SY FR5J Surface mount fast recovery rectifier Datasheet

FR5A THRU FR5M
SURFACE MOUNT FAST RECOVERY RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 5.0 Amperes
FEATURES
DO-214AB
The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
For surface mounted applications
Low reverse leakage
Built-in strain relief,ideal for automated placement
High forward surge current capability
High temperature soldering guaranteed:
250 C/10 seconds at terminals
Glass passivated chip junction
0.245(6.22)
0.220(5.59)
0.126 (3.20)
0.114 (2.90)
0.280(7.11)
0.260(6.60)
0.012(0.305)
0.006(0.152)
MECHANICAL DATA
0.103(2.62)
0.079(2.06)
0.060(1.52)
0.030(0.76)
Case: JEDEC DO-214AB molded plastic body over passivated chip
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight:0.007 ounce, 0.25grams
0.008(0.203)MAX.
0.320(8.13)
0.305(7.75)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
SYMBOLS
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
at TL=75 C
Peak forward surge current
8.3ms single half sine-wave superimposed on
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 5.0A
Maximum DC reverse current
TA=25 C
at rated DC blocking voltage
TA=100 C
Maximum reverse recovery time
(NOTE 1)
Typical junction capacitance (NOTE 2)
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
VRRM
VRMS
VDC
FR5A FR5B FR5D
50
35
50
100
70
100
200
140
200
FR5G FR5J
FR5K FR5M
UNITS
400
280
400
800
560
800
1000
700
1000
VOLTS
VOLTS
VOLTS
600
420
600
I(AV)
5.0
Amps
IFSM
150.0
Amps
VF
1.3
Volts
IR
5.0
100.0
µA
trr
150
250
CJ
78.0
RθJA
TJ,TSTG
50.0
-65 to +150
Note:1.Reverse recovery condition IF=0.5A,IR=1.0A,Irr=0.25A
2.Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3.P.C.B. mounted with 0.2x0.2”(5.0x5.0mm) copper pad areas
www.shunyegroup.com
500
ns
pF
C/W
C
FIG. 1- FORWARD CURRENT DERATING CURVE
5.0
4.0
3.0
Single Phase
Half Wave 60Hz
Resistive or
inductive Load
2.0
1.0
0
0
25
50
75
100
125
150
175
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT,
AMPERES
RATINGS AND CHARACTERISTIC CURVES FR5A THRU FR5M
FIG. 2-MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
150
120
90
60
30
0
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
1
10
AMBIENT TEMPERATURE, C
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD
CURRENT,AMPERES
FIG. 3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
20
10
1
TJ=25 C
PULSE WIDTH=300 µs
1%DUTY CYCLE
0.1
0.01
0.6
0.8
1.0
1.2
1.4
1.5
FIG. 4-TYPICAL REVERSE CHARACTERISTICS
1,000
100
10
TJ=100 C
1
0.1
TJ=25 C
0.01
FIG. 5-TYPICAL TRANSIENT THERMAL IMPEDANCE
100
10
1
0.01
0.1
1
10
0
20
40
60
80
100
PERCENT OF PEAK REVERSE VOLTAGE,%
TRANSIENT THERMAL IMPEDANCE,
C/W
TRANSIENT THERMAL IMPEDANCE,
C/W
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
0.1
100
NUMBER OF CYCLES AT 60 Hz
100
FIG. 6-TYPICAL TRANSIENT THERMAL IMPEDANCE
100
10
1
0.1
0.01
t,PULSE DURATION,sec.
0.1
1
10
t,PULSE DURATION,sec.
www.shunyegroup.com
100