Transformer EPA3818 ELECTRONICS INC. • Thru Hole Package • • 500 Vrms Isolation • Electrical Parameters @ 25° C Primary Inductance (mH Min.) Leakage Inductance (µH Max.) Interwinding Capacitance (pF Max.) Turns Ratio (± 5%) Primary DCR (Ω Max.) (each Wdg) 5.0 1.3 60 1:1:1 3.9 Schematic Package 11 11 9 7 12 10 8 5 3 1 6 4 2 12 PCA EPA3818 D.C. 1• Dimensions B 2 Dim. A B C D E F G H I A C E Min. .480 .380 .480 --.075 ----.017 .120 (Inches) Max. Nom. .500 .400 .500 --.085 ----.023 .140 .490 .390 .490 .250 .080 .50 .400 .020 .130 (Milimeters) Min. Max. Nom. 12.19 9.65 12.19 --1.91 ----.440 3.05 12.70 10.16 12.70 --2.16 ----.580 3.56 12.45 9.91 12.45 6.35 2.03 1.27 10.16 .508 3.30 I G H PCA ELECTRONICS, INC. 16799 SCHOENBORN ST. NORTH HILLS, CA 91343 F D CSA3818 Rev. - 10/24/01 Product performance is limited to specified parameters. Data is subject to change without prior notice. TEL: (818) 892-0761 FAX: (818) 894-5791 http://www.pca.com