FAIRCHILD HLMP

RIGHT ANGLE T-100 (3 mm)
Diffused
PACKAGE DIMENSIONS
FRONT VIEW
HER
HLMP-1700.MP4C
YELLOW HLMP-1719.MP4C
GREEN
HLMP-1790.MP4C
SIDE VIEW
0.157 (4.0)
0.100 (2.5)
Ø0.114 (2.9)
0.240 (6.1)
0.120 (3.0)
1
2
0.100 (2.5)
0.209 (5.3)
FEATURES
BOTTOM VIEW
• Standard 100 mil. lead spacing
• Solid state reliability
1 ANODE
2 CATHODE
• Diffused
• Low current (2 mA)
0.185 (4.7)
NOTE:
DESCRIPTION
Dimensions for all drawings are in inches (mm).
ABSOLUTE MAXIMUM RATINGS
These T-100 right angle lamps have a viewing
angle of 40°.
(TA = 25°C unless otherwise specified)
Parameter
Symbol
Rating
Unit
Operating Temperature
TOPR
-40 to +85
°C
Storage Temperature
TSTG
-40 to +100
°C
Lead Soldering Time
TSOL
260 for 3 sec
°C
IF
30
mA
IF
160
mA
Continuous Forward Current
Peak Forward Current
(f = 1.0 KHz, Duty Factor = 1/10)
Reverse Voltage
VR
5
V
Power Dissipation
PD
85
mW
ELECTRICAL / OPTICAL CHARACTERISTICS
Part Number
(TA =25°C)
HLMP-1700.MP4C
HLMP-1719.MP4C
HLMP-1790.MP4C
Minimum
1
1
1
Typical
2
2
2
Luminous Intensity (mcd)
Condition
IF = 2mA
Forward Voltage (V)
IF = 2mA
Maximum
2.7
2.7
2.7
Typical
1.9
1.9
1.9
Peak Wavelength (nm)
635
585
565
IF = 2mA
Spectral Line Half Width (nm)
45
20
30
IF = 2mA
Viewing Angle (°)
40
40
40
IF = 2mA
1 of 3
10/6/00
300092C
RIGHT ANGLE T-100 (3 mm)
Diffused
HER
HLMP-1700.MP4C
YELLOW HLMP-1719.MP4C
GREEN
HLMP-1790.MP4C
10.0
90
RELATIVE LUMNOUS INTENSITY
(NORMALIZED AT 2 mA)
IF - FORWARD CURRENT (mA)
80
70
YELLOW/HER
60
50
40
30
20
10
HER / YELLOW
8.0
6.0
4.0
2.0
GREEN
GREEN
0
0
1.0
2.0
3.0
4.0
0
5.0
2
4
6
8
10
IF - DC CURRENT PER LED (mA)
VF - FORWARD VOLTAGE (V)
Fig. 2 Relative Luminous Intensity vs.
DC Forward Current
Fig. 1 Forward Current vs. Forward Voltage
GREEN
YELLOW
HER
RELATIVE INTENSITY
1.0
-20˚
-10˚
0˚
10˚
20˚
-30˚
30˚
-40˚
40˚
-50˚
0.5
50˚
-60˚
60˚
-70˚
70˚
-80˚
0
500
550
600
650
700
-90˚
100
WAVELENGTH (nm)
80˚
80
60
40
20
0
20
40
60
80
90˚
100
REL. LUMINOUS INTENSITY (%)
Fig. 3 Relative Intensity vs. Peak Wavelength
Fig. 4 Radiation Diagram
IF - FORWARD CURRENT (mA)
50
40
30
20
10
0
0
20
40
60
85
100
TA - AMBIENT TEMPERATURE (˚C)
Fig. 5 Current Derating Curve
2 of 3
10/6/00
300092C
RIGHT ANGLE T-100 (3 mm)
Diffused
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO
ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME
ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN;
NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body,
or (b) support or sustain life, and (c) whose failure to
perform when properly used in accordance with
instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of the
user.
www.fairchildsemi.com
3 of 3
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
© 2000 Fairchild Semiconductor Corporation
10/6/00
300092C