MPD G203EI High isolation, 2w low cost, minidip dc/dc converter Datasheet

G200EI Series
High Isolation, 2W
Low Cost, MiniDIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
• Compact MiniDIP Case
• UL Approved (File E245422)
• Single & Dual Outputs
• 3,000 VDC Isolation
• >3.5 MHour MTBF
• 24 Standard Models
• LOWEST COST!!
Parameter
Input Voltage Range
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
Input Filter
VDC
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Typ.
Max.
Units
±1.0
±3.0
%
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Dual Output , Balanced Loads
±1.0
%
For Vin Change of 1%
±1.2
%
See Model Selection Guide
Ripple & Noise (20 MHz)
Output Power Protection
100
150
mV P - P
±0.02
±0.03
%/ºC
Max.
Units
120
Temperature Coefficient
Output Short Circuit
RoHS Compliant
Units
%
Momentary (1.0 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
3,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
MΩ
60
pF
75
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Typ.
Max.
-40
+25
+85
ºC
+125
ºC
95
%
-55
Cooling
Humidity
Min.
Units
Free Air Convection
RH, Non-condensing
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size (5V 12V & 24V Input Models)
0.80 x 0.32 x 0.39 Inches (20.4 x 8.2 x 10.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.07 Oz (2.1g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Safety Standards
UL 1950, EN 60950, IEC 60950
Safety Approvals
UL, cUL; File No. E245422
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
Units
VDC
1.5 mm From Case For 10 Sec
300
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Output
Load
Voltage (VDC)
Current (mA)
Regulation
Voltage Current
Current
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
5
4.5 - 5.5
500
30
5.0
400.0
40.0
15
5
4.5 - 5.5
494
30
9.0
222.0
23.0
15
5
4.5 - 5.5
488
30
12.0
167.0
17.0
15
5
4.5 - 5.5
476
30
15.0
133.0
14.0
15
5
4.5 - 5.5
488
30
±5.0
±200.0
±20.0
15
5
4.5 - 5.5
482
30
±9.0
±111.0
±12.0
15
5
4.5 - 5.5
470
30
±12.0
±83.0
±9.0
15
5
4.5 - 5.5
470
30
±15.0
±67.0
±7.0
15
12
10.8 - 13.2
208
15
5.0
400.0
40.0
15
12
10.8 - 13.2
201
15
9.0
222.0
23.0
15
12
10.8 - 13.2
198
15
12.0
167.0
17.0
15
12
10.8 - 13.2
196
15
15.0
133.0
14.0
15
12
10.8 - 13.2
201
15
±5.0
±200.0
±20.0
15
12
10.8 - 13.2
198
15
±9.0
±111.0
±12.0
15
12
10.8 - 13.2
194
15
±12.0
±83.0
±9.0
15
12
10.8 - 13.2
194
15
±15.0
±67.0
±7.0
15
24
21.6 - 26.4
103
8
5.0
400.0
40.0
15
24
21.6 - 26.4
99
8
9.0
222.0
23.0
15
24
21.6 - 26.4
98
8
12.0
167.0
17.0
15
24
21.6 - 26.4
97
8
15.0
133.0
14.0
15
24
21.6 - 26.4
99
8
±5.0
±200.0
±20.0
15
24
21.6 - 26.4
98
8
±9.0
±111.0
±12.0
15
24
21.6 - 26.4
96
8
±12.0
±83.0
±9.0
15
24
21.6 - 26.4
96
8
±15.0
±67.0
±7.0
15
Model
Number
G201EI
G202EI
G203EI
G204EI
G205EI
G206EI
G207EI
G208EI
G211EI
G212EI
G213EI
G214EI
G215EI
G216EI
G217EI
G218EI
G221EI
G222EI
G223EI
G224EI
G225EI
G226EI
G227EI
G228EI
Notes:
1. Output load regulation is specified for a load change of 10% to
100%.
2. These units should not be operated with a load under 10% of
full load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended
that an external ceramic capacitor be placed from the +Vout
pin to the -Vout pin for single output units and from each output to common for dual output units. An input capacitor will
enhance stability over temperature and input line variations.
Recommended capacitor values are given in the table below.
For applications requiring very low output noise levels, a simple
LC filter should be effective.
Output Capacitor
Input
Vin
Vout
Capacitor
Single
Dual
5 VDC
4.7 μF
5 VDC 10.0 μF 4.7 μF
12 VDC
2.2 μF
9 VDC
4.7 μF
2.2 μF
24 VDC
1.0 μF
12 VDC 2.2 μF
1.0 μF
15 VDC 1.0 μF 0.47 μF
Efficiency
(%, Typ)
80
81
82
84
82
83
85
85
80
83
84
85
83
84
86
86
81
84
85
86
84
85
87
87
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
500
250
250
250
250
250
250
250
250
Derating Curve
Mechanical Dimensions
4. Dual output units may be connected to provide a 10V, 18V, 24V
or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output
common
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for
the correct rating.
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
7
8
-Vin
NC
+Vout
-Vin
NC
+Vout
9
10
14
No Pin
-Vout
+Vin
Common
-Vout
+Vin
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages