Omron G8P-1A4P Up to 30 a switching capacity in compact package. Datasheet

Power PCB Relay
G8PT
• Up to 30 A switching capacity in compact package.
• NEW G8P-1A4P-BG with 2.0 mm contact gap and high
dielectric strength of 4,000 VAC
• Available with quick-connect contact terminals for easy load
connecting with either QC or PCB coil terminals.
• UL Class F coil insulation standard
• Minimum 6 kV Impulse Surge Withstand.
• Ideal for home and industrial appliances, HVAC and many
other applications.
• UL recognized / CSA certified. VDE approved.
• RoHS Compliant
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G8P-1A4P-DC12).
Mounting type
PCB
Contact form
SPST-NO
Construction
Model
Open frame
G8P-1AP
G8P-1A4P-BG
Sealed with ventable nib*
SPDT
PCB & Quick Connect
load terminals
Flange mount Quick
Connect terminals
G8P-1A4P
Open frame
G8P-1CP
Sealed with ventable nib*
G8P-1C4P
SPST-NO
Open frame
G8P-1ATP
Sealed with ventable nib*
G8P-1A4TP
SPDT
Open frame
G8P-1CTP
Sealed with ventable nib*
G8P-1C4TP
SPST-NO
Vented
G8P-1A2T-F
SPDT
Vented
G8P-1C2T-F
Note: 1. Load terminals are .250” Quick Connect. Coil terminals on Flange Mount versions are .187” Quick Connect.
2. “-BG” version available with 12 VDC and 24 VDC coils, only.
3. Packaged with 50 pcs per tray.
* Sealed and vented optional.
Specifications
■ Contact Data
Type
SPST-NO
Rated load
30 A 250 VAC (-BG: 20 A 250 VAC), 20 A 28 VDC (-BG: - - -) 20/10 A* at 250 VAC, 20/10 A* at 28 VDC
SPDT
Contact material
Ag-Alloy (Cd free)
Rated Carry current
30 A max. (-BG: 20 A)
Max. operating voltage
250 VAC, 28 VDC (-BG: 250 VAC)
Max. operating current
AC 30 A, DC 20 A (-BG: AC 20 A)
AC 20/10 A, DC 20/10 A*
Max. switching capacity
7,500 VA, 560 W (-BG: 5,000 VA)
5,000/2,500 VA, 560/280 W*
Min. permissible load
500 mA@ 5 VDC (See note 1), 100 mA @ 5 VDC (See note 2)
20/10 A*
* NO contact/NC contact
Note: 1. Applicable for G8P-1A4TP, G8P-1CP, G8P-1C4P, G8P-1C4TP and G8P-1C2T-F versions.
2. Applicable for G8P-1AP, G8P-1A4P(-BG), G8P-1ATP and G8P-1CTP versions.
Power PCB Relay
G8PT
247
■ Coil Data
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
5
185
27
9
93
97
12
77
155
24
36
660
48
19
2,480
110
9
12,400
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
% of rated voltage
75% max.
10% min.
120% max.
Approx. 900
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Maximum Voltage is the maximum voltage that can be applied to the relay coil.
■ Characteristics
Contact resistance
100 mΩ max. (measured with 5 VDC, 1 A, voltage drop method)
Operate time
15 ms. max. (-BG: 20 ms max.)
Release time
10 ms. max.
Insulation resistance (See note 2)
100 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 minute (between coil and contacts), (-BG: 4,000 VAC)
1,500 VAC, 50/60 Hz for 1 minute (between contacts of the same polarity)
6,000 V between coil and contacts (1.2/50 μs)
Impulse surge withstand
Vibration resistance
Shock resistance
Destruction
10 to 55 Hz, 1.65 mm double amplitude for 2 hours
(-BG: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours)
Malfunction
10 to 55 Hz, 1.65 mm double amplitude for 5 minutes
Destruction
1,000 m/s2 (approx. 100 G)
Malfunction
100 m/s2 (approx. 10 G)
Ambient operating temperature
-55° to 105°C, cold coil condition (with no icing)
-55° to 85°C, hot coil condition (hot start) (with no icing)
Ambient operating humidity
5% to 85% RH
Service life
Mechanical
10 million operations minimum at 18,000 ops/hour. (-BG: 5 million operations min.)
Electrical
100,000 operations approx. at 360 ops/hr. (-BG: 40,000 operations min.)
Weight
Approx. 24 g to 31 g
Note: 1. Data shown are of initial value. Operate and release times excluding bounce.
2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
3. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib.
■ Characteristic Data
SPDT
Rated operating current (A)
Rated operating current (A)
Maximum switching capacity
SPST-NO
AC resistive load
(-BG type)
Rated operating voltage (V)
Rated operating voltage (V)
248
Power PCB Relay
G8PT
■ Characteristic Data
Electrical service life
SPST-NO
Service life (x103 operations)
Service life (x103 operations)
SPDT
Load current (A)
Load current (A)
*Except (-BG) type
Dimensions
Unit: mm (inch)
■ Relays
G8P-1CP / 1AP
Open frame, PCB terminals
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note: Terminal #4 is omitted
on G8P-1AP.
Power PCB Relay
G8PT
249
Unit: mm (inch)
G8P-1C4P / 1A4P / 1C2P / 1A2P
Terminal arrangement/
Internal connections
(Bottom view)
Sealed/Ventable, PCB terminals
Mounting holes
(Bottom view)
Note: Terminal #4 is omitted
on G8P-1A4P/1A2P.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
G8P-1CTP / 1ATP
Open frame, PCB with
Quick Connect terminals
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note: Terminal #4 is omitted
on G8P-1ATP.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
250
Power PCB Relay
G8PT
Unit: mm (inch)
G8P-1C4TP / 1A4TP / 1C2TP / 1A2TP
Sealed/Ventable, PCB with Quick Connect
terminals
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note: Terminal #4 is omitted
on G8P-1A4TP/1A2TP.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
G8P-1C2T-F / 1A2T-F
Flange mount
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note: Terminal #4 is omitted
on G8P-1A2T-F.
Note: Allow air circulation within the sealed type G8PT by removing the ventilation nib from the cover after soldering and cleaning is complete.
Power PCB Relay
G8PT
251
■ Approvals
UL Recognized (File No. E41643), CSA Certified (File No. LR31928)
Model
Contact form
G8P-1AP
G8P-1A4P
G8P-1ATP
G8P-1A4TP
G8P-1A2T-F
Coil ratings
SPST-NO
5 to 110 VDC
SPDT
5 to 110 VDC
G8P-1A4P-BG
G8P-1CP
G8P-1C4P
G8P-1CTP
G8P-1C4TP
G8P-1C2T-F
Contact ratings
30 A, 240 VAC (G.P./Res.), 40°C, 50,000 cycles
20 A, 28 VDC (Res.), 40°C, 6,000 cycles
20 A, 240 VAC (Res.), 70°C, 100,000 cycles
23 A, 240 VAC (Res.), 85°C, 100,000 cycles
1 HP, 125-250 VAC, 40°C, 1,000 cycles
2 HP, 250 VAC, 40°C, 1,000 cycles
A300 Pilot Duty, 40°C, 6,000 cycles
20 FLA, 96 LRA, 125 VAC, 40°C, 100,000 cycles
5 A, 250 VAC (Tungsten), 40°C, 6,000 cycles
20 A, 120-277 VAC (Ballast), 40°C, 6,000 cycles
TV-5, 40°C, 25,000 cycles
30 A, 277 VAC (Res.), 85°C, 30,000 cycles
NO/NC
30 A/20 A, 277 VAC (Res.), 40°C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.)
20 A/15 A, 250 VAC (Res.), 105°C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.)
20 A/10 A, 28 VDC (Res.), 40°C, 6,000 cycles
30 A/30 A, 277 VAC(Res.), 40°C, 10,000 cycles
1/2 HP/1/2 HP, 125 VAC, 40°C, 100,000 cycles
2 HP/ 1/2 HP, 250 VAC, 40°C, 1,000 cycles
1 HP/ 1/4 HP, 125 VAC, 40°C, 1,000 cycles
B150 Pilot Duty, 40°C, 100,000 cycles
5 A/ 3 A, 250 VAC (Tungsten), 40°C, 6,000 cycles
6 A/ 3 A, 277 VAC (Ballast), 40°C, 6,000 cycles
TV-5 (N.O.), 40°C, 25,000 cycles
VDE recognized type (Licence No. 40004714)
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA) may be different from the performance characteristics
individually defined in this catalog.
2. For information on additional ratings not included in this catalog, contact your local Omron Representative.
3. In the interest of product improvement, specifications are subject to change.
4. Please contact Omron for details regarding VDE approvals.
5. Meets requirements of polluiton degree 2 with Material II & III.
Precautions
Recommended soldering condition
Pre-heat at 120°C maximum within 120 seconds.
Complete solering at 265°C maximum within 6 seconds.
Re: the Electrical Appliance and Material Safety Law (Japan)
The G8P series is not compliant with the Electrical Appliance and
Material Safety Law of Japan. Pay careful attention to select a suitable Relay for the application.
252
Power PCB Relay
G8PT
MEMO
Power PCB Relay
G8PT
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1c
Power PCB Relay
08//12
G8PT
Specifications subject to change without notice
Printed in USA
Similar pages