PCA EPC3089-9

Off-Line PC Mount Transformer
EPC3089-X
ELECTRONICS INC.
• Single Primary : 115 V
• Split Bobbin Construction
• UL 94V-0 Recognized Components
• UL 1446 Class B Insulation System
• Meets or exceeds CSA/TUV/VDE Specifications
for Creepage, Clearance and Dielectric Strength
Electrical Parameters @ 25° C
Part
Number
Primary
Voltage
EPC3089-1
EPC3089-2
EPC3089-3
EPC3089-4
EPC3089-5
EPC3089-6
EPC3089-7
EPC3089-8
EPC3089-9
EPC3089-10
115
115
115
115
115
115
115
115
115
115
Secondary Voltage
Parallel
Series
Connection
Connection
Secondary Current (A-Rms)
Parallel
Series
Connection
Connection
0.11
.090
0.70
0.55
0.45
0.04
0.03
0.023
0.02
0.01
0.22
10
5.0
0.58
12.6
6.3
0.14
16
8.0
0.11
20
10
0.09
24
12
0.08
28
14
0.06
36
18
0.046
48
24
0.04
56
28
0.02
120
60
• Switching Frequency : 50 Hz - 500 Hz • Isolation : 2500 Vrms •
Package
1.370
(34.90)
Power
Rating
(VA)
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
Schematic
1.120
(28.60)
.930
(23.80)
Pri.
Sec.
5
4
6
1
7
8
.280
(7.11)
.250
(6.35)
.041(1.04)
1.200
(30.50)
.250
(6.35)
.750
(19.05)
1
4
Notes :
1. Optional Mounting Screws and Nut : None
2. Pins 2 and 3 omitted
5
6
7
8
Clearance
Hole
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSC3089-X
Rev. -
7/15/02
TEL: (818) 892-0761
FAX: (818) 894-5791
http://www.pca.com