LINEAGEPOWER EUK240S9R041Z

Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC Converters
36-60 Vdc Input; 9.6V Output; 240 W
Features
RoHS Compliant
ƒ
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
ƒ
Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
ƒ
High efficiency – 96% at 9.6V, full load
ƒ
Excellent Thermal Performance:
240W at Vin=55Vdc, 55ºC at 1m/s (200LFM)
240W at Vin=60Vdc, 60ºC at 1.5m/s (300LFM)
ƒ
Industry standard Eighth brick:
57.9 mm x 23.6mm x 11.0 mm
(2.28 in x 0.93 in x 0.44 in)
ƒ
Cost-efficient open frame design
Applications
ƒ
Low output voltage ripple and noise
ƒ
Distributed Power Architecture
ƒ
Positive Remote On/Off logic
ƒ
Wireless Networks
ƒ
Output over-current protection, auto-restart
ƒ
Optical and Access Networks equipment
ƒ
Input over-voltage protection, auto-restart
ƒ
Enterprise Networks
ƒ
Input under-voltage lockout
ƒ
Over-temperature protection, auto-restart
ƒ
Operating temperature range (-40°C to 85°C)
ƒ
ISO** 9001 certified manufacturing facilities
ƒ
Basic Insulation (100% factory test to 1500Vdc)
ƒ
UL* 60950-1 Recognised, CSA† C22.2 No. 60950‡
1-03 Certified, and EN 60950-1 (VDE 0805: 200112) Licensed
Options
ƒ
Negative logic, Remote On/Off
ƒ
Pin length
Description
The EUK240-series DC-DC converters are single-output power modules designed to support intermediate bus
applications using discrete/modular point of load (POL) converters. The output is unregulated and a fixed 5:1 ratio is
maintained between the input and output voltages. By taking advantage of the absence of regulation, high efficiency
topologies operated at fixed duty cycles can be employed leading to low cost open frame modules. The output is
fully isolated from the input, allowing versatile polarity configurations and grounding connections. The high efficiency
of this converter leads to lower power dissipation. Built-in filtering for both input and output minimizes the need for
external filtering. The module package dimensions are 59.7 mm x 23.6 mm x 11.0 mm (2.28 in x 0.93 in x 0.44 in.).
Standard features include remote On/Off, input over-voltage, output over-current and over-temperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
‡
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS06-113 ver. 1.03
PDF name: euk240_series_ds.pdf
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Continuous
All
VIN
-0.3
60
Vdc
Non-Operating Condition
All
-0.3
75
Vdc
Input Voltage
Operating Ambient Temperature
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage (100% factory tested)
All
Viso
⎯
1500
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
60
Vdc
All
IIN,max
5
Adc
Inrush Transient
All
2
1
As
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance;
o
Ta 25 C, Cin = 33 µF)
All
⎯
50
⎯
mAp-p
Input Ripple Rejection (120Hz)
All
⎯
14
⎯
dB
Operating Input Voltage
Maximum Input Current
(VIN=0 to 60Vdc, PO=PO, max )
It
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fastacting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER
2
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
All
VO, set
All
VO
Min
Typ
Max
9.6
Unit
Vdc
(VIN = VIN, min, IO = IO, max, TA =25°C)
Output Voltage
⎯
6.0
12.0
Vdc
(Over all line, load, and
Temp Conditions Until end of life)
Output Regulation
Line (VIN = VIN, min to VIN, max)
All
⎯
4.2
V
Load (IO = IO, min to IO, max)
All
⎯
⎯
500
mV
Temperature (Tref =TA, min to TA, max)
All
⎯
⎯
200
mV
RMS (5Hz to 20MHz bandwidth)
All
⎯
33
65
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
⎯
100
150
mVpk-pk
0
⎯
5000
μF
240
W
34
A dc
Output Ripple and Noise on nominal output
(VIN =VIN, nom and IO = IO, min to IO, max,
Cout = 1μF ceramic // 10μF Tantalum capacitor)
External Capacitance
All
Output Power
CO,max
Po
Output Current
All
Io
0
⎯
Output Current Limit Inception (Hiccup Mode)
All
IO, lim
⎯
32
Efficiency
All
η
⎯
96
All
fsw
130
Peak Deviation
All
Vpk
⎯
Settling Time (Vo<10% peak deviation)
All
ts
⎯
Peak Deviation
All
Vpk
Settling Time (Vo<10% peak deviation)
All
ts
A dc
⎯
%
240
KHz
400
⎯
mV
0.2
⎯
ms
⎯
400
⎯
mV
⎯
0.2
⎯
ms
VIN= 48V, TA=25°C, IO= IO, max
Switching Frequency
Dynamic Load Response
(dIo/dt= 0.1A /μs; VIN = VIN, nom; TA=25°C)
Load Change from Io= 50% to 75% of Io,max
Load Change from Io= 50% to 25% of Io,max
Isolation Specifications
Parameter
Min
Typ
Max
Unit
Isolation Capacitance
⎯
1000
⎯
pF
Isolation Resistance
10
⎯
⎯
MΩ
General Specifications
Parameter
Min
Calculated MTBF (IO= 80% of IO, max, TA=40°C)
Weight
LINEAGE POWER
⎯
Typ
Max
Unit
2,511,340
⎯
Hours
32.5 (1.15)
⎯
g (oz.)
3
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
All
All
Ion/off
Von/off
Von/off
⎯
-0.3
2.0
⎯
⎯
⎯
1.0
0.8
4.7
mA
Vdc
Vdc
All
Ion/off
⎯
⎯
0.7
mA
Von/off
⎯
⎯
13.5
Vdc
All
Tdelay
―
10
―
msec
All
Tdelay
―
8
―
msec
All
Trise
―
5
―
msec
―
―
400
mV
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
Logic Low - On/Off Voltage
Logic High Voltage – (Typ = Open Collector)
Logic High maximum allowable leakage current
(Von/off = 2.0V)
Maximum voltage allowed on On/Off pin
Turn-On Delay and Rise Times
o
(IO=80 % IO, max , TA = 25 C)
Case 1: On/Off input is set to Logic High and then
input power is applied (delay from instant at which VIN
= VIN, min until Vo =10% of Vo,nom)
Case 2: Input power is applied for at least one second
and then the On/Off input is set to logic high (delay
from instant at which Von/Off = 0.9V until Vo=10% of
Vo, set)
Output voltage Rise time (time for Vo to rise from 10%
Of Vo, nom to 90% of Vo, nom)
Output voltage overshoot – Startup
o
IO= 80% of IO, max; TA = 25 C
Input Under-voltage Lockout
All
All
VUVLO
Turn-on Threshold
―
34
35.5
V
Turn-off Threshold
32.0
35
―
V
―
63
65
Input Over voltage Protection
Over temperature protection
LINEAGE POWER
All
All
VI, prot
―
125
―
V
0
C
4
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Characteristic Curves
The following figures provide typical characteristics for EUK240S9R0 at TA = 25O C
ON/OFF VOLTAGE
VO (V) (5V/div)
4
Io = 20.5A
3
Io = 0A
0
40
45
50
55
INPUT VOLTAGE, VIN (V)
60
Figure 1. Typical Input characteristics at room
temperature .
OUTPUT VOLTAGE
100
Vin = 36V
EFFICIENCY, η (%)
95
90
Vin = 48V
85
Vin = 60V
80
75
70
0
5
10
15
20
25
30
TIME, t (5 ms/div)
Figure 4. Typical Start-Up Characteristics from
Remote ON/OFF.
35
OUTPUT CURRENT, IO (A)
Figure 2. Typical Converter Efficiency versus
Output Current at room temperature.
VO (V) (200 mV/div)
35
IO (A) (5A/div)
30
VOn/off (V) (2V/div)
Io = 10.25A
1
OUTPUT VOLTAGE
2
OUTPUT CURRENT
INPUT CURRENT, IIN (A)
5
Figure 5. Transient Response to a Dynamic Load
Change from 50% to 75% 50% of full load.
Vin = 60V
8
OUTPUT VOLTAGE, VO (V)
VO (V) (50mV/div)
OUTPUT RIPPLE VOLTAGE
Vin = 36V
Vin = 48V
TIME, t (20 μs/div)
7
6
Io = 0A
5
4
Io = 10.25A
3
2
Io = 20.5A
1
0
33
TIME, t (2 μs/div)
Figure 3. Output ripple voltage at full load and
minimum, nominal and maximum input voltage.
LINEAGE POWER
33.5
34
34.5
35
INPUT VOLTAGE, Vin (V)
Figure 6. Typical Output Voltage start up vs. Input
Voltage Characteristic at Room Temperature.
5
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Characteristic Curves (continued)
The following figures provide typical characteristics for EUK240S9R0 at TA = 25O C
240.0
11
OUTPUT POWER. PO (W)
OUTPUT VOLTAGE, VO (V)
12
Vin = 60V
10
9
Vin = 48V
8
Vin = 36V
7
6
0
5
10
15
20
25
30
220.0
3 m/s (600LFM)
200.0
180.0
2 m/s (400LFM)
160.0
1 m/s (200LFM)
140.0
120.0
100.0
35
20
OUTPUT CURRENT, IO (A)
11
220.0
OUTPUT POWER. PO (W)
OUTPUT VOLTAGE, VO (V)
240.0
10
Io = 20.5A
Io = 10.25A
8
7
6
30
35
40
45
50
55
60
200.0
60
70
80
90
3 m/s (600LFM)
180.0
2 m/s (400LFM)
160.0
1 m/s (200LFM)
140.0
120.0
100.0
65
20
INPUT VOLTAGE, Vin (V)
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 8. Typical Output Voltage vs. Input Voltage
Characteristic at Room Temperature.
Figure 11. Thermal derating of the module in the
Transverse Orientation; Airflow Direction from Vin(-)
to Vin(+); Vin = 55V.
240.0
240.0
OUTPUT POWER. PO (W)
OUTPUT POWER. PO (W)
50
Figure 10. Thermal derating of the module in the
Transverse Orientation; Airflow Direction from Vin(-)
to Vin(+); Vin = 48V.
12
9
40
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 7. Typical Output Voltage vs. Output Current
Characteristic at Room Temperature.
Io = 0A
30
220.0
200.0
3 m/s (600LFM)
180.0
2 m/s (400LFM)
160.0
1 m/s (200LFM)
140.0
120.0
220.0
200.0
2 m/s (400 LFM) &
3 m/s (600 LFM)
180.0
160.0
1.5 m/s (300 LFM)
140.0
1 m/s (200 LFM)
120.0
100.0
100.0
20
30
40
50
60
70
80
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 9. Thermal derating of the module in the
Transverse Orientation; Airflow Direction from Vin(-)
to Vin(+); Vin = 38V.
LINEAGE POWER
90
20
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 12. Thermal derating of the module in the
Transverse Orientation; Airflow Direction from Vin(-)
to Vin(+); Vin = 60V.
6
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Test Configurations
Safety Considerations
For safety agency approval the power module must
be installed in compliance with the spacing and
separation requirements of the end-use safety agency
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-103, and EN60950-1 (VDE 0850) (IEC60950, 3rd
edition) Licensed. The power modules meet the
73/23/EEC and 93/68/EEC Directives and will be
marked with the Conformite Europeane (CE) mark.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements.
Figure 13. Input Reflected Ripple Current Test
Setup.
The input to these units is to be provided with a fastacting fuse with a maximum rating of 15 A in the
ungrounded lead.
Figure 14. Output Ripple and Noise Test Setup.
Figure 15. Output Voltage and Efficiency Test
Setup.
VO. IO
Efficiency
η =
LINEAGE POWER
VIN. IIN
x
100 %
7
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Feature Description
Input Under-voltage Lockout
Remote On/Off
At input voltages below the input under voltage
lockout limit, the module operation is disabled. The
module will begin to operate at an input voltage above
the under voltage lockout turn-on threshold.
Two remote on/off options are available. Positive logic
remote on/off turns the module on during a logic-high
voltage on the ON/OFF pin, and off during logic low.
Negative logic remote on/off turns the module off
during a logic high and on during a logic low. Negative
logic, device code suffix "1," is the factory-preferred
configuration. To turn the power module on and off,
the user must supply a switch to control the voltage
between the on/off terminal and the VI (-) terminal
(Von/off). The switch can be an open collector or
equivalent (see Figure 16). A logic low is Von/off =
-0.3 V to 0.8 V. The maximum Ion/off during a logic
low is 10 mA. The switch should maintain a logic-low
voltage while sinking 10 mA. During logic high, the
maximum Von/off generated by the power module is
4.7 V. The maximum allowable leakage current of the
switch at Von/off = 2.0V is 0.7 mA. If not using the
remote on/off feature, perform one of the following to
turn the unit on:
For negative logic, short ON/OFF pin to VI(-).
For positive logic: leave ON/OFF pin open.
Ion/off
+
ON/OFF
Von/off
–
These modules feature an over-temperature
protection circuit to safeguard against thermal
damage. The protection circuit shuts down the
module when the maximum device reference
temperature is exceeded. When the module cools
down and the reference device temperature falls
below the recovery threshold, the module will resume
operation.
Over-voltage Protection
The input/output over-voltage protection circuit is
designed to shut down the module when the input
voltage exceeds the over-voltage threshold. The
module will resume operation when the input voltage
enters the normal input operating range
Short Circuit Protection
The power modules shall sustain no damage when
subjected to a short circuit of any duration on its
output. The output of the module shall recover
automatically in a hiccup (auto-restart) manner
identical to that described in the over-current
protection section.
Pre-Bias Immunity
VO(+)
LOAD
VI(+)
Over-temperature Protection
VO(–)
VI(–)
Figure 16. Circuit configuration for using Remote
On/Off Implementation.
The startup/shutdown characteristics of the module
accommodates external voltage source clamping on
the output via external diodes without exhibiting nonmonotonic startup (See figure 17). The monotonic
startup of the module will not be affected by the
customer application of the pre-biasing of the output.
During shutdown an internal feature implemented in
the module ensures there will be no reverse current.
During Hiccup operation, the reverse current
protection will be enabled.
Over-current Protection
To provide protection in an output overload condition,
the module is equipped with internal current-limiting
circuitry and can endure current limiting for unlimited
duration. If the output current exceeds the current limit
inception value, the module enters into the hiccup
(auto-restart) mode operation, where it shuts down
and automatically attempts to restart. As long as the
fault condition exists, the module will remain in this
hiccup mode, and can sustain this mode of operation
until the over-current fault condition is corrected.
LINEAGE POWER
Vout
Module
L
O
A
D
Vs
Figure 17. Pre-bias immunity configuration.
8
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data is based on physical measurements
taken in a wind tunnel. The test set-up is shown in
Figure 18. The module delivers full power over an
input voltage range of 36V to 55V, at an ambient
o
temperature of 55 C, at the airflow rate of 200LFM
environment, at sea level, at 50 % relative humidity,
with specified orientation. For higher local ambient
temperature operation, the modules output power
should be derated, as shown in Figures 9 - 12.
Figure 19. Temperature Measurement Locations
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
25.4
(1.0)
Wind Tunnel
PWBs
Power Module
76.2
(3.0)
x
6.55
(0.258)
Probe Location
for measuring
airflow and
ambient
temperature
Air
flow
Figure 18. Thermal Test Set up.
LINEAGE POWER
9
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect
both the reliability of a power module and the
testability of the finished circuit-board assembly. For
guidance on appropriate soldering, cleaning and
drying procedures, refer to Lineage Power Board
Mounted Power Modules: Soldering and Cleaning
Application Note (AP01-056EPS).
Through-Hole Lead-Free Soldering
Information
The RoHS-compliant through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant
components. They are designed to be processed
through single or dual wave soldering machines. The
pins have an RoHS-compliant finish that is compatible
with both Pb and Pb-free wave soldering processes.
A maximum preheat rate of 3°C/s is suggested. The
wave preheat process should be such that the
temperature of the power module board is kept below
210°C. For Pb solder, the recommended pot
temperature is 260°C, while the Pb-free solder pot is
270°C max. Not all RoHS-compliant through-hole
products can be processed with paste-through-hole
Pb or Pb-free reflow process. If additional information
is needed, please consult with your Lineage Power
representative for more details.
LINEAGE POWER
10
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Mechanical Outline
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
TOP
VIEW
SIDE
VIEW
† Optional pin lengths shown in Table 2, Device Options.
BOTTOM
VIEW
LINEAGE POWER
11
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Recommended Pad Layout
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
LINEAGE POWER
12
Data Sheet
March 26, 2008
EUK240 Series Power Modules; DC-DC converters
36 – 60Vdc input; 9.6Vdc Output; 240W
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Input
Voltage
Output
Voltage
Output
Power
Efficiency
Connector
Type
Comcodes
EUK240S9R041Z
36-60 Vdc
9.6V
240W
96%
Through hole
CC109114294
EUK240S9R0641Z
36-60 Vdc
9.6V
240W
96%
Through hole
CC109143525
Product codes
-Z indicates RoHS Compliant modules
Table 2. Device Options
Option
Negative remote on/off logic
Suffix
1
Auto-restart (must be ordered)
4
Pin Length: 3.68 mm ± 0.25mm , (0.145 in. ± 0.010 in.)
6
Pin Length: 2.79 mm ± 0.25mm , (0.110 in. ± 0.010 in.)
8
Asia-Pacific Headquarters
Tel: +65 6416 4283
World Wide Headquarters
Lineage Power Corporation
3000 Skyline Drive, Mesquite, TX 75149, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-284-2626)
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49 89 6089 286
India Headquarters
Tel: +91 80 28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
© 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.
Document No: DS06-113 ver. 1.03
PDF name: euk240_series_ds.pdf