ETC GLT44016-25TC 256k x 16 cmos dynamic ram with extended data output Datasheet

G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Features :
Description :
∗
∗
∗
∗
∗
The GLT44016 is a 262,144 x 16 bit
high-performance CMOS dynamic random
access memory. The GLT44016 offers Fast
Page mode with Extended Data Output, and
has both BYTE WRITE and WORD WRITE
access cycles via two CAS pins. The
GLT44016 has symmetric address and
accepts 512-cycle refresh in 8ms interval.
All inputs are TTL compatible. EDO
Page Mode operation allows random access
up to 512 x 16 bits within a page, with cycle
times as short as 10ns.
The GLT44016 is best suited for
graphics, and DSP applications requiring
high performance memories.
262,144 words by 16 bits organization.
Fast access time and cycle time.
Dual CAS Input.
Low power dissipation.
Read-Modify-Write, RAS -Only Refresh,
CAS -Before- RAS Refresh, Hidden
Refresh and Test Mode Capability.
512 refresh cycles per 8ms.
Available in 40-Pin 400 mil SOJ and 40/44
Pin TSOP(II)
∗ Single 5.0V±10% Power Supply.
∗ All inputs and Outputs are TTL
compatible.
∗ Extended Data-Out(EDO) Page Mode
operation.
∗
∗
HIGH PERFORMANCE
25
28
30
35
40
50
Max. RAS Access Time, (tRAC)
25 ns 28 ns 30 ns 35 ns 40 ns 50 ns
Max. Column Address Access Time, (tCAA)
13 ns 13 ns 16 ns 18 ns 20 ns 25 ns
Min. Extended Data Out Page Mode Cycle Time, (tPC)
10 ns 10 ns 12 ns 13 ns 15 ns 20 ns
Min. Read/Write Cycle Time, (tRC)
45 ns 45 ns 60 ns 65 ns 70 ns 85 ns
Max. CAS Access Time (tCAC)
8 ns
8 ns
10 ns 11 ns 12 ns 14 ns
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-1-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Pin Configuration :
GLT44016
SOJ Top View
TSOP(Type II)
Top View
Pin Descriptions:
Name
A0 - A8
Function
RAS
Address Inputs
Row Address Strobe
UCAS
Column Address Strobe/Upper Byte Control
LCAS
Column Address Strobe/Lower Byte Control
WE
Write Enable
OE
Output Enable
DQ1 - DQ16
VCC
VSS
NC
Data Inputs / Outputs
+5V Power Supply
Ground
No Connection
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-2-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Absolute Maximum Ratings*
Capacitance*
TA=25°C, VCC=5V±10%, VSS=0V
Operating Temperature, TA (ambient)
Symbol
.......................................-0°C to +70°C
Storage Temperature(plastic)....-55°C to +150°C
Voltage Relative to VSS...............-1.0V to + 7.0V
Short Circuit Output Current......................50mA
Power Dissipation......................................1.0W
*Note:Operation above Absolute Maximum Ratings can
abversely affect device reliability.
Parameter
Max. Unit
CIN1
Address Input
5
pF
CIN2
RAS , LCAS , UCAS , WE , OE
7
pF
COUT
Data Input/Output
7
pF
*Note: Capacitance is sampled and not 100% tested
Electrical Specifications
l
l
l
CAS means UCAS and LCAS .
All voltages are referenced to GND.
After power up, wait more than 100µs and then, execute eight CAS -before- RAS or RAS -only
refresh cycles as dummy cycles to initialize internal circuit.
Block Diagram :
OE
WE
UCAS
LCAS
RAS CLOCK
GENERATOR
RAS
CAS CLOCK
GENERATOR
WE CLOCK
GENERATOR
OE CLOCK
GENERATOR
V CC
V SS
Data I/O BUS
COLUMN DECODERS
REFRESH
COUNTER
SENSE AMPLIFIERS
I/O
BUFFER
Y 0 - Y8
512 × 16
9
A0
A1
A7
.
.
ADDRESS BUFFERS
AND PREDECODERS
A8
ROW
DECODERS
X 0 - x8
MEMORY
ARRAY
512
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-3-
I/O1
I/O2
I/O3
I/O4
I/O5
I/O6
I/O7
I/O8
I/O9
I/O10
I/O11
I/O12
I/O13
I/O14
I/O15
I/O16
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Truth Table: GLT44016
Function
ADDRESS
DQs
RAS
CASL
CASH
WE
OE
Stanby
H
H→X
H→X
X
X
Read: Word
L
L
L
H
L
ROW/COL Data Out
Read: Lower Byte
L
L
H
H
L
Read: Upper Byte
L
H
L
H
L
Write: Word(Early
Write)
Write: Lower Byte
(Early)
L
L
L
L
X
ROW/COL Lower Byte,Data-Out
Upper Byte,High-Z
ROW/COL Lower Byte,High-Z
Upper Byte,Data-Out
ROW/COL Data-In
L
L
H
L
X
Write: Upper Byte
(Early)
L
H
L
L
X
Read Write
L
L
L
H→L
L→H
EDO-Page- 1st Cycle
L
H→L
H→L
H
L
Mode Read 2nd Cycle
L
H→L
H→L
H
L
EDO-Page- 1st Cycle
L
H→L
H→L
L
X
Mode Write 2nd Cycle
L
H→L
H→L
L
X
EDO-Page- 1st Cycle
L
H→L
H→L
H→L
L→H
L
H→L
H→L
H→L
L→H
Read
L→H→L
L
L
H
L
ROW/COL Data-Out
Write
L→H→L
L
L
L
L
X
ROW/COL Data-In
H
H
X
X
H→L
L
L
X
X
Notes
High-Z
ROW/COL Lower Byte,Data-In
Upper Byte,High-Z
ROW/COL Lower Byte,High-Z
Upper Byte,Data-In
ROW/COL Data-Out,Data-In
ROW/COL Data-Out
COL
Data-Out
ROW/COL Data-In
COL
Data-In
ROW/COL Data-Out,Data-In
1,2
1
1
2
2
1,2
Mode ReadWrite
Hidden
Refresh
2nd Cycle
RAS -Only Refresh
CBR Refresh
COL
ROW
Data-Out,Data-In
1
2,3
High-Z
High-Z
Notes:
1. These READ cycles may also be BYTE READ cycles (either UCAS or LCAS active).
2. These WRITE cycles may also be BYTE READ cycles (either UCAS or LCAS active).
3. EARLY WRITE only.
4. At least one of the two CAS signals must be active ( UCAS or LCAS ).
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-4-
1,2
4
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
DC and Operating Characteristics (1-2)
TA = 0°C to 70°C, VCC=5V±10%, VSS=0V, unless otherwise specified.
Sym.
Parameter
ILI
Input Leakage Current
(any input pin)
ILO
Output Leakage Current
(for High-Z State)
Operating Current,
Random READ/WRITE
ICC1
ICC2
ICC3
Standby Current,(TTL)
Refresh Current,
RAS -Only
Test Conditions
0V ≤ VIN ≤ 5.5V
(All other pins not under
test=0V)
0V ≤ Vout ≤ 5.5V
Output is disabled (Hiz)
ICC5
Operating Current,
EDO Page Mode
Refresh Current,
CAS Before RAS
ICC6
Standby Current, (CMOS)
Min.
LCAS at VIH
RAS at VIL, UCAS , LCAS
address cycling:tPC=tPC(min.)
RAS , UCAS , LCAS
address cycling:
tRC=tRC (min.)
Max. Unit Notes
+10
µA
-10
+10
µA
270
270
250
210
190
170
RAS , UCAS , LCAS at VIH
other inputs ≥VSS
RAS cycling, UCAS ,
Typ
-10
tRAC = 25ns
tRAC = 28ns
tRAC = 30ns
tRAC = 35ns
tRAC = 40ns
tRAC = 50ns
tRC = tRC (min.)
tRC = tRC (min.)
ICC4
Access
Time
4
270
270
250
210
190
170
270
270
250
210
190
170
270
270
250
210
190
170
tRAC = 25ns
tRAC = 28ns
tRAC = 30ns
tRAC = 35ns
tRAC = 40ns
tRAC = 50ns
tRAC = 25ns
tRAC = 28ns
tRAC = 30ns
tRAC = 35ns
tRAC = 40ns
tRAC = 50ns
tRAC = 25ns
tRAC = 28ns
tRAC = 30ns
tRAC = 35ns
tRAC = 40ns
tRAC = 50ns
RAS ≥VCC-0.2V,
mA
1,2
mA
mA
2
mA
1,2
mA
1
2
mA
+0.8
VCC+1
0.4
V
V
V
V
UCAS ≥VCC-0.2V,
LCAS ≥VCC-0.2V,
All other inputs VSS
VIL
VIH
VOL
VOH
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
-1
2.4
IOL = 4.2mA
IOH = -5.0mA
2.4
3
3
Notes:
1.ICC is dependent on output loading when the device output is selected. Specified ICC(max.) is measured with the output open.
2.ICC is dependent upon the number of address transitions specified ICC(max.) is measured with a maximum of one transition per address cycle in
random Read/Write and EDO Fast Page Mode.
3.Specified VIL(min.) is steady state operation. During transitions VIL(min.) may undershoot to -1.0V for a period not to exceed 20ns. All AC
parameters are measured with VIL(min.)≥VSS and VIH(max.)≤VCC.
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-5-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
AC Characteristics
TA = 0°C to 70°C , VCC = 5 V ± 10%, VIH/VIL = 2.4/0.8 V, VOH/VOL = 2.0/0.8V
An initial pause of 100 µs and 8 CAS -before- RAS or RAS -only refresh cycles are required after power-up.
25
28
30
35
40
50
Parameter
Symbol Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit Notes
Read or Write Cycle Time
tRC
45
45
60
65
70
85
ns
Read Modify Write Cycle Time
tRWC
67
67
79
86
91
106
ns
tRP
15
15
25
25
25
30
ns
tRAS
25
50
100k ns
RAS Precharge Time
RAS Pulse Width
Access Time from RAS
Access Time from CAS
Access Time from Column Address
CAS to Output Low-Z
CAS to Output High-Z
RAS Hold Time
RAS Hold Time Referenced to OE
CAS Hold Time
CAS Pulse Width
RAS to CAS Delay Time
RAS to Column Address Delay Time
100k
28
100k
30
100k
35
100k
40
100k
tRAC
25
28
30
35
40
50
ns
tCAC
8
8
10
11
12
14
ns 1,5,10
tAA
13
13
16
18
20
25
ns
tCLZ
0
0
0
5
3
5
0
0
7
3
0
8
3
0
8
3
1,2,3
1,5,6
ns
tCEZ
0
8
ns
tRSH
7
7
7
8
8
8
ns
tROH
4
4
7
8
8
8
ns
tCSH
25
25
25
30
35
42
ns
tCAS
4
4
4.5
5
6
8
ns
tRCD
10
17
10
17
10
20
11
24
12
28
13
36
ns
tRAD
8
12
8
12
8
14
9
17
10
20
11
25
ns
7
CAS to RAS Precharge Time
Row Address Set-Up Time
tCRP
5
5
5
5
5
5
ns
tASR
0
0
0
0
0
0
ns
Row Address Hold Time
tRAH
4
4
6
7
8
9
ns
Column Address Set-Up Time
tASC
0
0
0
0
0
0
ns
Column Address Hold Time
tCAH
4
4
5
6
6
7
ns
Column Address to RAS Lead Time
tRAL
13
13
16
18
20
25
ns
tAR
19
19
25
30
34
35
ns
tRCS
0
0
0
0
0
0
ns
tRCH
0
0
0
0
0
0
ns
4
tRRH
0
0
0
0
0
0
ns
4
tWCS
0
0
0
0
0
0
ns
8,9
Write Command Hold Time
tWCH
4
4
5
6
6
6
ns
Write Command Pulse Width
tWP
4
4
5
6
6
6
ns
tRWL
7
7
7
8
8
8
ns
tCWL
5
5
6
7
7
7
ns
Column Address Hold Time Referenced to RAS
Read Command Set-Up Time
Read Command Hold Time Referenced to CAS
Read Command Hold Time Referenced to RAS
Write Command Set-Up Time
Write Command to RAS Lead Time
Write Command to CAS Lead Time
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-6-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
AC Characteristics
25
28
30
35
40
50
Parameter
Symbol Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit Notes
Data Set-Up Time
tDS
0
Data Hold Time
tDH
4
tDHR
Data Hold Time Referenced to RAS
RAS to WE E Delay Time
CAS to WE Delay Time
Column Address to WE Delay Time
RAS to CAS Precharge Time
Access Time from CAS Precharge
EDO Page Mode Cycle Time
EDO Page Mode Read-Modify-Write Cycle Time
CAS Precharge Time (EDO Page Mode)
RAS Pulse Width (EDO Page Mode Only)
Access Time from OE
OE to Data Delay Time
OE to Output High-Z
OE Command Hold Time
Data Output Hold after CAS low
RAS to Output High-Z
WE to Output High-Z
OE to CAS Hold Time
CAS Hold Time to OE
OE Precharge Time
CAS Set-Up Time for CAS -before- RAS Cycle
CAS Hold Time for CAS -before- RAS Cycle
Transition Time
Refresh Period
0
0
0
0
ns
4
7
8
8
8
ns
19
19
27
32
36
37
ns
tRWD
36
36
43
49
54
64
ns
tCWD
19
19
21
23
24
26
ns
tAWD
24
24
27
30
32
37
ns
tRPC
0
0
0
0
0
0
ns
tCPA
15
15
tPC
10
10
12
13
15
20
ns
tPRWC
35
35
39
43
45
50
ns
tCP
3
3
4.5
5
6
8
ns
tRASP
25
50
100k ns
tOEA
0
100k
0
28
8
0
18
100k
30
8
35
10
40
11
12
tOEH
5
5
6
6
7
7
ns
tDOH
4
4
5
5
5
5
ns
tREZ
3
7
3
7
3
7
3
8
3
8
3
8
ns
tWEZ
3
10
3
10
3
10
3
10
3
10
3
12
ns
tOCH
8
8
8
8
8
8
ns
tCHO
8
8
8
8
8
8
ns
tOEP
8
8
8
8
8
8
ns
tCSR
5
5
10
10
10
10
ns
tCHR
6
6
7
8
8
10
ns
tREF
1.5
50
1.5
8
50
8
3
1.5
7
50
8
3
1.5
8
50
8
3
1.5
8
ns
3
7
8
14
ns
tOEZ
3
8
100k
27
5
7
7
100k
22
tOED
tT
5
100K
20
8
50
8
0
2
ns
8
50
ns
8
ms
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-7-
ns
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Notes:
1. Measure with a load equivalent to one TTL inputs and 50 pF.
2. Assumes that tRCD ≤ tRCD (max.). If tRCD is greater than tRCD (max.), access time will be tAA
dominant.
3. Assumes that tRAD ≤ tRAD (max.). If tRAD is greater than tRCD (max.), access time will be
controlled by tCAC.
4. Either tRRH or tRCH must be satisfied for a Read Cycle.
5. Access time is determined by the longest of tCAA, tCAC and tCPA.
6. Assumes that tRAD ≥ tRAD (max.).
7. Operation within the tRAD (max.) limit ensures that tRAC (max.) can be met. tRAD (max.)
is specified as a reference point only. If tRAD is greater than the specified tRAD (max.)
limit, the access time is controlled by tCAA and tCAC.
8. tWCS, tRWD, tAWD and tCWD are not restrictive operating parameters.
9. tWCS (min.) must be satisfied in an Early Write Cycle.
10. tDS and tDH are referenced to the latter occurrence of CAS of WE .
tT is measured between VIH (min.) and VIL (max.). AC-measurements assume tT = 1.5 ns.
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-8-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Read Cycle
tRC
tRAS
tRP
VIH-
RAS
VIL-
tCSH
tCRP
tRCD
tCRP
tRSH
VIH-
CAS
tCAS
VIL-
tRAD
tASR
V IH-
Address
V IL-
tRAL
tRAH
tASC
ROW
ADDRESS
tCAH
COLUMN
ADDRESS
tAR
tRCH
tRRH
tRCS
VIH-
WE
VIL-
tCEZ
tAA
tOEZ
VIH-
OE
tOEA
VIL-
tCAC
tCLZ
tRAC
DQ
VOHDATA-OUT
VOLDon't Care
Early Write Cycle NOTE : DOUT = Open
tRC
tRP
tRAS
VIH-
RAS
VIL-
tCSH
tCRP
tRCD
tRSH
VIH-
tCRP
tCAS
CAS
VIL-
VIH-
Address
VIL-
tASR
tRAH
tRAD
tRAL
tCAH
tASC
ROW
ADDRESS
COLUMN
ADDRESS
tCWL
tRWL
tAR
VIH-
tWCS
tWCR
tWCH
tWP
tDS
tDH
WE
VIL-
VIH-
OE
VIL-
tDHR
VIH-
DQ
VIL-
DATA - IN
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
-9-
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Late Write Cycle ( OE Controlled Write)
NOTE : DOUT = Open
tRC
tRP
tRAS
VIH-
RAS
VIL-
tCSH
tCRP
tRCD
CAS
tCRP
tRSH
VIH-
tCAS
VIL-
VIH-
Address
VIL-
tRAD
tASC
tASR
tRAH
tRAL
tCAH
ROW
ADDRESS
COLUMN
ADDRESS
tCWL
tRWL
tRCS
tWP
VIH-
WE
VIL-
OE
VIH-
tOEH
tOED
VIL-
tDS
VIH-
DQ
tDH
COLUMN
ADDRESS
VIL-
Don't Care
Read - Modify - Write Cycle
tRC
tRP
RAS
tRAS
VIHVIL-
tCRP
CAS
tRCD
tCRP
tRSH
VIH-
tCAS
VIL-
tCSH
tASR
Address
VIHVIL-
tRAH
ROW
ADDR.
tRAD
tCAH
tASC
COLUMN
ADDRESS
tAWD
tCWD
WE
OE
VIH-
tWP
VIL-
VIH-
tOEA
VIL-
tCLZ
tAA
DQ
tRWL
tCWL
VI/OHVI/OL-
tRAC
tCAC
tOED
tOEZ
VALID
DATA-OUT
tDS
tDH
VALID
DATA-IN
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 10 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Fast Page Read Cycle
tRASP
tRP
VIH-
RAS
VIL-
tPC
tCRP
tRCD
tCAS
tCP
tPC
tCAS
tCP
tRSH
tCAS
VIH-
CAS
VIL-
tRAD
tCSH
tASR
VIH-
Address
VIL-
tRAH
tASC
ROW
ADDR.
tCAH
tASC
COLUMN
ADDRESS
tRCS
tRCH
tCAH
tCAH
tASC
COLUMN
ADDRESS
COLUMN
ADDRESS
tRCS
tRCS
tRRH
tRCH
VIH-
WE
VIL-
tCAC
tCAC
tOEA
tOEA
VIH-
OE
VIL-
tAA
tRAC
tCLZ
DQ
tAA
tOFF
tCLZ
tOEZ
VIH-
tOFF
tOEZ
tAA
tOFF tCLZ
tOEZ
VILVALID
DATA-UOT
Fast Page Write Cycle
VALID
DATA-UOT
VALID
DATA-UOT
tRASP
t RP
VIH-
RAS
tRHCP
VIL-
tPC
tCRP
tRCD
tCAS
tPC
tCP
tCAS
tRSH
tCP
tCAS
VIH-
CAS
VIL-
tRAD
tASR
Address
VIHVIL-
tRAH
tASC
ROW
ADDR.
tCSH
tCAH
COLUMN
ADDRESS
tWCS
VIH-
WE
Don't Care
NOTE : DOUT = Open
tASC
tCAH
COLUMN
ADDRESS
tWCH
tWCS
tWP
tWP
tWCH
tCAH
tASC
COLUMN
ADDRESS
tWCS
tWCH
tWP
VIL-
tCWL
tCWL
tCWL
tRWL
VIH-
OE
VIL-
tDS
VIH-
DQ
VIL-
tDH
VALID
DATA-IN
tDS
VALID
DATA-IN
tDS
tDS
tDS
VALID
DATA-IN
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 11 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Fast Page Mode Late Write Cycle
tRASP
t RP
VIH-
RAS
tRHCP
VIL-
tCSH
tCRP
CAS
tRCD
t PC
tCAS
tCP
tCAS
tCP
tRSH
tCRP
tCAS
VIHVIL-
tRAD
tASR
Address
VIH-
tCAH
tASC
tRAH
COLUMN
ADDRESS
ROW
ADDR.
VIL-
VIH-
COLUMN
ADDRESS
tCWL
tRCS
tRAL
tCAH
tASC
COLUMN
ADDRESS
tCWL
tRCS
WE
tCAH
tASC
tCWL
tRWL
tRCS
tWP
tWP
tWP
tOEH
tOEH
tOEH
VIL-
VIH-
OE
VIL-
tOED
tDS
Hi-Z
VIH-
tDH
Hi-Z
VALID
DATA-IN
DQ
VIL-
tOED tDS
tOED tDS
tDH
VALID
DATA-IN
Hi-Z
tDH
VALID
DATA-IN
Don't Care
Fast Page Read - Modify - Write Cycle
tRASP
VIH-
RAS
tRP
tCSH
VIL-
tRCD
tCAS
tRSH
tCAS
tCP
tCRP
VIH-
CAS
VIL-
tASR
VIH-
Address
VIL-
tRAD
tRAH
tASC
ROW
ADDR.
tPRWC
tRAL
tCAH
tCAH
tASC
COL.
ADDR.
COL.
ADDR.
tRWL
tCWL
tCWL
tRCS
VIH-
WE
tCWD
tWP
tCWD
VIL-
tAWD
tCPWD
tOEH
tRWD
VIH-
OE
tOEA
tRAC
tOEA
tDH
VIL-
tCAC
tAA
tWP
tAWD
tCAC
tAA
tOED
tOEZ
tDS
tOED
tOEZ
tDH
VALID
DATA-OUT
VALID
DATA-IN
tDS
VI/OH-
DQ
VI/OL-
tCLZ
tCLZ
VALID
DATA-OUT
VALID
DATA-IN
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 12 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
CAS Before RAS Refresh Cycle
tRC
tRC
tRP
tRAS
tRAS
tRP
V IH-
RAS
V IL-
tCSR
CAS
tCHR
tRPC
tCSR
tCHR
tRPC
tCRP
V IHV IL-
RAS -Only Refresh Cycle
tRC
tRC
tRP
tRAS
RAS
tRAS
tRP
VIHVIL-
tCRP
CAS
tRPC
tCRP
VIHVIL-
tASR
tRAH
tASR
tRAH
VIH-
Address
ROW
ROW
VIL-
Hidden Refresh Cycle ( Read )
tRC
tRC
tRP
tRAS
RAS
tRAS
tRP
VIHVIL-
tRCD
tCRP
tRSH
tCHR
VIH-
CAS
VIL-
tRAD
tASR
Address
VIHVIL-
tRAL
tCAH
tASC
tCAH
COLUMN
ADDRESS
ROW
ADDRESS
tRCS
tWHR
VIH-
WE
tAA
VIL-
tOEA
VIH-
OE
VIL-
tCAC
tRAC
DQ
VIH-
tCLZ
OPEN
tOEZ
tOFF
DATA-OUT
VIL-
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 13 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Hidden Refresh Cycle ( Write )
NOTE : DOUT =Open
tRC
tRC
tRP
tRAS
RAS
tRAS
tRP
VIHVIL-
tCRP
tRCD
tRSH
tCHR
VIH-
CAS
VIL-
tRAD
tASC
Address
VIHVIL-
tCAH
tASC
ROW
ADDRESS
tCAH
COLUMN
ADDRESS
tWCS
tWCH
tWP
VIH-
WE
VIL-
VIH-
OE
VIL-
tDS
DQ
tDH
VIHDATA-IN
VIL-
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 14 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
CAS - Before RAS Refresh Counter Test Cycle
tRP
tRAS
VIH-
RAS VIL-
tCSR
tRSH
tCAS
tCPT
tCHR
VIHCAS VIL-
tRAL
tASC
AddressVIH-
COLUMN
ADDRESS
VIL-
Read Cycle
tCAH
tWRP
tAA
tCAC
tWRH
VIHWE VIL-
tRRH
tRCH
tRCS
tOEA
VIH-
OE VIL-
tOEZ
tCLZ
VOH-
DQ VOL-
Write Cycle
tCEZ
VALID DATA-OUT
tWRP
tWRH
tRWL
tCWL
tWCH
tWCS
VIHWE VIL-
tWP
VIH-
OE VIL-
tDS
VIHDQ VIL-
OPEN
tDH
VALID DATA-IN
Read-Modify-Write
tRCS
tAWD
tCWD
tCWL
tRWL
tWP
VIH-
WE VIL-
tCAC
tAA
tOEA
VIH-
OE VIL-
tOED
tCLZ
tOEZ
tDH
tDS
VI/OH-
DQ VI/OL-
VALID
DATA-OUT
VALID
DATA-IN
Don't Care
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 15 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Ordering Information
Part Number
SPEED
POWER
FEATURE
PACKAGE
GLT44016-25J4
GLT44016-28J4
GLT44016-30J4
GLT44016-35J4
GLT44016-40J4
GLT44016-50J4
GLT44016-25TC
GLT44016-28TC
GLT44016-30TC
GLT44016-35TC
GLT44016-40TC
GLT44016-50TC
25ns
28ns
30ns
35ns
40ns
50ns
25ns
28ns
30ns
35ns
40ns
50ns
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
EDO
EDO
EDO
EDO
EDO
EDO
EDO
EDO
EDO
EDO
EDO
EDO
40L 400mil SOJ
40L 400mil SOJ
40L 400mil SOJ
40L 400mil SOJ
40L 400mil SOJ
40L 400mil SOJ
44L 400mil TSOP
44L 400mil TSOP
44L 400mil TSOP
44L 400mil TSOP
44L 400mil TSOP
44L 400mil TSOP
Parts Numbers (Top Mark) Definition :
GLT 4 40
4 : DRAM
6 : Standard
SRAM
7 : Cache SRAM
8 : Synchronous
Burst SRAM
-SRAM
064 : 8K
256 : 256K
512 : 512K
100 : 1M
-DRAM
10 : 1M(C/EDO)*
11 : 1M(C/FPM)*
12 : 1M(H/EDO)*
13 : 1M(H/FPM)*
20 : 2M(EDO)
21 : 2M(FPM)
40 : 4M(EDO)
41 : 4M(FPM)
80 : 8M(EDO)
81 : 8M(FPM)
*See note
16 - 40 J4
CONFIG.
04 : x04
08 : x08
16 : x16
32 : x32
VOLTAGE
Blank : 5V
L : 3.3V
M : Mix Voltage
SPEED
-SRAM
12 : 12ns
15 : 15ns
20 : 20ns
70 : 70ns
-DRAM
25 : 25ns
30 : 30ns
35 : 35ns
40 : 40ns
45 : 45ns
50 : 50ns
60 : 60ns
PACKAGE
T : PDIP(300mil)
TS : TSOP(Type I)
TC : TSOP(Type ll)
PL : PLCC
FA : 300mil SOP
FB : 330mil SOP
FC : 445mil SOP
J3 : 300mil SOJ
J4 : 400mil SOJ
P : PDIP(600mil)
Q : PQFP
TQ : TQFP
Note : CÙCDROM , HÙHDD.
Example :
1.GLT710008-15T 1Mbit(128Kx8)15ns 5V SRAM PDIP(300mil)Package type.
2.GLT44016-40J4 4Mbit(256Kx16)40ns 5V DRAM SOJ(400mil)Package type.
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 16 -
G -LINK
GLT44016
256K X 16 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
Aug, 2000(Rev.3.1)
Package Information
40/44 Lead Thin Small Outline Package SOJ
40/44 Lead Thin Small Outline Package TSOP(Type II)
G-Link Technology Corporation
G-Link Technology Corporation,Taiwan
2701Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
6F, No. 24-2, Industry E. RD. IV, Science Based
Industrial Park, Hsin Chu, Taiwan.
- 17 -
Similar pages