ALTERA EP20K200C

APEX 20KC
Programmable Logic
Device
®
February 2004 ver. 2.2
Features...
Data Sheet
■
■
Programmable logic device (PLD) manufactured using a 0.15-µm alllayer copper-metal fabrication process
–
25 to 35% faster design performance than APEXTM 20KE devices
–
Pin-compatible with APEX 20KE devices
–
High-performance, low-power copper interconnect
–
MultiCoreTM architecture integrating look-up table (LUT) logic
and embedded memory
–
LUT logic used for register-intensive functions
–
Embedded system blocks (ESBs) used to implement memory
functions, including first-in first-out (FIFO) buffers, dual-port
RAM, and content-addressable memory (CAM)
High-density architecture
–
200,000 to 1 million typical gates (see Table 1)
–
Up to 38,400 logic elements (LEs)
–
Up to 327,680 RAM bits that can be used without reducing
available logic
Table 1. APEX 20KC Device Features
Feature
Note (1)
EP20K200C
EP20K400C
EP20K600C
EP20K1000C
Maximum system gates
526,000
1,052,000
1,537,000
1,772,000
Typical gates
200,000
400,000
600,000
1,000,000
8,320
16,640
24,320
38,400
LEs
ESBs
Maximum RAM bits
PLLs (2)
52
104
152
160
106,496
212,992
311,296
327,680
2
4
4
4
-7, -8, -9
-7, -8, -9
-7, -8, -9
-7, -8, -9
Maximum macrocells
832
1,664
2,432
2,560
Maximum user I/O pins
376
488
588
708
Speed grades (3)
Notes to Table 1:
(1)
(2)
(3)
The embedded IEEE Std. 1149.1 Joint Test Action Group (JTAG) boundary-scan circuitry contributes up to
57,000 additional gates.
PLL: phase-locked loop.
The -7 speed grade provides the fastest performance.
Altera Corporation
DS-APEX20KC-2.2
1
APEX 20KC Programmable Logic Device Data Sheet
...and More
Features
■
■
■
Low-power operation design
–
1.8-V supply voltage (see Table 2)
–
Copper interconnect reduces power consumption
–
MultiVoltTM I/O support for 1.8-V, 2.5-V, and 3.3-V interfaces
–
ESBs offering programmable power-saving mode
Flexible clock management circuitry with up to four phase-locked
loops (PLLs)
–
Built-in low-skew clock tree
–
Up to eight global clock signals
–
ClockLockTM feature reducing clock delay and skew
–
ClockBoostTM feature providing clock multiplication and
division
–
ClockShiftTM feature providing programmable clock phase and
delay shifting
Powerful I/O features
–
Compliant with peripheral component interconnect Special
Interest Group (PCI SIG) PCI Local Bus Specification,
Revision 2.2 for 3.3-V operation at 33 or 66 MHz and 32 or 64 bits
–
Support for high-speed external memories, including DDR
synchronous dynamic RAM (SDRAM) and ZBT static RAM
(SRAM)
–
16 input and 16 output LVDS channels at 840 megabits per
second (Mbps)
–
Direct connection from I/O pins to local interconnect providing
fast tCO and tSU times for complex logic
–
MultiVolt I/O support for 1.8-V, 2.5-V, and 3.3-V interfaces
–
Programmable clamp to VCCIO
–
Individual tri-state output enable control for each pin
–
Programmable output slew-rate control to reduce switching
noise
–
Support for advanced I/O standards, including low-voltage
differential signaling (LVDS), LVPECL, PCI-X, AGP, CTT,
SSTL-3 and SSTL-2, GTL+, and HSTL Class I
–
Supports hot-socketing operation
–
Pull-up on I/O pins before and during configuration
Table 2. APEX 20KC Supply Voltages
Feature
Internal supply voltage (VCCINT)
Voltage
1.8 V
MultiVolt I/O interface voltage levels (VCCIO) 1.8 V, 2.5 V, 3.3 V, 5.0 V (1)
Note to Table 2:
(1)
2
APEX 20KC devices can be 5.0-V tolerant by using an external resistor.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
■
■
Advanced interconnect structure
–
Copper interconnect for high performance
–
Four-level hierarchical FastTrack® interconnect structure
providing fast, predictable interconnect delays
–
Dedicated carry chain that implements arithmetic functions such
as fast adders, counters, and comparators (automatically used by
software tools and megafunctions)
–
Dedicated cascade chain that implements high-speed,
high-fan-in logic functions (automatically used by software tools
and megafunctions)
–
Interleaved local interconnect allows one LE to drive 29 other
LEs through the fast local interconnect
Advanced software support
–
Software design support and automatic place-and-route
provided by the Altera® QuartusTM II development system for
Windows-based PCs, Sun SPARCstations, and HP 9000
Series 700/800 workstations
–
Altera MegaCore® functions and Altera Megafunction Partners
Program (AMPPSM) megafunctions optimized for APEX 20KC
architecture available
–
NativeLinkTM integration with popular synthesis, simulation,
and timing analysis tools
–
Quartus II SignalTap® embedded logic analyzer simplifies
in-system design evaluation by giving access to internal nodes
during device operation
–
Supports popular revision-control software packages including
PVCS, RCS, and SCCS
Table 3. APEX 20KC QFP & BGA Package Options & I/O Count
Device
EP20K200C
Altera Corporation
208-Pin PQFP 240-Pin PQFP
136
168
356-Pin BGA
Notes (1), (2)
652-Pin BGA
271
EP20K400C
488
EP20K600C
488
EP20K1000C
488
3
APEX 20KC Programmable Logic Device Data Sheet
Table 4. APEX 20KC FineLine BGA Package Options & I/O Count Notes (1), (2)
Device
484 Pin
EP20K200C
672 Pin
1,020 Pin
376
EP20K400C
488 (3)
EP20K600C
508 (3)
588
EP20K1000C
508 (3)
708
Notes to Tables 3 and 4:
(1)
(2)
(3)
I/O counts include dedicated input and clock pins.
APEX 20KC device package types include plastic quad flat pack (PQFP), 1.27-mm
pitch ball-grid array (BGA), and 1.00-mm pitch FineLine BGATM packages.
This device uses a thermally enhanced package, which is taller than the regular
package. Consult the Altera Device Package Information Data Sheet for detailed
package size information.
Table 5. APEX 20KC QFP & BGA Package Sizes
Feature
208-Pin PQFP
240-Pin PQFP
356-Pin BGA
652-Pin BGA
Pitch (mm)
0.50
0.50
1.27
1.27
Area (mm2)
924
1,218
1,225
2,025
30.4 × 30.4
34.9 × 34.9
35.0 × 35.0
45.0 × 45.0
Length × Width (mm × mm)
Table 6. APEX 20KC FineLine BGA Package Sizes
Feature
Pitch (mm)
2
Area (mm )
Length × Width (mm × mm)
General
Description
4
484 Pin
672 Pin
1,020 Pin
1.00
1.00
1.00
529
729
1,089
23 × 23
27 × 27
33 × 33
Similar to APEX 20K and APEX 20KE devices, APEX 20KC devices offer
the MultiCore architecture, which combines the strengths of LUT-based
and product-term-based devices with an enhanced memory structure.
LUT-based logic provides optimized performance and efficiency for datapath, register-intensive, mathematical, or digital signal processing (DSP)
designs. Product-term-based logic is optimized for complex
combinatorial paths, such as complex state machines. LUT- and productterm-based logic combined with memory functions and a wide variety of
MegaCore and AMPP functions make the APEX 20KC architecture
uniquely suited for SOPC designs. Applications historically requiring a
combination of LUT-, product-term-, and memory-based devices can now
be integrated into one APEX 20KC device.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
APEX 20KC devices include additional features such as enhanced I/O
standard support, CAM, additional global clocks, and enhanced
ClockLock clock circuitry. Table 7 shows the features included in
APEX 20KC devices.
Table 7. APEX 20KC Device Features (Part 1 of 2)
Feature
Altera Corporation
APEX 20KC Devices
MultiCore system integration
Full support
Hot-socketing support
Full support
SignalTap logic analysis
Full support
32-/64-bit, 33-MHz PCI
Full compliance
32-/64-bit, 66-MHz PCI
Full compliance in -7 and -8 speed grades in
selected devices
MultiVolt I/O
1.8-V, 2.5-V, or 3.3-V VCCIO
VCCIO selected bank by bank
5.0-V tolerant with use of external resistor
ClockLock support
Clock delay reduction
m /(n × v) clock multiplication
Drive ClockLock output off-chip
External clock feedback
ClockShift circuitry
LVDS support
Up to four PLLs
ClockShift clock phase adjustment
Dedicated clock and input pins
Eight
5
APEX 20KC Programmable Logic Device Data Sheet
Table 7. APEX 20KC Device Features (Part 2 of 2)
Feature
APEX 20KC Devices
I/O standard support
1.8-V, 2.5-V, 3.3-V, 5.0-V I/O
3.3-V PCI and PCI-X
3.3-V AGP
CTT
GTL+
LVCMOS
LVTTL
True-LVDSTM and LVPECL data pins (in
EP20K400C and larger devices)
LVDS and LVPECL clock pins (in all devices)
LVDS and LVPECL data pins up to 156 Mbps
(in EP20K200C devices)
HSTL Class I
PCI-X
SSTL-2 Class I and II
SSTL-3 Class I and II
Memory support
CAM
Dual-port RAM
FIFO
RAM
ROM
All APEX 20KC devices are reconfigurable and are 100% tested prior to
shipment. As a result, test vectors do not have to be generated for faultcoverage purposes. Instead, the designer can focus on simulation and
design verification. In addition, the designer does not need to manage
inventories of different application-specific integrated circuit (ASIC)
designs; APEX 20KC devices can be configured on the board for the
specific functionality required.
APEX 20KC devices are configured at system power-up with data stored
in an Altera serial configuration device or provided by a system
controller. Altera offers in-system programmability (ISP)-capable EPC16,
EPC8, EPC4, EPC2, and EPC1 configuration devices and one-time
programmable (OTP) EPC1 configuration devices, which configure
APEX 20KC devices via a serial data stream. Moreover, APEX 20KC
devices contain an optimized interface that permits microprocessors to
configure APEX 20KC devices serially or in parallel, and synchronously
or asynchronously. The interface also enables microprocessors to treat
APEX 20KC devices as memory and configure the device by writing to a
virtual memory location, making reconfiguration easy.
6
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
After an APEX 20KC device has been configured, it can be reconfigured
in-circuit by resetting the device and loading new data. Real-time changes
can be made during system operation, enabling innovative reconfigurable
computing applications.
APEX 20KC devices are supported by the Altera Quartus II development
system, a single, integrated package that offers HDL and schematic design
entry, compilation and logic synthesis, full simulation and worst-case
timing analysis, SignalTap logic analysis, and device configuration. The
Quartus II software runs on Windows-based PCs, Sun SPARCstations,
and HP 9000 Series 700/800 workstations.
The Quartus II software provides NativeLink interfaces to other industrystandard PC- and UNIX workstation-based EDA tools. For example,
designers can invoke the Quartus II software from within third-party
design tools. Further, the Quartus II software contains built-in optimized
synthesis libraries; synthesis tools can use these libraries to optimize
designs for APEX 20KC devices. For example, the Synopsys Design
Compiler library, supplied with the Quartus II development system,
includes DesignWare functions optimized for the APEX 20KC
architecture.
Functional
Description
APEX 20KC devices incorporate LUT-based logic, product-term-based
logic, and memory into one device on an all-copper technology process.
Signal interconnections within APEX 20KC devices (as well as to and from
device pins) are provided by the FastTrack interconnect—a series of fast,
continuous row and column channels that run the entire length and width
of the device.
Each I/O pin is fed by an I/O element (IOE) located at the end of each row
and column of the FastTrack interconnect. Each IOE contains a
bidirectional I/O buffer and a register that can be used as either an input
or output register to feed input, output, or bidirectional signals. When
used with a dedicated clock pin, these registers provide exceptional
performance. IOEs provide a variety of features, such as 3.3-V, 64-bit,
66-MHz PCI compliance; JTAG BST support; slew-rate control; and
tri-state buffers. APEX 20KC devices offer enhanced I/O support,
including support for 1.8-V I/O, 2.5-V I/O, LVCMOS, LVTTL, LVPECL,
3.3-V PCI, PCI-X, LVDS, GTL+, SSTL-2, SSTL-3, HSTL, CTT, and 3.3-V
AGP I/O standards.
Altera Corporation
7
APEX 20KC Programmable Logic Device Data Sheet
The ESB can implement a variety of memory functions, including CAM,
RAM, dual-port RAM, ROM, and FIFO functions. Embedding the
memory directly into the die improves performance and reduces die area
compared to distributed-RAM implementations. Moreover, the
abundance of cascadable ESBs allows APEX 20KC devices to implement
multiple wide memory blocks for high-density designs. The ESB’s high
speed ensures it can implement small memory blocks without any speed
penalty. Additionally, designers can use the ESBs to create as many
different-sized memory blocks as the system requires. Figure 1 shows an
overview of the APEX 20KC device.
Figure 1. APEX 20KC Device Block Diagram
Clock Management Circuitry
Four-input LUT
for data path and
DSP functions.
Product-term
integration for
high-speed
control logic and
state machines.
FastTrack
Interconnect
IOE
ClockLock
IOE
LUT
LUT
LUT
LUT
IOE
Product Term
Product Term
Product Term
Product Term
Memory
Memory
Memory
Memory
IOE
IOE
IOE
LUT
LUT
LUT
LUT
Product Term
Product Term
Product Term
Product Term
Memory
Memory
Memory
Memory
IOE
IOE
IOE
IOE
LUT
IOE
IOEs support
PCI, GTL+,
SSTL-3, LVDS,
and other
standards.
IOE
Flexible integration
of embedded
memory, including
CAM, RAM,
ROM, FIFO, and
other memory
functions.
APEX 20KC devices provide four dedicated clock pins and four dedicated
input pins that drive register control inputs. These signals ensure efficient
distribution of high-speed, low-skew control signals, which use dedicated
routing channels to provide short delays and low skews. Four of the
dedicated inputs drive four global signals. These four global signals can
also be driven by internal logic, providing an ideal solution for a clock
divider or internally generated asynchronous clear signals with high
fan-out. The dedicated clock pins featured on the APEX 20KC devices can
also feed logic. The devices also feature ClockLock and ClockBoost clock
management circuitry.
8
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
MegaLAB Structure
APEX 20KC devices are constructed from a series of MegaLABTM
structures. Each MegaLAB structure contains 16 logic array blocks (LABs),
one ESB, and a MegaLAB interconnect, which routes signals within the
MegaLAB structure. In EP20K1000C devices, MegaLAB structures
contain 24 LABs. Signals are routed between MegaLAB structures and
I/O pins via the FastTrack interconnect. In addition, edge LABs can be
driven by I/O pins through the local interconnect. Figure 2 shows the
MegaLAB structure.
Figure 2. MegaLAB Structure
MegaLAB Interconnect
To Adjacent
LAB or IOEs
LE1
LE2
LE3
LE4
LE5
LE6
LE7
LE8
LE9
LE10
Local
Interconnect
LE1
LE2
LE3
LE4
LE5
LE6
LE7
LE8
LE9
LE10
LE1
LE2
LE3
LE4
LE5
LE6
LE7
LE8
LE9
LE10
ESB
LABs
Logic Array Block
Each LAB consists of 10 LEs, the LEs’ associated carry and cascade chains,
LAB control signals, and the local interconnect. The local interconnect
transfers signals between LEs in the same or adjacent LABs, IOEs, or ESBs.
The Quartus II Compiler places associated logic within an LAB or adjacent
LABs, allowing the use of a fast local interconnect for high performance.
Figure 3 shows the APEX 20KC LAB.
APEX 20KC devices use an interleaved LAB structure. This structure
allows each LE to drive two local interconnect areas, minimizing the use
of the MegaLAB and FastTrack interconnect and providing higher
performance and flexibility. Each LE can drive 29 other LEs through the
fast local interconnect.
Altera Corporation
9
APEX 20KC Programmable Logic Device Data Sheet
Figure 3. LAB Structure
Row
Interconnect
MegaLAB Interconnect
LEs drive local,
MegaLAB, row,
and column
interconnects.
To/From
Adjacent LAB,
ESB, or IOEs
To/From
Adjacent LAB,
ESB, or IOEs
Local Interconnect
Column
Interconnect
The 10 LEs in the LAB are driven by
two local interconnect areas. These LEs
can drive two local interconnect areas.
Each LAB contains dedicated logic for driving control signals to its LEs
and ESBs. The control signals include clock, clock enable, asynchronous
clear, asynchronous preset, asynchronous load, synchronous clear, and
synchronous load signals. A maximum of six control signals can be used
at a time. Although synchronous load and clear signals are generally used
when implementing counters, they can also be used with other functions.
Each LAB can use two clocks and two clock enable signals. Each LAB’s
clock and clock enable signals are linked (e.g., any LE in a particular LAB
using CLK1 will also use CLKENA1). LEs with the same clock but different
clock enable signals either use both clock signals in one LAB or are placed
into separate LABs.
If both the rising and falling edges of a clock are used in a LAB, both LABwide clock signals are used.
10
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
The LAB-wide control signals can be generated from the LAB local
interconnect, global signals, and dedicated clock pins. The inherent low
skew of the FastTrack interconnect enables it to be used for clock
distribution. Figure 4 shows the LAB control signal generation circuit.
Figure 4. LAB Control Signal Generation
Dedicated
Clocks
4
Global
Signals
4
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
SYNCLOAD
or LABCLKENA2
SYNCCLR
or LABCLK2 (2)
LABCLKENA1
LABCLK1
LABCLR1 (1)
LABCLR2 (1)
Notes to Figure 4:
(1)
(2)
The LABCLR1 and LABCLR2 signals also control asynchronous load and asynchronous preset for LEs within the
LAB.
The SYNCCLR signal can be generated by the local interconnect or global signals.
Logic Element
The LE, the smallest unit of logic in the APEX 20KC architecture, is
compact and provides efficient logic usage. Each LE contains a four-input
LUT, which is a function generator that can quickly implement any
function of four variables. In addition, each LE contains a programmable
register and carry and cascade chains. Each LE drives the local
interconnect, MegaLAB interconnect, and FastTrack interconnect routing
structures. See Figure 5.
Altera Corporation
11
APEX 20KC Programmable Logic Device Data Sheet
Figure 5. APEX 20KC Logic Element
Register Bypass
Carry-In
data1
data2
data3
data4
Look-Up
Table
(LUT)
Carry
Chain
LAB-wide
LAB-wide
Synchronous Synchronous
Load
Clear
Cascade-In
Cascade
Chain
Synchronous
Load & Clear
Logic
Packed
Register Select
Programmable
Register
D
PRN
Q
To FastTrack Interconnect,
MegaLAB Interconnect,
or Local Interconnect
ENA
CLRN
To FastTrack Interconnect,
MegaLAB Interconnect,
or Local Interconnect
labclr1
labclr2
Chip-Wide
Reset
Asynchronous
Clear/Preset/
Load Logic
Clock & Clock
Enable Select
labclk1
labclk2
labclkena1
labclkena2
Carry-Out
Cascade-Out
Each LE’s programmable register can be configured for D, T, JK, or SR
operation. The register’s clock and clear control signals can be driven by
global signals, general-purpose I/O pins, or any internal logic. For
combinatorial functions, the register is bypassed and the output of the
LUT drives the outputs of the LE.
Each LE has two outputs that drive the local, MegaLAB, or FastTrack
interconnect routing structure. Each output can be driven independently
by the LUT’s or register’s output. For example, the LUT can drive one
output while the register drives the other output. This feature, called
register packing, improves device utilization because the register and the
LUT can be used for unrelated functions. The LE can also drive out
registered and unregistered versions of the LUT output.
12
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
The APEX 20KC architecture provides two types of dedicated high-speed
data paths that connect adjacent LEs without using local interconnect
paths: carry chains and cascade chains. A carry chain supports high-speed
arithmetic functions such as counters and adders, while a cascade chain
implements wide-input functions such as equality comparators with
minimum delay. Carry and cascade chains connect LEs 1 through 10 in an
LAB and all LABs in the same MegaLAB structure.
Carry Chain
The carry chain provides a very fast carry-forward function between LEs.
The carry-in signal from a lower-order bit drives forward into the higherorder bit via the carry chain, and feeds into both the LUT and the next
portion of the carry chain. This feature allows the APEX 20KC architecture
to implement high-speed counters, adders, and comparators of arbitrary
width. Carry chain logic can be created automatically by the Quartus II
Compiler during design processing, or manually by the designer during
design entry. Parameterized functions such as DesignWare functions
from Synopsys and library of parameterized modules (LPM) functions
automatically take advantage of carry chains for the appropriate
functions.
The Quartus II Compiler creates carry chains longer than ten LEs by
automatically linking LABs together. For enhanced fitting, a long carry
chain skips alternate LABs in a MegaLAB structure. A carry chain longer
than one LAB skips either from an even-numbered LAB to the next evennumbered LAB, or from an odd-numbered LAB to the next oddnumbered LAB. For example, the last LE of the first LAB in the upper-left
MegaLAB structure carries to the first LE of the third LAB in the
MegaLAB structure.
Figure 6 shows how an n-bit full adder can be implemented in n + 1 LEs
with the carry chain. One portion of the LUT generates the sum of two bits
using the input signals and the carry-in signal; the sum is routed to the
output of the LE. The register can be bypassed for simple adders or used
for accumulator functions. Another portion of the LUT and the carry chain
logic generates the carry-out signal, which is routed directly to the carryin signal of the next-higher-order bit. The final carry-out signal is routed
to an LE, where it is driven onto the local, MegaLAB, or FastTrack
interconnect routing structures.
Altera Corporation
13
APEX 20KC Programmable Logic Device Data Sheet
Figure 6. APEX 20KC Carry Chain
Carry-In
a1
b1
LUT
s1
Register
Carry Chain
LE1
a2
b2
LUT
s2
Register
Carry Chain
LE2
an
bn
LUT
sn
Register
Carry Chain
LEn
LUT
Register
Carry-Out
Carry Chain
LEn + 1
14
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Cascade Chain
With the cascade chain, the APEX 20KC architecture can implement
functions with a very wide fan-in. Adjacent LUTs can compute portions
of a function in parallel; the cascade chain serially connects the
intermediate values. The cascade chain can use a logical AND or logical OR
(via De Morgan’s inversion) to connect the outputs of adjacent LEs. Each
additional LE provides four more inputs to the effective width of a
function, with a short cascade delay. Cascade chain logic can be created
automatically by the Quartus II Compiler during design processing, or
manually by the designer during design entry.
Cascade chains longer than ten LEs are implemented automatically by
linking LABs together. For enhanced fitting, a long cascade chain skips
alternate LABs in a MegaLAB structure. A cascade chain longer than one
LAB skips either from an even-numbered LAB to the next even-numbered
LAB, or from an odd-numbered LAB to the next odd-numbered LAB. For
example, the last LE of the first LAB in the upper-left MegaLAB structure
carries to the first LE of the third LAB in the MegaLAB structure. Figure 7
shows how the cascade function can connect adjacent LEs to form
functions with a wide fan-in.
Figure 7. APEX 20KC Cascade Chain
AND Cascade Chain
d[3..0]
OR Cascade Chain
d[3..0]
LUT
LUT
LE1
d[7..4]
LE1
d[7..4]
LUT
LUT
LE2
d[(4n – 1)..(4n – 4)]
d[(4n – 1)..(4n – 4)]
LUT
LEn
Altera Corporation
LE2
LUT
LEn
15
APEX 20KC Programmable Logic Device Data Sheet
LE Operating Modes
The APEX 20KC LE can operate in one of the following three modes:
■
■
■
Normal mode
Arithmetic mode
Counter mode
Each mode uses LE resources differently. In each mode, seven available
inputs to the LE—the four data inputs from the LAB local interconnect,
the feedback from the programmable register, and the carry-in and
cascade-in from the previous LE—are directed to different destinations to
implement the desired logic function. LAB-wide signals provide clock,
asynchronous clear, asynchronous preset, asynchronous load,
synchronous clear, synchronous load, and clock enable control for the
register. These LAB-wide signals are available in all LE modes.
The Quartus II software, in conjunction with parameterized functions
such as LPM and DesignWare functions, automatically chooses the
appropriate mode for common functions such as counters, adders, and
multipliers. If required, the designer can also create special-purpose
functions that specify which LE operating mode to use for optimal
performance. Figure 8 shows the LE operating modes.
16
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 8. APEX 20KC LE Operating Modes
Normal Mode (1)
Carry-In (3)
LAB-Wide
Clock Enable (2)
Cascade-In
data1
data2
LE Out
4-Input
LUT
data3
D
PRN
Q
LE Out
data4
ENA
CLRN
Cascade-Out
Arithmetic Mode
Carry-In
LAB-Wide
Clock Enable (2)
Cascade-In
LE Out
data1
data2
PRN
D
Q
3-Input
LUT
LE Out
ENA
CLRN
3-Input
LUT
Carry-Out Cascade-Out
Counter Mode
LAB-Wide
Synchronous
Clear (6)
Cascade-In
Carry-In
LAB-Wide
Synchronous
Load (6)
LAB-Wide
Clock Enable (2)
(4)
data1 (5)
data2 (5)
LE Out
3-Input
LUT
D
PRN
Q
LE Out
data3 (data)
ENA
CLRN
3-Input
LUT
Carry-Out Cascade-Out
Notes to Figure 8:
(1)
(2)
(3)
(4)
(5)
(6)
LEs in normal mode support register packing.
There are two LAB-wide clock enables per LAB.
When using the carry-in in normal mode, the packed register feature is unavailable.
A register feedback multiplexer is available on LE1 of each LAB.
The DATA1 and DATA2 input signals can supply counter enable, up or down control, or register feedback signals for
LEs other than the second LE in an LAB.
The LAB-wide synchronous clear and LAB wide synchronous load affect all registers in an LAB.
Altera Corporation
17
APEX 20KC Programmable Logic Device Data Sheet
Normal Mode
The normal mode is suitable for general logic applications, combinatorial
functions, or wide decoding functions that can take advantage of a
cascade chain. In normal mode, four data inputs from the LAB local
interconnect and the carry-in are inputs to a four-input LUT. The
Quartus II Compiler automatically selects the carry-in or the DATA3 signal
as one of the inputs to the LUT. The LUT output can be combined with the
cascade-in signal to form a cascade chain through the cascade-out signal.
LEs in normal mode support packed registers.
Arithmetic Mode
The arithmetic mode is ideal for implementing adders, accumulators, and
comparators. An LE in arithmetic mode uses two 3-input LUTs. One LUT
computes a three-input function; the other generates a carry output. As
shown in Figure 8, the first LUT uses the carry-in signal and two data
inputs from the LAB local interconnect to generate a combinatorial or
registered output. For example, when implementing an adder, this output
is the sum of three signals: DATA1, DATA2, and carry-in. The second LUT
uses the same three signals to generate a carry-out signal, thereby creating
a carry chain. The arithmetic mode also supports simultaneous use of the
cascade chain. LEs in arithmetic mode can drive out registered and
unregistered versions of the LUT output.
The Quartus II software implements parameterized functions that use the
arithmetic mode automatically where appropriate; the designer does not
need to specify how the carry chain will be used.
Counter Mode
The counter mode offers clock enable, counter enable, synchronous
up/down control, synchronous clear, and synchronous load options. The
counter enable and synchronous up/down control signals are generated
from the data inputs of the LAB local interconnect. The synchronous clear
and synchronous load options are LAB-wide signals that affect all
registers in the LAB. Consequently, if any of the LEs in an LAB use the
counter mode, other LEs in that LAB must be used as part of the same
counter or be used for a combinatorial function. The Quartus II software
automatically places any registers that are not used by the counter into
other LABs.
18
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
The counter mode uses two 3-input LUTs: one generates the counter data,
and the other generates the fast carry bit. A 2-to-1 multiplexer provides
synchronous loading, and another AND gate provides synchronous
clearing. If the cascade function is used by an LE in counter mode, the
synchronous clear or load overrides any signal carried on the cascade
chain. The synchronous clear overrides the synchronous load. LEs in
arithmetic mode can drive out registered and unregistered versions of the
LUT output.
Clear & Preset Logic Control
Logic for the register’s clear and preset signals is controlled by LAB-wide
signals. The LE directly supports an asynchronous clear function. The
Quartus II Compiler can use a NOT-gate push-back technique to emulate
an asynchronous preset or to emulate simultaneous preset and clear or
asynchronous load. However, this technique uses three additional LEs per
register. All emulation is performed automatically when the design is
compiled. Registers that emulate simultaneous preset and load will enter
an unknown state upon power-up or when the chip-wide reset is asserted.
In addition to the two clear and preset modes, APEX 20KC devices
provide a chip-wide reset pin (DEV_CLRn) that resets all registers in the
device. Use of this pin is controlled through an option in the Quartus II
software that is set before compilation. The chip-wide reset overrides all
other control signals. Registers using an asynchronous preset are preset
when the chip-wide reset is asserted; this effect results from the inversion
technique used to implement the asynchronous preset.
FastTrack Interconnect
In the APEX 20KC architecture, connections between LEs, ESBs, and I/O
pins are provided by the FastTrack interconnect. The FastTrack
interconnect is a series of continuous horizontal and vertical routing
channels that traverse the device. This global routing structure provides
predictable performance, even in complex designs. In contrast, the
segmented routing in FPGAs requires switch matrices to connect a
variable number of routing paths, increasing the delays between logic
resources and reducing performance.
The FastTrack interconnect consists of row and column interconnect
channels that span the entire device. The row interconnect routes signals
throughout a row of MegaLAB structures; the column interconnect routes
signals throughout a column of MegaLAB structures. When using the row
and column interconnect, an LE, IOE, or ESB can drive any other LE, IOE,
or ESB in a device. See Figure 9.
Altera Corporation
19
APEX 20KC Programmable Logic Device Data Sheet
Figure 9. APEX 20KC Interconnect Structure
Row
Interconnect
I/O
I/O
I/O
I/O
I/O
I/O
MegaLAB
MegaLAB
MegaLAB
MegaLAB
I/O
MegaLAB
MegaLAB
MegaLAB
MegaLAB
I/O
MegaLAB
MegaLAB
MegaLAB
MegaLAB
I/O
Column
Interconnect
I/O
I/O
I/O
I/O
I/O
A row line can be driven directly by LEs, IOEs, or ESBs in that row.
Further, a column line can drive a row line, allowing an LE, IOE, or ESB to
drive elements in a different row via the column and row interconnect.
The row interconnect drives the MegaLAB interconnect to drive LEs,
IOEs, or ESBs in a particular MegaLAB structure.
A column line can be directly driven by LEs, IOEs, or ESBs in that column.
A column line on a device’s left or right edge can also be driven by row
IOEs. The column line is used to route signals from one row to another. A
column line can drive a row line; it can also drive the MegaLAB
interconnect directly, allowing faster connections between rows.
Figure 10 shows how the FastTrack interconnect uses the local
interconnect to drive LEs within MegaLAB structures.
20
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 10. FastTrack Connection to Local Interconnect
I/O
Row
L L
A A
B B
I/O
MegaLAB
Structure
L E
A S
B B
E L L
S A A
B B B
L
A
B
MegaLAB
Structure
Row & Column
Interconnect Drives
MegaLAB Interconnect
Column
Row
MegaLAB
Interconnect
MegaLAB
Interconnect Drives
Local Interconnect
Column
L
A
B
Altera Corporation
L
A
B
L
A
B
E
S
B
21
APEX 20KC Programmable Logic Device Data Sheet
Figure 11 shows the intersection of a row and column interconnect, and
how these forms of interconnects and LEs drive each other.
Figure 11. Driving the FastTrack Interconnect
Row Interconnect
MegaLAB Interconnect
Column
Interconnect
LE
Local
Interconnect
APEX 20KC devices include an enhanced interconnect structure for faster
routing of input signals with high fan-out. Column I/O pins can drive the
FastRowTM interconnect, which routes signals directly into the local
interconnect without having to drive through the MegaLAB interconnect.
The FastRow lines traverse two MegaLAB structures. Also, these pins can
drive the local interconnect directly for fast setup times. On EP20K400C
and larger devices, the FastRow interconnect drives the two MegaLAB
structures in the top left corner, the two MegaLAB structures in the two
right corner, the two MegaLAB structures in the bottom left corner, and
the two MegaLAB structures in the bottom right corner. On EP20K200C
and smaller devices, FastRow interconnect drives the two MegaLAB
structures on the top and the two MegaLAB structures on the bottom of
the device. On all devices, the FastRow interconnect drives all local
interconnect in the appropriate MegaLAB structures except the end local
interconnect on the side of the MegaLAB opposite the ESB. Pins using the
FastRow interconnect achieve a faster set-up time, as the signal does not
need to use a MegaLAB interconnect line to reach the destination LE.
Figure 12 shows the FastRow interconnect.
22
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 12. APEX 20KC FastRow Interconnect
FastRow
Interconnect
IOE
FastRow Interconnect
Drives Local Interconnect
in Two MegaLAB Structures
IOE
IOE
IOE
Select Vertical I/O Pins
Drive Local Interconnect
and FastRow
Interconnect
Local
Interconnect
LEs
MegaLAB
LABs
MegaLAB
Table 8 summarizes how various elements of the APEX 20KC architecture
drive each other.
Altera Corporation
23
APEX 20KC Programmable Logic Device Data Sheet
Table 8. APEX 20KC Routing Scheme
Source
Destination
Row Column
I/O Pin I/O Pin
LE
ESB
Local
MegaLAB
Interconnect Interconnect
v
Row I/O pin
v
FastRow
Column
Row
FastTrack Interconnect
FastTrack
Interconnect Interconnect
v
v
v
Column I/O
pin
LE
v
v
v
v
ESB
v
v
v
v
Local
interconnect
MegaLAB
interconnect
v
v
v
v
v
Row
FastTrack
interconnect
v
Column
FastTrack
interconnect
v
FastRow
interconnect
v
v
v
v
Product-Term Logic
The product-term portion of the MultiCore architecture is implemented
with the ESB. The ESB can be configured to act as a block of macrocells on
an ESB-by-ESB basis. Each ESB is fed by 32 inputs from the adjacent local
interconnect; therefore, it can be driven by the MegaLAB interconnect or
the adjacent LAB. Also, nine ESB macrocells feed back into the ESB
through the local interconnect for higher performance. Dedicated clock
pins, global signals, and additional inputs from the local interconnect
drive the ESB control signals.
In product-term mode, each ESB contains 16 macrocells. Each macrocell
consists of two product terms and a programmable register. Figure 13
shows the ESB in product-term mode.
24
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 13. Product-Term Logic in ESB
Dedicated Clocks
Global Signals
MegaLAB Interconnect
4
4
65
9
32
From
Adjacent
LAB
2
2
2
Macrocell
Inputs (1 to 16)
CLK[1..0]
16
To Row
and Column
Interconnect
ENA[1..0]
CLRN[1..0]
Local
Interconnect
Macrocells
APEX 20KC macrocells can be configured individually for either
sequential or combinatorial logic operation. The macrocell consists of
three functional blocks: the logic array, the product-term select matrix,
and the programmable register.
Combinatorial logic is implemented in the product terms. The productterm select matrix allocates these product terms for use as either primary
logic inputs (to the OR and XOR gates) to implement combinatorial
functions, or as parallel expanders to be used to increase the logic
available to another macrocell. One product term can be inverted; the
Quartus II software uses this feature to perform De Morgan’s inversion for
more efficient implementation of wide OR functions. The Quartus II
Compiler can use a NOT-gate push-back technique to emulate an
asynchronous preset. Figure 14 shows the APEX 20KC macrocell.
Altera Corporation
25
APEX 20KC Programmable Logic Device Data Sheet
Figure 14. APEX 20KC Macrocell
ESB-Wide ESB-Wide
ESB-Wide
Clears Clock Enables
Clocks
2
2
2
Parallel Logic
Expanders
(From Other
Macrocells)
ProductTerm
Select
Matrix
Programmable
Register
D
Clock/
Enable
Select
Q
ESB
Output
ENA
CLRN
32 Signals
from Local
Interconnect
Clear
Select
For registered functions, each macrocell register can be programmed
individually to implement D, T, JK, or SR operation with programmable
clock control. The register can be bypassed for combinatorial operation.
During design entry, the designer specifies the desired register type; the
Quartus II software then selects the most efficient register operation for
each registered function to optimize resource utilization. The Quartus II
software or other synthesis tools can also select the most efficient register
operation automatically when synthesizing HDL designs.
Each programmable register can be clocked by one of two ESB-wide
clocks. The ESB-wide clocks can be generated from device dedicated clock
pins, global signals, or local interconnect. Each clock also has an
associated clock enable, generated from the local interconnect. The clock
and clock enable signals are related for a particular ESB; any macrocell
using a clock also uses the associated clock enable.
If both the rising and falling edges of a clock are used in an ESB, both
ESB-wide clock signals are used.
26
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
The programmable register also supports an asynchronous clear function.
Within the ESB, two asynchronous clears are generated from global
signals and the local interconnect. Each macrocell can either choose
between the two asynchronous clear signals or choose to not be cleared.
Either of the two clear signals can be inverted within the ESB. Figure 15
shows the ESB control logic when implementing product-terms.
Figure 15. ESB Product-Term Mode Control Logic
Dedicated
Clocks
4
Global
Signals
4
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
CLK2
CLKENA2
CLK1
CLKENA1 CLR2
CLR1
Parallel Expanders
Parallel expanders are unused product terms that can be allocated to a
neighboring macrocell to implement fast, complex logic functions.
Parallel expanders allow up to 32 product terms to feed the macrocell OR
logic directly, with two product terms provided by the macrocell and
30 parallel expanders provided by the neighboring macrocells in the ESB.
The Quartus II Compiler can allocate up to 15 sets of up to two parallel
expanders per set to the macrocells automatically. Each set of two parallel
expanders incurs a small, incremental timing delay. Figure 16 shows the
APEX 20KC parallel expanders.
Altera Corporation
27
APEX 20KC Programmable Logic Device Data Sheet
Figure 16. APEX 20KC Parallel Expanders
From
Previous
Macrocell
ProductTerm
Select
Matrix
Macrocell
ProductTerm Logic
Parallel
Expander Switch
ProductTerm
Select
Matrix
Macrocell
ProductTerm Logic
Parallel
Expander Switch
32 Signals from
Local Interconnect
Embedded
System Block
To Next
Macrocell
The ESB can implement various types of memory blocks, including
dual-port RAM, ROM, FIFO, and CAM blocks. The ESB includes input
and output registers; the input registers synchronize writes, and the
output registers can pipeline designs to improve system performance. The
ESB offers a dual-port mode, which supports simultaneous reads and
writes at two different clock frequencies. Figure 17 shows the ESB block
diagram.
Figure 17. ESB Block Diagram
wraddress[]
data[]
wren
inclock
inclocken
inaclr
28
rdaddress[]
q[]
rden
outclock
outclocken
outaclr
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
ESBs can implement synchronous RAM, which is easier to use than
asynchronous RAM. A circuit using asynchronous RAM must generate
the RAM write enable (WE) signal, while ensuring that its data and address
signals meet setup and hold time specifications relative to the WE signal.
In contrast, the ESB’s synchronous RAM generates its own WE signal and
is self-timed with respect to the global clock. Circuits using the ESB’s selftimed RAM must only meet the setup and hold time specifications of the
global clock.
ESB inputs are driven by the adjacent local interconnect, which in turn can
be driven by the FastTrack or MegaLAB interconnect. Because the ESB can
be driven by the local interconnect, an adjacent LE can drive it directly for
fast memory access. ESB outputs drive the FastTrack and MegaLAB
interconnects. In addition, ten ESB outputs, nine of which are unique
output lines, drive the local interconnect for fast connection to adjacent
LEs or for fast feedback product-term logic.
When implementing memory, each ESB can be configured in any of the
following sizes: 128 × 16, 256 × 8, 512 × 4, 1,024 × 2, or 2,048 × 1. By
combining multiple ESBs, the Quartus II software implements larger
memory blocks automatically. For example, two 128 × 16 RAM blocks can
be combined to form a 128 × 32 RAM block, and two 512 × 4 RAM blocks
can be combined to form a 512 × 8 RAM block. Memory performance does
not degrade for memory blocks up to 2,048 words deep. Each ESB can
implement a 2,048-word-deep memory; the ESBs are used in parallel,
eliminating the need for any external control logic and its associated
delays.
To create a high-speed memory block that is more than 2,048 words deep,
ESBs drive tri-state lines. Each tri-state line connects all ESBs in a column
of MegaLAB structures, and drives the MegaLAB interconnect and row
and column FastTrack interconnect throughout the column. Each ESB
incorporates a programmable decoder to activate the tri-state driver
appropriately. For instance, to implement 8,192-word-deep memory, four
ESBs are used. Eleven address lines drive the ESB memory, and two more
drive the tri-state decoder. Depending on which 2,048-word memory
page is selected, the appropriate ESB driver is turned on, driving the
output to the tri-state line. The Quartus II software automatically
combines ESBs with tri-state lines to form deeper memory blocks. The
internal tri-state control logic is designed to avoid internal contention and
floating lines. See Figure 18.
Altera Corporation
29
APEX 20KC Programmable Logic Device Data Sheet
Figure 18. Deep Memory Block Implemented with Multiple ESBs
Address Decoder
ESB
to System Logic
ESB
ESB
The ESB implements two forms of dual-port memory: read/write clock
mode and input/output clock mode. The ESB can also be used for
bidirectional, dual-port memory applications in which two ports read or
write simultaneously. To implement this type of dual-port memory, two
ESBs are used to support two simultaneous reads or writes.
The ESB can also use Altera megafunctions to implement dual-port RAM
applications where both ports can read or write, as shown in Figure 19.
Figure 19. APEX 20KC ESB Implementing Dual-Port RAM
Port A
Port B
address_a[]
address_b[]
data_a[]
we_a
clkena_a
Clock A
30
data_b[]
we_b
clkena_b
Clock B
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Read/Write Clock Mode
The read/write clock mode contains two clocks. One clock controls all
registers associated with writing: data input, WE, and write address. The
other clock controls all registers associated with reading: read enable
(RE), read address, and data output. The ESB also supports clock enable
and asynchronous clear signals; these signals also control the read and
write registers independently. Read/write clock mode is commonly used
for applications where reads and writes occur at different system
frequencies. Figure 20 shows the ESB in read/write clock mode.
Figure 20. ESB in Read/Write Clock Mode
Note (1)
Dedicated Inputs &
Global Signals
Dedicated Clocks
4
RAM/ROM
128 × 16
256 × 8
512 × 4
Data In
1,024 × 2
2,048 × 1
4
data[ ]
D
Q
ENA
Data Out
D
ENA
ress[ ]
Q
To MegaLAB,
FastTrack &
Local
Interconnect
Address
D
Q
ENA
wren
Write Enable
utclken
nclken
D
ENA
nclock
Q
Write
Pulse
Generator
utclock
Note to Figure 20:
(1)
All registers can be cleared asynchronously by ESB local interconnect signals, global signals, or the chip-wide reset.
Altera Corporation
31
APEX 20KC Programmable Logic Device Data Sheet
Input/Output Clock Mode
The input/output clock mode contains two clocks. One clock controls all
registers for inputs into the ESB: data input, WE, RE, read address, and
write address. The other clock controls the ESB data output registers. The
ESB also supports clock enable and asynchronous clear signals; these
signals also control the reading and writing of registers independently.
Input/output clock mode is commonly used for applications where the
reads and writes occur at the same system frequency, but require different
clock enable signals for the input and output registers. Figure 21 shows
the ESB in input/output clock mode.
Figure 21. ESB in Input/Output Clock Mode
Note (1)
Dedicated Inputs &
Global Signals
Dedicated Clocks
4
RAM/ROM
128 × 16
256 × 8
512 × 4
Data In
1,024 × 2
2,048 × 1
4
data[ ]
D
Q
ENA
Data Out
D
ENA
rdaddress[ ]
Q
To MegaLAB,
FastTrack &
Local
Interconnect
Read Address
D
Q
ENA
wraddress[ ]
Write Address
D
Q
ENA
rden
Read Enable
D
Q
ENA
wren
Write Enable
outclken
inclken
D
ENA
inclock
Q
Write
Pulse
Generator
outclock
Note to Figure 21:
(1)
All registers can be cleared asynchronously by ESB local interconnect signals, global signals, or the chip-wide reset.
32
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Single-Port Mode
The APEX 20KC ESB also supports a single-port mode, which is used
when simultaneous reads and writes are not required. See Figure 22.
Figure 22. ESB in Single-Port Mode
Note (1)
Dedicated Inputs &
Global Signals
Dedicated Clocks
4
RAM/ROM
128 × 16
256 × 8
512 × 4
Data In
1,024 × 2
2,048 × 1
4
data[ ]
D
Q
ENA
Data Out
D
ENA
address[ ]
Q
To MegaLAB,
FastTrack &
Local
Interconnect
Address
D
Q
ENA
wren
Write Enable
outclken
inclken
D
inclock
ENA
Q
Write
Pulse
Generator
outclock
Note toFigure 22:
(1)
All registers can be asynchronously cleared by ESB local interconnect signals, global signals, or the chip-wide reset.
Content-Addressable Memory
In APEX 20KC devices, the ESB can implement CAM. CAM can be
thought of as the inverse of RAM. When read, RAM outputs the data for
a given address. Conversely, CAM outputs an address for a given data
word. For example, if the data FA12 is stored in address 14, the CAM
outputs 14 when FA12 is driven into it.
Altera Corporation
33
APEX 20KC Programmable Logic Device Data Sheet
CAM is used for high-speed search operations. When searching for data
within a RAM block, the search is performed serially. Thus, finding a
particular data word can take many cycles. CAM searches all addresses in
parallel and outputs the address storing a particular word. When a match
is found, a match flag is set high. Figure 23 shows the CAM block
diagram.
34
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 23. APEX 20KC CAM Block Diagram
wraddress[]
data[]
wren
inclock
inclocken
inaclr
data_address[]
match
outclock
outclocken
outaclr
CAM can be used in any application requiring high-speed searches, such
as networking, communications, data compression, and cache
management.
The APEX 20KC on-chip CAM provides faster system performance than
traditional discrete CAM. Integrating CAM and logic into the APEX 20KC
device eliminates off-chip and on-chip delays, improving system
performance.
When in CAM mode, the ESB implements 32-word, 32-bit CAM. Wider or
deeper CAM can be implemented by combining multiple CAMs with
some ancillary logic implemented in LEs. The Quartus II software
combines ESBs and LEs automatically to create larger CAMs.
CAM supports writing “don’t care” bits into words of the memory. The
“don’t care” bit can be used as a mask for CAM comparisons; any bit set
to “don’t care” has no effect on matches.
The output of the CAM can be encoded or unencoded. When encoded, the
ESB outputs an encoded address of the data’s location. For instance, if the
data is located in address 12, the ESB output is 12. When unencoded, the
ESB uses its 16 outputs to show the location of the data over two clock
cycles. In this case, if the data is located in address 12, the 12th output line
goes high. When using unencoded outputs, two clock cycles are required
to read the output because a 16-bit output bus is used to show the status
of 32 words.
The encoded output is better suited for designs that ensure duplicate data
is not written into the CAM. If duplicate data is written into two locations,
the CAM’s output will be incorrect. If the CAM may contain duplicate
data, the unencoded output is a better solution; CAM with unencoded
outputs can distinguish multiple data locations.
CAM can be pre-loaded with data during configuration, or it can be
written during system operation. In most cases, two clock cycles are
required to write each word into CAM. When “don’t care” bits are used,
a third clock cycle is required.
Altera Corporation
35
APEX 20KC Programmable Logic Device Data Sheet
f
For more information on APEX 20KC devices and CAM, see Application
Note 119 (Implementing High-Speed Search Applications with APEX CAM).
Driving Signals to the ESB
ESBs provide flexible options for driving control signals. Different clocks
can be used for the ESB inputs and outputs. Registers can be inserted
independently on the data input, data output, read address, write
address, WE, and RE signals. The global signals and the local interconnect
can drive the WE and RE signals. The global signals, dedicated clock pins,
and local interconnect can drive the ESB clock signals. Because the LEs
drive the local interconnect, the LEs can control the WE and RE signals and
the ESB clock, clock enable, and asynchronous clear signals. Figure 24
shows the ESB control signal generation logic.
Figure 24. ESB Control Signal Generation
Dedicated
Clocks
4
Global
Signals
4
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
WREN
RDEN
INCLKENA
INCLOCK
OUTCLKENA
OUTCLOCK
OUTCLR
INCLR
An ESB is fed by the local interconnect, which is driven by adjacent LEs
(for high-speed connection to the ESB) or the MegaLAB interconnect. The
ESB can drive the local, MegaLAB, or FastTrack interconnect routing
structure to drive LEs and IOEs in the same MegaLAB structure or
anywhere in the device.
36
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Implementing Logic in ROM
In addition to implementing logic with product terms, the ESB can
implement logic functions when it is programmed with a read-only
pattern during configuration, creating a large LUT. With LUTs,
combinatorial functions are implemented by looking up the results, rather
than by computing them. This implementation of combinatorial functions
can be faster than using algorithms implemented in general logic, a
performance advantage that is further enhanced by the fast access times
of ESBs. The large capacity of ESBs enables designers to implement
complex functions in one logic level without the routing delays associated
with linked LEs or distributed RAM blocks. Parameterized functions such
as LPM functions can take advantage of the ESB automatically. Further,
the Quartus II software can implement portions of a design with ESBs
where appropriate.
Programmable Speed/Power Control
APEX 20KC ESBs offer a high-speed mode that supports very fast
operation on an ESB-by-ESB basis. When high speed is not required, this
feature can be turned off to reduce the ESB’s power dissipation by up to
50%. ESBs that run at low power incur a nominal timing delay adder. This
Turbo BitTM option is available for ESBs that implement product-term
logic or memory functions. An ESB that is not used will be powered down
so that it does not consume DC current.
Designers can program each ESB in the APEX 20KC device for either
high-speed or low-power operation. As a result, speed-critical paths in the
design can run at high speed, while the remaining paths operate at
reduced power.
I/O Structure
The APEX 20KC IOE contains a bidirectional I/O buffer and a register
that can be used either as an input register for external data requiring fast
setup times or as an output register for data requiring fast clock-to-output
performance. IOEs can be used as input, output, or bidirectional pins.
Altera Corporation
37
APEX 20KC Programmable Logic Device Data Sheet
APEX 20KC devices include an enhanced IOE, which drives the FastRow
interconnect. The FastRow interconnect connects a column I/O pin
directly to the LAB local interconnect within two MegaLAB structures.
This feature provides fast setup times for pins that drive high fan-outs
with complex logic, such as PCI designs. For fast bidirectional I/O timing,
LE registers using local routing can improve setup times and OE timing.
The APEX 20KC IOE also includes direct support for open-drain
operation, giving faster clock-to-output for open-drain signals. Some
programmable delays in the APEX 20KC IOE offer multiple levels of
delay to fine-tune setup and hold time requirements. The Quartus II
Compiler sets these delays by default to minimize setup time while
providing a zero hold time.
The Quartus II Compiler uses the programmable inversion option to
invert signals from the row and column interconnect automatically where
appropriate. Because the APEX 20KC IOE offers one output enable per
pin, the Quartus II Compiler can emulate open-drain operation efficiently.
The APEX 20KC IOE includes programmable delays that can be activated
to ensure zero hold times, minimum clock-to-output times, input IOE
register-to-core register transfers, or core-to-output IOE register transfers.
A path in which a pin directly drives a register may require the delay to
ensure zero hold time, whereas a path in which a pin drives a register
through combinatorial logic may not require the delay.
Table 9 describes the APEX 20KC programmable delays and their logic
options in the Quartus II software.
Table 9. APEX 20KC Programmable Delay Chains
Programmable Delay
Quartus II Logic Option
Input pin to core delay
Decrease input delay to internal cells
Input pin to input register delay
Decrease input delay to input registers
Core to output register delay
Decrease input delay to output register
Output register tCO delay
Increase delay to output pin
Clock enable delay
Increase clock enable delay
The Quartus II Compiler can program these delays automatically to
minimize setup time while providing a zero hold time.
38
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
The register in the APEX 20KC IOE can be programmed to power-up high
or low after configuration is complete. If it is programmed to power-up
low, an asynchronous clear can control the register. If it is programmed to
power-up high, an asynchronous preset can control the register. This
feature is useful for cases where the APEX 20KC device controls an activelow input or another device; it prevents inadvertent activation of the input
upon power-up.
Figure 25 shows how fast bidirectional I/O pins are implemented in
APEX 20KC devices. This feature is useful for cases where the APEX 20KC
device controls an active-low input or another device; it prevents
inadvertent activation of the input upon power-up.
Altera Corporation
39
APEX 20KC Programmable Logic Device Data Sheet
Figure 25. APEX 20KC Bidirectional I/O Registers
Notes (1), (2)
Row, Column, FastRow, 4 Dedicated
or Local Interconnect Clock Inputs
4 Dedicated
Inputs
Peripheral Control
Bus
OE Register
D
Q
ENA
CLRN
VCC
Chip-Wide Reset
VCC
Chip-Wide
Output Enable
OE[7..0]
VCCIO
Input Pin to
Core Delay (1)
Optional
PCI Clamp
Input Pin to
Core Delay (1)
12
4
VCC
Core to Output
Register Delay
Output Register
Input Pin to Input
Register Delay
CLK[1..0]
D
Q
Output Register
t CO Delay
Open-Drain
Output
ENA
CLRN/
PRN
Slew-Rate
Control
CLK[3..0]
VCC
ENA[5..0]
Clock Enable
Delay (1)
VCC
CLRn[1..0]
Chip-Wide
Reset
Input Register
D
Input Pin to
Core Delay (1)
Q
VCC
ENA
CLRN
VCC
Chip-Wide
Reset
40
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Notes to Figure 25:
(1)
(2)
This programmable delay has four settings: off and three levels of delay.
The output enable and input registers are LE registers in the LAB adjacent to the bidirectional pin.
Each IOE drives a row, column, MegaLAB, or local interconnect when
used as an input or bidirectional pin. A row IOE can drive a local,
MegaLAB, row, and column interconnect; a column IOE can drive the
column interconnect. Figure 26 shows how a row IOE connects to the
interconnect.
Figure 26. Row IOE Connection to the Interconnect
Row Interconnect
Any LE can drive a
pin through the row,
column, and MegaLAB
interconnect.
MegaLAB Interconnect
IOE
LAB
Each IOE can drive local,
MegaLAB, row, and column
interconnect. Each IOE data
and OE signal is driven by
the local interconnect.
IOE
An LE can drive a pin through the
local interconnect for faster
clock-to-output times.
Altera Corporation
41
APEX 20KC Programmable Logic Device Data Sheet
Figure 27 shows how a column IOE connects to the interconnect.
Figure 27. Column IOE Connection to the Interconnect
Each IOE can drive a column interconnect. IOEs can also
drive FastRow and column interconnects. Each IOE data
and OE signal is driven by local interconnect.
IOE
IOE
An LE or ESB can drive a
pin through a local
interconnect for faster
clock-to-output times.
LAB
Any LE or ESB can drive
a column pin through a
row, column, and MegaLAB
interconnect.
Row Interconnect
Column Interconnect
MegaLAB Interconnect
Dedicated Fast I/O Pins
APEX 20KC devices incorporate an enhancement to support bidirectional
pins with high internal fan-out such as PCI control signals. These pins are
called dedicated fast I/O pins (FAST1, FAST2, FAST3, and FAST4) and
replace dedicated inputs. These pins can be used for fast clock, clear, or
high fan-out logic signal distribution. They also can drive out. The
dedicated fast I/O pin data output and tri-state control are driven by local
interconnect from the adjacent MegaLAB for high speed.
42
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Advanced I/O Standard Support
APEX 20KC IOEs support the following I/O standards: LVTTL,
LVCMOS, 1.8-V I/O, 2.5-V I/O, 3.3-V PCI, PCI-X, 3.3-V AGP, LVDS,
LVPECL, GTL+, CTT, HSTL Class I, SSTL-3 Class I and II, and SSTL-2
Class I and II.
f
For more information on I/O standards supported by APEX 20KC
devices, see Application Note 117 (Using Selectable I/O Standards in Altera
Devices).
The APEX 20KC device contains eight I/O banks. In QFP packages, the
banks are linked to form four I/O banks. The I/O banks directly support
all standards except LVDS and LVPECL. All I/O banks can support LVDS
and LVPECL at up to 156 Mbps per channel with the addition of external
resistors. In addition, one block within a bank contains circuitry to
support high-speed True-LVDS and LVPECL inputs, and another block
within a bank supports high-speed True-LVDS and LVPECL outputs. The
LVDS blocks support all of the I/O standards. Each I/O bank has its own
VCCIO pins. A single device can support 1.8-V, 2.5-V, and 3.3-V interfaces;
each bank can support a different standard independently. Each bank can
also use a separate VREF level so that each bank can support any of the
terminated standards (such as SSTL-3) independently. Within a bank, any
one of the terminated standards can be supported. EP20K400C and larger
APEX 20KC devices support the LVDS interface for data pins (EP20K200C
devices support LVDS clock pins, but not data pins). EP20K400C and
EP20K600C devices support LVDS for data pins at up to 840 Mbps per
channel. EP20K1000C devices support LVDS on 16 channels at up to 750
Mbps.
Each bank can support multiple standards with the same VCCIO for
output pins. Each bank can support one voltage-referenced I/O standard,
but it can support multiple I/O standards with the same VCCIO voltage
level. For example, when VCCIO is 3.3 V, a bank can support LVTTL,
LVCMOS, 3.3-V PCI, and SSTL-3 for inputs and outputs.
When the LVDS banks are not used for the LVDS I/O standard, they
support all of the other I/O standards. Figure 28 shows the arrangement
of the APEX 20KC I/O banks.
Altera Corporation
43
APEX 20KC Programmable Logic Device Data Sheet
Figure 28. APEX 20KC I/O Banks
I/O Bank 1
I/O Bank 8
LVDS Output
Block (2)
(1)
I/O Bank 2
I/O Bank 3
Regular I/O Banks Support
■ LVPECL
■ LVTTL
■ LVCMOS
■ 2.5 V
■ 1.8 V
■ 3.3-V PCI
■ GTL+
■ HSTL
■ SSTL-2 Class I and II
■ SSTL-3 Class I and II
■ CTT
■ AGP
(1)
LVDS Input
Block (2)
I/O Bank 4
Individual
Power Bus
I/O Bank 7
I/O Bank 6
I/O Bank 5
Notes to Figure 28:
(1)
(2)
For more information on placing I/O pins in LVDS blocks, refer to the “Guidelines for Using LVDS Blocks” section
in Application Note 120 (Using LVDS in APEX 20KE Devices).
If the LVDS input and output blocks are not used for LVDS, they can support all of the I/O standards and can be
used as input, output, or bidirectional pins with VCCIO set to 3.3 V, 2.5 V, or 1.8 V.
Power Sequencing & Hot Socketing
Because APEX 20KC devices can be used in a mixed-voltage environment,
they have been designed specifically to tolerate any possible power-up
sequence. Therefore, the VCCIO and VCCINT power supplies may be
powered in any order.
44
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Signals can be driven into APEX 20KC devices before and during powerup without damaging the device. In addition, APEX 20KC devices do not
drive out during power-up. Once operating conditions are reached and
the device is configured, APEX 20KC devices operate as specified by the
user.
MultiVolt I/O
Interface
The APEX architecture supports the MultiVolt I/O interface feature,
which allows APEX devices in all packages to interface with systems of
different supply voltages. The devices have one set of VCC pins for
internal operation and input buffers (VCCINT), and another set for I/O
output drivers (VCCIO).
APEX 20KC devices support the MultiVolt I/O interface feature. The
APEX 20KC VCCINT pins must always be connected to a 1.8-V power
supply. With a 1.8-V VCCINT level, input pins are 1.8-V, 2.5-V, and 3.3-V
tolerant. The VCCIO pins can be connected to either a 1.8-V, 2.5-V, or 3.3-V
power supply, depending on the I/O standard requirements. When the
VCCIO pins are connected to a 1.8-V power supply, the output levels are
compatible with 1.8-V systems. When VCCIO pins are connected to a 2.5-V
power supply, the output levels are compatible with 2.5-V systems. When
VCCIO pins are connected to a 3.3-V power supply, the output high is
3.3 V and compatible with 3.3-V or 5.0-V systems. An APEX 20KC device
is 5.0-V tolerant with the addition of a resistor and the PCI clamp diode
enabled.
f
For more information on 5.0-V tolerance, refer to the “5.0-V Tolerance in
APEX 20KE Devices White Paper,” as the information found therein also
applies to APEX 20KC devices.
Table 10 summarizes APEX 20KC MultiVolt I/O support.
Table 10. APEX 20KC MultiVolt I/O Support
VCCIO (V)
Input Signals (V)
1.8
2.5
3.3
v
v (1)
v (1)
2.5
v
v (1)
3.3
v
v
1.8
Output Signals (V)
5.0
1.8
2.5
3.3
5.0
v
v
v
v
v (2)
v (3)
Notes to Table 10:
(1)
(2)
(3)
The PCI clamping diode must be disabled to drive an input with voltages higher than VCCIO, except for the 5.0-V
input case.
An APEX 20KC device can be made 5.0-V tolerant with the addition of an external resistor and the PCI clamp diode
enabled.
When VCCIO = 3.3 V, an APEX 20KC device can drive a 2.5-V device with 3.3-V tolerant inputs.
Altera Corporation
45
APEX 20KC Programmable Logic Device Data Sheet
Open-drain output pins on APEX 20KC devices (with a series resistor and
a pull-up resistor to the 5.0-V supply) can drive 5.0-V CMOS input pins
that require a VIH of 3.5 V. When the pin is inactive, the trace will be pulled
up to 5.0 V by the resistor. The open-drain pin will only drive low or tristate; it will never drive high. The rise time is dependent on the value of
the pull-up resistor and load impedance. The IOL current specification
should be considered when selecting a pull-up resistor.
ClockLock &
ClockBoost
Features
APEX 20KC devices support the ClockLock and ClockBoost clock
management features, which are implemented with PLLs. The ClockLock
circuitry uses a synchronizing PLL that reduces the clock delay and skew
within a device. This reduction minimizes clock-to-output and setup
times while maintaining zero hold times. The ClockBoost circuitry, which
provides a clock multiplier, allows the designer to enhance device area
efficiency by sharing resources within the device. The ClockBoost
circuitry allows the designer to distribute a low-speed clock and multiply
that clock on-device. APEX 20KC devices include a high-speed clock tree;
unlike ASICs, the user does not have to design and optimize the clock tree.
The ClockLock and ClockBoost features work in conjunction with the
APEX 20KC device’s high-speed clock to provide significant
improvements in system performance and bandwidth. APEX 20KC
devices in -7 and -8 speed grades have PLLs and support the ClockLock
and ClockBoost features.
The ClockLock and ClockBoost features in APEX 20KC devices are
enabled through the Quartus II software. External devices are not
required to use these features.
APEX 20KC ClockLock Feature
APEX 20KC devices include up to four PLLs, which can be used
independently. Two PLLs are designed for either general-purpose use or
LVDS use (on devices that support LVDS I/O pins). The remaining two
PLLs are designed for general-purpose use. The EP20K200C devices have
two PLLs; the EP20K400C and larger devices have four PLLs.
The following sections describe some of the features offered by the
APEX 20KC PLLs.
External PLL Feedback
The ClockLock circuit’s output can be driven off-chip to clock other
devices in the system; further, the feedback loop of the PLL can be routed
off-chip. This feature allows the designer to exercise fine control over the
I/O interface between the APEX 20KC device and another high-speed
device, such as SDRAM.
46
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Clock Multiplication
The APEX 20KC ClockBoost circuit can multiply or divide clocks by a
programmable number. The clock can be multiplied by m/(n × k), where
m and k range from 2 to 160 and n ranges from 1 to 16. Clock multiplication
and division can be used for time-domain multiplexing and other
functions, which can reduce design LE requirements.
Clock Phase & Delay Adjustment
The APEX 20KC ClockShift feature allows the clock phase and delay to be
adjusted. The clock phase can be adjusted by 90° steps. The clock delay
can be adjusted to increase or decrease the clock delay by an arbitrary
amount, up to one clock period.
LVDS Support
All APEX 20KC devices support differential LVDS buffers on the input
and output clock signals that interface with external devices. This is
controlled in the Quartus II software by assigning the clock pins with an
LVDS I/O standard assignment.
Two high-speed PLLs are designed to support the LVDS interface. When
using LVDS, the I/O clock runs at a slower rate than the data transfer rate.
Thus, PLLs are used to multiply the I/O clock internally to capture the
LVDS data. For example, an I/O clock may run at 105 MHz to support
840 Mbps LVDS data transfer. In this example, the PLL multiplies the
incoming clock by eight to support the high-speed data transfer. You can
use PLLs in EP20K400C and larger devices for high-speed LVDS
interfacing.
Lock Signals
The APEX 20KC ClockLock circuitry supports individual LOCK signals.
The LOCK signal drives high when the ClockLock circuit has locked onto
the input clock. The LOCK signals are optional for each ClockLock circuit;
when not used, they are I/O pins.
Altera Corporation
47
APEX 20KC Programmable Logic Device Data Sheet
ClockLock & ClockBoost Timing Parameters
For the ClockLock and ClockBoost circuitry to function properly, the
incoming clock must meet certain requirements. If these specifications are
not met, the circuitry may not lock onto the incoming clock, which
generates an erroneous clock within the device. The clock generated by
the ClockLock and ClockBoost circuitry must also meet certain
specifications. If the incoming clock meets these requirements during
configuration, the APEX 20KC ClockLock and ClockBoost circuitry will
lock onto the clock during configuration. The circuit will be ready for use
immediately after configuration. In APEX 20KC devices, the clock input
standard is programmable, so the PLL cannot respond to the clock until
the device is configured. The PLL locks onto the input clock as soon as
configuration is complete. Figure 29 shows the incoming and generated
clock specifications.
1
For more information on ClockLock and ClockBoost circuitry,
see Application Note 115: Using the ClockLock and ClockBoost PLL
Features in APEX Devices.
Figure 29. Specifications for the Incoming & Generated Clocks
The tI parameter refers to the nominal input clock period; the tO parameter refers to the
nominal output clock period.
f CLK1, f CLK2 ,
f CLK4
t INDUTY
t I + t CLKDEV
Input
Clock
t R (1)
t F (1)
tO
tI
+
t INCLKSTB
t OUTDUTY
ClockLock
Generated
Clock
tO
tO
+ t JITTER
tO
t JITTER
Note to Figure 29:
(1)
48
Rise and fall times are measured from 10% to 90%.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Tables 11 and 12 summarize the ClockLock and ClockBoost parameters
for APEX 20KC devices.
Table 11. APEX 20KC ClockLock & ClockBoost Parameters
Symbol
Parameter
tR
Input rise time
tF
Input fall time
t INDUTY
Input duty cycle
t INJITTER
Input jitter peak-to-peak
tOUTJITTER
RMS jitter on ClockLock or
ClockBoost-generated clock
tOUTDUTY
Duty cycle for ClockLock or
ClockBoost-generated clock
Condition
Note (1)
Min
Typ
Parameter
ns
ns
%
2% of input
period
%
0.35% of
output
period
%
55
%
40
µs
45
I/O Standard
5
5
tLOCK (2), (3) Time required for ClockLock or
ClockBoost to acquire lock
Symbol
Unit
60
40
Table 12. APEX 20KC Clock Input & Output Parameters (Part 1 of 2)
Max
Note (1)
-7 Speed Grade
-8 Speed Grade
Min
Max
Min
Max
Units
fVCO (4)
Voltage controlled oscillator
operating range
200
500
200
500
MHz
fCLOCK0
Clock0 PLL output frequency
for internal use
1.5
335
1.5
200
MHz
fCLOCK1
Clock1 PLL output frequency
for internal use
20
335
20
200
MHz
fCLOCK0_EXT
Output clock frequency for
external clock0 output
3.3-V LVTTL
(5)
(5)
(5)
(5)
MHz
2.5-V LVTTL
(5)
(5)
(5)
(5)
MHz
1.8-V LVTTL
(5)
(5)
(5)
(5)
MHz
Altera Corporation
GTL+
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class II
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class II
(5)
(5)
(5)
(5)
MHz
LVDS
(5)
(5)
(5)
(5)
MHz
49
APEX 20KC Programmable Logic Device Data Sheet
Table 12. APEX 20KC Clock Input & Output Parameters (Part 2 of 2)
Symbol
fCLOCK1_EXT
fIN
Parameter
Output clock frequency for
external clock1 output
Input clock frequency
I/O Standard
Note (1)
-7 Speed Grade
-8 Speed Grade
Units
Min
Max
Min
Max
3.3-V LVTTL
(5)
(5)
(5)
(5)
MHz
2.5-V LVTTL
(5)
(5)
(5)
(5)
MHz
1.8-V LVTTL
(5)
(5)
(5)
(5)
MHz
GTL+
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class II
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class II
(5)
(5)
(5)
(5)
MHz
LVDS
(5)
(5)
(5)
(5)
MHz
3.3-V LVTTL
(5)
(5)
(5)
(5)
MHz
2.5-V LVTTL
(5)
(5)
(5)
(5)
MHz
1.8-V LVTTL
(5)
(5)
(5)
(5)
MHz
GTL+
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-2 Class II
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class I
(5)
(5)
(5)
(5)
MHz
SSTL-3 Class II
(5)
(5)
(5)
(5)
MHz
LVDS
(5)
(5)
(5)
(5)
MHz
Notes to Tables 11 and 12:
(1)
(2)
(3)
(4)
(5)
All input clock specifications must be met. The PLL may not lock onto an incoming clock if the clock specifications
are not met, creating an erroneous clock within the device.
The maximum lock time is 40 µs or 2,000 input clock cycles, whichever occurs first.
Before configuration, the PLL circuits are disable and powered down. During configuration, the PLLs remain
disabled. The PLLs begin to lock once the device is in the user mode. If the clock enable feature is used, lock begins
once the CLKLK_ENA pin goes high in user mode.
The PLL VCO operating range is 200 MHz ≤ fVCO ≤ 840 MHz for LVDS mode.
Contact Altera Applications for information on these parameters.
SignalTap
Embedded
Logic Analyzer
50
APEX 20KC devices include device enhancements to support the
SignalTap embedded logic analyzer. By including this circuitry, the
APEX 20KC device provides the ability to monitor design operation over
a period of time through the IEEE Std. 1149.1 (JTAG) circuitry; a designer
can analyze internal logic at speed without bringing internal signals to the
I/O pins. This feature is particularly important for advanced packages
such as FineLine BGA packages because adding a connection to a pin
during the debugging process can be difficult after a board is designed
and manufactured.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
IEEE Std.
1149.1 (JTAG)
Boundary-Scan
Support
All APEX 20KC devices provide JTAG BST circuitry that complies with
the IEEE Std. 1149.1-1990 specification. JTAG boundary-scan testing can
be performed before or after configuration, but not during configuration.
APEX 20KC devices can also use the JTAG port for configuration with the
Quartus II software or with hardware using either Jam Files (.jam) or Jam
Byte-Code Files (.jbc). Finally, APEX 20KC devices use the JTAG port to
monitor the logic operation of the device with the SignalTap embedded
logic analyzer. APEX 20KC devices support the JTAG instructions shown
in Table 13.
Table 13. APEX 20KC JTAG Instructions
JTAG Instruction
Description
SAMPLE/PRELOAD Allows a snapshot of signals at the device pins to be captured and examined during
normal device operation, and permits an initial data pattern to be output at the device pins.
Also used by the SignalTap embedded logic analyzer.
EXTEST
Allows the external circuitry and board-level interconnections to be tested by forcing a test
pattern at the output pins and capturing test results at the input pins.
BYPASS
Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data
to pass synchronously through selected devices to adjacent devices during normal device
operation.
USERCODE
Selects the 32-bit USERCODE register and places it between the TDI and TDO pins,
allowing the USERCODE to be serially shifted out of TDO.
IDCODE
Selects the IDCODE register and places it between TDI and TDO, allowing the IDCODE
to be serially shifted out of TDO.
ICR Instructions
Used when configuring an APEX 20KC device via the JTAG port with a MasterBlasterTM
or ByteBlasterMVTM download cable, or when using a Jam File or Jam Byte-Code File via
an embedded processor.
SignalTap
Instructions
Monitors internal device operation with the SignalTap embedded logic analyzer.
Altera Corporation
51
APEX 20KC Programmable Logic Device Data Sheet
The APEX 20KC device instruction register length is 10 bits. The
APEX 20KC device USERCODE register length is 32 bits. Tables 14 and 15
show the boundary-scan register length and device IDCODE information
for APEX 20KC devices.
Table 14. APEX 20KC Boundary-Scan Register Length
Device
Boundary-Scan Register Length
EP20K200C
1,164
EP20K400C
1,506
EP20K600C
1,806
EP20K1000C
2,190
Table 15. 32-Bit APEX 20KC Device IDCODE
Device
IDCODE (32 Bits) (1)
Version
(4 Bits)
Part Number (16 Bits)
Manufacturer
Identity (11 Bits)
1 (1 Bit)
(2)
EP20K200C
0000
1000 0010 0000 0000
000 0110 1110
1
EP20K400C
0000
1000 0100 0000 0000
000 0110 1110
1
EP20K600C
0000
1000 0110 0000 0000
000 0110 1110
1
EP20K1000C
0000
1001 0000 0000 0000
000 0110 1110
1
Notes to Table 15:
(1)
(2)
The most significant bit (MSB) is on the left.
The IDCODE’s least significant bit (LSB) is always 1.
Figure 30 shows the timing requirements for the JTAG signals.
52
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 30. APEX 20KC JTAG Waveforms
TMS
TDI
t JCP
t JCH
t JCL
t JPH
t JPSU
TCK
tJPZX
t JPXZ
t JPCO
TDO
tJSH
tJSSU
Signal
to Be
Captured
Signal
to Be
Driven
tJSCO
tJSZX
tJSXZ
Table 16 shows the JTAG timing parameters and values for APEX 20KC
devices.
Table 16. APEX 20KC JTAG Timing Parameters & Values
Symbol
f
Min
Max
Unit
tJCP
TCK clock period
tJCH
TCK clock high time
tJCL
TCK clock low time
50
ns
tJPSU
JTAG port setup time
20
ns
tJPH
JTAG port hold time
45
tJPCO
JTAG port clock to output
25
tJPZX
JTAG port high impedance to valid output
25
ns
tJPXZ
JTAG port valid output to high impedance
25
ns
tJSSU
Capture register setup time
20
ns
tJSH
Capture register hold time
45
ns
tJSCO
Update register clock to output
35
ns
tJSZX
Update register high impedance to valid output
35
ns
tJSXZ
Update register valid output to high impedance
35
ns
100
ns
50
ns
ns
ns
For more information, see the following documents:
■
Altera Corporation
Parameter
Application Note 39 (IEEE Std. 1149.1 (JTAG) Boundary-Scan Testing in
Altera Devices)
53
APEX 20KC Programmable Logic Device Data Sheet
■
Generic Testing
Each APEX 20KC device is functionally tested. Complete testing of each
configurable SRAM bit and all logic functionality ensures 100% yield.
AC test measurements for APEX 20KC devices are made under conditions
equivalent to those defined in the “Timing Model” section on page 65.
Multiple test patterns can be used to configure devices during all stages of
the production flow. AC test criteria include:
■
■
■
■
Operating
Conditions
Jam Programming & Test Language Specification
Power supply transients can affect AC measurements.
Simultaneous transitions of multiple outputs should be avoided for
accurate measurement.
Threshold tests must not be performed under AC conditions.
Large-amplitude, fast-ground-current transients normally occur as
the device outputs discharge the load capacitances. When these
transients flow through the parasitic inductance between the device
ground pin and the test system ground, significant reductions in
observable noise immunity can result.
Tables 17 through 20 provide information on absolute maximum ratings,
recommended operating conditions, DC operating conditions, and
capacitance for 1.8-V APEX 20KC devices.
Table 17. APEX 20KC Device Absolute Maximum Ratings
Symbol
Parameter
V CCINT Supply voltage
Note (1)
Conditions
Min
Max
Unit
With respect to ground (2)
–0.5
2.5
V
V CCIO
–0.5
4.6
V
–0.5
4.6
V
–25
25
mA
–65
150
°C
135
°C
PQFP, RQFP, TQFP, and BGA
packages, under bias
135
°C
Ceramic PGA packages, under bias
150
°C
VI
DC input voltage
I OUT
DC output current, per pin
T STG
Storage temperature
No bias
T AMB
Ambient temperature
Under bias
–65
TJ
Junction temperature
54
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 18. APEX 20KC Device Recommended Operating Conditions
Symbol
Parameter
Conditions
Min
Max
Unit
V CCINT
Supply voltage for internal logic
and input buffers
(3), (4)
1.71
(1.71)
1.89
(1.89)
V
V CCIO
Supply voltage for output buffers,
3.3-V operation
(3), (4)
3.00
(3.00)
3.60
(3.60)
V
Supply voltage for output buffers,
2.5-V operation
(3), (4)
2.375
(2.375)
2.625
(2.625)
V
Supply voltage for output buffers,
1.8-V operation
(3), (4)
1.71
(1.71)
1.89
(1.89)
V
(2), (5)
–0.5
4.1
V
0
V CCIO
V
0
85
°C
–40
VI
Input voltage
VO
Output voltage
TJ
Operating junction temperature
100
°C
tR
Input rise time (10% to 90%)
40
ns
tF
Input fall time (90% to 10%)
40
ns
For commercial use
For industrial use
Table 19. APEX 20KC Device DC Operating Conditions
Symbol
Parameter
Notes (6), (7)
Conditions
Min
Typ
Max
Unit
II
Input pin leakage current (8)
V I = 3.6 to 0.0 V
–10
10
µA
I OZ
Tri-stated I/O pin leakage
current (8)
V O = 4.1 to –0.5 V
–10
10
µA
I CC0
V CC supply current (standby)
(All ESBs in power-down
mode)
V I = ground, no load,
no toggling inputs,
-7 speed grade
10
mA
V I = ground, no load,
no toggling inputs,
-8, -9 speed grades
5
mA
R CONF
Value of I/O pin pull-up
resistor before and during
configuration
1
Altera Corporation
V CCIO = 3.0 V (9)
20
50
kΩ
V CCIO = 2.375 V (9)
V CCIO = 1.71 V (9)
30
80
kΩ
60
150
kΩ
DC operating specifications on APEX 20KC I/O standards are
listed in Tables 21 to 35.
55
APEX 20KC Programmable Logic Device Data Sheet
Table 20. APEX 20KC Device Capacitance
Symbol
Note (10)
Parameter
Conditions
Min
Max
Unit
CIN
Input capacitance
VIN = 0 V, f = 1.0 MHz
8
pF
CINCLK
Input capacitance on
dedicated clock pin
VIN = 0 V, f = 1.0 MHz
12
pF
COUT
Output capacitance
VOUT = 0 V, f = 1.0 MHz
8
pF
Notes to Tables 17 through 20:
(1)
(2)
See the Operating Requirements for Altera Devices Data Sheet.
Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 4.6 V for input
currents less than 100 mA and time periods shorter than 20 ns.
(3) Numbers in parentheses are for industrial-temperature-range devices.
(4) Maximum VCC rise time is 100 ms, and VCC must rise monotonically.
(5) All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before VCCINT and VCCIO are
powered.
(6) Typical values are for T A = 25° C, V CCINT = 1.8 V, and V CCIO = 1.8 V, 2.5 V or 3.3 V.
(7) These values are specified under the APEX 20KC device recommended operating conditions, shown in Table 18 on
page 55.
(8) This value is specified for normal device operation. The value may vary during power-up.
(9) Pin pull-up resistance values will be lower if an external source drives the pin higher than VCCIO.
(10) Capacitance is sample-tested only.
Tables 21 through 35 list the DC operating specifications for the supported
I/O standards. These tables list minimal specifications only; APEX 20KC
devices may exceed these specifications.
Table 21. LVTTL I/O Specifications
Symbol
Parameter
Conditions
Minimum
Maximum
Units
VCCIO
Output supply
voltage
3.0
3.6
V
VIH
High-level input
voltage
2.0
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
0.8
V
II
Input pin leakage
current
VIN = 0 V or 3.3 V
–10
10
µA
VOH
High-level output
voltage
IOH = –12 mA,
VCCIO = 3.0 V (1)
2.4
VOL
Low-level output
voltage
IOL = 12 mA,
VCCIO = 3.0 V (2)
56
V
0.4
V
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 22. LVCMOS I/O Specifications
Symbol
Parameter
Conditions
Minimum
Maximum
Units
VCCIO
Power supply
voltage range
3.0
3.6
V
VIH
High-level input
voltage
2.0
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
0.8
V
II
Input pin leakage
current
VIN = 0 V or 3.3 V
–10
10
µA
VOH
High-level output
voltage
VCCIO = 3.0 V
IOH = –0.1 mA (1)
VCCIO – 0.2
VOL
Low-level output
voltage
VCCIO = 3.0 V
IOL = 0.1 mA (2)
V
0.2
V
Minimum
Maximum
Units
2.375
2.625
V
Table 23. 2.5-V I/O Specifications
Symbol
Parameter
Conditions
VCCIO
Output supply
voltage
VIH
High-level input
voltage
1.7
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
0.8
V
II
Input pin leakage
current
VIN = 0 V or 3.3 V
–10
10
µA
VOH
High-level output
voltage
IOH = –0.1 mA (1)
2.1
V
IOH = –1 mA (1)
2.0
V
IOH = –2 mA (1)
1.7
VOL
Low-level output
voltage
Altera Corporation
V
IOL = 0.1 mA (2)
0.2
V
IOL = 1 mA (2)
0.4
V
IOL = 2 mA (2)
0.7
V
57
APEX 20KC Programmable Logic Device Data Sheet
Table 24. 1.8-V I/O Specifications
Symbol
Parameter
Conditions
VCCIO
Output supply
voltage
VIH
High-level input
voltage
VIL
Low-level input
voltage
II
Input pin leakage
current
VIN = 0 V or 3.3 V
VOH
High-level output
voltage
IOH = –2 mA (1)
VOL
Low-level output
voltage
IOL = 2 mA (2)
Minimum
Maximum
Units
1.7
1.9
V
0.65 × VCCIO
VCCIO + 0.3
V
0.35 × VCCIO
V
10
µA
–10
VCCIO – 0.45
V
0.45
V
Table 25. 3.3-V PCI Specifications
Symbol
Parameter
Conditions
Minimum
Typical
3.0
3.3
Maximum
Units
VCCIO
I/O supply voltage
3.6
V
VIH
High-level input
voltage
0.5 × VCCIO
VCCIO + 0.5
V
VIL
Low-level input
voltage
–0.5
0.3 × VCCIO
V
II
Input pin leakage
current
0 < VIN < VCCIO
–10
10
µA
VOH
High-level output
voltage
IOUT = –500 µA
0.9 × VCCIO
VOL
Low-level output
voltage
IOUT = 1,500 µA
58
V
0.1 × VCCIO
V
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 26. 3.3-V PCI-X Specifications
Symbol
Parameter
Conditions
Minimum
Typical
Maximum
Units
3.0
3.3
3.6
V
VCCIO
Output supply
voltage
VIH
High-level input
voltage
0.5 × VCCIO
VCCIO + 0.5
V
VIL
Low-level input
voltage
–0.5
0.35 × VCCIO
V
VIPU
Input pull-up voltage
IIL
Input pin leakage
current
0 < VIN < VCCIO
–10.0
10.0
µA
VOH
High-level output
voltage
IOUT = –500 µA
0.9 × VCCIO
VOL
Low-level output
voltage
IOUT = 1,500 µA
Lpin
Pin Inductance
0.7 × VCCIO
V
V
0.1 × VCCIO
V
15.0
nH
Units
Table 27. 3.3-V LVDS I/O Specifications
Symbol
Parameter
Conditions
VCCIO
I/O supply voltage
VOD
Differential output
voltage
RL = 100 Ω
∆ VOD
Change in VOD
between high and
low
RL = 100 Ω
VOS
Output offset voltage RL = 100 Ω
∆ VOS
Change in VOS
between high and
low
RL = 100 Ω
VTH
Differential input
threshold
VCM = 1.2 V
VIN
RL
Minimum
Typical
Maximum
3.135
3.3
3.465
V
650
mV
50
mV
250
1.375
V
50
mV
–100
100
mV
Receiver input
voltage range
0.0
2.4
V
Receiver differential
input resistor
(external to APEX
devices)
90
110
Ω
Altera Corporation
1.125
1.25
100
59
APEX 20KC Programmable Logic Device Data Sheet
Table 28. GTL+ I/O Specifications
Symbol
Parameter
VTT
Termination voltage
VREF
Reference voltage
VIH
High-level input
voltage
VIL
Low-level input
voltage
VOL
Low-level output
voltage
Conditions
Minimum
Typical
Maximum
Units
1.35
1.5
1.65
V
0.88
1.0
1.12
VREF + 0.1
V
V
IOL = 36 mA (2)
VREF – 0.1
V
0.65
V
Maximum
Units
Table 29. SSTL-2 Class I Specifications
Symbol
Parameter
Conditions
Minimum
Typical
VCCIO
I/O supply voltage
VTT
Termination voltage
VREF
Reference voltage
1.35
V
VIH
High-level input
voltage
VREF + 0.18
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
VREF – 0.18
V
VOH
High-level output
voltage
IOH = –7.6 mA (1)
VOL
Low-level output
voltage
IOL = 7.6 mA (2)
60
2.375
2.5
2.625
V
VREF – 0.04
VREF
VREF + 0.04
V
1.15
1.25
VTT + 0.57
V
VTT – 0.57
V
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 30. SSTL-2 Class II Specifications
Symbol
Parameter
VCCIO
I/O supply voltage
Conditions
Minimum
Typical
Maximum
Units
2.375
2.5
2.625
V
VREF – 0.04
VREF
VREF + 0.04
V
1.15
1.25
1.35
V
VTT
Termination voltage
VREF
Reference voltage
VIH
High-level input
voltage
VREF + 0.18
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
VREF – 0.18
V
VOH
High-level output
voltage
IOH = –15.2 mA (1)
VOL
Low-level output
voltage
IOL = 15.2 mA (2)
VTT + 0.76
V
VTT – 0.76
V
Table 31. SSTL-3 Class I Specifications
Symbol
Parameter
VCCIO
I/O supply voltage
Conditions
Minimum
Typical
Maximum
Units
3.0
3.3
3.6
V
VREF – 0.05
VREF
VREF + 0.05
V
1.3
1.5
1.7
V
VTT
Termination voltage
VREF
Reference voltage
VIH
High-level input
voltage
VREF + 0.2
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
VREF – 0.2
V
VOH
High-level output
voltage
IOH = –8 mA (1)
VOL
Low-level output
voltage
IOL = 8 mA (2)
Altera Corporation
VTT + 0.6
V
VTT – 0.6
V
61
APEX 20KC Programmable Logic Device Data Sheet
Table 32. SSTL-3 Class II Specifications
Symbol
Parameter
VCCIO
I/O supply voltage
Conditions
Minimum
Typical
Maximum
Units
3.0
3.3
3.6
V
VREF – 0.05
VREF
VREF + 0.05
V
1.3
1.5
1.7
V
VTT
Termination voltage
VREF
Reference voltage
VIH
High-level input
voltage
VREF + 0.2
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
VREF – 0.2
V
VOH
High-level output
voltage
IOH = –16 mA (1)
VOL
Low-level output
voltage
IOL = 16 mA (2)
VTT + 0.8
V
VTT – 0.8
V
Table 33. HSTL Class I I/O Specifications
Symbol
Parameter
VCCIO
I/O supply voltage
Conditions
Minimum
Typical
Maximum
Units
1.71
1.8
1.89
V
VREF – 0.05
VREF
VREF + 0.05
V
0.68
0.75
0.90
V
VTT
Termination voltage
VREF
Reference voltage
VIH
High-level input
voltage
VREF + 0.1
VCCIO + 0.3
V
VIL
Low-level input
voltage
–0.3
VREF – 0.1
V
VOH
High-level output
voltage
IOH = –8 mA (1)
VOL
Low-level output
voltage
IOL = 8 mA (2)
62
VCCIO – 0.4
V
0.4
V
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 34. 3.3-V AGP I/O Specifications
Symbol
Parameter
Conditions
Minimum
Typical
Maximum
Units
3.3
3.45
V
VCCIO
I/O supply voltage
3.15
VREF
Reference voltage
0.39 × VCCIO
0.41 × VCCIO
V
VIH
High-level input
voltage
0.5 × VCCIO
VCCIO + 0.5
V
VIL
Low-level input
voltage
0.3 × VCCIO
V
VOH
High-level output
voltage
IOUT = –500 µA
3.6
V
VOL
Low-level output
voltage
IOUT = 1,500 µA
0.1 × VCCIO
V
II
Input pin leakage
current
0 < VIN < VCCIO
10
µA
Maximum
Units
0.9 × VCCIO
–10
Table 35. CTT I/O Specifications
Symbol
Parameter
Conditions
Minimum
Typical
VCCIO
I/O supply voltage
3.0
3.3
3.6
V
VTT/VREF (3)
Termination and
reference voltage
1.35
1.5
1.65
V
VIH
High-level input
voltage
VIL
Low-level input
voltage
II
Input pin leakage
current
0 < VIN < VCCIO
–10
VOH
High-level output
voltage
IOH = –8 mA (1)
VREF + 0.4
VOL
Low-level output
voltage
IOL = 8 mA (2)
IO
GND ≤ VOUT ≤ VCCIO
Output leakage
current (when output
is high Z)
VREF + 0.2
–10
V
VREF – 0.2
V
10
µA
V
VREF – 0.4
V
10
µA
Notes to Tables 21 through 35:
(1)
(2)
(3)
The IOH parameter refers to high-level output current.
The IOL parameter refers to low-level output current. This parameter applies to open-drain pins as well as output
pins.
VREF specifies center point of switching range.
Figure 31 shows the output drive characteristics of APEX 20KC devices.
Altera Corporation
63
APEX 20KC Programmable Logic Device Data Sheet
Figure 31. Output Drive Characteristics of APEX 20KC Devices
Note (1)
60
120
110
55
IOL
100
IOL
50
90
45
VCCINT = 1.8 V
VCCIO = 3.3 V
80
Typical IO
70
Output
Current (mA) 60
Room Temperature
VCCINT = 1.8 V
VCCIO = 2.5V
40
Typical IO
35
Output
Current (mA) 30
50
25
40
20
30
Room Temperature
15
IOH
20
IOH
10
10
5
0.5
1
1.5
2
0.5
3
2.5
1
1.5
2
2.5
3
Vo Output Voltage (V)
Vo Output Voltage (V)
26
IOL
24
22
20
18
Typical IO
16
Output
Current (mA) 14
VCCINT = 1.8V
VCCIO = 1.8V
Room Temperature
12
10
8
6
IOH
4
2
0.5
1
1.5
2.0
Vo Output Voltage (V)
Note to Figure 31:
(1)
64
These are transient (AC) currents.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Timing Model
The high-performance FastTrack and MegaLAB interconnect routing
resources ensure predictable performance, accurate simulation, and
accurate timing analysis. This predictable performance contrasts with that
of FPGAs, which use a segmented connection scheme and therefore have
unpredictable performance.
Figure 32 shows the fMAX timing model for APEX 20KC devices.
Figure 32. fMAX Timing Model
LE
t
SU
Routing Delay
tH
t
t
CO
t
LUT
t
t
F1—4
F5—20
F20+
ESB
t
t
t
t
t
t
t
t
t
ESBARC
ESBSRC
ESBAWC
ESBSWC
ESBWASU
ESBWDSU
ESBSRASU
ESBWESU
ESBDATASU
t
ESBWADDRSU
t
ESBRADDRSU
t
ESBDATACO1
t
ESBDATACO2
t
ESBDD
t
PD
t
PTERMSU
t
PTERMCO
Figures 33 and 34 show the asynchronous and synchronous
timingwaveforms, respectively, for the ESB macroparameters in Table 37.
Altera Corporation
65
APEX 20KC Programmable Logic Device Data Sheet
Figure 33. ESB Asynchronous Timing Waveforms
ESB Asynchronous Read
RE
a1
a0
Rdaddress
a2
a3
tESBARC
Data-Out
d0
d1
d3
d2
ESB Asynchronous Write
WE
tESBWP
tESBWDSU
din0
Data-In
tESBWDH
din1
tESBWASU
tESBWAH
tESBWCCOMB
Wraddress
a0
a1
a2
tESBDD
Data-Out
66
din0
din1
dout2
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 34. ESB Synchronous Timing Waveforms
ESB Synchronous Read
WE
Rdaddress
a0
a1
tESBDATASU
a2
a3
tESBARC
tESBDATAH
CLK
tESBDATACO2
Data-Out
d1
d3
d2
ESB Synchronous Write (ESB Output Registers Used)
WE
Data-In
Wraddress
a0
din1
din2
a1
a2
tESBWESU
tESBDATASU
din3
a3
tESBDATAH
a2
tESBWEH
CLK
tESBDATACO1
tESBSWC
Data-Out
dout0
dout1
din1
din2
din3
din2
Figure 35 shows the timing model for bidirectional I/O pin timing.
Altera Corporation
67
APEX 20KC Programmable Logic Device Data Sheet
Figure 35. Synchronous Bidirectional Pin External Timing
OE Register (1)
D
Dedicated
Clock
PRN
Q
CLRN
tXZBIDIR
tZXBIDIR
tOUTCOBIDIR
Output IOE Register
D
PRN
Q
CLRN
Bidirectional Pin
tINSUBIDIR
tINHBIDIR
Input Register (1), (2)
PRN
D
Q
CLRN
Notes to Figure 35:
(1)
The output enable and input registers are LE registers in the LAB adjacent to the
bidirectional pin. Use the “Output Enable Routing = Single-Pin” option in the
Quartus II software to set the output enable register.
(2)
Use the “Decrease Input Delay to Internal Cells = OFF” option in the Quartus II
software to set the LAB-adjacent input register. This maintains a zero hold time for
LAB-adjacent registers while giving a fast, position-independent setup time. Set
“Decrease Input Delay to Internal Cells = ON” and move the input register farther
away from the bidirectional pin for a faster setup time with zero hold time. The
exact position where zero hold occurs with the minimum setup time varies with
device density and speed grade.
Tables 36 to 38 describes the fMAX timing parameters shown in Figure 32.
Table 39 describes the functional timing parameters.
Table 36. APEX 20KC fMAX LE Timing Parameters
Symbol
Parameter
tSU
LE register setup time before clock
tH
LE register hold time before clock
tCO
LE register clock-to-output delay
tLUT
LUT delay for data-in to data-out
68
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 37. APEX 20KC fMAX ESB Timing Parameters
Symbol
Parameter
tESBARC
ESB asynchronous read cycle time
tESBSRC
ESB synchronous read cycle time
tESBAWC
ESB asynchronous write cycle time
tESBSWC
ESB synchronous write cycle time
tESBWASU
ESB write address setup time with respect to WE
tESBWAH
ESB write address hold time with respect to WE
tESBWDSU
ESB data setup time with respect to WE
tESBWDH
ESB data hold time with respect to WE
tESBRASU
ESB read address setup time with respect to RE
tESBRAH
ESB read address hold time with respect to RE
tESBWESU
ESB WE setup time before clock when using input register
tESBDATASU
ESB data setup time before clock when using input register
tESBWADDRSU
ESB write address setup time before clock when using input registers
tESBRADDRSU
ESB read address setup time before clock when using input registers
tESBDATACO1
ESB clock-to-output delay when using output registers
tESBDATACO2
ESB clock-to-output delay without output registers
tESBDD
ESB data-in to data-out delay for RAM mode
tPD
ESB macrocell input to non-registered output
tPTERMSU
ESB macrocell register setup time before clock
tPTERMCO
ESB macrocell register clock-to-output delay
Table 38. APEX 20KC fMAX Routing Delays
Symbol
Parameter
tF1-4
Fan-out delay estimate using local interconnect
tF5-20
Fan-out delay estimate using MegaLab interconnect
tF20+
Fan-out delay estimate using FastTrack interconnect
Altera Corporation
69
APEX 20KC Programmable Logic Device Data Sheet
Table 39. APEX 20KC Minimum Pulse Width Timing Parameters
Symbol
Parameter
tCH
Minimum clock high time from clock pin
tCL
Minimum clock low time from clock pin
tCLRP
LE clear pulse width
tPREP
LE preset pulse width
tESBCH
Clock high time
tESBCL
Clock low time
tESBWP
Write pulse width
tESBRP
Read pulse width
Tables 40 and 41 describe APEX 20KC external timing parameters. The
timing values for these pin-to-pin delays are reported for all pins using the
3.3-V LVTTL I/O standard.
Table 40. APEX 20KC External Timing Parameters
Symbol
Note (1)
Clock Parameter
tINSU
Setup time with global clock at IOE register
tINH
Hold time with global clock at IOE register
tOUTCO
Clock-to-output delay with global clock at IOE output register
tINSUPLL
Setup time with PLL clock at IOE input register
tINHPLL
Hold time with PLL clock at IOE input register
tOUTCOPLL
Clock-to-output delay with PLL clock at IOE output register
70
Conditions
(2)
(2)
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 41. APEX 20KC External Bidirectional Timing Parameters
Symbol
Note (1)
Parameter
Condition
tINSUBIDIR
Setup time for bidirectional pins with global clock at LAB-adjacent input
register
tINHBIDIR
Hold time for bidirectional pins with global clock at LAB-adjacent input
register
tOUTCOBIDIR
Clock-to-output delay for bidirectional pins with global clock at IOE
register
(2)
tXZBIDIR
Synchronous output enable register to output buffer disable delay
(2)
tZXBIDIR
Synchronous output enable register to output buffer enable delay
(2)
tINSUBIDIRPLL
Setup time for bidirectional pins with PLL clock at LAB-adjacent input
register
tINHBIDIRPLL
Hold time for bidirectional pins with PLL clock at LAB-adjacent input
register
tOUTCOBIDIRPLL
Clock-to-output delay for bidirectional pins with PLL clock at IOE register (2)
tXZBIDIRPLL
Synchronous output enable register to output buffer disable delay with
PLL
(2)
tZXBIDIRPLL
Synchronous output enable register to output buffer enable delay with
PLL
(2)
Notes to Tables 40 and 41:
(1)
(2)
These timing parameters are sample-tested only.
For more information, refer to Table 43.
Tables 42 and 43 define the timing delays for each I/O standard. Some
output standards require test load circuits for AC timing measurements as
shown in Figures 36 through 38.
Table 42. APEX 20KC Selectable I/O Standard Input Adder Delays (Part 1 of 2)
Symbol
Parameter
LVCMOS
Input adder delay for the LVCMOS I/O standard
LVTTL
Input adder delay for the LVTTL I/O standard
2.5 V
Input adder delay for the 2.5-V I/O standard
1.8 V
Input adder delay for the 1.8-V I/O standard
PCI
Input adder delay for the PCI I/O standard
GTl+
Input adder delay for the GTL+ I/O standard
SSTL-3 Class I
Input adder delay for the SSTL-3 Class I I/O standard
SSTL-3 Class II
Input adder delay for the SSTL-3 Class II I/O standard
SSTL-2 Class I
Input adder delay for the SSTL -2 Class I I/O standard
SSTL-2 Class II
Input adder delay for the SSTL -2 Class II I/O standard
Altera Corporation
Note (1)
Condition
71
APEX 20KC Programmable Logic Device Data Sheet
Table 42. APEX 20KC Selectable I/O Standard Input Adder Delays (Part 2 of 2)
Symbol
LVDS
Parameter
Note (1)
Condition
Input adder delay for the LVDS I/O standard
CTT
Input adder delay for the CTT I/O standard
AGP
Input adder delay for the AGP I/O standard
Table 43. APEX 20KC Selectable I/O Standard Output Adder Delays
Symbol
Note (1)
Parameter
Condition
LVCMOS
Output adder delay for the LVCMOS I/O standard
LVTTL
Output adder delay for the LVTTL I/O standard
Cload = 35 pF
Rup = 564.5 Ω
Rdn = 430 Ω (2)
2.5 V
Output adder delay for the 2.5-V I/O standard
Cload = 35 pF
Rup = 450 Ω
Rdn = 450 Ω (2)
1.8 V
Output adder delay for the 1.8-V I/O standard
Cload = 35 pF
Rup = 520 Ω
Rdn = 480 Ω (2)
PCI
Output adder delay for the PCI I/O standard
Cload = 10 pF
Rup = 1M Ω
Rdn = 25 Ω (2)
GTl+
Output adder delay for the GTL+ I/O standard
Cload = 30 pF
Rup = 25 Ω (2)
SSTL-3 Class I
Output adder delay for the SSTL-3 Class I I/O standard Cload1 = 0 pF
Cload2 = 30 pF
R = 25 Ω (2)
SSTL-3 Class II
Output adder delay for the SSTL-3 Class II I/O standard Cload1 = 0 pF
Cload2 = 30 pF
R = 25 Ω (2)
SSTL-2 Class I
Output adder delay for the SSTL-2 Class I I/O standard
SSTL-2 Class II
Output adder delay for the SSTL-2 Class II I/O standard
LVDS
Output adder delay for the LVDS I/O standard
CTT
Output adder delay for the CTT I/O standard
AGP
Output adder delay for the AGP I/O standard
Cload = 4 pF
R=100 Ω (2)
Note to Tables 42 and 43:
(1)
(2)
72
These delays report the differences in delays for different I/O standards. Add the delay for the I/O standard that
is used to the external timing parameters.
See Figure 36 for more information.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Figure 36. AC Test Conditions for LVTTL, 2.5 V, 1.8 V, PCI & GTL+ I/O Standards
VCCIO
Rup
Ouptut pin
Cload
Rdn
Figure 37. AC Test Conditions for SSTL-3 Class I & II I/O Standards
VCCIO
R
R
Output pin
Cload2
Cload1
Figure 38. AC Test Conditions for the LVDS I/O Standard
Positive
Output pin
R
Cload
Negative
Output pin
Altera Corporation
73
APEX 20KC Programmable Logic Device Data Sheet
Tables 44 through 67 show the fMAX and external timing parameters for
EPC20K200C, EP20K400C, EP20K600C, and EP20K1000C devices.
Table 44. EP20K200C fMAX LE Timing Microparameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tSU
0.01
0.01
0.01
ns
tH
0.10
0.10
0.10
ns
tCO
0.27
0.30
0.32
ns
tLUT
0.65
0.78
0.92
ns
Table 45. EP20K200C fMAX ESB Timing Microparameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tESBARC
1.30
1.51
1.69
ns
tESBSRC
2.35
2.49
2.72
ns
tESBAWC
2.92
3.46
3.86
ns
tESBSWC
3.05
3.44
3.85
ns
tESBWASU
0.45
0.50
0.54
ns
tESBWAH
0.44
0.50
0.55
ns
tESBWDSU
0.57
0.63
0.68
ns
tESBWDH
0.44
0.50
0.55
ns
tESBRASU
1.25
1.43
1.56
ns
tESBRAH
0.00
0.03
0.11
ns
tESBWESU
0.00
0.00
0.00
ns
tESBDATASU
2.01
2.27
2.45
ns
tESBWADDRSU
–0.20
–0.24
–0.28
ns
tESBRADDRSU
0.02
0.00
–0.02
ns
tESBDATACO1
1.09
1.28
1.43
ns
tESBDATACO2
2.10
2.52
2.82
ns
tESBDD
2.50
2.97
3.32
ns
1.48
tPD
tPTERMSU
tPTERMCO
74
0.58
1.78
0.72
1.10
2.00
0.81
1.29
ns
ns
1.45
ns
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 46. EP20K200C fMAX Routing Delays
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tF1-4
0.15
0.17
0.20
ns
tF5-20
0.81
0.94
1.12
ns
tF20+
0.98
1.13
1.35
ns
Table 47. EP20K200C Minimum Pulse Width Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tCH
1.33
1.66
2.00
ns
tCL
1.33
1.66
2.00
ns
tCLRP
0.20
0.20
0.20
ns
tPREP
0.20
0.20
0.20
ns
tESBCH
1.33
1.66
2.00
ns
tESBCL
1.33
1.66
2.00
ns
tESBWP
1.05
1.28
1.44
ns
tESBRP
0.87
1.06
1.19
ns
Table 48. EP20K200C External Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
tINSU
1.23
1.26
1.33
tINH
0.00
0.00
0.00
tOUTCO
2.00
tINSUPLL
0.81
0.92
-
tINHPLL
0.00
0.00
-
tOUTCOPLL
0.50
Altera Corporation
3.79
2.36
2.00
0.50
4.31
2.62
2.00
-
Unit
Max
ns
ns
4.70
ns
ns
ns
-
ns
75
APEX 20KC Programmable Logic Device Data Sheet
Table 49. EP20K200C External Bidirectional Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
tINSUBIDIR
1.38
1.78
1.99
tINHBIDIR
0.00
0.00
0.00
tOUTCOBIDIR
2.00
3.79
2.00
4.31
2.00
Max
ns
ns
4.70
ns
ns
tXZBIDIR
6.12
6.51
7.89
tZXBIDIR
6.12
6.51
7.89
tINSUBIDIRPLL
2.82
tINHBIDIRPLL
0.00
tOUTCOBIDIRPLL
0.50
3.47
-
0.00
2.36
0.50
-
ns
ns
2.62
Unit
ns
-
ns
tXZBIDIRPLL
4.69
4.82
-
ns
tZXBIDIRPLL
4.69
4.82
-
ns
Table 50. EP20K400C fMAX LE Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
tSU
0.01
tH
0.10
Max
Max
0.01
Max
0.01
0.10
Unit
ns
0.10
ns
tCO
0.27
0.30
0.32
ns
tLUT
0.65
0.78
0.92
ns
76
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 51. EP20K400C fMAX ESB Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tESBARC
1.30
1.51
1.69
ns
tESBSRC
2.35
2.49
2.72
ns
tESBAWC
2.92
3.46
3.86
ns
3.85
ns
3.05
tESBSWC
3.44
tESBWASU
0.45
0.50
0.54
ns
tESBWAH
0.44
0.50
0.55
ns
tESBWDSU
0.57
0.63
0.68
ns
tESBWDH
0.44
0.50
0.55
ns
tESBRASU
1.25
1.43
1.56
ns
tESBRAH
0.00
0.03
0.11
ns
tESBWESU
0.00
0.00
0.00
ns
tESBDATASU
2.01
2.27
2.45
ns
tESBWADDRSU
−0.20
−0.24
−0.28
ns
tESBRADDRSU
0.02
0.00
−0.02
ns
tESBDATACO1
1.09
1.28
1.43
ns
tESBDATACO2
2.10
2.52
2.82
ns
tESBDD
2.50
2.97
3.32
ns
tPD
1.48
1.78
2.00
ns
tPTERMSU
0.58
0.72
1.10
tPTERMCO
0.81
1.29
ns
1.45
ns
Table 52. EP20K400C fMAX Routing Delays
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tF1-4
0.15
0.17
0.19
ns
tF5-20
0.94
1.06
1.25
ns
tF20+
1.73
1.96
2.30
ns
Altera Corporation
77
APEX 20KC Programmable Logic Device Data Sheet
Table 53. EP20K400C Minimum Pulse Width Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tCH
1.33
1.66
2.00
ns
tCL
1.33
1.66
2.00
ns
tCLRP
0.20
0.20
0.20
ns
tPREP
0.20
0.20
0.20
ns
tESBCH
1.33
1.66
2.00
ns
tESBCL
1.33
1.66
2.00
ns
tESBWP
1.05
1.28
1.44
ns
tESBRP
0.87
1.06
1.19
ns
Table 54. EP20K400C External Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
Unit
Max
tINSU
1.37
1.52
1.64
ns
tINH
0.00
0.00
0.00
ns
tOUTCO
2.00
tINSUPLL
0.80
0.91
-
tINHPLL
0.00
0.00
-
tOUTCOPLL
0.50
78
4.25
2.27
2.00
0.50
4.61
2.55
2.00
-
5.03
ns
ns
ns
-
ns
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 55. EP20K400C External Bidirectional Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
Unit
Max
tINSUBIDIR
1.29
1.67
1.92
ns
tINHBIDIR
0.00
0.00
0.00
ns
tOUTCOBIDIR
2.00
4.25
2.00
4.61
2.00
5.03
ns
ns
tXZBIDIR
6.55
6.97
7.35
tZXBIDIR
6.55
6.97
7.36
tINSUBIDIRPLL
3.22
tINHBIDIRPLL
0.00
tOUTCOBIDIRPLL
0.50
3.80
-
0.00
2.27
0.50
2.55
-
ns
ns
ns
-
ns
tXZBIDIRPLL
4.62
4.84
-
ns
tZXBIDIRPLL
4.62
4.84
-
ns
Table 56. EP20K600C fMAX LE Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
tSU
0.01
tH
0.10
Max
Max
0.01
Max
0.01
0.10
Unit
ns
0.10
ns
tCO
0.27
0.30
0.32
ns
tLUT
0.65
0.78
0.92
ns
Altera Corporation
79
APEX 20KC Programmable Logic Device Data Sheet
Table 57. EP20K600C fMAX ESB Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tESBARC
1.30
1.51
1.69
ns
tESBSRC
2.35
2.49
2.72
ns
tESBAWC
2.92
3.46
3.86
ns
3.05
tESBSWC
3.44
3.85
ns
tESBWASU
0.45
0.50
0.54
ns
tESBWAH
0.44
0.50
0.55
ns
tESBWDSU
0.57
0.63
0.68
ns
tESBWDH
0.44
0.50
0.55
ns
tESBRASU
1.25
1.43
1.56
ns
tESBRAH
0.00
0.03
0.11
ns
tESBWESU
0.00
0.00
0.00
ns
tESBDATASU
2.01
2.27
2.45
ns
tESBWADDRSU
−0.20
−0.24
−0.28
ns
tESBRADDRSU
0.02
0.00
−0.02
ns
tESBDATACO1
1.09
1.28
1.43
ns
tESBDATACO2
2.10
2.52
2.82
ns
tESBDD
2.50
2.97
3.32
ns
tPD
1.48
1.78
2.00
tPTERMSU
0.58
0.72
1.10
tPTERMCO
0.81
1.29
ns
ns
1.45
ns
Table 58. EP20K600C fMAX Routing Delays
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tF1-4
0.15
0.16
0.18
ns
tF5-20
0.94
1.05
1.20
ns
tF20+
1.76
1.98
2.23
ns
80
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 59. EP20K600C Minimum Pulse Width Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tCH
1.33
1.66
2.00
ns
tCL
1.33
1.66
2.00
ns
tCLRP
0.20
0.20
0.20
ns
tPREP
0.20
0.20
0.20
ns
tESBCH
1.33
1.66
2.00
ns
tESBCL
1.33
1.66
2.00
ns
tESBWP
1.05
1.28
1.44
ns
tESBRP
0.87
1.06
1.19
ns
Table 60. EP20K600C External Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
Unit
Max
tINSU
1.28
1.40
1.45
tINH
0.00
0.00
0.00
tOUTCO
2.00
tINSUPLL
0.80
0.91
-
ns
tINHPLL
0.00
0.00
-
ns
tOUTCOPLL
0.50
Altera Corporation
4.29
2.37
2.00
0.50
4.77
2.63
2.00
-
ns
ns
5.11
-
ns
ns
81
APEX 20KC Programmable Logic Device Data Sheet
Table 61. EP20K600C External Bidirectional Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
Unit
Max
tINSUBIDIR
2.03
2.57
2.97
ns
tINHBIDIR
0.00
0.00
0.00
ns
tOUTCOBIDIR
2.00
4.29
2.00
4.77
2.00
5.11
ns
ns
tXZBIDIR
8.31
9.14
9.76
tZXBIDIR
8.31
9.14
9.76
tINSUBIDIRPLL
3.99
tINHBIDIRPLL
0.00
tOUTCOBIDIRPLL
0.50
4.77
-
0.00
2.37
0.50
2.63
-
ns
ns
ns
-
ns
tXZBIDIRPLL
6.35
6.94
-
ns
tZXBIDIRPLL
6.35
6.94
-
ns
Table 62. EP20K1000C fMAX LE Timing Microparameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
tSU
0.01
tH
0.10
Max
Max
0.01
Max
0.01
0.10
Unit
ns
0.10
ns
tCO
0.27
0.30
0.32
ns
tLUT
0.66
0.79
0.92
ns
82
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 63. EP20K1000C fMAX ESB Timing Microparameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tESBARC
1.48
1.57
1.65
ns
tESBSRC
2.36
2.50
2.73
ns
tESBAWC
2.93
3.46
3.86
ns
3.83
ns
3.08
tESBSWC
3.43
tESBWASU
0.51
0.50
0.52
ns
tESBWAH
0.38
0.51
0.57
ns
tESBWDSU
0.62
0.62
0.66
ns
tESBWDH
0.38
0.51
0.57
ns
tESBRASU
1.40
1.47
1.53
ns
tESBRAH
0.00
0.07
0.18
ns
tESBWESU
0.00
0.00
0.00
ns
tESBDATASU
1.92
2.19
2.35
ns
tESBWADDRSU
–0.20
–0.28
–0.32
ns
tESBRADDRSU
0.00
–0.03
–0.05
ns
tESBDATACO1
1.12
1.30
1.46
ns
tESBDATACO2
2.11
2.53
2.84
ns
tESBDD
2.56
2.96
3.30
ns
tPD
1.49
1.79
2.02
ns
tPTERMSU
0.61
0.69
1.13
tPTERMCO
0.77
1.32
ns
1.48
ns
Table 64. EP20K1000C fMAX Routing Delays
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tF1-4
0.15
0.17
0.19
ns
tF5-20
1.13
1.31
1.50
ns
tF20+
2.30
2.71
3.19
ns
Altera Corporation
83
APEX 20KC Programmable Logic Device Data Sheet
Table 65. EP20K1000C Minimum Pulse Width Timing Parameters
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Min
Min
Min
Max
Max
Unit
Max
tCH
1.33
1.66
2.00
ns
tCL
1.33
1.66
2.00
ns
tCLRP
0.20
0.20
0.20
ns
tPREP
0.20
0.20
0.20
ns
tESBCH
1.33
1.66
2.00
ns
tESBCL
1.33
1.66
2.00
ns
tESBWP
1.04
1.26
1.41
ns
tESBRP
0.87
1.05
1.18
ns
Table 66. EP20K1000C External Timing Parameters
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grade
Min
Max
-9 Speed Grade
Min
Unit
Max
tINSU
1.14
1.14
1.11
tINH
0.00
0.00
0.00
tOUTCO
2.00
tINSUPLL
0.81
0.92
-
ns
tINHPLL
0.00
0.00
-
ns
tOUTCOPLL
0.50
84
4.63
2.32
2.00
0.50
5.26
2.55
2.00
-
ns
ns
5.69
-
ns
ns
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Table 67. EP20K1000C External Bidirectional Timing Parameters
Symbol
-7 Speed Grade
Min
-8 Speed Grade
Max
Min
Max
-9 Speed Grade
Min
tINSUBIDIR
1.86
2.54
3.15
tINHBIDIR
0.00
0.00
0.00
tOUTCOBIDIR
2.00
4.63
2.00
5.26
2.00
Max
ns
ns
5.69
ns
ns
tXZBIDIR
8.98
9.89
10.67
tZXBIDIR
8.98
9.89
10.67
tINSUBIDIRPLL
4.17
tINHBIDIRPLL
0.00
tOUTCOBIDIRPLL
0.50
5.27
-
0.00
2.32
0.50
ns
ns
2.55
Unit
ns
-
-
ns
tXZBIDIRPLL
6.67
7.18
-
ns
tZXBIDIRPLL
6.67
7.18
-
ns
Tables 68 and 69 show selectable I/O standard input and output delays
for APEX 20KC devices. If you select an I/O standard input or output
delay other than LVCMOS, add the delay for the selected speed grade to
the LVCMOS value.
Table 68. Selectable I/O Standard Input Delays
Symbol
-7 Speed Grade
-8 Speed Grade
-9 Speed Grade
Unit
Min
Min
Min
Min
Max
Max
Max
LVCMOS
0.00
0.00
0.00
ns
LVTTL
0.00
0.00
0.00
ns
2.5 V
0.00
0.00
0.00
ns
1.8 V
0.04
0.11
0.14
ns
PCI
0.00
0.04
0.03
ns
GTL+
–0.30
0.25
0.23
ns
SSTL-3 Class I
–0.19
–0.13
–0.13
ns
SSTL-3 Class II
–0.19
–0.13
–0.13
ns
SSTL-2 Class I
–0.19
–0.13
–0.13
ns
SSTL-2 Class II
–0.19
–0.13
–0.13
ns
LVDS
–0.19
–0.17
–0.16
ns
CTT
0.00
0.00
0.00
ns
AGP
0.00
0.00
0.00
ns
Altera Corporation
85
APEX 20KC Programmable Logic Device Data Sheet
Table 69. Selectable I/O Standard Output Delays
Symbol
-7 Speed Grade
Min
Max
-8 Speed Grad
Min
Max
-9 Speed Grade
Unit
Min
Min
Max
LVCMOS
0.00
0.00
0.00
ns
LVTTL
0.00
0.00
0.00
ns
2.5 V
0.00
0.00
0.00
ns
ns
1.8 V
1.18
1.41
1.57
PCI
–0.52
–0.53
–0.56
ns
GTL+
–0.18
–0.29
–0.39
ns
SSTL-3 Class I
–0.67
–0.71
–0.75
ns
SSTL-3 Class II
–0.67
–0.71
–0.75
ns
SSTL-2 Class I
–0.67
–0.71
–0.75
ns
SSTL-2 Class II
–0.67
–0.71
–0.75
ns
LVDS
–0.69
–0.70
–0.73
ns
CTT
0.00
0.00
0.00
ns
AGP
0.00
0.00
0.00
ns
Power
Consumption
To estimate device power consumption, use the interactive power
estimator on the Altera web site at http://www.altera.com.
Configuration &
Operation
The APEX 20KC architecture supports several configuration schemes.
This section summarizes the device operating modes and available device
configuration schemes.
Operating Modes
The APEX architecture uses SRAM configuration elements that require
configuration data to be loaded each time the circuit powers up. The
process of physically loading the SRAM data into the device is called
configuration. During initialization, which occurs immediately after
configuration, the device resets registers, enables I/O pins, and begins to
operate as a logic device. The I/O pins are tri-stated during power-up,
and before and during configuration. Together, the configuration and
initialization processes are called command mode; normal device operation
is called user mode.
Before and during device configuration, all I/O pins are pulled to VCCIO
by a built-in weak pull-up resistor.
86
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
SRAM configuration elements allow APEX 20KC devices to be
reconfigured in-circuit by loading new configuration data into the device.
Real-time reconfiguration is performed by forcing the device into
command mode with a device pin, loading different configuration data,
reinitializing the device, and resuming user-mode operation. In-field
upgrades can be performed by distributing new configuration files.
Configuration Schemes
The configuration data for an APEX 20KC device can be loaded with one
of five configuration schemes (see Table 70), chosen on the basis of the
target application. An EPC16, EPC2, or EPC1 configuration device,
intelligent controller, or the JTAG port can be used to control the
configuration of an APEX 20KC device. When a configuration device is
used, the system can configure automatically at system power-up.
Multiple APEX 20KC devices can be configured in any of five
configuration schemes by connecting the configuration enable (nCE) and
configuration enable output (nCEO) pins on each device.
Table 70. Data Sources for Configuration
Configuration Scheme
Data Source
Configuration device
EPC16, EPC8, EPC4, EPC2, or EPC1 configuration device
Passive serial (PS)
MasterBlaster or ByteBlasterMV download cable or serial data source
Passive parallel asynchronous (PPA)
Parallel data source
Passive parallel synchronous (PPS)
Parallel data source
JTAG
MasterBlaster or ByteBlasterMV download cable or a microprocessor
with a Jam Standard Test and Programming Language (STAPL) or
JBC File
f
For more information on configuration, see Application Note 116
(Configuring SRAM-Based LUT Devices).
Device PinOuts
See the Altera web site (http://www.altera.com) or the Altera Digital
Library for pin-out information.
Ordering
Information
Figure 39 describes the ordering codes for Stratix devices. For more
information on a specific package, refer to the Altera Device Package
Information Data Sheet.
Altera Corporation
87
APEX 20KC Programmable Logic Device Data Sheet
Figure 39. APEX 20KC Device Packaging Ordering Information
EP20K
1000C
F
1020
C
7
ES
Family Signature
Optional Suffix
Indicates specific device options or
shipment method.
ES: Engineering sample
EP20K: APEX 20K
Device Type
200C
400C
600C
1000C
Speed Grade
7, 8, or 9, with 7 being the fastest
Operating Temperature
Package Type
Q: Plastic quad flat package (PQFP)
B: Ball-grid array (BGA)
F: FineLine BGA
Pin Count
C: Commercial temperature (tJ = 0˚ C to 85˚ C)
I: Industrial temperature (tJ = -40˚ C to 100˚ C)
Number of pins for a particular package
Revision
History
The information contained in the APEX 20KC Programmable Logic Device
Data Sheet version 2.2 supersedes information published in previous
versions.
Version 2.2
The following changes were made to the APEX 20KC Programmable Logic
Device Data Sheet version 2.2:
■
■
Updated Tables 1.
Updated notes in Tables 20.
Version 2.1
The following changes were made to the APEX 20KC Programmable Logic
Device Data Sheet version 2.1:
■
■
■
■
■
■
■
■
■
88
Removed figure on AC Test Conditions.
Updated conditions in Tables 40 and 41.
Added Tables 42 and 43.
Updated VOD in Table 27.
Added Figures 36 through 38.
Updated Tables 44 through 49.
Updated Tables 62 through 67.
Removed notes in Tables 44 through 67.
Various textual changes throughout the document.
Altera Corporation
APEX 20KC Programmable Logic Device Data Sheet
Altera Corporation
89
APEX 20KC Programmable Logic Device Data Sheet
®
101 Innovation Drive
San Jose, CA 95134
(408) 544-7000
http://www.altera.com
Applications Hotline:
(800) 800-EPLD
Customer Marketing:
(408) 544-7104
Literature Services:
[email protected]
90
Copyright © 2002 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the
stylized Altera logo, specific device designations, and all other words and logos that are identified as
trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera
Corporation in the U.S. and other countries. All other product or service names are the property of their
respective holders. Altera products are protected under numerous U.S. and foreign patents and pending
applications, mask work rights, and copyrights. Altera warrants performance of its semiconductor products
to current specifications in accordance with Altera’s standard warranty, but reserves the
right to make changes to any products and services at any time without notice. Altera
assumes no responsibility or liability arising out of the application or use of any
information, product, or service described herein except as expressly agreed to in writing
by Altera Corporation. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for
products or services.
Altera Corporation