Power PCB Relay G8PT • Up to 30 A switching capacity in compact package. • NEW G8P-1A4P-BG with 2.0 mm contact gap and high dielectric strength of 4,000 VAC • Available with quick-connect contact terminals for easy load connecting with either QC or PCB coil terminals. • UL Class F coil insulation standard • Minimum 6 kV Impulse Surge Withstand. • Ideal for home and industrial appliances, HVAC and many other applications. • UL recognized / CSA certified. VDE approved. • RoHS Compliant Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G8P-1A4P-DC12). Mounting type PCB Contact form SPST-NO Construction Model Open frame G8P-1AP G8P-1A4P-BG Sealed with ventable nib* SPDT PCB & Quick Connect load terminals Flange mount Quick Connect terminals G8P-1A4P Open frame G8P-1CP Sealed with ventable nib* G8P-1C4P SPST-NO Open frame G8P-1ATP Sealed with ventable nib* G8P-1A4TP SPDT Open frame G8P-1CTP Sealed with ventable nib* G8P-1C4TP SPST-NO Vented G8P-1A2T-F SPDT Vented G8P-1C2T-F Note: 1. Load terminals are .250” Quick Connect. Coil terminals on Flange Mount versions are .187” Quick Connect. 2. “-BG” version available with 12 VDC and 24 VDC coils, only. 3. Packaged with 50 pcs per tray. * Sealed and vented optional. Specifications ■ Contact Data Type SPST-NO Rated load 30 A 250 VAC (-BG: 20 A 250 VAC), 20 A 28 VDC (-BG: - - -) 20/10 A* at 250 VAC, 20/10 A* at 28 VDC SPDT Contact material Ag-Alloy (Cd free) Rated Carry current 30 A max. (-BG: 20 A) Max. operating voltage 250 VAC, 28 VDC (-BG: 250 VAC) Max. operating current AC 30 A, DC 20 A (-BG: AC 20 A) AC 20/10 A, DC 20/10 A* Max. switching capacity 7,500 VA, 560 W (-BG: 5,000 VA) 5,000/2,500 VA, 560/280 W* Min. permissible load 500 mA@ 5 VDC (See note 1), 100 mA @ 5 VDC (See note 2) 20/10 A* * NO contact/NC contact Note: 1. Applicable for G8P-1A4TP, G8P-1CP, G8P-1C4P, G8P-1C4TP and G8P-1C2T-F versions. 2. Applicable for G8P-1AP, G8P-1A4P(-BG), G8P-1ATP and G8P-1CTP versions. Power PCB Relay G8PT 247 ■ Coil Data Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 5 185 27 9 93 97 12 77 155 24 36 660 48 19 2,480 110 9 12,400 Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 75% max. 10% min. 120% max. Approx. 900 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The “Maximum Voltage is the maximum voltage that can be applied to the relay coil. ■ Characteristics Contact resistance 100 mΩ max. (measured with 5 VDC, 1 A, voltage drop method) Operate time 15 ms. max. (-BG: 20 ms max.) Release time 10 ms. max. Insulation resistance (See note 2) 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute (between coil and contacts), (-BG: 4,000 VAC) 1,500 VAC, 50/60 Hz for 1 minute (between contacts of the same polarity) 6,000 V between coil and contacts (1.2/50 μs) Impulse surge withstand Vibration resistance Shock resistance Destruction 10 to 55 Hz, 1.65 mm double amplitude for 2 hours (-BG: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours) Malfunction 10 to 55 Hz, 1.65 mm double amplitude for 5 minutes Destruction 1,000 m/s2 (approx. 100 G) Malfunction 100 m/s2 (approx. 10 G) Ambient operating temperature -55° to 105°C, cold coil condition (with no icing) -55° to 85°C, hot coil condition (hot start) (with no icing) Ambient operating humidity 5% to 85% RH Service life Mechanical 10 million operations minimum at 18,000 ops/hour. (-BG: 5 million operations min.) Electrical 100,000 operations approx. at 360 ops/hr. (-BG: 40,000 operations min.) Weight Approx. 24 g to 31 g Note: 1. Data shown are of initial value. Operate and release times excluding bounce. 2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. 3. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib. ■ Characteristic Data SPDT Rated operating current (A) Rated operating current (A) Maximum switching capacity SPST-NO AC resistive load (-BG type) Rated operating voltage (V) Rated operating voltage (V) 248 Power PCB Relay G8PT ■ Characteristic Data Electrical service life SPST-NO Service life (x103 operations) Service life (x103 operations) SPDT Load current (A) Load current (A) *Except (-BG) type Dimensions Unit: mm (inch) ■ Relays G8P-1CP / 1AP Open frame, PCB terminals Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) Note: Terminal #4 is omitted on G8P-1AP. Power PCB Relay G8PT 249 Unit: mm (inch) G8P-1C4P / 1A4P / 1C2P / 1A2P Terminal arrangement/ Internal connections (Bottom view) Sealed/Ventable, PCB terminals Mounting holes (Bottom view) Note: Terminal #4 is omitted on G8P-1A4P/1A2P. Pin Dimensions large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L small = 0.6 x 0.5 x 3.3L G8P-1CTP / 1ATP Open frame, PCB with Quick Connect terminals Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) Note: Terminal #4 is omitted on G8P-1ATP. Pin Dimensions large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L small = 0.6 x 0.5 x 3.3L 250 Power PCB Relay G8PT Unit: mm (inch) G8P-1C4TP / 1A4TP / 1C2TP / 1A2TP Sealed/Ventable, PCB with Quick Connect terminals Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) Note: Terminal #4 is omitted on G8P-1A4TP/1A2TP. Pin Dimensions large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L small = 0.6 x 0.5 x 3.3L G8P-1C2T-F / 1A2T-F Flange mount Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) Note: Terminal #4 is omitted on G8P-1A2T-F. Note: Allow air circulation within the sealed type G8PT by removing the ventilation nib from the cover after soldering and cleaning is complete. Power PCB Relay G8PT 251 ■ Approvals UL Recognized (File No. E41643), CSA Certified (File No. LR31928) Model Contact form G8P-1AP G8P-1A4P G8P-1ATP G8P-1A4TP G8P-1A2T-F Coil ratings SPST-NO 5 to 110 VDC SPDT 5 to 110 VDC G8P-1A4P-BG G8P-1CP G8P-1C4P G8P-1CTP G8P-1C4TP G8P-1C2T-F Contact ratings 30 A, 240 VAC (G.P./Res.), 40°C, 50,000 cycles 20 A, 28 VDC (Res.), 40°C, 6,000 cycles 20 A, 240 VAC (Res.), 70°C, 100,000 cycles 23 A, 240 VAC (Res.), 85°C, 100,000 cycles 1 HP, 125-250 VAC, 40°C, 1,000 cycles 2 HP, 250 VAC, 40°C, 1,000 cycles A300 Pilot Duty, 40°C, 6,000 cycles 20 FLA, 96 LRA, 125 VAC, 40°C, 100,000 cycles 5 A, 250 VAC (Tungsten), 40°C, 6,000 cycles 20 A, 120-277 VAC (Ballast), 40°C, 6,000 cycles TV-5, 40°C, 25,000 cycles 30 A, 277 VAC (Res.), 85°C, 30,000 cycles NO/NC 30 A/20 A, 277 VAC (Res.), 40°C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.) 20 A/15 A, 250 VAC (Res.), 105°C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.) 20 A/10 A, 28 VDC (Res.), 40°C, 6,000 cycles 30 A/30 A, 277 VAC(Res.), 40°C, 10,000 cycles 1/2 HP/1/2 HP, 125 VAC, 40°C, 100,000 cycles 2 HP/ 1/2 HP, 250 VAC, 40°C, 1,000 cycles 1 HP/ 1/4 HP, 125 VAC, 40°C, 1,000 cycles B150 Pilot Duty, 40°C, 100,000 cycles 5 A/ 3 A, 250 VAC (Tungsten), 40°C, 6,000 cycles 6 A/ 3 A, 277 VAC (Ballast), 40°C, 6,000 cycles TV-5 (N.O.), 40°C, 25,000 cycles VDE recognized type (Licence No. 40004714) Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA) may be different from the performance characteristics individually defined in this catalog. 2. For information on additional ratings not included in this catalog, contact your local Omron Representative. 3. In the interest of product improvement, specifications are subject to change. 4. Please contact Omron for details regarding VDE approvals. 5. Meets requirements of polluiton degree 2 with Material II & III. Precautions Recommended soldering condition Pre-heat at 120°C maximum within 120 seconds. Complete solering at 265°C maximum within 6 seconds. Re: the Electrical Appliance and Material Safety Law (Japan) The G8P series is not compliant with the Electrical Appliance and Material Safety Law of Japan. Pay careful attention to select a suitable Relay for the application. 252 Power PCB Relay G8PT MEMO Power PCB Relay G8PT All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. X301-E-1c Power PCB Relay 08//12 G8PT Specifications subject to change without notice Printed in USA