THINKING GC63R200NR

Gas Discharge Tube:
:GC6 Series
3-Electrode Φ6.0*8.0 mm Type
Features
1. RoHS compliant
2. Rugged ceramic-metal construction
3. Available with or without leads
4. Available with fail-safe clip
5. DC spark-over voltage:90~600V
6. Low capacitance
7. Agency recognition :UL
Recommended Applications
1. Data transmission lines
2. Communication lines
3. CATV system
4. Power distribution system
5. Power supplier
6. Test equipment
7. Instrumentation circuits
Part Number Code
Product Code
G
G
C
6
3
R
0
9
0
R
B
1
2
3
4
5
6
7
8
9
10
Electrode Number
3R
THINKING Gas
Discharge Tube
Lead Wire Style
3 Electrodes
N
R
No Lead
Radial Lead
C6
Φ6.0*T8.0
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
12
Packaging
B
T
R
Type Series (size)
11
Internal Control
Code
Bulk
Ammo
Taping
Reel
Taping
DC Spark-over
Voltage
070
230
600
14B
25B
13
Product Type
F
70V
230V
600V
1400V
2500V
1
Fail-Safe Clip
www.thinking.com.tw
2010.09
Gas Discharge Tube:
:GC6 Series
3-Electrode Φ6.0*8.0 mm Type
Characteristics
DC
Breakdown
Voltage
Max. Impulse
Breakdown
Voltage
Impulse
Discharge
Current
(8/20µs)
Impulse
Life
(10/1000µs)
Normal
Alternating
Discharge
Current
DC
Holdover
Voltage
Type
(100V/S)
100V/µs
1KV/µs
10 times
200 A
50Hz,1Sec
<150ms
(V)
(V)
(V)
(KA)
Times
(A)
(V)
Minimum
Insulation
Resistance
Maximum
Capacitance
(1MHz)
Safety
Approvals
(GΩ)
(pF)
UL
497B
GC63R090□□(F)
90±20%
750
850
5
5
52
√
GC63R145□□(F)
145±20%
750
850
5
5
52
√
GC63R200□□(F)
200±20%
600
700
10
10
135
√
GC63R230□□(F)
230±20%
600
700
10
10
135
√
GC63R250□□(F)
250±20%
600
700
10
10
135
100
√
1
2
GC63R350□□(F)
350±20%
650
750
5
5
150
√
GC63R400□□(F)
400±20%
700
800
5
5
150
√
GC63R420□□(F)
420±20%
700
800
5
5
150
√
GC63R470□□(F)
470±20%
800
900
5
5
150
√
GC63R600□□(F)
600±20%
900
1000
5
5
150
√
Note1:The first □ is the style of lead wire, and the second □ is packaging
Note2:F = with fail-safe clip for optional.
Note 3: UL / 497B→ File No. E245070
Note 4: Insulation resistance test conditions:
DC Breakdown Voltage
DC Measuring Voltage
90V
50V
145-400V
100V
420-600V
250V
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
2
www.thinking.com.tw
2010.09
Gas Discharge Tube:
:GC6 Series
3-Electrode Φ6.0*8.0 mm Type
Dimensions
□= R (Radial lead type)
Unit: mm
Item
D
T
T1
L
S
d
Dimensions
Spec.
6.0
8.5
11.5
7.5
3.8
0.8
Tolerance
+0.2/-0.5
±0.5
+0.8/-0.5
±0.5
±0.3
±0.05
□= N (No lead type)
Unit: mm
Item
Dimensions
Spec.
Tolerance
D
6.0
+0.2/-0.5
T
8.5
±0.5
□=F (Fail-Safe Device)
Unit: mm
T1
R1
Item
R1
R2
T1
L
S
d
R2
L
d
S
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
3
Dimensions
Spec.
Tolerance
6.3
±0.3
7.6
±0.4
13.4
±0.4
11.0
±0.5
4.4
±0.3
1.0
±0.05
www.thinking.com.tw
2010.09
Gas Discharge Tube:
:GC6 Series
3-Electrode Φ6.0*8.0 mm Type
Marking
GC6
GC6
Packaging
Bulk
Plastic Tray
Inner Box
Outside Box
(210x220x12mm)
(210x225x60mm)
(450x245x345mm)
100 PCS/Plastic tray
500 PCS/Box
5000 PCS/Carton
Storage Condition of GDT
(I) Storage conditions:
1. Storage Temperature: -10℃ ~ +40℃.
2. Relative humidity: ≦75%RH.
3. Gas discharge tube must be kept away from sunlight and stored in a non-corrosive atmosphere.
(II) Shelf life: 1 year.
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
4
www.thinking.com.tw
2010.09