Crydom H12D4825FPH Panel mount Datasheet

H12 Series
•
•
•
•
Ratings from 25A to 125A @ 48-530 V AC
SCR output for heavy industrial loads
AC or DC control
Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage
4-32 VDC
25A
50A
75A
90A
125A
H12D4825
H12D4850
H12D4875
H12D4890
H12D48125
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [mArms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I2 t for Fusing (8.3 msec) [A2 sec]
Minimum Power Factor (with Maximum Load)
25A
50A
75A
90A
125A
48-530
1200
10
500
25
150
250
1.6
1.02
260
48-530
1200
10
500
50
150
625
1.6
0.63
1620
48-530
1200
10
500
75
150
1000
1.6
0.31
4150
48-530
1200
10
500
90
150
1200
1.6
0.28
6000
48-530
1200
10
500
125
150
1750
1.7
0.22
12700
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS (1)
Description
DC Control
Control Voltage Range
Maximum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
4-32 VDC
4.0 VDC
1 .0 VDC
15 mADC (5)
See Note 5
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Terminals
Recommended Terminal Screw Torque Range:
Fastons:
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
3 oz (86.5 g)
Thermally conductive Epoxy
Screw and saddle Clamps Furnished, Unmounted
6-32 Screws - 10 in/lbs. 8-32 & 10-32 Screws - 20 in. lbs. (Screws dry without grease)
Single pair (up to 25A) Double pair* (50A model only) Caution: User must connect to both pairs
GENERAL NOTES
1) All parameters at 25°C and per section unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Heat sinking required, for derating curves see page 2.
4) Turn-on time for DC control random turn-on versions is 0.02 msec
5) Input circuitry version incorporates active current limiter.
6) Only 125A model CE Compliant.
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
Rev. 013009
ANNEX - ENVIROMENTAL INFORMATION
Similar pages