SL Power GNT200 Universal input power supply Datasheet

GNT200
Front End Series 200W AC/DC
Universal Input Power Supply
2 Year Warranty
•Wide Range Input 100-240 VAC with PFC
•Inhibit, Enable, Power Signals and Remote Sense Standard
•Power Density 10-13W/in³
•Compact (3.0” x 5.0” x 1.25”)
•High Efficiency: 90% Typical
•Main Output and Two Auxiliary Outputs
•Conducted EMI meets Class B
nd
•Approved to CSA/EN/IEC/UL 60950-1, 2
Edition for ITE
•Approved to EN/IEC/UL60601-1 and CSA 22.2 No. 601 for Medical
•Also Available in Class II (G2T200)
•CB Report Available (for IEC60601-1 standard)
Specifications
AC Input
Input Current
Inrush Current
Input Fuses
All Specifications are typical at nominal input, full load at 25°C unless otherwise stated.
100-240VAC, 50/60 Hz, single phase
80-270VAC, 45-65 Hz max
120VAC: 3A. 230VAC: 1.5A
Limited by internal thermistor. The inrush at 240Vac,
averaged over the first AC half-cycle under cold start
conditions will not exceed 38A.
F1 and F2, 4A/250V
Power Factor
Leakage Current
Output Power
Peak Output Power
Output Voltage
Voltage Adjustability
Minimum Load
Total Regulation
0.98 typical, 0.96 minimum
100µA at 120VAC NC, 400µA at 264VAC, SFC
200W continuous with 200lfm airflow
See chart for convection ratings
240W for 1 minute, 10% duty cycle
See chart
Adjustable potentiometer, capable of
±5% change from the nominal setting
Not required
See chart
Transient Response
500µs to 1%, 50% load step, ∆i/∆t < 0.2A/µs
Maximum voltage deviation is 3.5%
Temperature Coefficient
0.03% per °C typical on all units
Operating Altitude
-500 to 10,000 ft
Non-operating Altitude
Vibration
-500 to 40,000 ft
5 Hz – 500 Hz, 5 grms
Turn On Time
500 ms max
Hold-up Time
See chart
Thermal Considerations
Over/Undershoot
Overload Protection
Cycling type, 250W nominal limit
Overvoltage Protection
Ripple and Noise
See chart
1% pk-pk max., 20MHz BW,
0.1µF and 10 µF caps on probe
CSA/EN/IEC/UL 60950-1, 2nd Edition
ITE Safety Standards
Medical Safety Standards
Switching Frequency
EN/IEC/UL 60601-1, CSA22.2 No. 601-1
Output: 195kHz ±12kHz, PFC: 130kHz
MTBF
300K hours per Telcordia
Overtemperature Protection
Efficiency
Keeping the following components below
these temps indicates sufficient cooling:
Q1: 90°C max., T4: 110°C max
3.5% max
Automatic
90% typical at 230VAC, 87% typical at 120VAC
Operating Temperature
0 to 70°C (see chart)
Storage Temperature
Relative Humidity
-40 to +85°C
5% to 95%, non-condensing
Shock
MIL-STD-810E, 516.4 part IV
Model Number Key
GNT 2 XX X G
RoHS Com pliant
Enclosure Options: Blank - no enclosure; F = Fan Cover w ith "U" channel; L = L
bracket, no cover; T = Slotted cover w ith U channel; U = U channel, no cover.
Output Voltage: (See m odels chart below )
Output Pow er (Watts): "2" = 200W
Product Fam ily (GNT = Class I input, G2T = Class II input)
______________________________________________________________________________________________________________________________ 1 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com
GNT200
Front End Series 200W AC/DC
Universal Input Power Supply
Model
Number
GNT212G
GNT215G
GNT218G
GNT224G
GNT228G
GNT236G
GNT248G
Notes:
1.
2.
3.
Volts (V) ┌──── ──────
2 Year Warranty
Output Current
─────────────┐
100Vac Convection 240Vac Convection 90-270VAC Fan Cooled
12V
15V
18V
24V
28V
36V
48V
8.3A
6.7A
5.6A
4.2A
3.6A
2.5A
1.9A
12.5A
10.0A
8.3A
6.3A
5.4A
3.9A
2.9A
16.7A
13.3A
11.1A
8.3A
7.1A
5.6A
4.2A
Ripple
& Noise
120mV
150mV
180mV
240mV
280mV
360mV
480mV
Total
Regulation
±2%
±2%
±2%
±2%
±2%
±2%
±2%
OVP
Threshold
14.0 ± 1V
17.6 ± 1V
20.8 ± 1V
27.5 ± 1V
32.0 ± 1V
42.0 ± 1V
55.0 ± 1V
When the input voltage is <90Vac, derate output power by approximately 20%.
Convection ratings shown are for 40°C ambient. Derate load 2.5%/°C to 70°C.
Fan cooled rating of 200W @ 50°C requires 200lfm of airflow over the unit.
General Specifications (continued from p. 1)
Signals
PS Off:
Inhibit:
Pwr OK:
Pwr OK:
DC OK:
Aux. Output:
Aux. Output:
Conducted Emissions:
Line Freq. Harmonics:
Voltage Fluctuations:
Static Discharge:
RF Field Susceptability:
Fast Transients/Bursts EFT:
Surge Susceptability:
Conducted Immunity:
Power Freq. Mag. Field:
Voltage Dips Immunity:
EMC/EMI Compliance
High to Inhibit
Low to Inhibit
Goes high 100ms to 200 ms after DC OK signal
Power fail low – 4ms warning
High when output is >92% of nominal
12Vdc @ 250mA
5Vdc @ 100mA, always on
EN55011/22, Class B; FCC Class B
EN61000-3-2 Class A
EN61000-3-3
EN61000-4-2
EN61000-4-3 3 V/meter
EN61000-4-4, 2 kV, 5 kHz – criteria B
EN61000-4-5, criteria B
EN61000-4-6, 3 Vrms
EN61000-4-8, 3 A/m
EN61000-4-11 Contact factory
GNT200 Series Typical Holdup & Warning Time vs Output Power
200
180
160
Time (milliSeconds)
140
120
100
Tholdup (mS)
Twarning (mS)
80
60
40
20
0
200
150
100
Output Power
50
25
______________________________________________________________________________________________________________________________ 2 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com
GNT200
Front End Series 200W AC/DC
Universal Input Power Supply
2 Year Warranty
Mounting Options
GNT200
WEIGHT: 0.68 Lbs. (350g)
CONNE CTOR INFORM ATION
J1:
AC INPUT - A MP# 640445-3
PIN 1:
AC LINE
PIN 2:
AC NEUT RAL
J2:
DC OUTP UT
PIN 1:
PIN 2:
PIN 3:
PIN 4:
PIN 5:
PIN 6:
- AM P# 64044 5-6
+V out
+V out
+V out
COMMON
COMMON
COMMON
Q1
T4
J3:
FAN OUT PUT - AM P# 6404 56-2
PIN 1:
+12Vdc @ 0.25A
PIN 2:
FAN RTN (COMMO N)
J4:
SIGN ALS - MOLE X 22-05-7085
PIN 1:
PS OFF
PIN 2:
INHI BIT
PIN 3:
PW R O K
PIN 4:
DC OK
PIN 5:
SIGN AL RTN (COMMON)
PIN 6:
+5Vdc @ 0.1A
PIN 7:
-SE NSE
PIN 8:
+SE NSE
J1:
MOLE X 09-50-3031, PI NS: 08-52-0112
J2:
MOLE X 09-50-3061, PI NS: 08-52-0112
J3:
AMP 1375 820-2, PINS : 1375813 -3
J4:
MOLE X 50-37-5083, PI NS: 08-70-1040
MATING CO NNECTORS:
GNT200 Output Power vs. Line Voltage & Temperature
200
5 0 ° C w / 2 0 0 lfm a irfl o w
180
2 5 ° C c o n v e c tio n
Power Rating (Watts)
160
140
120
5 0 ° C c o n v e c ti o n
4 0 ° C c o n v e c ti o n
100
80
60
40
20
0
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
In p u t V o lts AC
Data Sheet © 2011 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication.
SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev. 2-17-2011
______________________________________________________________________________________________________________________________ 3 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com