TDK GWS250-24

GWS Series
Single Output 250 & 500W Power Supplies
u High Efficiency, up to 93%
u 1.6" high (For 1U racking)
u Wide Range AC Input
u 250W Convection Cooled
u Five year warranty
Key Market Segments & Applications
GWS500 Shown
Light Industrial
Automated Service
Test & Measurement
Kiosks
Specifications
MODEL
ITEMS
AC Input Voltage (300VAC for 5s)
VAC
Input Frequency
Hz
DC Input Voltage
VDC
Inrush Current (cold start)
A
Power Factor
(1)
Input Current (115/230VAC)
A
Temperature Coefficient
°C
Overcurrent Protection
Overvoltage Protection
(2)
V
Overtemperature Protection (2)
Hold Up Time (115 / 230V input)
ms
Leakage Current (240VAC 60Hz)
mA
Remote Sense
Remote On/Off
Standby Input Power Draw
W
5V Standby (always on)
DC Good
LED Indicator
Output Remote Programming
Operating Temperature
°C
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Immunity
Safety Agency Approvals
Conducted & Radiated EMI
Weight (Typ)
Size (LxWxH
Warranty
°C
g
in
yrs
GWS250
GWS500
85 - 264VAC
47 - 63Hz
120 - 373VDC
20A at 115VAC, 40A at 230VAC
Meets EN61000-3-2 (Typical PF 0.98/0.95)
3.0 / 1.4
5.5 / 2.7 (4.5 / 2.3 for 5V model)
<0.02%/°C (0 - 50°C)
>105% of nominal or >101% of peak. 5V-12V hiccup style, 24V-48V Constant current style
5V: 5.75 - 6.75V, 7.5V: 8.6 - 10.1V, 12V: 13.8 - 16.2V24V: 30.3 - 35.5V, 36V: 41.4 - 48.6V, 48V: 60 -69.6V
Yes
16ms
<0.75mA
No
Yes
Active Low
<0.5W
5V 0.3A
DC Good, open collector signal, High on Fail
Green LED = On
See installation manual for details
-25 to +70°C. Derate linearly to
-25 to +70°C. Derate linearly to
50% load from +50 to +70°C
TBD% load from +50 to +70°C
-30 to +85°C
30 - 90% RH (non condensing)
10 - 95% RH (non condensing)
Convection
Internal fan
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz: 19.6m/s2 constant sweep 1 min X, Y, Z for 1 hour
< 196.1 m/s2 (20G)
IEC61000-4-2 (lv 2, 3), -3 (lv3), -4 (lv 3), -5 (lv 4), -6 (lv 3), -8 (lv 4), -11
UL60950-1, CSA C22.2 No 60950-1-07 (cUL), EN60950-1 2nd Edition, IEC60950-1, CE Mark
EN55022-B, FCC-B
850
1020
7.8 x 4.1 x 1.61"
8.6 x 4.1 x 1.61"
Five Years
(1) 115 / 230VAC input
(2) Recycle AC, or use remote on/off to reset
Note: Green shade = preliminary
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
53
GWS Series
Model Selector
Model
GWS500-5
GWS500-7.5
GWS250-12
GWS500-12
GWS250-24
GWS500-24
GWS250-36
GWS500-36
GWS250-48
GWS500-48
Voltage
(V)
5V
7.5V
12V
12V
24V
24V
36V
36V
48V
48V
Adjust
Range
(V)
4.75 - 5.5
6.75 - 8.25
10.8 - 13.2
10.8 - 13.2
22 - 28.8
22 - 28.8
32 - 40
32 - 40
42 - 57.6
42 - 57.6
Max
Current
(A)
Peak Curr.
<10s,<35%
DC (A)
Load
Reg.
(mV)
Line
Reg.
(mV)
Ripple
Noise
(mV)
Efficiency
(typ) %
(230VAC)
80
67.2
21
42
10.5
21
7
14
5.3
10.5
12.5
25.0
8.4
16.7
-
50
70
96
96
192
192
288
288
384
384
25
35
48
48
96
96
144
144
192
192
150
150
150
150
240
240
360
360
480
480
85
88
92
90
92
91
93
91
93
91
GWS500 Outline Drawing
Other Industrial Products
LS25 - 200
HWS15 - 1800
SWS300 - 1000
CSS500
54
25W to 200W low cost
15W to 1800W limited lifetime warranty
300W to 1000W single output
360W to 500W medical
For Additional Information, please visit
us.tdk-lambda.com/lp/products/gws-series.htm
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
Revision A4: July 2011