CANDD HB01U15S15 1 watt unregulated dc/dc converter Datasheet

Product Data Sheet
1 WATT UNREGULATED
DC/DC CONVERTERS
HB01U
APPLICATIONS
●
●
●
●
●
●
●
INDUSTRIAL PROCESS CONTROL
DC MOTOR DRIVE
INTRINSIC SAFETY SYSTEMS
GROUND LOOP ELIMINATION
MEDICAL EQUIPMENT
PORTABLE TEST EQUIPMENT
DATA ACQUISITION
DESCRIPTION
FEATURES
The HB01U Series offers a wide selection of input and
output voltages to choose from. Each model is offered in
a 24-pin DIP or SMD package and has an input to output
isolation rating of 2500Vrms making it ideal for applications requiring high isolation. The dielectric withstand
characteristics of each converter are measured in production to ensure barrier integrity.
●
●
●
●
●
●
●
●
●
●
The HB01U Series is ideal for applications where the
output is susceptible to high voltage transients, such as
motor drive and industrial process control applications.
The low barrier capacitance gives excellent input to
output dV/dt characteristics thus protecting the input
control circuitry from peak transients appearing on the
output.
HIGH ISOLATION
2500Vrms ISOLATION TEST VOLTAGE
BARRIER 100% PRODUCTION TESTED
LOW BARRIER CAPACITANCE - 10pF
LOW LEAKAGE CURRENT - 2µA MAX
24-PIN DIP AND SMD
INTERNAL FILTERING
NON-CONDUCTIVE CASE
LOW COST
LOW PROFILE - .375"
The HB01U Series uses a self-oscillating circuit design
technology to realize low cost and high performance. The
inherent current limiting capability of the high isolation
design reduces high current stresses during start-up thus
increasing the capacitive load capability while maintaining high reliability.
As with all of our DC/DC converters, surface mount
construction combined with extensive qualification testing assures low cost without sacrificing quality and reliability.
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537
Fax: 520.770.9369
HB01U 11/98 REV B
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
MODEL
RATED
OUTPUT
VOLTAGE
RATED
OUTPUT
CURRENT
INPUT CURRENT
MIN LOAD
RATED LOAD
EFFICIENCY
(VDC)
(VDC)
(mA)
(mA)
HB01U05S05
HB01U05S12
HB01U05S15
5
5
5
5
12
15
200
83
67
63
63
63
290
290
290
68
70
73
HB01U12S05
HB01U12S12
HB01U12S15
12
12
12
5
12
15
200
83
67
20
20
20
120
120
114
68
70
73
HB01U15S05
HB01U15S12
HB01U15S15
15
15
15
5
12
15
200
83
67
25
25
25
98
95
90
68
70
73
HB01U24S05
HB01U24S12
HB01U24S15
24
24
24
5
12
15
200
83
67
13
13
13
61
60
57
68
70
73
HB01U05D05
HB01U05D12
HB01U05D15
5
5
5
±5
±12
±15
±100
±42
±34
63
63
63
290
285
275
68
70
73
HB01U12D05
HB01U12D12
HB01U12D15
12
12
12
±5
±12
±15
±100
±42
±34
20
20
20
123
118
114
68
70
73
HB01U15D05
HB01U15D12
HB01U15D15
15
15
15
±5
±12
±15
±100
±42
±34
25
25
25
98
95
90
68
70
73
HB01U24D05
HB01U24D12
HB01U24D15
24
24
24
±5
±12
±15
±100
±42
±34
13
13
13
61
60
57
68
70
73
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
20
5
12
15
24
35
5.5
13.2
16.5
30
VDC
VDC
VDC
VDC
mAp-p
(mA)
(%)
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
INPUT
Voltage Range
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
Line Regulation
Load Regulation
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. F
Ground Benign
TEMPERATURE
Specification
Operation
Storage
Page 2
60 Hz, 10 Seconds
3535
2500
VDC
Vrms
10
10
1
VISO= 240VAC, 60Hz
1
±3
±0.02
50
25
±1.5
BW = DC to 10MHz
BW =10Hz to 2MHz
High Line to Low Line
See Performance Curves (Min Load =1mA)
Circuit Stress Method
TA = +25°C
-25
-40
-40
2
±5
GΩ
pF
µArms
W
%
%/°C
mVp-p
mVrms
%/% Vin
160
12
kHz
g
2,000,000
Hr
+70
+85
+110
°C
°C
°C
HB01U 11/98 REV B
MECHANICAL
Package/Pinout "Y" and "Z"
DIP PACKAGE
SMD PACKAGE
1.285±0.010"
(32.64±0.25)
1.285±0.010"
(32.64±0.25)
2423 22
0.525±0.010"
(13.34±0.25)
2423 22
1514 13
HB01UxxyzzY
1 2 3
0.525±0.010"
(13.34±0.25)
TOP VIEWS
HB01UxxyzzZ
1 2 3
10 11 12
0.375±0.005"
(9.52±0.13)
0°-15°
0.600"
(15.24)
0.015±0.005"
(0.38±0.13)
0.020±0.002"
(0.51±0.05)
0.100±0.010"
(2.54±0.25)
0.125+0.030"
-0.000"
(3.18+0.76)
(
-0.00)
0.695±0.015"
(17.65±0.38)
10 11 12
0.375±0.005"
(9.52±0.13)
SIDE VIEWS
0.015±0.005"
(0.38±0.13)
1514 13
END VIEWS
0.100±0.010"
(2.54±0.25)
0.014±0.002"
(0.36±0.05)
NU = Do Not Use.
0.020±0.002"
(0.51±0.05)
.015±.010"
(.38±.25)
PIN CONNECTIONS
NC = No Internal Connection.
PIN#
Duplicate pin functions are internally connected.
All dimensions are in inches (millimeters).
SINGLES
DUALS
1
2
3
+V OUT
-VOUT
NU
+V OUT
Common
-VOUT
10
11
12
-VIN
NC
+V IN
-VIN
NC
+V IN
13
14
15
+V IN
NC
-VIN
+V IN
NC
-VIN
21
22
23
24
NC
NU
-VOUT
+V OUT
NC
-VOUT
Common
+V OUT
GRID: 0.100 inches (2.54 millimeters)
Typically Marked with: specific model ordered, date code, job code and Logo.
MATERIAL: Units are encapsulated in a low thermal resistance molding
compound which has excellent chemical resistance, wide operating
temperature range, and good electrical properties under high humidity
environments. The encapsulant and outer shell of the unit have UL94V-0
ratings. Lead material is brass with a solder plated surface to allow ease of
solderability.
RECOMMENDED LAND PATTERN
RECOMMENDED REFLOW PROFILE
30 sec MAX
(>220°C)
0.100"
(2.54)
250
235 °C MAX
2423 22
220
1514 13
200
0.040"
(1.02)
1 2 3
10 11 12
1.150"
(29.21)
TEMPERATURE (°C)
0.080"
(2.03)
0.730"
(18.54)
190
150
100
90 sec MAX
(>190°C)
50
TIME (seconds)
HB01U 11/98 REV B
Page 3
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation...................................................0.5 Watt
Short Circuit Duration...............................................................5 Min
Lead Temperature (soldering, 10 seconds max)..................+300°C
HB01U xxyzz Y/Z /H
Device Family
HB Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
Screening Option
*
*Note: Refer to Reflow Profile for SMD Models.
TYPICAL PERFORMANCE CURVES
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
VOUT VS LOAD
(±5Vout Models)
6.0
5.7
5.8
Vout (Volts)
Vout (Volts)
VOUT VS LOAD
(5Vout Models)
5.9
5.5
5.3
5.6
5.4
5.1
5.2
4.9
5.0
1
20
150
100
80
Load (mA)
200
1
20
12.5
12.6
12.4
12.5
12.4
12.3
100
30
40
30
34
12.3
12.2
12.1
1
10
30
50
70
12.0
90
1
5
10
20
Load (mA)
Load (mA)
VOUT VS LOAD
(15Vout Models)
VOUT VS LOAD
(±15Vout Models)
15.4
15.4
15.3
15.3
Vout (Volts)
Vout (Volts)
12.2
80
VOUT VS LOAD
(±12Vout Models)
12.7
Vout (Volts)
Vout (Volts)
VOUT VS LOAD
(12Vout Models)
60
40
Load (mA)
15.2
15.1
15.2
15.1
15.0
15.0
14.9
14.9
1
10
20
40
60
67
1
Load (mA)
5
10
20
Load (mA)
EFFICIENCY VS LOAD
Efficiency (%)
80
70
60
50
40
30
20
40
60
80
100
Load (mA)
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility
for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any
of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems
or in aircraft control applications.
Page 4
HB01U 11/98 REV B
Similar pages