MURATA-PS EUS15-120

BUS CONVERTER
EUS15-120 Model
Features:
9
48 Vin, Isolated, 4:1 Fixed Conversion Ratio
9
220 Watt Nominal Output (at 48 Vin, 55 C, 200 LFM)
9
170 Watt Output (at 38 Vin, 55 C, 200 LFM)
9
Industry Standard 1/8 Brick Footprint
9
Remote Enable (Primary Side, Positive or Negative)
9
Over-temperature and Over Current Protection
9
Direct Parallel Operation for Higher Power Applications
9
RoHS Compliant
Table 1
Input Characteristics
Notes & Conditions (1)
Input Voltage Operating Range
Input Voltage Absolute Maximum
Input Undervoltage Lockout
Input Overvoltage Lockout
Maximum Input Current
No-Load Input Current
Disabled Input Current
Input Reflected Ripple Current
Inrush Current Transient
Turn-on Threshold
Turn-off Threshold
Hysteresis Voltage
Turn-on Threshold
Turn-off Threshold
Hysteresis Voltage
Steady-State (23 A out)
Enabled state, on load (48 Vin)
Disabled state (48 Vin)
Min
Typ.
Max
Units
36
48
55
60
37.5
35.5
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Adc
mA
mA
mA p-p
2
As
36
34
2
56
55
58
57
2
5.5
80
6
50
0.2
Enable – Negative Logic Version
Internal 10 K pull-up to 5 V.
On State range
Off State range
-0.1
2.4
0.8
5.0
Vdc
Vdc
Enable – Positive Logic Version
Internal 100 K pull-down to GND.
On State range
Off State range
2.4
-0.1
5.0
0.8
Vdc
Vdc
Table 2
Output Characteristics
Notes & Conditions (1)
Min
Typ.
Max
Units
Output Voltage Set Point (Vo=Vin/4 +0/-0.5%)
Output Load Regulation
Output Voltage Total Regulation
Vin = 48.0 V, Io = 0 A
Io = 0 to 15 A
Vin = 36 to 55 V, Io = 0 to 15 A,
Vin = 42 to 53 V, Io = 0 to 15 A,
20 MHz Bandwidth
11.94
11.98
0.7
12.0
Vdc
V
Vdc
Vdc
mV p-p
A
%
mS
mS
mV
Output Ripple Voltage & Noise
Output Current Operating Range
Efficiency
Turn-On Time
Start-up Inhibit Time
Transient Response (3)
8.3
9.7
90
0
Vin = 48 V, Io = 15 A
Vin present: Enable to 90% Vout
Enabled: Vin applied to 90% Vout
25% step, 0.1A/μs, ΔVo
Recovery Time
Maximum Output Capacitance (4)
13.75
13.25
150
15
96
10
80
160
100
3000
μs
μF
Technical enquiries email: [email protected], tel: +508 339 3000
1
BUS CONVERTER
EUS15-120 Model
Table 1
Protection Characteristics
Notes & Conditions (1)
Min
Typ.
Max
Units
Output Over-Current Shutdown
Non-Latching
Re-start rate
Peak
Non-Latching
21
23
TBD
TBD
125
10
25
A
msec
Ap
°C
°C
Short Circuit Current
Over Temperature Shutdown (5)
Over Temperature Restart Hysteresis
130
Table 2
General Specifications
Notes & Conditions (1)
Min
Isolation Voltage
Isolation Resistance
Storage Temperature Range
Operating Temperature Range
Thermal Measurement Location Temperature (7)
Material Flammability
MTBF
Input to Output
Input to Output
Non-condensing
Ambient (7)
See mechanical drawing for location
UL 94V-0
Calculated (Bellcore TR-332)
Demonstrated
2.28”L x 0.9”W x 0.48”H (max)
(57.9L x 22.9W x 12.19H mm max)
2250
10
-40
-40
Dimension
1
Weight
Typ.
TBD
TBD
Max
Units
125
100
120
Vdc
Mohm
°C
°C
°C
6
x10 Hrs
6
x10 Hrs
grams
Table 3
Standards Compliance
Notes & Conditions (6)
UL/CSA 60950
EN60950
Basic Insulation
Certified by TUV
Notes:
(1)
Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted.
(2)
Output ripple voltage and noise is specified when measured with no external capacitance.
(3)
Transient response is specified without a capacitor at the output of the converter.
(4)
Product operates with an external capacitance greater than specified. For higher values please contact a Celestica representative.
(5)
Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location.
(6)
See ‘Safety Considerations’ shown on last page.
(7)
De-rating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement Location
temperature is below the maximum specified.
(8)
Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow).
2
BUS CONVERTER
EUS15-120 Model
Mechanical Information
Figure 1
Pin Assignment
Table 4
Pin #
Pin Name
Function
1
Vi(+)
Positive Input Voltage
2
En
Input Enable / Disable
3
4
5
Vi(-)
Vo(-)
Vo(+)
Negative Input Voltage
Negative Output Voltage
Positive Output Voltage
Notes & Conditions
Referenced to Vi(-).
Positive Logic: Floating = Enabled
Negative Logic: Floating = Disabled
3
BUS CONVERTER
EUS15-120 Model
Efficiency Curves
Efficiency (%) vs. Iout (A) and Vin (V)
97%
96%
95%
94%
93%
92%
91%
55Vin
90%
48Vin
42Vin
89%
38Vin
88%
0
2
4
6
8
10
12
14
16
18
20
Figure 2
Output Voltage vs. Current
Vo (V) vs. Io (A) and Vin (V)
14
13
12
11
10
9
55 Vin
8
48 Vin
7
42 Vin
38 Vin
6
0
2
4
6
8
10
12
14
16
18
Figure 3
4
20
BUS CONVERTER
EUS15-120 Model
Thermal Derating Curves (Transverse) TTML=120C
Airflow from pin 3 to pin 1
Iout (A) vs. Tam b (C) and Air Flow (LFM)
42 Vin
Iout (A) vs. Tamb (C) and Air Flow (LFM)
38 Vin
24
22
20
18
16
14
12
10
8
6
4
2
0
24
22
20
18
16
14
12
10
8
6
4
2
0
100 LFM
200 LFM
300 LFM
400 LFM
25
35
45
55
65
75
85
100 LFM
200 LFM
300 LFM
400 LFM
25
Figure 4
24
22
20
18
16
14
12
10
8
6
4
2
0
200 LFM
300 LFM
400 LFM
35
55
65
75
85
Iout (A) vs. Tam b (C) and Air Flow (LFM)
55 Vin
100 LFM
25
45
Figure 5
Iout (A) vs. Tam b (C) and Air Flow (LFM)
48 Vin
24
22
20
18
16
14
12
10
8
6
4
2
0
35
45
55
65
75
100 LFM
200 LFM
300 LFM
400 LFM
25
85
Figure 6
35
Figure 7
5
45
55
65
75
85
BUS CONVERTER
EUS15-120 Model
Pout (W) vs. Tamb (C) and Vin (V)
200 LFM
275
250
225
200
175
150
125
100
75
50
25
0
38 Vin
42 Vin
48 Vin
55 Vin
25
35
45
55
65
75
85
Figure 8
6
BUS CONVERTER
EUS15-120 Model
Turn-on from Vin (Enable On)
Figure 9
Turn-on from Enable (Vin present)
Ch3: En; Ch2: Vout
Figure 10
Vin=48V, Io=15A, Co=3000uF
Vin=48V, Io=15A, Co=3000uF
Output Ripple/Noise
Figure 11
Ch3: Vin; Ch2: Vout
Vin=48V, Io=15A
Vripple = 114 mVpp
7
BUS CONVERTER
EUS15-120 Model
Safety Considerations
The EUS series of converters are certified to the standards listed in the ‘Standards Compliance’ section in the table above. If this product is built into information
technology equipment, the installation must comply with the above standard.
An external input fuse (10 A recommended), must be used to meet the above requirements.
The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements.
The converters and materials meet UL 94V-0 flammability ratings.
Figure 12
Ordering Information