GBPC 40, 50 SERIES High Current 40, 50 AMPS. Single Phase Glass Passivated Bridge Rectifiers Voltage Range 50 to 1000 Volts Current 40, 50.0 Amperes GBPC40 Features GBPC40-M Glass passivated junction The plastic material used carries Underwriters Laboratory Flammability Recognition 94V-0 Integrally molded heatsink provide very low thermal resistance for maximum heat dissipation Universal 4-way terminals; snap-on, wrap-around, solder or P.C. board mounting Surge overload ratings 400 amperes Typical IR less than 0.2 uA High temperature soldering guaranteed: 260℃/ 10 seconds / .375”, (9.5mm) lead lengths Isolated voltage from case to lead over 2500 volts Dimensions in inches and (millimeters) Maximum Ratings and Electrical Characteristics Rating at 25℃ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Type Number Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current GBPC40 GBPC50 @TC= 55℃ Peak Forward Surge Current, Single Sine-wave Superimposed GBPC40 on Rated Load (JEDEC method ) GBPC50 Maximum Instantaneous GBPC40 @20A Forward Voltage Drop Per Element at Specified Current GBPC50 @25A Maximum DC Reverse Current at Rated DC Blocking Voltage Per Element Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range Symbol -005 VRRM VRMS VDC 50 35 50 -01 -02 -04 -06 -08 -10 Units 100 70 100 200 140 200 400 280 400 600 420 600 800 560 800 1000 700 1000 V V V I(AV) 40.0 50.0 A IFSM 400 400 A VF 1.1 V IR 10 uA RθJC TJ ,TSTG 1.5 -50 to +150 ℃/W ℃ Notes: 1. Thermal Resistance from Junction to Case. 2. Suffix”M” - Terminal Location Face to Face. http://www.luguang.cn mail:[email protected] GBPC 40, 50 SERIES High Current 40, 50 AMPS. Single Phase Glass Passivated Bridge Rectifiers RATINGS AND CHARACTERISTIC CURVES (GBPC40005 THRU GBPC4010) GBPC50005 GBPC5010 FIG.1- MAXIMUM FORWARD CURRENT DERATING CURVE FIG.2- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 80 PEAK FORWARD SURGE CURRENT. (A) 400 60 50 GB PC 50 40 GB 30 300 200 100 80 60 40 40 PC AVERAGE FORWARD CURRENT. (A) 70 20 1 1.5 2 20 3 4 5 6 7 8 9 10 15 20 25 30 40 NUMBER OF CYCLES AT 60Hz 10 0 20 40 60 80 100 120 140 160 180 o CASE TEMPERATURE. ( C) FIG.3- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT FIG.4- TYPICAL FORWARD CHARACTERISTICS PER BRIDGE ELEMENT 10 Tj=25 0C 1 0.1 0 40 60 80 100 120 140 http://www.luguang.cn C5 G 10 BP C 40 0 Tj=25 C PULSE WIDTH-300 S 1 0.1 20 PERCENT OF RATED PEAK REVERSE VOLTAGE. (%) BP 100 G INSTANTANEOUS FORWARD CURRENT. (A) INSTANTANEOUS REVERSE CURRENT. ( A) Tj=125 0C 0 1000 100 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 FORWARD VOLTAGE. (V) mail:[email protected] 60 80 100