2
1
0
00h
No
No
4Bh
R/W
5V High Limit
7
6
5
4
3
2
1
0
FFh
No
No
4Ch
R/W
12V Low Limit
7
6
5
4
3
2
1
0
00h
No
No
4Dh
R/W
12V High Limit
7
6
5
4
3
2
1
0
FFh
No
No
4Eh
R/W
Remote Diode 1 Low Temp
7
6
5
4
3
2
1
0
81h
No
No
4Fh
R/W
Remote Diode 1 High Temp
7
6
5
4
3
2
1
0
7Fh
No
No
50h
R/W
Internal Low Temp
7
6
5
4
3
2
1
0
81h
No
No
51h
R/W
Internal High Temp
7
6
5
4
3
2
1
0
7Fh
No
No
52h
R/W
Remote Diode 2 Low Temp
7
6
5
4
3
2
1
0
81h
No
No
53h
R/W
Remote Diode 2 High Temp
7
6
5
4
3
2
1
0
7Fh
No
No
54h
R/W
Tach1 Minimum LSB
7
6
5
4
3
2
1
0
FFh
No
No
55h
R/W
Tach1 Minimum MSB
15
14
13
12
11
10
9
8
FFh
No
No
56h
R/W
Tach2 Minimum LSB
7
6
5
4
3
2
1
0
FFh
No
No
57h
R/W
Tach2 Minimum MSB
15
14
13
12
11
10
9
8
FFh
No
No
58h
R/W
Tach3 Minimum LSB
7
6
5
4
3
2
1
0
FFh
No
No
59h
R/W
Tach3 Minimum MSB
15
14
13
12
11
10
9
8
FFh
No
No
5Ah
R/W
Tach4 Minimum LSB
7
6
5
4
3
2
1
0
FFh
No
No
5Bh
R/W
Tach4 Minimum MSB
15
14
13
12
11
10
9
8
FFh
No
No
5Ch
R/W
PWM 1 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
Yes
No
5Dh
R/W
PWM 2 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
Yes
No
5Eh
R/W
PWM 3 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
Yes
No
5Fh
R/W
Zone 1 Range/PWM 1 Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
Yes
No
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Reg
Addr
Datasheet
Revision 0.2 (06-14-06)
Table 8.1 Register Summary (continued)
Read
/Write
Reg Name
Bit 7
MSb
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
LSb
Default
Value
Lock
Start
60h
R/W
Zone 2 Range/PWM 2 Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
Yes
No
61h
R/W
Zone 3 Range/PWM 3 Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
Yes
No
62h
R/W
PWM1 Ramp Rate Control
RES
RES
RES
RES
RR1E
RR1-2
RR1-1
RR1-0
E0h
Yes
No
63h
R/W
PWM 2, PWM3 Ramp Rate Control
RR2E
RR2-2
RR2-1
RR2-0
RR3E
RR3-2
RR3-1
RR3-0
00h
Yes
No
64h
R/W
PWM 1 MINIMUM Duty Cycle
7
6
5
4
3
2
1
0
80h
Yes
No
65h
R/W
PWM 2 MINIMUM Duty Cycle
7
6
5
4
3
2
1
0
80h
Yes
No
66h
R/W
PWM 3 MINIMUM Duty Cycle
7
6
5
4
3
2
1
0
80h
Yes
No
67h
R/W
Zone 1 Low Temp Limit
7
6
5
4
3
2
1
0
80h
Yes
No
68h
R/W
Zone 2 Low Temp Limit
7
6
5
4
3
2
1
0
80h
Yes
No
69h
R/W
Zone 3 Low Temp Limit
7
6
5
4
3
2
1
0
80h
Yes
No
6Ah
R/W
Zone 1 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
Yes
No
6Bh
R/W
Zone 2 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
Yes
No
6Ch
R/W
Zone 3 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
Yes
No
6Fh
R/W
XOR Test Tree Enable
RES
RES
RES
RES
RES
RES
RES
XEN
00h
Yes
No
R/W
Special Function Register
AVG2
AVG1
AVG0
SMSC
SMSC
INTEN
MON-MD
LPMD
40h
Yes
No
7Ch
Note 8.4
Note 8.7 Note 8.7
Note 8.5
Note 8.4
7Dh
R
Reserved
RES
RES
RES
RES
RES
RES
RES
RES
00h
No
No
7Eh
R/W
Interrupt Enable 1 (Voltages)
VCC
12V
5V
RES
VCCP
25V
RES
VOLT
ECh
Yes
No
7Fh
R/W
Configuration
INIT
SMSC
SMSC
SUREN
TRDY
RES
P2INT
T3INT
10h
Yes
No
Revision 0.2 (06-14-06)
Reg
Addr
49
DATASHEET
Table 8.1 Register Summary (continued)
80h
R/W
Interrupt Enable 2 (Fan Tachs)
RES
RES
RES
TACH4
TACH3
TACH2
TACH1
TACH
1Eh
Yes
No
81h
R/W
TACH_PWM Association
T4H
T4L
T3H
T3L
T2H
T2L
T1H
T1L
A4h
Yes
No
82h
R/W
Interrupt Enable 3 (Temp)
RES
RES
RES
RES
D2EN
D1EN
AMB
TEMP
0Eh
Yes
No
85h
R
A/D Converter LSbs Reg 1
RD2.3
RD2.2
RD2.1
RD2.0
RD1.3
RD1.2
RD1.1
RD1.0
N/A
No
No
86h
R
A/D Converter LSbs Reg 2
V12.3
V12.2
V12.1
V12.0
AM.3
AM.2
AM.1
AM.0
N/A
No
No
87h
R
A/D Converter LSbs Reg 3
V50.3
V50.2
V50.1
V50.0
V25.3
V25.2
V25.1
V25.0
N/A
No
No
SMSC EMC6D103S
Note 8.7 Note 8.7
Read
/Write
Reg Name
Bit 7
MSb
Bit 6
Bit 5
Bit 4
Default
Value
Lock
Start
88h
R
A/D Converter LSbs Reg 4
VCC.3
VCC.2
VCC.1
90h
R/W
Tach1 Option
RES
RES
RES
VCP.0
N/A
No
No
SLOW
04h
No
91h
R/W
Tach2 Option
RES
RES
No
SLOW
04h
No
No
92h
R/W
Tach3 Option
RES
93h
R/W
Tach4 Option
RES
EDG0
SLOW
04h
No
No
EDG0
SLOW
04h
No
94h
R/W
PWM1 Option
RES
RES
No
SZEN
UPDT1
UPDT0
0Ch
Yes
No
GRD0
SZEN
UPDT1
UPDT0
0Ch
Yes
No
GRD1
GRD0
SZEN
UPDT1
UPDT0
0Ch
Yes
No
TST 4
TST3
TST2
TST1
TST0
N/A
No
No
Bit 3
Bit 2
Bit 1
VCC.0
VCP.3
VCP.2
VCP.1
3EDG
MODE
EDG1
EDG0
RES
3EDG
MODE
EDG1
EDG0
RES
RES
3EDG
MODE
EDG1
RE S
RES
3EDG
MODE
EDG1
OPP
GRD1
GRD0
OPP
GRD1
OPP
TST 5
Bit 0
LSb
Note 8.6 Note 8.6
95h
R/W
PWM2 Option
RES
RES
Note 8.6 Note 8.6
96h
R/W
PWM3 Option
RES
RES
Note 8.6 Note 8.6
FFh
R
SMSC Test Register
TST7
TST 6
Note: SMSC Test Registers may be read/write registers. Writing these registers can cause unwanted results.
50
DATASHEET
Note 8.1
The PWMx Current Duty Cycle Registers are only writable when the associated fan is in manual mode. In this case, the register is writable
when the start bit is set, but not when the lock bit is set.
Note 8.2
The Lock bit in the Ready/Lock/Start register is locked by the Lock Bit. The START and OVRID bits are always writable, both when the start
bit is set and when the lock bit is set.
Note 8.3
The Interrupt status registers are cleared on a read if no events are active
Note 8.4
The INTEN bit in register 7Ch is always writable, both when the start bit is set and when the lock bit is set.
Note 8.5
In Shutdown Mode (LPMD=1 & START=0) all the H/W Monitoring registers/bits are not accessible except for the following: Bits[2:0] in the
Special Function Register (SFTR) at offset 7Ch and Bits[7:0] in the Configuration register at offset 7Fh.
Note 8.6
These Reserved bits are read/write bits. Writing these bits to a ‘1’ has no effect on the hardware.
Note 8.7
SMSC bits may be read/write bits. Writing these bits to a value other than the default value may cause unwanted results
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Reg
Addr
Datasheet
Revision 0.2 (06-14-06)
Table 8.1 Register Summary (continued)
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.1
Undefined Registers
The registers shown in Table 8.1, "Register Summary" above are the defined registers in the part. Any
reads to undefined registers always return 00h. Writes to undefined registers have no effect and do
not return an error.
8.2
Defined Registers
8.2.1
Registers 20-24h: Voltage Reading
Table 8.2 Registers 20-24h: Voltage Reading
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
20h
R
+2.5V Reading
7
6
5
4
3
2
1
0
N/A
21h
R
Vccp Reading
7
6
5
4
3
2
1
0
N/A
22h
R
VCC Reading
7
6
5
4
3
2
1
0
N/A
23h
R
+5V Reading
7
6
5
4
3
2
1
0
N/A
24h
R
+12V Reading
7
6
5
4
3
2
1
0
N/A
The Voltage Reading registers reflect the current voltage of the EMC6D103S voltage monitoring inputs.
Voltages are presented in the registers at ¾ full scale for the nominal voltage, meaning that at nominal
voltage, each register will read C0h.
Table 8.3 Voltage vs. Register Reading
NOMINAL
VOLTAGE
REGISTER
READING AT
NOMINAL
VOLTAGE
+2.5V
2.5V
Vccp
2.25V
VCC
+5V
+12V
INPUT
MAXIMUM
VOLTAGE
REGISTER
READING AT
MAXIMUM
VOLTAGE
MINIMUM
VOLTAGE
REGISTER
READING AT
MINIMUM VOLTAGE
C0h
3.32V
FFh
0V
00h
C0h
3.00V
FFh
0V
00h
3.3V
C0h
4.38V
FFh
0V
00h
5.0V
C0h
6.64V
FFh
0V
00h
12.0V
C0h
16.00V
FFh
0V
00h
The Voltage Reading registers will be updated automatically by the EMC6D103S Chip with a minimum
frequency of 4Hz. These registers are read only – a write to these registers has no effect.
8.2.2
Registers 25-27h: Temperature Reading
Table 8.4 Registers 25-27h: Temperature Reading
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
25h
R
Remote Diode 1 Temp Reading
7
6
5
4
3
2
1
0
N/A
26h
R
Internal Temp Reading
7
6
5
4
3
2
1
0
N/A
27h
R
Remote Diode 2 Temp Reading
7
6
5
4
3
2
1
0
N/A
SMSC EMC6D103S
51
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
The Temperature Reading registers reflect the current temperatures of the internal and remote diodes.
Remote Diode 1 Temp Reading register reports the temperature measured by the Remote1- and
Remote1+ pins, Remote Diode 2 Temp Reading register reports the temperature measured by the
Remote2- and Remote2+ pins, and the Internal Temp Reading register reports the temperature
measured by the internal (ambient) temperature sensor. Current temperatures are represented as 8
bit, 2’s complement, signed numbers in Celsius, as shown below in Table 8.5. The Temperature
Reading register will return a value of 80h if the remote diode pins are not implemented by the board
designer or are not functioning properly (this corresponds to the diode fault interrupt status bits). The
Temperature Reading registers will be updated automatically by the EMC6D103S Chip with a minimum
frequency of 4Hz.
Note: These registers are read only – a write to these registers has no effect.
Each of the temperature reading registers are mapped to a zone. Each PWM may be programmed to
operate in the auto fan control operating mode by associating a PWM with one or more zones. The
following is a list of the zone associations.
„
Zone 1 is controlled by Remote Diode 1 Temp Reading
„
Zone 2 is controlled by Internal Temp Reading (Ambient Temperature Sensor)
„
Zone 3 is controlled by Remote Diode 2 Temp Reading
Table 8.5 Temperature vs. Register Reading
TEMPERATURE
READING (DEC)
READING (HEX)
-127°c
-127
81h
.
.
.
.
.
.
.
.
.
-50°c
-50
CEh
.
.
.
.
.
.
.
.
.
0°c
0
00h
.
.
.
.
.
.
.
.
.
50°c
50
32h
.
.
.
.
.
.
.
.
.
127°c
127
7Fh
(SENSOR ERROR)
8.2.3
80h
Registers 28-2Fh: Fan Tachometer Reading
Table 8.6 Registers 28-2Fh: Fan Tachometer Reading
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
28h
R
Tach1 LSB
7
6
5
4
3
2
1
0
N/A
29h
R
Tach1 MSB
15
14
13
12
11
10
9
8
N/A
2Ah
R
Tach2 LSB
7
6
5
4
3
2
1
0
N/A
2Bh
R
Tach2 MSB
15
14
13
12
11
10
9
8
N/A
2Ch
R
Tach3 LSB
7
6
5
4
3
2
1
0
N/A
Revision 0.2 (06-14-06)
52
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.6 Registers 28-2Fh: Fan Tachometer Reading (continued)
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
2Dh
R
Tach3 MSB
15
14
13
12
11
10
9
8
N/A
2Eh
R
Tach4 LSB
7
6
5
4
3
2
1
0
N/A
2Fh
R
Tach4 MSB
15
14
13
12
11
10
9
8
N/A
The Fan Tachometer Reading registers contain the number of 11.111μs periods (90KHz) between full
fan revolutions. Fans produce two tachometer pulses per full revolution. These registers are updated
at least once every second.
To convert the value in the TACH reading registers to a representative RPM value is a simple
mathematical exercise. The 16bit reading is first converted to a decimal number and then multiplied
by the clock period (11.11μs). This gives the measured period of two full TACH pulses which equals
1 full fan revolution. This number is then inverted and multiplied by 60 to give Rotations / minute.
For example: If the Tach 1 data bytes contain 0C86h (MSB followed by LSB). This is equivalent to
3206 clock counts. Multiplying this number by 11.111μs (clock period) yields 0.03562s. This number
represents the measured time for two full periods of the TACH signal. Inverting this number and
multiplying it by 60 yields a final RPM value of 1684.
The larger the returned count, the slower the measured fan speed. The slowest fan speed that can be
stored is approximately 82RPM with an output code of FFFDh. This slow speed is not practical to
measure in TACH monitoring Mode 2 (see Table 7.2 on page 44 and Table 7.3 on page 45 for minimum
RPM’s measured using Mode 2 and Section 7.1.4.4, "Mode 2 – Monitor Tach input When PWM is
‘ON’," on page 41 for a description of this monitoring mode).
This value is represented for each fan in a 16 bit, unsigned number.
The Fan Tachometer Reading registers always return an accurate fan tachometer measurement, even
when a fan is disabled or non-functional, including when the start bit=0.
When one byte of a 16-bit register is read, the other byte latches the current value until it is read, in
order to ensure a valid reading. The order is LSB first, MSB second.
FFFFh indicates that the fan is not spinning, or the tachometer input is not connected to a valid signal
(This could be triggered by a counter overflow).
FFFEh, if the SLOW bit in the corresponding TACHx Option register is set (see Section 8.2.28,
"Registers 90h-93h: TachX Option Registers," on page 75 for details), indicates that fan is spinning,
but too slowly to be measured at the current TACH settings.
These registers are read only – a write to these registers has no effect.
8.2.4
Registers 30-32h: Current PWM Duty
Table 8.7 Registers 30-32h: Current PWM Duty
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
30h
R/W
(See
Note 8.8)
PWM1 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
31h
R/W
(See
Note 8.8)
PWM2 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
32h
R/W
(See
Note 8.8)
PWM3 Current Duty Cycle
7
6
5
4
3
2
1
0
N/A
SMSC EMC6D103S
53
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Note 8.8
These registers are only writable when the associated fan is in manual mode. These
registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
The Current PWM Duty registers store the duty cycle that the chip is currently driving the PWM signals
at. At initial power-on, the duty cycle is 100% and thus, when read, this register will return FFh. After
the Ready/Lock/Start Register Start bit is set, this register and the PWM signals are updated based
on the algorithm described in the Auto Fan Control Operating Mode section and the Ramp Rate
Control logic, unless the associated fan is in manual mode – see below.
Note: When the device is configured for Manual Mode, the Ramp Rate Control logic should be
disabled.
When read, the Current PWM Duty registers return the current PWM duty cycle for the respective
PWM signal.
These registers are read only – a write to these registers has no effect.
Note: If the current PWM duty cycle registers are written while the part is not in manual mode or
when the start bit is zero, the data will be stored in internal registers that will only be active
and observable when the start bit is set and the fan is configured for manual mode. While the
part is not in manual mode and the start bit is zero, the current PWM duty cycle registers will
read back FFh.
Manual Mode (Test Mode)
In manual mode, when the start bit is set to 1 and the lock bit is 0, the current duty cycle registers are
writable to control the PWMs.
Note: When the lock bit is set to 1, the current duty cycle registers are Read-Only.
The PWM duty cycle is represented as follows:
Table 8.8 PWM Duty vs Register Reading
0%
0
00h
100%
80h
…
128
…
…
50%
40h
…
64
…
…
25%
…
VALUE (HEX)
…
VALUE (DECIMAL)
…
CURRENT DUTY
255
FFh
During spin-up, the PWM duty cycle is reported as 0%.
Notes:
„
The PWMx Current Duty Cycle always reflects the current duty cycle on the associated PWM pin.
„
The PWMx Current Duty Cycle register is implemented as two separate registers: a read-only and
a write-only. When a value is written to this register in manual mode there will be a delay before
the programmed value can be read back by software. The hardware updates the read-only PWMx
Current Duty Cycle register on the beginning of a PWM cycle. If Ramp Rate Control is disabled,
the delay to read back the programmed value will be from 0 seconds to 1/(PWM frequency)
seconds. Typically, the delay will be 1/(2*PWM frequency) seconds.
Revision 0.2 (06-14-06)
54
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.5
Register 3Eh: Company ID
Table 8.9 Register 3Eh: Company ID
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
3Eh
R
Company ID
7
6
5
4
3
2
1
0
5Ch
The Company ID register contains the company identification number. This number is a method for
uniquely identifying the part manufacturer.
This register is read only – a write to this register has no effect.
8.2.6
Register 3Fh: Version / Stepping
Table 8.10 Register 3Fh: Version / Stepping
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
3Fh
R
Version / Stepping
VER3
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
VER
2
VER
1
VER
0
STP
3
STP
2
STP
1
Bit 0
(LSb)
Default
Value
STP0
6Ah
The four least significant bits of the Version / Stepping register [3:0] contain the current stepping of the
EMC6D103S silicon. Stepping numbers are to begin from a value of 08h, to indicate that the register
set is enhanced from previous hardware monitoring standards. The four most significant bits [7:4]
reflect the version number, which will be fixed at 0110b. For the A0 stepping of this device, the register
will read 01101000b. For the A1 stepping, this register will read 01101001b and so on.
The register is used by application software to identify which device has been implemented in the given
system. Based on this information, software can determine which registers to read from and write to.
Further, application software may use the current stepping to implement work-arounds for bugs found
in a specific silicon stepping. This register is read only – a write to this register has no effect.
8.2.7
Register 40h: Ready/Lock/Start Monitoring
Table 8.11 Register 40h: Ready/Lock/Start Monitoring
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
40h
R/W
Ready/Lock/Start
RES
RES
RES
RES
OVRID
READY
LOCK
START
00h
Setting the Lock bit makes the Lock bit read only.
SMSC EMC6D103S
55
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.12 Ready/Lock/Start Monitoring
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
START
R/W
0
When software writes a 1 to this bit, the EMC6D103S enables
monitoring and PWM output control functions based on the limit and
parameter registers. Before this bit is set, the part does not update
register values. Whenever this bit is set to 0, the monitoring and PWM
output control functions are based on the default limits and
parameters, regardless of the current values in the limit and parameter
registers. The EMC6D103S preserves the values currently stored in the
limit and parameter registers when this bit is set or cleared. This bit is
not affected by setting the Lock bit.
Note:
When this bit is 0, all fans are on full 100% duty cycle, i.e.,
PWM pins are high for 255 clocks, low for 1 clock. When this
bit is 0, the part is not monitoring.
1
LOCK
R/W
0
Setting this bit to 1 locks specified limit and parameter registers. Once
this bit is set, limit and parameter registers become read only and will
remain locked until the device is powered off. This register bit becomes
read only once it is set.
2
READY
R
0
The EMC6D103S sets this bit automatically after the part is fully
powered up, has completed the power-up-reset process, and after all
A/D converters are functioning (all bias conditions for the A/Ds have
stabilized and the A/Ds are in operational mode). (Always reads back
‘1’.)
3
OVRID
R/W
0
If this bit is set to 1, all PWM outputs go to 100% duty cycle regardless
of whether or not the lock bit is set.
4-7
Reserved
R
0
Reserved.
Note: There is a start-up time of up to 82ms for monitoring after the start bit is set to ‘1’, during which
time the reading registers are not valid.
The following summarizes the operation of the part based on the Start bit:
1. If Start bit = '0' then:
a. Fans are set to Full On.
b. No voltage, temperature, or fan tach monitoring is performed. The values in the reading registers
will be N/A (Not Applicable), which means these values will not be considered valid readings until
the Start bit = '1'. The exception to this is the Tachometer reading registers, which always give the
actual reading on the TACH pins.
c. No Status bits are set.
2. If Start bit = '1'
d. All fan control and monitoring will be based on the current values in the registers. There is no need
to preserve the default values after software has programmed these registers because no
monitoring or auto fan control will be done when Start bit = '0'.
e. Status bits may be set.
f.
Setting the START bit to 1 does not prevent the limit and parameter registers from being written.
Note: Once programmed, the register values will be saved when start bit is reset to ‘0’.
Revision 0.2 (06-14-06)
56
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.8
Register 41h: Interrupt Status Register 1
Table 8.13 Register 41h: Interrupt Status Register 1
Register
Address
Read/
Write
41h
R-C
(See
Note 8.9)
Note 8.9
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
Interrupt Status 1
INT2
D2
AMB
D1
5V
VCC
Vccp
2.5V
00h
This register is cleared on a read if no events are active.
Note: The individual enable bits for D2, AMB, and D1 are located in the Interrupt Enable 3 (Temp)
register at offset 82h. The individual enable bits for5V, 2.5V, VCC, and Vccp, are located in the
Interrupt Enable 1 register at offset 7Eh.
The Interrupt Status Register 1 bits are automatically set by the device, if enabled, whenever the 2.5V,
Vccp, 3.3V, or 5V input voltages violate the limits set in the limit and parameter registers or when the
measured temperature violates the limits set in the limit and parameter registers for any of the three
thermal inputs.
This register holds a bit set until the event is read by software or until the individual enable bit is
cleared (see Note below). The contents of this register are cleared (set to 0) automatically by the
EMC6D103S after it is read by software, if the voltage or temperature no longer violates the limits set
in the limit and parameter registers. Once set, the Interrupt Status Register 1 bits remain set until a
read event occurs or until the individual enable bits is cleared, even if the voltage or temperature no
longer violate the limits set in the limit and parameter registers. Note that clearing the group Temp,
Fan, or Volt enable bits or the global INTEN enable bit has no effect on the status bits. See Registers
44-4Dh: Voltage Limit Registers on page 60 and on page 60.
This register contains a bit that indicates that a bit is set in the other interrupt status register. If bit 7
is set, then a status bit is set in the Interrupt Status Register 2. Therefore, S/W can poll this register,
and only if bit 7 is set does the other register need to be read. This bit is cleared (set to 0) automatically
by the device if there are no bits set in Interrupt Status Registers 2.
This register is read only – a write to this register has no effect.
Note: Clearing the individual enable bits:
1. An interrupt status bit will never change from a 0 to a 1 when the corresponding individual interrupt
enable bit is cleared (set to 0), regardless of whether the limits are violated during a measurement.
2. If the individual enable bit is cleared while the associated status bit is 1, the status bit will be
cleared when the associated reading register is updated. The reading registers only get updated
when the START bit is set to ‘1’. If the enable bit is cleared when the START bit is 0, the associated
interrupt status bit will not be cleared until the start bit is set to 1 and the associated reading register
is updated.
SMSC EMC6D103S
57
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.14 Interrupt Status Register 1
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
2.5V_Error
R
0
The EMC6D103S automatically sets this bit to 1 when the 2.5V input
voltage is less than or equal to the limit set in the 2.5V Low Limit register
or greater than the limit set in the 2.5V High Limit register.
1
Vccp_Error
R
0
The EMC6D103S automatically sets this bit to 1 when the Vccp input
voltage is less than or equal to the limit set in the Vccp Low Limit register
or greater than the limit set in the Vccp High Limit register.
2
VCC_Error
R
0
The EMC6D103S automatically sets this bit to 1 when the VCC input
voltage is less than or equal to the limit set in the VCC Low Limit register
or greater than the limit set in the VCC High Limit register.
3
5V_Error
R
0
The EMC6D103S automatically sets this bit to 1 when the 5V input
voltage is less than or equal to the limit set in the 5V Low Limit register
or greater than the limit set in the 5V High Limit register.
4
Remote
Diode 1 Limit
Error
R
0
The EMC6D103S automatically sets this bit to 1 when the temperature
input measured by the Remote1- and Remote1+ is less than or equal to
the limit set in the Remote Diode 1 Low Temp register or greater than the
limit set in Remote Diode 1 High Temp register.
5
Internal
Sensor Limit
Error
R
0
The EMC6D103S automatically sets this bit to 1 when the temperature
input measured by the internal temperature sensor is less than or equal
to the limit set in the Internal Low Temp register or greater than the limit
set in the Internal High Temp register.
6
Remote
Diode 2 Limit
Error
R
0
The EMC6D103S automatically sets this bit to 1 when the temperature
input measured by the Remote2- and Remote2+ is less than or equal to
the limit set in the Remote Diode 2 Low Temp register or greater than the
limit set in the Remote Diode 1 High Temp register.
7
INT2 Event
Active
R
0
The device automatically sets this bit to 1 when a status bit is set in the
Interrupt Status Register 2.
8.2.9
Register 42h: Interrupt Status Register 2
Table 8.15 Register 42h: Interrupt Status Register 2
Register
Address
Read/
Write
42h
R-C
(See
Note
8.10)
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
Interrupt Status Register 2
ERR2
ERR1
TACH4
TACH3
TACH2
TACH1
RES
12V
00h
Note 8.10 This register is cleared on a read if no events are active.
This register is read only – a write to this register has no effect.
The Interrupt Status Register 2 bits are automatically set by the device whenever a remote temperature
sensor error occurs, a tach reading value is above the minimum value set in the tachometer minimum
registers, or whenever the 12V input voltage violates the limits set in the limit and parameter registers.
The Interrupt Status Register 2 register holds a set bit until the event is read by software or until the
individual interrupt enable bit is cleared (see Note below).
The contents of this register are cleared (set to 0) automatically by the EMC6D103S after it is read by
software, if the voltage no longer violate the limits set in the limit and parameter registers, if the
temperature sensor error no loner exists, or if the tach reading register is no longer above the
minimum. Once set, the Interrupt Status Register 2 bits remain set until a read event occurs or until
the individual interrupt enable bit is cleared, even if the voltage, Tach, or diode event no longer exists.
Revision 0.2 (06-14-06)
58
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
The remote diode fault bits do not clear on a read while the fault condition exists. If the start bit is set
when a fault condition occurs, 80h will be loaded into the associated temperature reading register,
which will cause the associated diode limit error bit to be set (Remote Diode 1 Limit Error or Remote
Diode 2 Limit Error) in addition to the diode fault bit. Disabling the enable bit for the diode will clear
both the fault bit and the error bit for that diode (see Note below).
This register is read only – a write to this register has no effect.
Note: Clearing the individual enable bits.
1. An interrupt status bit will never change from a 0 to a 1 when the corresponding individual interrupt
enable bit is cleared (set to 0), regardless of whether the limits are violated during a measurement.
2. If the individual enable bit is cleared while the associated status bit is 1, the status bit will be
cleared when the associated reading register is updated. The reading registers only get updated
when the START bit is set to ‘1’. If the enable bit is cleared when the START bit is 0, the associated
interrupt status bit will not be cleared until the start bit is set to 1 and the associated reading register
is updated.
Table 8.16 Interrupt Status Register 2
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
+12v_Error
R
0
The EMC6D103S automatically sets this bit to 1 when the 12V input
voltage is less than or equal to the limit set in the 12V Low Limit register
or greater than the limit set in the 12V High Limit register.
1
Reserved
R
0
Reserved
2
TACH1
Slow/Stalled
R
0
The EMC6D103S automatically sets this bit to 1 when the TACH1 input
reading is above the value set in the Tach1 Minimum MSB and LSB
registers.
3
TACH2
Slow/Stalled
R
0
The EMC6D103S automatically sets this bit to 1 when the TACH2 input
reading is above the value set in the Tach2 Minimum MSB and LSB
registers.
4
TACH3
Slow/Stalled
R
0
The EMC6D103S automatically sets this bit to 1 when the TACH3 input
reading is above the value set in the Tach3 Minimum MSB and LSB
registers.
5
TACH4
Slow/Stalled
R
0
The EMC6D103S automatically sets this bit to 1 when the TACH4 input
reading is above the value set in the Tach4 Minimum MSB and LSB
registers.
6
Remote
Diode 1 Fault
R
0
The EMC6D103S automatically sets this bit to 1 when there is either a
short or open circuit fault on the Remote1+ or Remote1- thermal diode
input pins as defined in the section Diode Fault on page 25.
Note:
7
Remote
Diode 2 Fault
R
0
The EMC6D103S automatically sets this bit to 1 when there is either a
short or open circuit fault on the Remote2+ or Remote2- thermal diode
input pins as defined in the section Diode Fault on page 25.
Note:
8.2.10
If the START bit is set and a fault condition exists, the Remote
Diode 1 reading register will be forced to 80h.
If the START bit is set and a fault condition exists, the Remote
Diode 2 reading register will be forced to 80h.
Register 43h: VID
Table 8.17 Register 43h: VID
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
43h
R
VID0-4
RES
RES
RES
VID4
VID3
VID2
VID1
VID0
N/A
The VID register contains the values of EMC6D103S VID0-VID4 input pins. This register indicates the
status of the VID lines that interconnect the processor to the Voltage Regulator Module (VRM).
SMSC EMC6D103S
59
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Software uses the information in this register to determine the voltage that the processor is designed
to operate at. With this information, software can then dynamically determine the correct values to
place in the Vccp Low Limit and Vccp High Limit registers.
This register is read only – a write to this register has no effect.
8.2.11
Registers 44-4Dh: Voltage Limit Registers
Table 8.18 Registers 44-4Dh: Voltage Limit Registers
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
44h
45h
46h
47h
48h
49h
4Ah
4Bh
4Ch
4Dh
Default
Value
R/W
2.5V Low Limit
7
6
5
4
3
2
1
0
00h
R/W
2.5V High Limit
7
6
5
4
3
2
1
0
FFh
R/W
Vccp Low Limit
7
6
5
4
3
2
1
0
00h
R/W
Vccp High Limit
7
6
5
4
3
2
1
0
FFh
R/W
VCC Low Limit
7
6
5
4
3
2
1
0
00h
R/W
VCC High Limit
7
6
5
4
3
2
1
0
FFh
R/W
5V Low Limit
7
6
5
4
3
2
1
0
00h
R/W
5V High Limit
7
6
5
4
3
2
1
0
FFh
R/W
12V Low Limit
7
6
5
4
3
2
1
0
00h
R/W
12V High Limit
7
6
5
4
3
2
1
0
FFh
Setting the Lock bit has no effect on these registers.
If a voltage input either exceeds the value set in the voltage high limit register or falls below or equals
the value set in the voltage low limit register, the corresponding bit will be set automatically by the
EMC6D103S in the interrupt status registers (41-42h). Voltages are presented in the registers at ¾ full
scale for the nominal voltage, meaning that at nominal voltage, each input will be C0h, as shown in
Table 8.19.
Table 8.19 Voltage Limits vs. Register Setting
NOMINAL
INPUT VOLTAGE
REGISTER
SETTING AT
NOMINAL
VOLTAGE
MAXIMUM
VOLTAGE
REGISTER
SETTING AT
MAXIMUM
VOLTAGE
REGISTER
SETTING AT
MINIMUM
VOLTAGE MINIMUM VOLTAGE
2.5V
2.5V
C0h
3.32V
FFh
0V
00h
Vccp
2.25V
C0h
3.00V
FFh
0V
00h
VCC
3.3V
C0h
4.38V
FFh
0V
00h
5V
5.0V
C0h
6.64V
FFh
0V
00h
12V
12.0V
C0h
16.00V
FFh
0V
00h
8.2.12
Registers 4E-53h: Temperature Limit Registers
Table 8.20 Registers 4E-53h: Temperature Limit Registers
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
4Eh
R/W
Remote Diode 1 Low Temp
7
6
5
4
3
2
1
0
81h
4Fh
R/W
Remote Diode 1 High Temp
7
6
5
4
3
2
1
0
7Fh
50h
R/W
Internal Low Temp
7
6
5
4
3
2
1
0
81h
Revision 0.2 (06-14-06)
60
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.20 Registers 4E-53h: Temperature Limit Registers (continued)
51h
R/W
Internal High Temp
7
6
5
4
3
2
1
0
7Fh
52h
R/W
Remote Diode 2 Low Temp
7
6
5
4
3
2
1
0
81h
53h
R/W
Remote Diode 2 High Temp
7
6
5
4
3
2
1
0
7Fh
Setting the Lock bit has no effect on these registers.
If an external temperature input or the internal temperature sensor either exceeds the value set in the
high limit register or is less than or equal to the value set in the low limit register, the corresponding
bit will be set automatically by the EMC6D103S in the Interrupt Status Register 1 (41h). For example,
if the temperature reading from the Remote1- and Remote1+ inputs exceeds the Remote Diode 1 High
Temp register limit setting, Bit[4] D1 of the Interrupt Status Register 1 will be set. The temperature limits
in these registers are represented as 8 bit, 2’s complement, signed numbers in Celsius, as shown
below in Table 8.21.
Table 8.21 Temperature Limits vs. Register Settings
8.2.13
TEMPERATURE
LIMIT (DEC)
LIMIT (HEX)
-127°c
-127
81h
.
.
.
.
.
.
.
.
.
-50°c
-50
CEh
.
.
.
.
.
.
.
.
.
0°c
0
00h
.
.
.
.
.
.
.
.
.
50°c
50
32h
.
.
.
.
.
.
.
.
.
127°c
127
7Fh
Registers 54-5Bh: Fan Tachometer Low Limit
Table 8.22 Registers 54-5Bh: Fan Tachometer Low Limit
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
54h
R/W
Tach1 Minimum LSB
7
6
5
4
3
2
1
0
FFh
55h
R/W
Tach1 Minimum MSB
15
14
13
12
11
10
9
8
FFh
56h
R/W
Tach2 Minimum LSB
7
6
5
4
3
2
1
0
FFh
57h
R/W
Tach2 Minimum MSB
15
14
13
12
11
10
9
8
FFh
58h
R/W
Tach3 Minimum LSB
7
6
5
4
3
2
1
0
FFh
59h
R/W
Tach3 Minimum MSB
15
14
13
12
11
10
9
8
FFh
5Ah
R/W
Tach4 Minimum LSB
7
6
5
4
3
2
1
0
FFh
5Bh
R/W
Tach4 Minimum MSB
15
14
13
12
11
10
9
8
FFh
SMSC EMC6D103S
61
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Setting the Lock bit has no effect on these registers.
The Fan Tachometer Low Limit registers indicate the tachometer reading that, if exceeded, the
corresponding bit will be set in the Interrupt Status Register 2 register. This register represents a
number of clock counts between the programmed number of tach edges and therefore as the number
increases, the effective RPM that it represents will decrease. The limit represents a fixed fan speed
(though the TACH measurement options may limit fan speeds that can be measured). See
Section 8.2.3 for a description of the TACH data formatting.
In Auto Fan Control mode, the fan can run at high speeds (100% duty cycle), so care should be taken
in software to ensure that the limit is low enough not to cause sporadic alerts. Note that an interrupt
status event will be generated when the tachometer reading is greater than the minimum tachometer
limit.
The fan tachometer will not cause a bit to be set in the interrupt status register if the current value in
the associated Current PWM Duty registers is 00h or if the PWM is disabled via the PWM
Configuration Register.
Interrupts will never be generated for a fan if its tachometer minimum is set to FFFFh.
8.2.14
Registers 5C-5Eh: PWM Configuration
Table 8.23 Registers 5C-5Eh: PWM Configuration
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
5Ch
R/W
PWM 1 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
5Dh
R/W
PWM 2 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
5Eh
R/W
PWM 3 Configuration
ZON2
ZON1
ZON0
INV
RES
SPIN2
SPIN1
SPIN0
62h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
Bits [7:5] Zone/Mode
Bits [7:5] of the PWM Configuration registers associate each PWM with a temperature sensor.
„
When in Auto Fan Mode, the PWM will be assigned to a zone, and its PWM duty cycle will be
adjusted according to the temperature of that zone. If ‘Hottest’ option is selected (101 or 110), the
PWM will be controlled by the hottest of zones 2 and 3, or of zones 1, 2, and 3. If one of these
options is selected, the PWM is controlled by the limits and parameters for the zone that requires
the highest PWM duty cycle, as computed by the auto fan algorithm.
„
When in manual control mode, the PWMx Current Duty Cycle Registers (30h-32h) become
Read/Write. It is then possible to control the PWM outputs with software by writing to these
registers. See PWMx Current Duty Cycle Registers description.
„
When the fan is disabled (100) the corresponding PWM output is driven low (or high, if inverted).
„
When the fan is Full On (011) the corresponding PWM output is driven high (or low, if inverted).
Notes:
„
Zone 1 is controlled by Remote Diode 1 Temp Reading register
„
Zone 2 is controlled by Internal Temp Reading Register
„
Zone 3 is controlled by Remote Diode 2 Temp Reading register
Revision 0.2 (06-14-06)
62
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.24 Fan Zone Setting
ZON[7:5]
PWM CONFIGURATION
000
Fan on zone 1 auto
001
Fan on zone 2 auto
010
Fan on zone 3 auto
011
Fan always on full
100
Fan disabled
101
Fan controlled by hottest of zones 2,3
110
Fan controlled by hottest of zones 1,2,3
111
Fan manually controlled
Bit [4] PWM Invert
Bit [4] inverts the PWM output. If set to 1, 100% duty cycle will yield an output that is low for 255 clocks
and high for 1 clock. If set to 0, 100% duty cycle will yield an output that is high for 255 clocks and
low for 1 clock.
Bit [3] Reserved
Bits [2:0] Spin Up
Bits [2:0] specify the ‘spin up’ time for the fan. When a fan is being started from a stationary state, the
PWM output is held at 100% duty cycle for the time specified in Table 8.25, "Fan Spin-Up Register"
before scaling to a lower speed. Note: during spin-up, the PWM pin is forced high for the duration of
the spin-up time (i.e., 100% duty cycle = 256/256).
Note: To reduce the spin-up time, this device has implemented a feature referred to as Spin Up
Reduction. Spin Up Reduction uses feedback from the tachometers to determine when each
fan has started spinning properly. Spin up for a PWM will end when the tachometer reading
register is below the minimum limit, or the spin-up time expires, whichever comes first. All tachs
associated with a PWM must be below min. for spin-up to end prematurely. This feature can
be disabled by clearing bit 4 (SUREN) of the Configuration register (7Fh). If disabled, the all
fans go on full for the duration of their associated spin up time. Note that the Tachx minimum
registers must be programmed to a value less than FFFFh in order for the spin-up reduction
to work properly.
Table 8.25 Fan Spin-Up Register
SMSC EMC6D103S
SPIN[2:0]
SPIN UP TIME
000
0 sec
001
100ms
010
250ms (default)
011
400ms
100
700ms
101
1000ms
110
2000ms
111
4000ms
63
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.15
Registers 5F-61h: Zone Temperature Range, PWM Frequency
Table 8.26 Registers 5F-61h: Zone Temperature Range, PWM Frequency
Register
Address
Read/
Write
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
5Fh
R/W
Zone 1 Range / Fan 1
Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
60h
R/W
Zone 2 Range / Fan 2
Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
61h
R/W
Zone 3 Range / Fan 3
Frequency
RAN3
RAN2
RAN1
RAN0
FRQ3
FRQ2
FRQ1
FRQ0
C3h
Register Name
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
In Auto Fan Mode, when the temperature for a zone is above the Low Temperature Limit (registers
67-69h) and below the Absolute Temperature Limit (registers 6A-6Ch) the speed of a fan assigned to
that zone is determined as follows by the auto fan control logic.
When the temperature reaches the temperature value programmed in the Zone x Low Temp Limit
register, the PWM output assigned to that zone is at PWMx Minimum Duty Cycle. Between Zone x
Low Temp Limit and (Zone x Low Temp Limit + Zone x Range), the PWM duty cycle increases linearly
according to the temperature as shown in the figure below.
PWM Duty is linear
this range
Below Fan Temp Limit: Fan at Fan PWM
Minimum
Temperature
Temperature Low LIMIT:
output at MIN FAN
Low LIMIT+ RANGE:
Output at 100% Duty
Figure 8.11 Fan Activity Above Low Temp Limit
Example for PWM1 assigned to Zone 1:
„
Zone 1 Low Temp Limit (Register 67h) is set to 50°C (32h).
„
Zone 1 Range (Register 5Fh) is set to 8°C (7h)
„
PWM1 Minimum Duty Cycle (Register 64h) is set to 50% (80h)
In this case, the PWM1 duty cycle will be 50% at 50°C.
Since (Zone 1 Low Temp Limit) + (Zone 1 Range) = 50°C + 8°C = 58°C, the fan controlled by PWM1
will run at 100% duty cycle when the temperature of the Zone 1 sensor is at 58°C.
Since the midpoint of the fan control range is 54°C, and the median duty cycle is 75% (Halfway
between the PWM Minimum and 100%), PWM1 duty cycle would be 75% at 54°C.
Above (Zone 1 Low Temp Limit) + (Zone 1 Range), the duty cycle must be 100%.
Revision 0.2 (06-14-06)
64
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
The PWM frequency bits [3:0] determine the PWM frequency for the fan.
PWM Frequency Selection (Default =0011=29.3Hz)
Table 8.27 Register Setting vs. PWM Frequency
FREQ[3:0]
PWM FREQUENCY
0000
11.0 Hz
0001
14.6 Hz
0010
21.9 Hz
0011
29.3 Hz (default)
0100
35.2 Hz
0101
44.0 Hz
0110
58.6 Hz
0111
87.7 Hz
1000 - 1001
N/A
1010
~25 Khz
1011 - 1111
N/A
Range Selection (Default =1100=32°C)
Table 8.28 Register Setting vs. Temperature Range
RANGE (°C)
RAN[3:0]
0000
2
0001
2.5
0010
3.33
0011
4
0100
5
0101
6.67
0110
8
0111
10
1000
13.33
1001
16
1010
20
1011
26.67
1100
32
1101
40
1110
53.33
1111
80
Note: The range numbers will be used to calculate the slope of the PWM ramp up. For the fractional
entries, the PWM will go on full when the temp reaches the next integer value e.g., for 3.33,
PWM will be full on at (min. temp + 4).
SMSC EMC6D103S
65
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.16
Register 62h, 63h: PWM Ramp Rate Control
Table 8.29 Register 62h, 63h: Min/Off, PWM Ramp Rate Control
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
62h
R/W
PWM 1 Ramp Rate Control
RES
RES
RES
RES
RR1E
RR1-2
RR1-1
RR1-0
E0h
63h
R/W
PWM 2, PWM 3 Ramp
Rate Control
RR2E
RR2-2
RR2-1
RR2-0
RR3E
RR3-2
RR3-1
RR3-0
00h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
The duty cycle will be set to the Minimum Fan Duty Cycle when the measured temperature falls below
the Temperature LIMIT register setting for the corresponding PWM.
Description of Ramp Rate Control bits:
If the Remote1 or Remote2 pins are connected to a processor or chipset, instantaneous temperature
spikes may be sampled by the part. The auto fan control logic calculates the PWM duty cycle for all
temperature readings. If Ramp Rate Control is disabled, the PWM output will jump or oscillate
between different PWM duty cycles causing the fan to suddenly change speeds, which creates
unwanted fan noise. If enabled, the PWM Ramp Rate Control logic will prevent the PWM output from
jumping, instead the PWM will ramp up/down towards the new duty cycle at a pre-determined ramp
rate.
Ramp Rate Control
The Ramp Rate Control logic limits the amount of change to the PWM duty cycle over a period of time.
This period of time is programmable via the Ramp Rate Control bits. For a detailed description of the
Ramp Rate Control bits see Table 8.30. For a description of the Ramp Rate Control logic see Ramp
Rate Control Logic on page 37.
Note:
„
RR1E, RR2E, and RR3E enable PWM Ramp Rate Control for PWM 1, 2, and 3 respectively.
„
RR1-2, RR1-1, and RR1-0 control ramp rate time for PWM 1
„
RR2-2, RR2-1, and RR2-0 control ramp rate time for PWM 2
„
RR3-2, RR3-1, and RR3-0 control ramp rate time for PWM 3
Table 8.30 PWM Ramp Rate Control
RRX-[2:0]
PWM RAMP TIME
(SEC)
(TIME FROM 33%
DUTY CYCLE TO
100% DUTY CYCLE)
PWM RAMP TIME
(SEC)
(TIME FROM 0%
DUTY CYCLE TO
100% DUTY CYCLE)
TIME PER PWM STEP
(PWM STEP SIZE =
1/255)
PWM
RAMP RATE
(HZ)
000
35
52.53
206 msec
4.85
001
17.6
26.52
104 msec
9.62
010
11.8
17.595
69 msec
14.49
011
7.0
10.455
41 msec
24.39
100
4.4
6.63
26 msec
38.46
101
3.0
4.59
18 msec
55.56
Revision 0.2 (06-14-06)
66
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.30 PWM Ramp Rate Control (continued)
RRX-[2:0]
PWM RAMP TIME
(SEC)
(TIME FROM 33%
DUTY CYCLE TO
100% DUTY CYCLE)
PWM RAMP TIME
(SEC)
(TIME FROM 0%
DUTY CYCLE TO
100% DUTY CYCLE)
TIME PER PWM STEP
(PWM STEP SIZE =
1/255)
PWM
RAMP RATE
(HZ)
110
1.6
2.55
10 msec
100
111
0.8
1.275
5 msec
200
8.2.17
Registers 64-66h: Minimum PWM Duty Cycle
Table 8.31 Registers 64-66h: Minimum PWM Duty Cycle
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
64h
R/W
PWM1 Minimum Duty Cycle
7
6
5
4
3
2
1
0
80h
65h
R/W
PWM2 Minimum Duty Cycle
7
6
5
4
3
2
1
0
80h
66h
R/W
PWM3 Minimum Duty Cycle
7
6
5
4
3
2
1
0
80h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
These registers specify the minimum duty cycle that the PWM will output when the measured
temperature reaches the Temperature LIMIT register setting in Auto Fan Control Mode.
Table 8.32 PWM Duty vs. Register Setting
MINIMUM PWM DUTY
VALUE (DECIMAL)
VALUE (HEX)
0%
0
00h
.
.
.
.
.
.
.
.
.
25%
64
40h
.
.
.
.
.
.
.
.
.
50%
128
80h
.
.
.
.
.
.
.
.
.
100%
255
FFh
8.2.18
Registers 67-69h: Zone Low Temperature Limit
Table 8.33 Registers 67-69h: Zone Low Temperature Limit
Register
Address
Read/
Write
SMSC EMC6D103S
Register Name
Bit 7
(MSb)
Bit 6
67
Bit 5
DATASHEET
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.33 Registers 67-69h: Zone Low Temperature Limit
67h
R/W
Zone 1 Low Temp Limit
7
6
5
4
3
2
1
0
80h
68h
R/W
Zone 2 Low Temp Limit
7
6
5
4
3
2
1
0
80h
69h
R/W
Zone 3 Low Temp Limit
7
6
5
4
3
2
1
0
80h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
These are the temperature limits for the individual zones. When the current temperature equals this
limit, the fan will be turned on if the Minimum PWM is set to 00h. When the temperature exceeds this
limit, the fan speed will be increased according to the auto fan algorithm based on the setting in the
Zone x Range / PWMx Frequency register. Default = -127°C=80h
APPLICATION NOTE: All three Zone Low Temperature Limit registers must be programmed to a valid value (other
than 80h) to allow the AutoFan control to operate.
Table 8.34 Temperature Limit vs. Register Setting
8.2.19
LIMIT
LIMIT (DEC)
LIMIT (HEX)
-127°c
-127
81h
.
.
.
.
.
.
.
.
.
-50°c
-50
CEh
.
.
.
.
.
.
.
.
.
0°c
0
00h
.
.
.
.
.
.
.
.
.
50°c
50
32h
.
.
.
.
.
.
.
.
.
127°c
127
7Fh
Registers 6A-6Ch: Absolute Temperature Limit
Table 8.35 Registers 6A-6Ch: Absolute Temperature Limit
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
6Ah
R/W
Zone 1 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
6Bh
R/W
Zone 2 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
6Ch
R/W
Zone 3 Temp Absolute Limit
7
6
5
4
3
2
1
0
64h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
In Auto Fan mode, if any zone associated with a PWM output exceeds the temperature set in the
Absolute limit register, all PWM outputs will increase their duty cycle to 100% except those that are
Revision 0.2 (06-14-06)
68
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
disabled via the PWM Configuration registers. This is a safety feature that attempts to cool the system
if there is a potentially catastrophic thermal event.
If an absolute limit register set to 80h (-128°c), the safety feature is disabled for the associated zone.
That is, if 80h is written into the Zone x Temp Absolute Limit Register, then regardless of the reading
register for the zone, the fans will not turn on-full based on the absolute temp condition.
Default =100°C=64h.
When any fan is in auto fan mode, then if the temperature in any zone exceeds absolute limit, all fans
go to full, including any in manual mode, except those that are disabled. Therefore, even if a zone is
not associated with a fan, if that zone exceeds absolute, then all fans go to full. In this case, the
absolute limit can be chosen to be 7Fh for those zones that are not associated with a fan, so that the
fans won't turn on unless the temperature hits 127 degrees.
Table 8.36 Absolute Limit vs. Register Setting
8.2.20
ABSOLUTE LIMIT
ABS LIMIT (DEC)
ABS LIMIT (HEX)
-127°c
-127
81h
.
.
.
.
.
.
.
.
.
-50°c
-50
CEh
.
.
.
.
.
.
.
.
.
0°c
0
00h
.
.
.
.
.
.
.
.
.
50°c
50
32h
.
.
.
.
.
.
.
.
.
127°c
127
7Fh
Register 6F: XOR Test Register
Table 8.37 Register 6F: XOR Test Register
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
6Fh
R/W
XOR Test Register
RES
RES
RES
RES
RES
RES
RES
XEN
00h
This register becomes read only when the Lock bit is set. Any further attempts to write to this register
shall have no effect.
The part incorporates an XOR tree test mode. When the test mode is enabled by setting the ‘XEN’ bit
high via SMBus, the part enters XOR test mode.
The following signals are included in the XOR test tree:
„
TACH1, TACH2, TACH3, TACH4
„
PWM2, PWM3
Since the test mode is XOR tree, the order of the signals in the tree is not important. SDA and SCL
are not included in the test tree.
SMSC EMC6D103S
69
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.21
Register 7Ch: Special Function Register
Table 8.38 Register 7Ch: Special Function Register
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
7Ch
R/W
Special Function
AVG2
AVG1
AVG0
SMSC
SMSC
INTEN
MONMD
LPMD
40h
This register becomes read only when the Lock bit is set. Any further attempts to write to this register
shall have no effect.
This register contains the following bits:
Table 8.39 Special Function Register
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
LPMD
R/W
0
Low Power Mode Select.
„ ‘0’ = Sleep Mode
„ ‘1’ = Low Power Mode
1
MONMD
R/W
0
Monitoring Mode Select.
„ ‘0’ = Continuous Mode
„ ‘1’ = Cycle Mode
2
INTEN
R/W
0
Global Interrupt enable. When set enables the INT# pin output function.
3
SMSC
R/W
0
SMSC - writing this bit may have undesired affects.
4
SMSC
R/W
0
SMSC - writing this bit may have undesired affects.
5
AVG0
R/W
0
6
AVG1
R/W
1
7
AVG2
R/W
0
The AVG[2:0] bits determine the amount of averaging for each of the six
measurements that are performed by the hardware monitor before the
reading registers are updated (Table 8.40, "AVG[2:0] Bit Decoder"). The
AVG[2:0] bits are priority encoded where the most significant bit has
highest priority. For example, when the AVG2 bit is asserted, 32 averages
will be performed for each measurement before the reading registers are
updated regardless of the state of the AVG[1:0] bits.
Note:
.
The default for the AVG[2:0] bits is ‘010’b
Table 8.40 AVG[2:0] Bit Decoder
SFTR[7:5]
AVERAGES PER READING
AVG2
AVG1
AVG0
REM DIODE 1
REM DIODE 2
INTERNAL DIODE
ALL VOLTAGE
READINGS
(+2.5V, +5V, +12V,
VCCP, AND VCC)
0
0
0
128
128
8
8
0
0
1
16
16
1
1
0
1
X
16
16
16
16
1
X
X
32
32
32
32
Revision 0.2 (06-14-06)
70
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.22
Register 7Eh: Interrupt Enable 1 Register
Table 8.41 Register 7Eh: Interrupt Enable 1 Register
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
7Eh
R/W
Interrupt Enable 1 (Voltages)
VCC
12V
5V
RES
VCCP
25V
RES
VOLT
ECh
This register becomes read only when the Lock bit is set. Any further attempts to write to this register
shall have no effect.
This register is used to enable individual voltage error events to set the corresponding status bits in
the interrupt status registers. This register also contains the group voltage enable bit (Bit[0] VOLT),
which is used to enable voltage events to force the interrupt pin (INT#) low if interrupts are enabled
(see Bit[2] INTEN of the Special Function register at offset 7Ch).
See Figure 6.3 Interrupt Control on page 25.
This register contains the following bits:
Table 8.42 Interrupt Enable 1 Register bits
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
VOLT
R/W
0
Group INT# Voltage Enable - when set, enables out-of-limit voltages to
drive the INT# pin low (provided that the INTEN bit in the Special Function
register is also set).
1
Reserved
R/W
0
Reserved
2
25V
R/W
1
When set, enables 2.5V Channel to update status registers and generate
interrupts
3
VCCP
R/W
1
When set Enables VCCP Channel to update status registers and
generate interrupts
4
Reserved
R/W
0
Reserved
5
5V
R/W
1
When set, enables 5V Channel to update status registers and generate
interrupts
6
12V
R/W
1
When set, enables 12V Channel to update status registers and generate
interrupts
7
VCC
R/W
1
When set, enables VCC channel to update status registers and generate
interrupts.
8.2.23
Register 7Fh: Configuration Register
Table 8.43 Register 7Fh: Configuration Register
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
7Fh
R/W
Configuration
INIT
SMSC
SMSC
SUREN
TRDY
RES
P2INT
T3INT
10h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
SMSC EMC6D103S
71
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.44 Configuration Register Bits
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
T3INT
R/W
0
Determines functionality of the TACH3/INT# pin.
„ ‘0’ - TACH3 input
„ ‘1’- INT# output
1
P2INT
R/W
0
Determines the functionality of the PWM2/INT# pin.
„ ‘0’ - PWM2 output.
„ ‘1’ - INT# output.
2
Reserved
R/W
0
Reserved
3
TRDY
R
0
Temperature Reading Ready - indicates that the temperature reading
registers hold valid values.
4
SUREN
R/W
1
Spin-up reduction enable - when set, this bit enables the reduction of the
spin-up time based on feedback from all fan tachometers associated with
each PWM.
5
SMSC
R/W
0
SMSC - Writing to this bit to a value different from the default value may
cause unwanted results.
6
SMSC
R/W
0
SMSC - Writing this bit to a value different than the default value may
cause unwanted results.
7
INIT
R/W
0
Setting the INIT bit to ‘1’ performs a soft reset. This bit is self-clearing.
Soft Reset sets all the registers except the Reading Registers to their
default values.
This register contains the following bits:
8.2.24
Register 80h: Interrupt Enable 2 Register
Table 8.45 Register 80h: Interrupt Enable 2 Register
Register
Address
Read/
Write
80h
R/W
Register Name
Interrupt Enable 2 (Fan
Tachs)
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
RES
RES
RES
TACH4
TACH3
TACH2
TACH1
TACH
1Eh
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
This register is used to enable individual fan tach error events to set the corresponding status bits in
the interrupt status registers. This register also contains the group fan tach enable bit (Bit[0] TACH),
which is used to enable fan tach events to force the interrupt pin (INT#) low if interrupts are enabled
(see Bit[2] INTEN of the Special Function register at offset 7Ch).
See Figure 6.3 Interrupt Control on page 25.
This register contains the following bits:
Revision 0.2 (06-14-06)
72
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.46 Interrupt Enable 2 Register Bits
BIT
NAME
R/W
DEFAULT
0
TACH
R
0
Group TACH INT# enable- When set enables out-of-limit TACH
measurements assert the INT# pin.
1
TACH1
R
1
When set, enables the TACH1 tachometer to update status registers and
generate interrupts.
2
TACH2
R
1
When set, enables the TACH2 tachometer to update status registers and
generate interrupts.
3
TACH3
R
1
When set, enables the TACH3 tachometer to update status registers and
generate interrupts.
4
TACH4
R
1
When set, enables the TACH4 tachometer to update status registers and
generate interrupts.
5
RES
R/W
0
Reserved
6
RES
R/W
0
Reserved
7
RES
R/W
0
Reserved
8.2.25
DESCRIPTION
Register 81h: TACH_PWM Association Register
Table 8.47 Register 81h: TACH_PWM Association Register
Register
Address
Read/
Write
Register Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
81h
R/W
TACH_PWM Association
T4H
T4L
T3H
T3L
T2H
T2L
T1H
T1L
A4h
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
This register is used to associate a PWM with a tachometer input. This association is used by the fan
logic to determine when to prevent a bit from being set in the interrupt status registers.
The fan tachometer will not cause a bit to be set in the interrupt status register:
g. if the current value in Current PWM Duty registers is 00h or
h. if the fan is disabled via the Fan Configuration Register.
Note: A bit will never be set in the interrupt status for a fan if its tachometer minimum is set to FFFFh.
See bit definition below.
Table 8.48 TACH_PWM Association Register Bits
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
T1L
R/W
0
1
T1H
R/W
0
Determine which PWM outputs are associated with the TACH1 input. See
Table 8.49
2
T2L
R/W
1
3
T2H
R/W
0
4
T3L
R/W
0
5
T3H
R/W
1
6
T4L
R/W
0
7
T4H
R/W
1
SMSC EMC6D103S
Determine which PWM outputs are associated with the TACH2 input. See
Table 8.49
Determine which PWM outputs are associated with the TACH3 input. See
Table 8.49
Determine which PWM outputs are associated with the TACH4 input. See
Table 8.49
73
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.49 PWM Assignment Bit Combinations
Bits[1:0], Bits[3:2], Bits[5:4], Bits[7:6]
PWM Associated With Tachx
00
PWM1
01
PWM2
10
PWM3
11
Reserved
Notes:
8.2.26
„
Any PWM that has no TACH inputs associated with it must be configured to operate in Mode 1.
„
All TACH inputs must be associated with a PWM output. If the tach is not being driven by the
associated PWM output it should be configured to operate in Mode 1 and the associated TACH
interrupt must be disabled.
Register 82h: Interrupt Enable 3 Register
Table 8.50 Register 82h: Interrupt Enable 3 Register
Register
Address
Read/
Write
Register
Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
82h
R/W
Interrupt Enable 3 (Temp)
RES
RES
RES
RES
D2EN
D1EN
AMB
TEMP
0Eh
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
This register is used to enable individual thermal error events to set the corresponding status bits in
the interrupt status registers. This register also contains the group thermal enable bit (Bit[0] TEMP),
which is used to enable thermal events to force the interrupt pin (INT#) low if interrupts are enabled
(see Bit[2] INTEN of the Special Function register at offset 7Ch).
See Figure 6.3 Interrupt Control on page 25.
This register contains the following bits:
:
Table 8.51 Interrupt Enable 3 Register Bits
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
TEMP
R/W
0
Group Temperature enable bit - when set, allows Temperature channels
to assert the INT# pin.
1
AMB
R/W
1
When set, enables the ambient temperature monitor to update the status
registers and generate interrupts.
2
D1EN
R/W
1
When set, enables the Remote Diode 1 temperature monitor to update
the status registers and generate interrupts.
3
D2EN
R/W
1
When set, enables the Remote Diode 2 temperature monitor to update
the status registers and generate interrupts.
4
RES
R/W
0
Reserved
5
RES
R/W
0
Reserved
6
RES
R/W
0
Reserved
7
RES
R/W
0
Reserved
Revision 0.2 (06-14-06)
74
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
8.2.27
Registers 85h-88h: A/D Converter LSbs Registers
Table 8.52 Registers 85h-88h: A/D Converter LSbs Registers
Register
Address
Read/
Write
Register
Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
85h
R
A/D Converter LSbs Reg 1
RD2.3
RD2.2
RD2.1
RD2.0
RD1.3
RD1.2
RD1.1
RD1.0
N/A
86h
R
A/D Converter LSbs Reg 2
V12.3
V12.2
V12.1
V12.0
AM.3
AM.2
AM.1
AM.0
N/A
87h
R
A/D Converter LSbs Reg 3
V50.3
V50.2
V50.1
V50.0
V25.3
V25.2
V25.1
V25.0
N/A
88h
R
A/D Converter LSbs Reg 4
VCC.3
VCC.2
VCC.1
VCC.0
VCP.3
VCP.2
VCP.1
VCP.0
N/A
There is a 10-bit Analog to Digital Converter (ADC) located in the hardware monitoring block that
converts the measured voltages into 10-bit reading values. Depending on the averaging scheme
enabled, the hardware monitor may take multiple readings and average them to create the values
stored in the reading registers (i.e., 16x averaging, 32x averaging, etc.) The 8 MSb’s of the reading
values are placed in the Reading Registers. When the upper 8-bits located in the reading registers
are read the 4 LSb’s are latched into their respective bits in the A/D Converter LSbs Register. This
give 12-bits of resolution with a minimum value of 1/16th per unit measured. (i.e., Temperature Range:
-127.9375 ºC < Temp < 127.9375 ºC and Voltage Range: 0 < Voltage < 256.9375) . See the DC
Characteristics for the accuracy of the reading values.
The eight most significant bits of the 12-bit averaged readings are stored in Reading registers and
compared with Limit registers. The Interrupt Status Register bits are asserted if the corresponding
measured value(s) on the inputs violate their programmed limits.
8.2.28
Registers 90h-93h: TachX Option Registers
Register
Address
Read/
Write
Register Name
90h
R/W
Tach1 Option
91h
R/W
92h
93h
Bit 7
(MSb)
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
RESERVED
3EDG
MODE
EDG1
EDG0
SLOW
04h
Tach2 Option
RESERVED
3EDG
MODE
EDG1
EDG0
SLOW
04h
R/W
Tach3 Option
RESERVED
3EDG
MODE
EDG1
EDG0
SLOW
04h
R/W
Tach4 Option
RESERVED
3EDG
MODE
EDG1
EDG0
SLOW
04h
Bit 6
Bit 5
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
SMSC EMC6D103S
75
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.53 TACH Option Register Bits
BIT
NAME
R/W
DEFAULT
0
SLOW
R/W
0
DESCRIPTION
„
„
‘0’ - Force TACH reading register to FFFEh
detected is greater than 0 but less than the
edges
‘1’ - Force TACH reading register to FFFFh
detected is greater than 0 but less than the
edges
if number of tach edges
programmed number of
if number of tach edges
programmed number of
1
EDG0
R/W
0
2
EDG1
R/W
1
Determines the number of edges necessary for a valid TACH reading.
„ 00 = 2 edges
„ 01 = 3 edges
„ 10 = 5 edges
„ 11 = 9 edges
3
MODE
R/W
0
Determines TACH reading mode
„ ‘0’ Mode 1 - standard operating mode
„ ‘1’ Mode 2 - only check measure TACH while PWM output is high.
4
3EDG
R/W
0
This bit is used when the TACH Mode is configured for Mode 2 only.
„ ‘0’ - don’t ignore 1st 3 TACH edges after PWM transitions from low to
high
„ ‘1’ - ignore first 3 edges after guard time
Note:
This bit has been added to support a small sampling of fans that
emit irregular tach pulses when the PWM transitions ‘ON’.
Typically, the guard time is sufficient for most fans.
5
RES
R/W
0
Reserved
6
RES
R/W
0
Reserved
7
RES
R/W
0
Reserved
8.2.29
Registers 94h-96h: PWMx Option Registers
Table 8.54 Registers 94h-96h: PWMx Option Registers
Register
Address
Read/
Write
Register
Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSb)
Default
Value
94h
R/W
PWM1 Option
RES
RES
OPP
GRD1
GRD0
SZEN
UPDT1
UPDT0
0Ch
95h
R/W
PWM2 Option
RES
RES
OPP
GRD1
GRD0
SZEN
UPDT1
UPDT0
0Ch
96h
R/W
PWM3 Option
RES
RES
OPP
GRD1
GRD0
SZEN
UPDT1
UPDT0
0Ch
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
Revision 0.2 (06-14-06)
76
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Table 8.55 PWM Option Register Bits
BIT
NAME
R/W
DEFAULT
DESCRIPTION
0
UPDT0
R/W
0
1
UPDT1
R/W
0
2
SZEN
R/W
1
Snap to Zero - determines if the PWM output ramps down to 00hor if is
immediately set to 00h when the input is set to 00h.
„ ‘0’ - Step down the PWM output to OFF at the programmed ramp rate.
„ ‘1’ - Transition PWM output to OFF immediately when the duty cycle is
set to 00h.
3
GRD0
R/W
1
4
GRD1
R/W
0
Sets the Guard time that the tachometer associated with this PWM driver
will wait after a transition from low to high before it begins measuring.
„ 00 = 63 clocks (90kHz clock ~ 700us)
„ 01 = 32 clocks (90kHz clock ~356us)
„ 10 = 16 clocks (90kHz clock ~178us)
„ 11 = 8 clocks (90kHz clock ~89us)
5
OPP
R/W
0
Opportunistic Mode enable - when set, enables opportunistic mode. The
tachometer reading is updated any time a valid tachometer reading can
be made. If a valid reading is detected prior to the update cycle, then the
update counter is reset.
6
RES
R/W
0
Reserved
7
RES
R/W
0
Reserved
Determines the update rate of tachometer circuits associated with this
PWM driver.
„ 00 - once a second
„ 01 - twice a second
„ 1x - every 300msec.
Table 8.56 PWM/TACH Test Register Bits
BIT
NAME
R/W
DEFAULT
0
glitch
R/W
1
is used to select the glitch suppression logic on the tachometer inputs
„ ‘0’ TACH inputs are synchronized to 90kHz oscillator.
„ ‘1’ TACH inputs are deglitched and synchronized to 90kHz oscillator
1
PSYNC1
R/W
0
2
PSYNC2
R/W
0
3
PSYNC3
R/W
0
Determine how each PWM outputs exit SpinUp.
„ ‘0’ - Exit Spinup Asynchronously to the PWM duty cycle. The first PWM
period when SpinUP is terminate may be a partial period.
„ ‘1’ - Exit Spinup at the beginning of the next PWM duty cycle period.
This option gets rid of the initial partial period created by exiting SpinUp,
but it extends the SpinUp time beyond the programmed limit.
4
ROVR
R/W
1
Determines the rollover value for mode 1 (all Tachs)
‘0’ 0080h - useful for simulation
‘1’ FFFFh
5
PWM1_256/
64
R/W
1
6
PWM2_256/
64
R/W
1
7
PWM3_256/
64
R/W
1
Scale the PWM duty cycle for the corresponding channel. When enabled,
will shift the PWM duty cycle down by 2 creating a duty cycle with a
resolution of 1/256. This allows the device to support higher PWM
frequencies
„ ‘0’= 64 count PWM duty cycle - resolution is 1/64
„ ‘1’ = 256 count PWM duty cycle
SMSC EMC6D103S
DESCRIPTION
77
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 9 Timing Diagrams
9.1
PWM Outputs
The following section shows the timing for the PWM[1:3] outputs.
t1
t2
FANx
Figure 9.1 PWMx Output Timing
Table 9.1 Timing for PWM[1:3] Outputs
NAME
DESCRIPTION
t1
PWM Period (Note 9.2)
t2
PWM High Time (Note 9.3)
MIN
TYP
MAX
UNITS
0.04
90.9
msec
0
99.6
%
Note 9.2
This value is programmable by the PWM frequency bits located in the FRFx registers.
Note 9.3
The PWM High Time is based on a percentage of the total PWM period (min=0/256*TPWM,
max =255/256*TPWM). During Spin-up the PWM High Time can reach a 100% or Full On.
(TPWM = t1).
Revision 0.2 (06-14-06)
78
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
9.2
SMBus Interface
tLOW
tR
tHD;STA
tF
SCLK
tHD;STA
tHD;DAT
tHIGH
tSU;DAT
tSU;STA
tSU;STO
SDA
tBUF
P
S
S
P
Figure 9.4 SMBus Timing
Table 9.2 SMBus Timing
LIMITS
SYMBOL
PARAMETER
MIN
10
MAX
UNITS
COMMENTS
400
kHz
Note 9.5
50
ns
Note 9.6
Fsmb
SMB Operating Frequency
Tsp
Spike Suppression
Tbuf
Bus free time between Stop and Start
Condition
1.3
μs
Thd:sta
Hold time after (Repeated) Start Condition.
After this period, the first clock is
generated.
0.6
μs
Tsu:sta
Repeated Start Condition setup time
0.6
μs
Tsu:sto
Stop Condition setup time
0.6
μs
Thd:dat
Data hold time
0.3
Tsu:dat
Data setup time
100
ns
Tlow
Clock low period
1.3
μs
Thigh
Clock high period
0.6
μs
Tf
Clock/Data Fall Time
20+0.1Cb
300
ns
Tr
Clock/Data Rise Time
20+0.1Cb
300
ns
Cb
Capacitive load for each bus line
400
pF
0.9
μs
Note 9.7
Note 9.5
The SMBus timing (e.g., max clock frequency of 400kHz) specified exceeds that specified
in the System Management Bus Specification, Rev 1.1. This corresponds to the maximum
clock frequency for fast mode devices on the I2C bus. See “The I2C Bus Specification,”
version 2.0, Dec. 1998.
Note 9.6
At 400kHz, spikes of a maximum pulse width of 50ns must be suppressed by the input
filter.
Note 9.7
If using 100 kHz clock frequency, the next data bit output to the SDA line will be 1250 ns
(1000 ns (TR max) + 250 ns (TSU:DAT min) @ 100 kHz) before the SCLK line is released.
SMSC EMC6D103S
79
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Chapter 10 Mechanical Specifications
Figure 10.1 24-Pin SSOP Package Outline, 0.150” Wide Body, 0.025” Pitch
Table 10.1 24-Pin SSOP Package Parameters
A
A1
A2
D
E
E1
H
L
e
è
W
ccc
MIN
NOMINAL
MAX
REMARKS
0.053
0.004
~
0.337
0.228
0.150
0.007
0.016
~
~
~
~
~
~
~
0.025
0.025 Basic
~
0.010
~
0.069
0.010
0.061
0.344
0.244
0.157
0.010
0.050
Overall Package Height
Standoff
Body Thickness
X Body Size
Y Span
Y body Size
Lead Frame Thickness
Lead Foot Length
Lead Pitch
Lead Foot Angle
Lead Width
Coplanarity
0o
0.008
~
8o
0.012
0.004
Notes:
1. Controlling Unit: inch.
2. Tolerance on the true position of the leads is ± 0.0035 inches maximum.
3. Package body dimensions D and E1 do not include the mold protrusion. Maximum mold protrusion
is 0.006 inches for ends, and 0.010 inches for sides.
4. Dimension for foot length L measured at the gauge plane 0.010 inches above the seating plane.
5. Details of pin 1 identifier are optional but must be located within the zone indicated.
Revision 0.2 (06-14-06)
80
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Appendix A ADC Voltage Conversion
Table A.1 Analog-to-Digital Voltage Conversions for Hardware Monitoring Block
INPUT VOLTAGE
A/D OUTPUT
12 VIN
5 VIN
VCC
2.5 VIN
VCCPIN
Decimal
Binary
<0.062
<0.026
<0.0172
<0.013
<0.012
0
0000 0000
0.062–0.125
0.026–0.052
0.017–0.034
0.013–0.026
0.012–0.023
1
0000 0001
0.125–0.188
0.052–0.078
0.034–0.052
0.026–0.039
0.023–0.035
2
0000 0010
0.188–0.250
0.078–0.104
0.052–0.069
0.039–0.052
0.035–0.047
3
0000 0011
0.250–0.313
0.104–0.130
0.069–0.086
0.052–0.065
0.047–0.058
4
0000 0100
0.313–0.375
0.130–0.156
0.086–0.103
0.065–0.078
0.058–0.070
5
0000 0101
0.375–0.438
0.156–0.182
0.103–0.120
0.078–0.091
0.070–0.082
6
0000 0110
0.438–0.500
0.182–0.208
0.120–0.138
0.091–0.104
0.082–0.093
7
0000 0111
0.500–0.563
0.208–0.234
0.138–0.155
0.104–0.117
0.093–0.105
8
0000 1000
…
…
…
…
…
…
…
4.000–4.063
1.666–1.692
1.100–1.117
0.833–0.846
0.749–0.761
64 (1/4 Scale)
0100 0000
…
…
…
…
…
…
…
8.000–8.063
3.330–3.560
2.200–2.217
1.667–1.680
1.499–1.511
128 (1/2 Scale)
1000 0000
…
…
…
…
…
…
…
12.000–12.063
5.000–5.026
3.300–3.317
2.500–2.513
2.249–2.261
192 (3/4 Scale)
1100 0000
…
…
…
…
…
…
…
15.312–15.375
6.380–6.406
4.210–4.230
3.190–3.203
2.869–2.881
245
1111 0101
15.375–15.437
6.406–6.432
4.230–4.245
3.203–3.216
2.881–2.893
246
1111 0110
15.437–15.500
6.432–6.458
4.245–4.263
3.216–3.229
2.893–2.905
247
1111 0111
15.500–15.563
6.458–6.484
4.263–4.280
3.229–3.242
2.905–2.916
248
1111 1000
15.625–15.625
6.484–6.510
4.280–4.300
3.242–3.255
2.916–2.928
249
1111 1001
15.625–15.688
6.510–6.536
4.300–4.314
3.255–3.268
2.928–2.940
250
1111 1010
15.688–15.750
6.536–6.562
4.314–4.330
3.268–3.281
2.940–2.951
251
1111 1011
15.750–15.812
6.562–6.588
4.331–4.348
3.281–3.294
2.951–2.964
252
1111 1100
15.812–15.875
6.588–6.615
4.348–4.366
3.294–3.307
2.964–2.975
253
1111 1101
15.875–15.938
6.615–6.640
4.366–4.383
3.307–3.320
2.975–2.987
254
1111 1110
>15.938
>6.640
>4.383
>3.320
>2.988
255
1111 1111
SMSC EMC6D103S
81
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Appendix B Example Fan Circuits
The following figures show examples of circuitry on the board for the PWM outputs, tachometer inputs,
and remote diodes. Figure B.1, "Fan Drive Circuitry (Apply to PWM Driving Two Fans)" shows how the
part can be used to control four fans by connecting two fans to one PWM output.
Note: These examples represent the minimum required components. Some designs may require
additional components.
3.3V
12
V
3.3V
1k
PWMx
2.2k
MMBT390
4
M
MMBT222
2
Fan
1
M
MMBT222
2
Fan
2
Figure B.1 Fan Drive Circuitry (Apply to PWM Driving Two Fans)
Revision 0.2 (06-14-06)
82
DATASHEET
SMSC EMC6D103S
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
3.3V
12V
Fan
470
M
PWMx
MMBT2222
Figure B.2 Fan Drive Circuitry (Apply to PWM Driving One Fan)
3.3V
10k
Tach
Output
from Fan
TACH
Input
D1
IN4148
Note: For fans controlled directly by a PW M , it is suggested to im plem ent
the optional diode (D1) to protect the tachom eter input from large voltage
spikes generated by the fan.
Figure B.3 Fan Tachometer Circuitry (Apply to Each Fan)
SMSC EMC6D103S
83
DATASHEET
Revision 0.2 (06-14-06)
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
Remote Diode +
External Temperature
Sensing Diode
(MMBT3904)
2.2nF
Remote Diode -
Figure B.4 Remote Diode (Apply to Remote2 Lines)
Notes:
1. 2.2nF cap is optional and should be placed close to the EMC6D103S if used.
2. The voltage at PWM3 must be at least 2.0V to avoid triggering Address Enable.
3. The Remote Diode + and Remote Diode - tracks should be kept close together, in parallel with
grounded guard tracks on each side. Using wide tracks will help to minimize inductance and reduce
noise pickup. A 10 mil track minimum width and spacing is recommended. See Figure B.5,
"Suggested Minimum Track Width and Spacing".
.
GND
D+
10 mil.
10 mil.
10 mil.
D-
10 mil.
10 mil.
GND
10 mil.
10 mil.
Figure B.5 Suggested Minimum Track Width and Spacing
Revision 0.2 (06-14-06)
84
DATASHEET
SMSC EMC6D103S