Spectrum FD34H-1 Frequency doubler Datasheet

Model FD34H-1
Frequency Doubler
Input 5 to 2800 MHz
Output 10 to 5600 MHz
High Isolation, In-line Output
Electrical Specifications
:
(1)
Conditions
Parameter
Insertion Loss:(2)
Fundamental Isolation: (3)
Third Harmonic
Suppression: (4)
Input VSWR:
Input Power:
Input (MHz)
5-2000
2000-2800
5-500
500-2000
2000-2800
5-2800
5-500
500-2000
2000-2800
5-2800
Output (MHz)
10-4000
4000-5600
10-1000
1000-4000
4800-5600
10-5600
Specifications
Min
25 dB
30 dB
25 dB
20 dBc
Typical
11.5 dB
12.3 dB
35 dB
40 dB
35 dB
33 dBc
Max
13.0 dB
13.5 dB
1.5:1
1.7:1
1.5:1
+11 dBm
10-1000
1000-4000
4800-5600
10-5600
Notes:
1. Specifications are guaranteed when tested as a doubler in a 50 Ohm system at +25˚C with nominal input
power. Specifications indicated as typical are not guaranteed.
2. Insertion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C.
3. Fundamental isolation is referenced to the fundamental input.
4. Third Harmonic Suppression is referenced to the second harmonic output.
FD34H-1
Outline: FPD1
Typical
Performance
at 25˚C
All dimensions are in inches and [mm].
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532
www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001
Rev.
3/17/08