RF Signal Relays AXICOM HF3 Relay n n n n n n n Y-Design Frequency range DC to 3GHz Impedance 50Ω or 75Ω Small dimensions (14.6x7.2x10mm) 1 form C contact (1 changeover contact) Immersion cleanable Low power consumption (≤140mW) Typical applications Cable modems and linecards/ CATV, Tabs, measurement and test equipment ATE, satellite / audio / video tuners, wireless base stations and antennas, switching boards Contact Data Contact arrangement Max. switching voltage Rated current Limiting continuous current, 23°C Switching power Max. continuos RF-power, 23°C Contact material Minimum switching voltage Initial contact resistance Operate time Release time without diode in parallel with diode in parallel Bounce time Duration of set/reset pulse min. Mechanical endurance Coil Data Coil voltage range 1 form C, 1 CO 220VDC, 250VAC 2A 2A 60W, 62.5VA, 50W (2.5GHz) 50W (2.5GHz) Ag, Au covered 100µV <100mΩ at 10mA, 20mV typ. 3ms, max. 5ms typ. 2ms, max. 5ms typ. 4ms, max. 6ms typ. 1ms, max. 3ms 20ms 107 operations 3 to 24VDC Coil Data (continued) Coil versions, bistable Coil Rated Set Limiting code voltage voltage voltage VDC VDC VDC 50Ω version, bistable, 1 coil 71 3 2.25 9.20 72 4.5 3.38 13.85 73 5 3.75 15.30 74 6 4.50 18.50 75 9 6.75 27.70 76 12 9.00 37.00 77 24 18.00 74.00 50Ω version, bistable, 2 coils 91 3 2.25 6.50 92 4.5 3.38 9.80 93 5 3.75 10.90 94 6 4.50 13.00 95 9 6.75 19.60 96 12 9.00 26.10 97 24 18.00 52.30 Reset voltage VDC Coil Rated coil resistance power Ω±10% mW -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.00 128 289 357 514 1157 2057 8228 70 70 70 70 70 70 70 2.25 3.38 3.75 4.50 6.75 9.00 18.00 64 145 178 257 574 1028 4114 140 140 140 140 140 140 140 All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil versions, monostable Coil Rated Operate Limiting Release Coil Rated coil code voltage voltage voltage voltage resistance power VDC VDC VDC VDC Ω±10% mW 50Ω version, monostable, 1 coil 51 3 2.25 6.50 0.30 64 140 52 4.5 3.38 9.80 0.45 145 140 53 5 3.75 10.90 0.50 178 140 54 6 4.50 13.00 0.60 257 140 55 9 6.75 19.60 0.90 574 140 56 12 9.00 26.10 1.20 1028 140 57 24 18.00 52.30 2.40 4114 140 75Ω version, monostable, 1 coil 01 3 2.25 6.50 0.30 64 140 02 4.5 3.38 9.80 0.45 145 140 03 5 3.75 10.90 0.50 178 140 04 6 4.50 13.00 0.60 257 140 05 9 6.75 19.60 0.90 574 140 06 12 9.00 26.10 1.20 1028 140 07 24 18.00 52.30 2.40 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil Data (continued) Coil versions, bistable Coil Rated Set Limiting code voltage voltage voltage VDC VDC VDC 75Ω version, bistable, 1 coil 21 3 2.25 9.20 22 4.5 3.38 13.85 23 5 3.75 15.30 24 6 4.50 18.50 25 9 6.75 27.70 26 12 9.00 37.00 27 24 18.00 74.00 75Ω version, bistable, 2 coils 41 3 2.25 6.50 42 4.5 3.38 9.80 43 5 3.75 10.90 44 6 4.50 13.00 45 9 6.75 19.60 46 12 9.00 26.10 47 24 18.00 52.30 Reset voltage VDC Coil Rated coil resistance power Ω±10% mW -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.00 128 289 357 514 1157 2057 8228 70 70 70 70 70 70 70 2.25 3.38 3.75 4.50 6.75 9.00 18.00 64 145 178 257 574 1028 4114 140 140 140 140 140 140 140 All figures are given for coil without pre-energization, at ambient temperature +23°C. 06-2013, Rev. 0613 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 dition reset condition Contacts in reset position. Contact position might change during transportation and must be reset before use. RF Signal Relays HF3 Relay (Continued) Coil Operating Range 140 mW 70 mW RF Data Coil operating Range Isolation 3.5 at 100MHz/900MHz 80dB/72dB 70 mW at 3GHz 45dB 3 Insertion loss Umax. at 0 A at 100MHz/900MHz 0.03dB/0.12dB 2.5 at 3GHz 0.35dB Voltage standing wave ratio (VSWR) 2 at 100MHz/900MHz/3GHz 1.05/1.20/1.20 140 mW Coil Voltage [U/Unom] Coil Voltage [U/Unom] Umax. at 0 A s in reset position. Contact poight change during transportamust be reset before use. Unom. nominal coil voltage Urel. min. Unom = Umax. = 3.5 3 Coil Voltage [U/Unom] Uop. min. = Urel. min. = 2.5 2 1.5 1 80dB/72dB 40dB 0.03dB/0.12dB 0.40dB 1.05/1.20/1.40 1.5 Other Data 1 Unom. nominal coil voltage Uop. min. 70 mW AXICOM Ambient Temperature [°C] Nominal coil voltage Upper limit of the operative range70 ofmW the coil voltage (limiting voltage) Lower limit of the operativeUrange A max. at 0 of the coil voltage (reliable operate voltage) For latching relays Uset min. resp. Ureset min. Lower limit of the operative range of the coil voltage (reliable release voltage) Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 0.5 refer to the Product Compliance Support Center at Uop. min. www.te.com/customersupport/rohssupportcenter 0 Ambient temperature -55°C to +85°C -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75 85 95 105 115 125 135 Thermal resistance <165K/W Ambient Temperature [°C] Category of environmental protection IEC 61810 RT III - wash tight Degree of protection, IEC 60529 IP 67, immersion cleanable Vibration resistance (functional) 35g, 10 to 1000Hz Shock resistance (functional), half sinus 11ms 50g Shock resistance (destructive), half sinus 0.5ms 150g Terminal type SMT Weight max. 2.5g Resistance to soldering heat SMT IEC 60068-2-58 265°C/10s Moisture sensitive level, JEDEC J-Std-020D MSL3 Ultrasonic cleaning not recommended Packaging/unit reel/400 pcs., box/400 or 2000 pcs. Unom. nominal coil voltage All specifications subject to change. Consult Tyco Electronics for latest specifications. 0.5 Uop. min. 5 of 12 0 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75 85 95 105 115 125 135 Ambient Temperature [°C] Insulation Data age) eset min. 50Ω version Initial dielectric strength between open contacts between contact and coil Initial surge withstand voltage between open contacts between contact and coil 75Ω version 600Vrms 1000Vrms 1000V 1500V age) or latest specifications. 2 06-2013, Rev. 0613 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company 5 of 12 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. RF Signal Relays AXICOM HF3 Relay (Continued) Typical RF performance, 75Ω version 0 0 -20 -20 Isolation [dB] Isolation [dB] Typical RF performance, 50Ω version -40 NO -60 NC -80 -40 -80 NC -100 -100 -120 -120 0 500 1000 1500 2000 2500 3000 0 Frequency [Mhz] Insertion-loss [dB] 0.0 NC -0.2 NO -0.3 -0.4 0 500 1000 1500 1000 1500 2000 2500 2000 2500 2000 2500 Typical RF performance, 75Ω version (continued) 0.1 0.1 -0.1 500 Frequency [Mhz] Typical RF performance, 50Ω version (continued) Insertion-loss [dB] NO -60 2000 2500 0.0 NO -0.1 NC -0.2 -0.3 -0.4 3000 0 Frequency [Mhz] 500 1000 1500 1.25 1.20 1.20 1.15 1.15 VSWR VSWR Frequency [Mhz] 1.25 1.10 NC 1.05 NO 500 1000 1500 2000 NO 1.05 1.00 0 NC 1.10 2500 3000 Frequency[Mhz] 1.00 0 500 1000 1500 Frequency[Mhz] Terminal assignment TOP view on component side of PCB Monostable Bistable, 1 coil Bistable, 2 coils + set - - reset + 22 21 20 19 18 17 16 15 14 13 12 1 Contacts are shown in reset condition. Contact position might change during transportation and must be reset before use. 2 3 4 5 6 7 8 9 + reset - - set + 10 11 HF3-PIN- 06-2013, Rev. 0613 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3 RF Signal Relays AXICOM HF3 Relay (Continued) PCB layout TOP view on component side of PCB 50Ω version 75Ω version THIS DRAWING IS A CONTROLLED DOCUMENT. REVISIONS C D D1 D2 DATE Printing Printing REVIESED PER eco-11-005150 50Ω version REVISED PER ECO-11-017072 (ECR-13-009645) 21JUL2009 09JUL2010 09JUL2010 14JUN2013 7.2+0.1 -0.1 THIS DRAWING IS A CONTROLLED DOCUMENT. APVD UKo UKo RK UKo LOC HD HD HMR AK REVISIONS DIST HJ - P 2 3° LTR DESCRIPTION C D D1 D2 A 0.9+0.1 -0.1 14.6+0.1 -0.1 DWN DATE Printing Printing REVISED PER ECO-11-005150 REVISED PER ECO-11-017072 (ECR-13-009645) 75Ω version 09JUL2010 25MAR2011 14JUN2013 7.2+0.1 -0.1 14.6+0.1 -0.1 DWN UKo UKo UKo UKo 21JUL2009 APVD HD HD HMR AK A 10+0.5 0 DESCRIPTION 0.9+0.1 -0.1 LTR 2 P 2005 HJ Dimensions 3° DIST 10+0.5 0 LOC 4.9 4.9 RELEASED FOR PUBLICATION 14.6 5.08 3.81+0.1 -0.1 0.9 3.81+0.1 -0.1 2.54+0.1 -0.1 0.9 2.54+0.1 -0.1 0.8 0.8 0.7 0.95 0.4 5.08+0.1 -0.1 3.81 2.54 0.9 14.6 5.08+0.1 -0.1 +0.1 -0.1 3.81 +0.1 -0.1 2.54 0.5 0.8 0.9 +0.1 -0.1 0.5 +0.1 -0.1 22 21 20 19 18 17 16 15 14 13 12 C TOLERANCES UNLESS THERWISE SPECIFIED: DIN 7168-m ES (3/11) - 6.35+0.15 -0.15 7 8 9 10 11 0.9 1.27 Relay housing COPYRIGHT2005 BY TE Connectivity 7.2 5 6 5.08+0.1 -0.1 DIMENSIONS: mm CHK 16AUG2002 APVD 16AUG2002 HD 9121 HD 9121 PRODUCT SPEC - H2000-DOK02 A-A MATERIAL FINISH - 0 PLC 1 PLC 2 PLC 3 PLC 4 PLC ANGLES - - TE Connectivity 4 5 6 7 8 9 10 11 0.9 Relay housing 1.27 6.35+0.15 -0.15 0.6 2.54 A-A DWN 16AUG2002 CHK 16AUG2002 APVD 16AUG2002 HD 9121 HD 9121 PRODUCT SPEC - MATERIAL - CUSTOMER DRAWING TE Connectivity NAME SIZE - FINISH - HF3-Relay 75 Dimensions APPLICATION SPEC WEIGHT 3 0.5 5.08+0.1 -0.1 UKo 9193 - 2 0.9 XX = Relay type zz = nominal voltage YYWW = Date code NNNN = Lot number DIN 7168-m 16AUG2002 1 0.5 1.27+0.1 -0.1 6.35+0.15 -0.15 0.95 TOLERANCES UNLESS OTHERWISE SPECIFIED: DRAWING ALIAS: 0.5 1.27+0.1 -0.1 0.7 2.54 DWN RESTRICTED TO CAGE CODE DRAWING NO A4 00779 1462050-2 SCALE 3:1 SHEET 1 OF 1 REV D2 1469-35 (3/11) NAME SIZE A4 06-2013, Rev. 0613 CUSTOMER DRAWING www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company WEIGHT 5 0.9 HF3-Relay 50 Dimensions APPLICATION SPEC 41 4 0.9 5.08+0.1 -0.1 UKo 9193 mm 3 1.27 XX = Relay type zz = nominal voltage YYWW = Date code NNNN = Lot number DIMENSIONS: 2 0.8 C 6.35+0.15 -0.15 1 THIS DRAWING IS UNPUBLISHED. 0.95 0.5 +0.1 -0.1 1.27 5.08+0.1 -0.1 6 10 COPYRIGHT2005 BY TE Connectivity 0.8 +0.1 -0.1 0.5 0.4 22 21 20 19 18 17 16 15 14 13 12 0.8 0.7 0.95 10 5.08 +0.1 -0.1 ALL RIGHTS RESERVED. +0.1 -0.1 0.1 A 7.2 0.1 A 9.4+0.2 -0.2 5 6.7 9.4+0.2 -0.2 6 Coplanarity<=0.10mm 6.7 Coplanarity<=0.10mm CAGE CODE DRAWING NO 00779 RESTRICTED TO 1462051-2 Datasheets and product data is subject to the Datasheets and product specification SHEET REV OF according toSCALE IEC 61810-1 1 be used 1 3:1 and to D2terms of the disclaimer and all chapters of the ‘Definitions’ section, available at only together with the ‘Definitions’ section. http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. RF Signal Relays AXICOM HF3 Relay (Continued) Processing Packing Recommended soldering conditions Vapour phase soldering 20 to 40s 240°C full line: typical dotted line: process limits Temperature [°C] 180°C forced cooling 130°C external preheating 100°C Tape and reel for SMT Vapour phase soldering temperature/time profile (lead and housing peak temp.) Time [s] Recommended reflow soldering profile Reel dimensions Infrared soldering Temperature [°C] temperature/time profile (lead and housing peak temp.) Time [s] Resistance to soldering heat Infrared soldering Temperature [°C] temperature/time profile (lead and housing peak temp.) Time [s] 06-2013, Rev. 0613 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 5 RF Signal Relays AXICOM HF3 Relay (Continued) Product code structure Type Coil HF3 Typical product code HF3 53 Signal Relays HF3 Series 1 form C, 1 CO Coil code: please refer to coil versions table Performance type 5x 50Ω version, monostable 1coil 7x 50Ω version, bistable 1coil 9x 50Ω version, bistable 2coils Product code Arrangement 0x 2x 4x 75Ω version, monostable 1coil 75Ω version, bistable 1coil 75Ω version, bistable 2coils Version Coil Coil type Part number HF3 51 1 form C (1 CO) 50ohm 3VDC Monostable 1462051-1 HF3 524.5VDC 1-1462051-6 HF3 535VDC 1462051-2 HF3 546VDC 1-1462051-7 HF3 559VDC 1462051-3 HF3 5612VDC 1462051-4 HF3 5724VDC 1462051-5 HF3 71 1 form C (1 CO) 50ohm 3VDC Bistable 1 coil 1462051-6 HF3 724.5VDC 1-1462051-8 HF3 735VDC 1462051-7 HF3 7612VDC 1462051-9 HF3 91 1 form C (1 CO) 50ohm 3VDC Bistable 2 coils 1-1462051-1 HF3 924.5VDC 2-1462051-0 HF3 935VDC 1-1462051-2 HF3 959VDC 1-1462051-3 HF3 9612VDC 1-1462051-4 HF3 9724VDC 1-1462051-5 HF3 01 1 form C (1 CO) 75ohm 3VDC Monostable 1462050-1 HF3 024.5VDC 1-1462050-6 HF3 035VDC 1462050-2 HF3 0612VDC 1462050-4 HF3 0724VDC 1462050-5 HF3 21 1 form C (1 CO) 75ohm 3VDC Bistable 1 coil 1462050-6 HF3 235VDC 1462050-7 HF3 2612VDC 1462050-9 HF3 41 1 form C (1 CO) 75ohm 3VDC Bistable 2 coils 1-1462050-1 HF3 435VDC 1-1462050-2 HF3 4612VDC 1-1462050-4 HF3 4724VDC 1-1462050-5 This list represents the most common types and does not show all variants covered by this data sheet. Other types on request 6 06-2013, Rev. 0613 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.