ETC GDB-5A

Bussmann®
5 x 20mm Ferrule Fuses
GDB
GDB-V
Fast Acting, Low Breaking Capacity
38.10mm
(±.38)
Time-Current Characteristic Curves–Average Melt
21.10mm
(±.81)
10mm 20mm
(±2.0) (±0.5)
32mA
40mA
50mA
63mA
5.54mm
(±.20)
80mA
100mA
125mA
160mA
200mA
250mA
315mA
400mA
500mA
630mA
800mA
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
Dimensional Data
100
AMPERE
RATING
38.10mm
(±.38)
5.2mm
(+0.1/-0.2)
.81mm
(REF)
10
TIME IN SECONDS
Glass tube - end caps: nickel
or silver-plated brass.
CATALOG SYMBOL: GDB
FAST-ACTING, LOW BREAKING CAPACITY
250 VOLTS AC
UL RECOGNIZED:
(GUIDE #JDYX2, FILE #E75865)
1
Limits for Pre-arcing Time
1.5 In
MIN
In
2.1 In
MAX
2.75 In
MIN
MAX
4 In
MIN
32mA - 100mA 60 min. 30 min. 10 ms. 500 ms. 3 ms.
125mA - 6.3A
60 min. 30 min. 50 ms. 2 sec.
8A - 10A
60 min. 30 min.
12A - 16A
—
30 min.
MAX
10 In
MAX
100 ms.
20 ms.
10 ms. 300 ms.
.1
20 ms.
—
—
—
—
40 ms.
—
—
—
—
80 ms.
1.1 In: Æt ² 70°C, 125mA - 3A.
1.0 In: Æt ² 70°C, 4A.
Product
Symbol
Lead
100
10
Packaging & Ordering Information:
1
.1
.01
CURRENT IN AMPERES
Ampere
Rating
Package Code
Blank (None)
V Axial Leads
GDB only .0329 x 1.59
Copper Tinned
GDB
S500†
Markings: MFG mark, Rated Current, Rated Voltage, Characteristic Symbol,
Breaking Capacity Symbol, Approvals where Applicable.
† S500 is an European Designation. In North America use GDB respectively
when referencing product.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
12-18-98
SB98107
Rev. A
Form No. GDB
Page 1 of 2
BIF Doc #2015
Bussmann®
5 x 20mm Ferrule Fuses
GDB
GDB-V
Fast Acting, Low Breaking Capacity
include ratings
Pre-arcing
Value
(I2t) (A2s) typ.
0.000047
0.00011
0.00020
0.00057
0.0012
0.003
0.005
0.008
0.016
0.028
0.058
0.18
0.18
0.35
0.67
0.60
0.84
1.6
4.2
6.1
13
22
42
69
—
—
—
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
UR
10 x In
250V, 50Hz
cos ø Å 1.0
Power
Dissipation
(W) max.
0.90
0.85
0.40
0.40
0.45
0.55
0.65
0.80
0.85
0.95
1.0
1.0
0.30
0.40
0.45
0.67
0.92
1.1
1.1
1.2
1.3
1.6
1.7
2.3
—
—
—
—
IMQ
35A at
250V, 50Hz
cos ø Å 1.0
Voltage
Drop
(mV) max.
10000
8000
3200
2500
2200
2100
2000
1950
1600
1400
1150
950
220
220
180
200
200
190
160
145
130
120
115
110
—
—
—
—
above 6.3 amps.
SEMKO
Breaking
Capacity
VDE
Current
Rated
Rating
Voltage
(In)
(V)
32mA
40mA
50mA
63mA
80mA
100mA
125mA
160mA
200mA
250mA
315mA
400mA
500mA
250
630mA
800mA
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A*
10A*
12A*
16A*
* IEC Standard 127 Sheet II does not
BSI
Electrical Characteristics
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
12-18-98
SB98107
Rev. A
Form No. GDB
Page 2 of 2
BIF Doc #2015