FTC16A60F 16Amps Triac Rectifiers Isolated Type DESCRIPTION MECHANICAL DIMENSION ITO-220AB DIMENSION IN MM ■ FOR USE IN HIGH BIDIRECTIONAL TRANSIENT AND BLOCKING VOLTAGE APPLICATIONS, AND FOR HIGH THERMAL CYCLING PERFORMANCE. ■ TYPICAL APPLICATION INCLUDING MOTOR CONTROL, INDUSTRIAL AND DOMESTIC, LIGHTING, HEATING, COPIER, MICROWAVE AND STATIC SWITCH Parameters MAX RATINGS R.M.S. ON – STATE CURRENT TC=98℃ REPETITIVE PEAK OFF-STATE VOLTAGE Symbol IT (RMS) VDRM SURGE ON-STATE CURRENT FULL SINE WAVE ITSM FTC16A60F 16A 600V 155A@50HZ / 170A@60HZ 50/60HZ PEAK NON-REPETITIVE I2T FOR FUSE I 2T PEAK GATE POWER DISSIPATION PG 120A2S 5W PGAV 0.5W PEAK GATE CURRENRT IGM 2A PEAK GATE VOLTAGE VGM 10V OPERATING JUNCTION and STORAGE To/Ts AVERAGE PEAK GATE POWER DISSIPATION -40~+125℃ TEMPERATURE RANGE ELECTRICAL CHARACTERISTICS Tj=125℃ OFF-STATE LEAKAGE CURRENT VD=VDRM IDRM MAX 2mA ON-STATE VOLTAGE IT=12A, INST VTM MAX 1.4V NON-TRIGGER GATE VOLTAGE VD=1/2VDRM VGD MIN 0.2V (dv/dt)c MIN 10V/uS IH Rth(j-c) TYPE 25mA MAX 1.4℃/W GATE TRIGGER CURRENT VD=6V, RL=10Ω IGT MAX 30mA GATE TRIGGER VOLTAGE VD=6V, RL=10Ω VGT MAX1.5V CRITICAL RATE OF RISE OFF-STATE VOLTAGE HOLDING CURRENT THERMAL IMPEDANCE@ JUNCTION TO CASE