Hirose GT7A-2022SCF Coaxial cable connection of antennas, sensors, and communication trunk line Datasheet

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
Termination of coaxial cables in automotive, medical and instrumentation applications
utilizes a single motion to crimp the center conductor, shield and outer Insulator.
GT1 Series
— Connectors for coaxial cables —
<Several types and configurations: In-line, board mounted, combinations of
coaxial cable with signal/power. Multi-position.>
Features
Cost efficient termination
Highly efficient and reliable single motion crimp termination allows high volume production with semiautomatic equipment.
Lock-release latching system
Shock / vibration resistant electrical connections
Verification of the full contact insertion
Excellent shielding effects.
Excellent High Frequency Performance
Refer to V.S.W.R. data on the following pages.
2003.6
BTest Data (Using Semi-rigid Cable)
High Frequency Characteristics (V.S.W.R.)
Note: Data taken using fully assemblied and connected GT1-1S-HU and GT1-1P-DSA.
BDiagram of GT1 In-line Type Structure
1
2
3
4
5
6
7
8
2
Part Number
GT1-1P-HU
GT1-1P-2428/1.6C
GT1-1S-HU
GT1-1S-2428/1.6C
Part
Housing
Insulator
Crimp terminal
Outer terminal
Housing
Insulator
Crimp terminal
Outer terminal
Number Used
1
1
1
1
1
1
1
1
Material
PA(UL94V-0)
PBT(UL94V-0)
Brass
Brass
PA(UL94V-0)
PBT(UL94V-0)
Phosphor bronze
Brass
Finish
------Tin plating
Tin plating
------Tin plating
Tin plating
BTermination sequence
Coaxial Cable Terminal Finish Diagram
Strip Length
Part Number
GT1-1S-2428 / 1.6C
GT1-1P-2428 / 1.6C
GT1-1S-30 / 1.6C
GT1-1P-30 / 1.6C
GT1-1S-2022 / 2.9C
GT1-1P-2022 / 2.9C
CL No.
751-0001-3
751-0002-6
751-0029-2
751-0030-1
751-0015-8
751-0014-5
L1
L2
L3
3.8
6
10.5
4.9
6.8
11.3
Part Number
GT1-1S-30 / 2.9C
GT1-1P-30 / 2.9C
GT1-1S-2428 / F5C
GT1-1P-2428 / F5C
GT1-1S-30 / F5C
GT1-1P-30 / F5C
CL No.
751-0032-7
751-0031-4
751-0033-0
751-0034-2
751-0037-0
751-0038-3
L1
L2
L3
4.9
6.8
11.3
1 Crimp the cable to the terminal.
2 Insert the terminal in the housing until is fully locked.
3 Completion
3
Terminals for coaxial shielded cable
F Connector Terminals
Indication of
Conductor Size (AWG)
Part Number
GT1-1S-2428 / 1.6C
GT1-1S-30 / 1.6C
GT1-1S-2022 / 2.9C
GT1-1S-30 / 2.9C
* GT1-1S-2428 / F5C
* GT1-1S-30 / F5C
GT1-1S-2428 / F4C
CL No.
Conductor Size
(AWG)
751-0001-3
751-0029-2
751-0015-8
751-0032-7
751-0033-0
751-0037-0
751-0046-1
#24 to 28 or equivalent
#30 or equivalent
#20 to 22 or equivalent
#30 or equivalent
#24 to 28 or equivalent
#30 or equivalent
#24 to 28 or equivalent
Inner Insulator
Diameter
Outer
Diameter
Packaging
1.5 to 2.0mm 2.6 to 3.4mm
1,200
2.8 to 3.5mm
2.5 to 3.5mm
4.6 to 5.0mm
0,800
4.0mm
Item
Insulator
Crimp terminal
Outer terminal
Material
PBT
Brass
Brass
Finish
Color: Dark gray
Tin plating
Tin plating
Note: Products marked with an asterisk (*) indicate polyethylene foam insulation.
M Connector Terminals
Indication of
Conductor Size (AWG)
Part Number
GT1-1P-2428 / 1.6C
GT1-1P-30 / 1.6C
GT1-1P-2022 / 2.9C
GT1-1P-30 / 2.9C
* GT1-1P-2428 / F5C
* GT1-1P-30 / F5C
GT1-1P-2428 / F4C
CL No.
Conductor Size
(AWG)
751-0002-6
751-0030-1
751-0014-5
751-0031-4
751-0034-2
751-0038-3
751-0047-4
#24 to 28 or equivalent
#30 or equivalent
#20 to 22 or equivalent
#30 or equivalent
#24 to 28 or equivalent
#30 or equivalent
#24 to 28 or equivalent
Inner Insulator
Outer
Diameter
Diameter
Packaging
1.5 to 2.0mm 2.6 to 3.4mm
0,800
2.8 to 3.5mm
2.5 to 3.5mm
4.6 to 5.0mm
4.0mm
Note: Products marked with an asterisk (*) indicate polyethylene foam insulation.
4
0,600
Item
Insulator
Crimp terminal
Outer terminal
Material
PBT
Brass
Brass
Finish
Color: Dark gray
Tin plating
Tin plating
For Single-Conductor coaxial shielded cable
F Connectors
Housing
Part Number
GT1-1S-HU
CL No.
751-0003-9
Material
PA
Color
Light gray
Material
PA
Color
Light gray
M Connectors
Housing
Part Number
GT1-1P-HU
CL No.
751-0004-1
Panel Housing
Part Number
CL No.
GT1-1PP-HU
751-0007-0
Item
Housing
Ground plate
Press fitting nut
Material
PA
Brass
Brass
Finish
---Tin plating
Nickel
Color
Light gray
-------
5
Printed Circuit Type (Right angle)
BRecommended Board Mounting Pattern
For outer conductor
For inner conductor
Part Number
CL No.
GT1-1P-DS
751-0006-7
Item
Housing
Insulator
0.64X1.1 Terminal
Outer terminal
Ground terminal
Material
PBT
PBT
Brass
Brass
Stainless
Finish
------Tin plating
Tin plating
----
Color
Light gray
Dark gray
----------
Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm)
Printed Circuit Type (Straight Dip Type)
BRecommended Board Mounting Pattern
For outer conductor
For inner conductor
Part Number
CL No.
GT1-1P-DSA
751-0005-4
Item
Housing
Insulator
0.64X1.1 Terminal
Outer terminal
Material
PBT
PBT
Brass
Brass
Finish
------Tin plating
Tin plating
Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm)
6
Color
Light gray
Dark gray
-------
For Single-Conductor coaxial shielded cable
F Connectors
Housing (Integrated retainer type)
BShown with inserted retainer
Part Number
GT1K-1S-HU
CL No.
751-0016-0
Material
PBT
Color
Light gray
Note: Mates only with GT1K-1P-DS and GT1K-1PA-DS.
* Refer to Page 14 for use of the GT1K-1P-HU retainer.
M Connectors
BRecommended Board
Mounting Pattern
Printed Circuit Board Type
(Right-angle Dip Top Lock Type)
For outer conductor
For inner conductor
Part Number
CL No.
GT1K-1P-DS
751-0017-3
Item
Housing
Insulator
0.64X1.1 Terminal
Outer terminal
Cover
Material
PBT
PBT
Brass
Brass
Stainless
Finish
------Tin plating
Tin plating
Nickel
Color
Light gray
Dark gray
----------
Note 1: Mates only with GT1K-1S-HU.
Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm)
Printed Circuit Board Type
(Right-angle Dip Side Lock Type)
BRecommended Board
Mounting Pattern
For inner conductor
Part Number
GT1K-1PA-DS
CL No.
Item
Housing
Insulator
751-0035-5
0.64X1.1 Terminal
Outer terminal
Material
PBT
PBT
Brass
Brass
Finish
Color
---Light gray
---Dark gray
Tin plating
---Tin plating
----
Note 1: Mates only with GT1K-1S-HU.
Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm)
For outer conductor
Panel
7
BMethod of Using the GT1K-1S Retainer
a. Insert so that the terminal
locking tab is inserted
between the top surface
of the terminal and the
housing.
b. Push in while changing
the angle of the retainer
until the front surface
comes to a stop.
c. Press the rear portion of
the retainer and snap it
into the locked position.
d. If locking is not complete,
press the rear portion of
the retainer again while
pulling it backward.
* Check that all locations are locked.
8
Two-position type-Each Single-Conductor coaxial Cable
F Connectors
Housing
Part Number
CL Number
GT1-2S-HU
(20) 751-0011-7-20
GT1-2S-HU
(20) 751-0011-7-20
GT1-2S-HU
(21) 751-0011-7-21
Note: Retainer is optional.
Material
PBT
Color
Light gray
Orange
Blue
Retainer (Used with GT1-2S-HU)
A Configuration
Part Number
A Configuration Part Number
CL No.
Material
GT1-2S-33R 751-0045-9
GT1-2S-53R 751-0043-3
GT1-2S-55R 751-0044-6
PBT
Color
BShown with inserted retainer
Cable Dia.
o/ A o/ B
White
o/ 3
o/ 3
Dark gray
o/ 5
o/ 3
Light blue
o/ 5
o/ 5
Note 1: This item should be mounted to the GT1-2PP-HU housing after the insertion of terminals.
Note 2: Retainer is optional.
Retainer (used with GT1-2S-HU and GT1-2PP-HU)
BGT1-2S-HU
Shown with temporarily inserted retainer
BGT1-2PP-HU
Shown with temporarily inserted retainer
Part Number
CL Number
Material
Color
GT1-2P/S-R
751-0013-2
PBT
Dark gray
Note: Mount this item after provisional insertion into the housing, or after terminal insertion.
9
M Connectors
Housing
Mounting bracket
attachment side
BRecommended Mounting Bracket
Dimensions (T=1.5mm)
Ground terminal
Tin plating
Part Number
GT1-2PP-HU(10)
GT1-2PP-HU(10)
GT1-2PP-HU(20)
GT1-2PP-HU(21)
GT1-2PP-HU(40)
GT1-2PP-HU(41)
CL No.
751-0010-4-20
751-0010-4-10
751-0010-4-20
751-0010-4-21
751-0010-4-40
751-0010-4-41
Color
Light gray
Light gray
Orange
Blue
Orange
Blue
Remarks
With ground terminal
Without ground terminal
With ground terminal
With ground terminal
Without ground terminal
Without ground terminal
Item
Material
Housing
PBT
Ground terminal
Brass
Finish
Color: Light gray
Color: Orange
Color: Blue
Tin plating
Note: Retainer is optional.
Retainers (Used with GT1-2PP-HU)
A Configuration
Part Number
BShown with inserted retainer
Bracket Mounting portion
A Configuration Part Number
CL No.
GT1-2PP-33R 751-0042-0
Color
White
Cable Dia.
o/ A o/ B
o/ 3
o/ 3
Color
White
GT1-2PP-53R 751-0040-5 Dark gray o/ 5 o/ 5
PBT
Dark gray
GT1-2PP-55R 751-0041-8 Light blue o/ 5 o/ 3
Light blue
Note 1: This item should be mounted to the GT1-2PP-HU housing after the insertion of terminals.
Note 2: Retainer is optional.
10
Material
Power Supply Terminals
F Connector Terminals
Conductor Size Inner Insulator Dimension A Packaging Material
Finish
(AWG)
Diameter
GT7-2022SCF
757-0001-1
#20 to 22
1.4 to 2.4mm
5,000
19
Copper alloy Tin plating
GT7A-2022SCF 757-0003-7
#20 to 22
2.6 to 3.1mm
3,000
Note 1: Sold by the reel. (See above table for number of Packaging.)
Note 2: This component is used only with applicable HRS housings.
Part Number
CL No.
M Connector Terminals
Part Number
GT7-2022SCF
GT7A-2022SCF
Conductor Size Inner Insulator Dimension A Packaging Material
Finish
(AWG)
Diameter
757-0001-1
#20 to 22
1.4 to 2.4mm
5,000
19
Copper alloy Tin plating
757-0003-7
#20 to 22
2.6 to 3.1mm
3,000
CL No.
Conductor Size Inner Insulator Packaging
(AWG)
Diameter
#16 to 18
1.8 to 2.7mm
3,000
GT7-1618PCF
757-0002-4 #20 to 22
1.4 to 2.4mm
5,000
GT7-2022PCF
2.6 to 3.1mm
3,000
GT7A-2022PCF 757-0004-0 #20 to 22
Note 1: Sold by the reel. (See above table for number of Packaging.)
Note 2: This component is used only with applicable HRS housings.
Part Number
CL No.
Material
Finish
Brass
Tin plating
* Reserved for
product expansion
11
Combination Type (One Single-Conductor Coaxial Cables + One Power contact)
F Connectors
Housing
Part Number
CL No.
GT1-1/1S-HU
751-0026-4
Note: Retainer is optional.
Material
PBT
Color
Light gray
Retainer (Used with GT1-1/1S-HU)
Part Number
CL Number
Material
Color
GT1-1/1S-R
751-0028-0
PBT
Dark gray
Note: Mount this item after provisional insertion into the housing, or after terminal insertion.
12
M Connectors
Housing
Mounting bracket
attachment side
BRecommended Mounting Bracket Dimensions (T=1.5mm)
Tin plating
Part Number
CL No.
GT1-1 / 1PP-HU(00)
GT1-1 / 1PP-HU(10)
GT1-1 / 1PP-HU(11)
751-0025-1-10
751-0025-1-10
751-0025-1-11
Mounting bracket
attachment side
1.5mm
1.5mm
1.0mm
Remarks
With ground terminal
Without ground terminal
With ground terminal
Item
Material
Housing
PBT
Ground terminal Phosphor bronze
Finish
Light gray
Tin plating
Note: Used with separate retainer (GT1-1/1PP-R).
Retainer (exclusively for GT1-1/1PP-HU)
Part Number
GT1-1/1PP-R
CL Number
751-0027-7
Material
PBT
Color
Dark gray
Note: Mount this item after provisional insertion into the housing, or after terminal insertion.
13
Combination Type (Two Single-Conductor Coaxial Cables + One Power contact)
F Connectors
Housing
Part Number
CL No.
Material
Color
GT1-2/1S-HU
751-0019-9
PBT
Light gray
Note1: Mates only with GT1-2/1PP-DS and GT1-2/1PP-HU.
Note2: Used with separate retainer (GT1-2/1S-R).
Retainer (used with GT1-2S-HU and GT1-2PP-HU)
Part Number
CL No.
Material
Color
GT1-2/1S-R
751-0021-0
PBT
Dark gray
Note: Mount this item after provisional insertion into the housing, or after terminal insertion.
14
M Connectors
Housing
BRecommended Mounting Bracket
Dimensions (T=1.5mm)
Mounting bracket
attachment side
Tin plating
Ground terminal
Part Number
CL No.
GT1-2/ 1PP-HU(00)
GT1-2/ 1PP-HU(10)
GT1-2/ 1PP-HU(11)
751-0018-6-10
751-0018-6-10
751-0018-6-11
Mounting bracket
attachment side
1.5mm
1.5mm
1.0mm
Remarks
With ground terminal
Without ground terminal
With ground terminal
Item
Material
Housing
PBT
Ground terminal Phosphor bronze
Finish
Light gray
Tin plating
Note1: Mates only with GT1-2/1S-HU.
Note2: Used with separate retainer (GT1-2/1PP-R).
Retainer (used with GT1-2/1PP-HU)
Part Number
CL Number
Material
Color
GT1-2/1PP-R(22) 751-0020-8-22
PBT
Dark gray
Note: Mount this item after provisional insertion into the housing, or after terminal insertion.
BRecommended Board
Mounting Pattern
Printed Circuit Board Type
BRecommended Panel
Cut-out
Ground terminal
For inner conductor
Ground terminal
Ground terminal
For outer conductor
Panel
Part Number
CL No.
GT1-2/1PP-DS
751-0022-3
Part
Material
Housing
PBT
Ground terminal
Phosphor bronze
Ground plate
Brass
Tub terminal for DS 070
Brass
0.64X1.1 Terminal
Brass
Insulator
PBT
Outer terminal
Brass
Finish
---Tin plating
Tin plating
Tin plating
Tin plating
---Tin plating
Board
Color
Light gray
------------Dark gray
----
Note1: Mates only with GT1-2/1PP-DS and GT1-2/1PP-HU.
Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 1.6mm)
15
Products Listed Below are of the Combination Type (Two Terminals for Use with Single-Conductor Shielded
Cable + One Power Supply Terminal) with Key Positions that Differ from the Products Listed on Previous Pages
F Connectors
Housing
Part Number
CL No.
GT1-2/1S-HU(A)(21)
751-0024-9-21
GT1-2/1S-HU(A)(21)
751-0024-9-21
Note1: Mates only with GT1-2/1P-DS.
Note2: Used with separate retainer.
Material
PBT
PBT
Color
Light gray
Blue
M Connector
Printed Circuit Board Type
BRecommended Board
Mounting Pattern
Board
Ground terminal
For inner conductor
For outer conductor
Panel
Item
Material
Housing
PBT
0.64X1.1 Terminal
Insulator
Outer terminal
Tub terminal for DS 070
Brass
PBT
Brass
Brass
Finish
------Tin plating
---Tin plating
Tin plating
Part Number
CL No.
Color
GT1-2/1P-DS(21) 751-0023-6-21
Light gray
GT1-2/1P-DS(21) 751-0023-6-21
Blue
Note1: Mates only with GT1-2/1S-HU(A).
Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 1.6mm)
16
BRecommended Panel
Cut-out
Color
Light gray
Blue
---Dark gray
-------
BMating, Cross-Sectional View
Examples of Printed Circuit Board Type and Cable Type
Mating, Top View
Cross Section AA
GT1-2/1P-DS+GT1-2/1S-HU
(A)
Part Number
Part
Number Used Material
Finish
PBT
Housing
UL94V-0
1
1
PBT
Insulator
UL94V-0
2
2
GT1-2/1P-DS(A)
Brass Tin plating
2
0.64 X 1.1 terminal
3
Brass Tin plating
2
Outer terminal
4
PBT
1
Housing
UL94V-0
5 GT1-2/1S-HU(A)
PBT
1
Retainer
UL94V-0
6 GT1-2/1S-HU(A)
PBT
2
Insulator
UL94V-0
7
2
Phosphor bronze Tin plating
8 GT1-1S-2428/1.6C Crimp terminal
2
Outer terminal
Brass Tin plating
9
Example of Cable-to-Cable Type
The coupled, cross-sectional view of the GT7 terminals of the GT1-2/1 Series appears below.
Cross Section AA
Currently, the GT7 Series terminals are used for the power supply of the GT1 Series combination type.
Part Number
GT1-1/1S-HU
GT1-2/1S-HU
GT1-1/1PP-HU
GT1-2/1PP-HU
Terminal
Mating, Top View
Part Number
1 GT1-2/1PP-HU
2 GT1-2/1PP-R
GT7-2022SCF、GT7A-2022SCF
3 GT7-2022PCF
4 GT1-2/1S-HU
GT7-2022PCF、GT7A-2022PCF
5 GT1-2/1S-R
6 GT7-2022SCF
17
Accessories
Brackets (for M Connector Housing)
Part Number
CL No.
Material
Finish
GT-BK(01)
751-0039-6-22
Tin plating
SPCC
GT-BK(01)
751-0039-6-01
Zinc plating
Note 1: This product can be attached to GT1-1PP-HU, GT1-1/1PP-HU, and GT1-2/1PP-HU.
Note 2: Please use the tin plated item when making a ground connection.
F Terminal Shield Cover
Mounted Condition Installed
Part Number
CL No.
GT1-1S-1.6CSB
751-0009-5
Item
Material
Top Shield Cover
SPCC
Bottom Shield Cover
Note: This product cannot be used with GT1K-1S-HU.
Finish
Tin plating
Zinc plating
M Terminal Shield Plate
Mounted Condition Installed
Part Number
18
CL No.
Item
Material
Finish
Top Shield Cover
GT1-1P-1.6CSB
751-0008-2
Brass
Tin plating
Bottom Shield Cover
Note: The product normally has sufficient performance without using the shield plate; however, when used in especially high frequency bands (e.g.,
1 GHz and higher), use of the shield plate is recommended so that even higher shielding effectiveness may be obtained.
BTermination Tools
User's manuals are available. Please ask your Hirose Electric account representative.
Automatic Crimping Machine
Specifications
Item
Specification
Stroke Length
Number of strokes
Specification
30mm
200spm(50Hz)
Weight
75kg
Motor
0.2kW
Crimping speed
Remarks
1.5ton
240spm(60Hz)
AC100V
2000 to 4000 per day
Part Number CM-105
Hand Tool
Hand Press
*Crimp height setting tables are available for each cable type. Please contact your nearest Hirose Electric account representative. Different cables will
require different crimp height settings.
19
BTerminal Extraction Tool
1) For one lance
1 Insert the extraction tool from the coupling end.
2 Push the lance upward and pull out the terminal.
Part Number
GT-PO(A)
CL No.
780-0006-2
Used with connectors
GT1K-1S-HU GT1-2S-HU GT1-2PP-HU GT1-1/1S-HU
GT1-1/1PP-HU GT1-2/1S-HU GT1-2/1PP-HU GT1-2/1S-HU(A)
2) For two lances
1 Insert the extraction tool from the coupling end.
2 Push and separate both lances and pull out the terminal.
20
Part Number
CL No.
GT1-C-PO
902-5020-1
Used with connectors
GT1-1S-HU
GT1-1P-HU GT1-1PP-HU
Similar pages