DC/DC Converters 28 Volt Input hr300 Series 30 Watt NOT RECOMMENDED FOR NEW DESIGNS Features • –40° to +85°C operation models VDC Output • 18 to 36 VDC input (19 to 36 VDC input HR301-2805) single • 50 V for 50 ms transient protection 5 12 15 • Fully isolated • Fixed frequency switching dual ±12 ±15 • Remote sense on HR301-2805 model • Inhibit function • Indefinite short circuit protection • Up to 86% efficiency Size (max.): 2.720 x 1.350 x 0.505 inches (69.09 x 34.29 x 12.83 mm) See case J5 for dimensions. Weight: 60 grams max. Screening: Standard only. See screening table for more information. description HR300 Series™ DC/DC converters combine the small size and high reliability of hybrid-based components, the high efficiency of switching regulators, and the isolation, regulation, and low noise characteristics of linear regulators. Small Size and Reliability HR300 DC/DC converters use thick-film hybrid manufacturing techniques for smaller size, lighter weight and higher reliability than converters produced with other circuit techniques. With a footprint of less than 3.7 square inches and a 0.5 inch height, the HR300 converters reach power densities up to 22 watts per cubic inch. The HR300 parts use the same manufacturing procedures and quality controls that Interpoint applies to converters built for aerospace and military applications. The converters are hermetically sealed in metal packages that are guaranteed a maximum leak rate of less than 10-3 atm-cc/sec. High Performance HR300 converters use a constant frequency pulse-width modulated switching regulator design operating in the forward mode with a clock switching frequency of 240 to 300 kHz. Isolation is achieved through the use of a transformer in the forward power circuit and an optocoupler in the feedback control loop. The full load output power of 30 watts is available over the entire 18 to 36 VDC input range (19 to 36 HR3012805). On dual output models, up to 90% of full power is available from either output up to a combined total of 30 watts. The HR300’s high efficiency is maintained over the entire input voltage range and from approximately 25% of full load to full load (see typical efficiency curves). Crane Aerospace & Electronics Electronics Group (Interpoint Brand) PO Box 97005 • Redmond WA 98073-9705 425.882.3100 • [email protected] www.interpoint.com Short circuit protection is provided through foldback current limiting. When the output current reaches approximately 125% of the full rated load, the output voltage begins to reduce to protect the converter. The converter can sustain a true short circuit condition indefinitely. The HR300’s flanged case facilitates removal of heat and provides for mechanically secure mounting. If full power operation or indefinite short circuit protection is a system requirement, the HR300 converter should be mounted with an efficient heat sink in contact with the mounting flange. Internal filters in all HR300 converters provide low noise on both the input and outputs. On HR301 models, two-section L-C filters limit output ripple voltage and reflected input ripple current. On HR302 models, single-section L-C filters perform the same function. For maximum output regulation, the HR301-2805 is provided with external output voltage remote sense pins. Connecting the remote sense pins to the load provides a four-terminal voltage mode which eliminates the adverse effects of line resistance voltage drops. Remote sense pins may be left unconnected, but see cautions in this data sheet. For normal operation, remote sense pins should be connected to the respective output pins. Inhibit Function An inhibit is provided to allow a logic input to shut down the converter. An open circuit on the inhibit pin (pin 2 or 8) allows normal operation. A connection between the inhibit pin and the input common (pin 10) disables the internal oscillator, shutting down the output. The inhibit pin has an open circuit voltage of 11 to 16 V on single output models, 8 to 12 V on HR302-2812 and 10 to 14 V on HR302-2815. In the inhibit mode, approximately 1 mA must be sunk from the inhibit pin. An active low open collector is required to activate the inhibit function. Page 1 of 6 HR300 Rev D - 20100212 DC/DC Converters absolute maximum ratings hr300 series 30 Watt typical characteristics Input Voltage •18 to 36 VDC (19 to 36 VDC HR301-2805) Output Power •30 watts Lead Soldering Temperature (10 sec per lead) •300°C Storage Temperature Range (Case) •–55°C to +125°C Output Voltage Temperature Coefficient •100 ppm/°C typical Input to Output Capacitance •80 pF typical single output models •70 pF typical HR302-2812 •60 pF typical HR302-2815 Current Limit •125% of full load, typical Isolation •100 megohm minimum at 500 V Conversion Frequency •240 to 300 kHz Inhibit Pin Voltage (unit enabled) •11 to 16 V single output models •8 to 12 V HR302-2812 • 10 to 14 V HR302-2815 recommended operating conditions Input Voltage Range •18 to 36 VDC continuous 19 to 36 VDC HR301-2805 •50 V for 50 msec transient Case Operating Temperature (Tc) •–40°C to +85°C full power Derating Output Power/Current •Linearly from 100% at 85°C to 0% at 105°C inhibit Inhibit TTL Open Collector •Logic low (output disabled) Inhibit pin current 1 mA typical •Referenced to input common •Logic high (output enabled) Open collector Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified. single output models PARAMETER CONDITIONS hr301-2805 MIN hr301-2812 TYP MAX MIN TYP output voltage 4.95 5.0 5.05 11.88 12 output current — — 6.0 — — 2.5 MAX 14.85 15 15.15 — — — 30.0 — — 30 60 — 30 70 — 30 75 mV p-p min to max vin input ripple current W — 7 25 — 10 40 — 10 40 mV no load to full — 5 25 — 10 40 — 10 40 mV no load to full 19 28 36 18 28 36 18 28 36 transient 50 ms — — 50 — — 50 — — 50 15 20 — 20 35 — 20 35 1370 — 1400 — — 15 — — 22 — — 22 VDC no load — full load — inhibited — bw ≤ 2 MHz — 5 15 — 10 25 — 10 25 mA p-p 79 82 — 80 84 — 82 86 — % — 15 — — 30 — — 40 — ms — 500 — — 1200 — — 1500 — mV efficiency start-up 30.0 A bw ≤ 2 MHz input current — VDC tc = -40°C to +85°C input voltage tc = -40°C to +85°C 30.0 — 2.0 UNITS output ripple load regulation2 — 12.12 TYP output power line regulation1 — hr301-2815 MAX MIN delay2 overshoot — Notes 1.For HR301-2805, with the remote sense pins connected to the load and no resistance between the output pins and load. — — 1400 mA 2.A low output impedance power source is required on the input to realize this start-up time. If less than full surge current is available, start-up time will be longer CAUTION Permanent damage to the HR301-2805 will result if pin 6 is shorted to ground. Damage may also result if pin 4 or pin 5 is disconnected from the load during operation with the remote sense leads connected to the load. If remote sense pins are not connected to the load, the output voltage of theHR301-2805 will rise to approximately 6.2 VDC measured across pins 4 and 5. www.interpoint.com Page 2 of 6 HR300 Rev D - 20100212 DC/DC Converters Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified. triple output models PARAMETER output voltage output current1 output power1 hr302-2812 CONDITIONS + vout - vout MIN TYP hr302-2815 MAX MIN TYP MAX 11.88 12 12.12 14.85 15 15.15 11.88 12 12.12 14.85 15 15.15 — tc = -40°C to +85°C — — — 2.5 — 30.0 — — — UNITS VDC 2.0 A 30.0 W bw ≤ 2 MHz — 50 90 — 50 90 mV p-p line regulation vin = 18 to 36 — 10 30 — 10 40 mV load regulation no load to full — 20 60 — 20 60 mV + vout — 2.5 3.5 — 2.2 3.2 — 2.5 3.5 — 2.2 3.2 continuous 18 28 36 18 28 36 transient 50 ms — — 50 — — 50 output ripple cross regulation2 - vout input voltage tc = -40°C to +85°C input current input ripple current no load — full load — inhibited — bw ≤ 2 MHz — 80 — — 1500 efficiency start-up delay3 overshoot Notes 1.Up to 90% of full power is available from either output providing the total power does not exceed 30 watts. 2.The effect on the output voltage of either output (held at 3 watts) when the other output is varied from 3 to 27 watts. 35 45 % VDC 50 — 1350 — — 24 — — 24 15 60 — 15 60 84 — 81 85 — % 60 — — 60 — ms — — 1500 — mV — 60 — hr300 series 30 Watt mA 1400 mA p-p 3.A low output impedance power source is required on the input to realize this start-up time. If less than full surge current is available, start-up time will be longer pin out PinHR301-2805Single OutputDual Output 1 Positive Input Positive Input Positive Input 2 Inhibit Inhibit No connection 3 Sense Return No connection Positive Output 4 Output Common Output Common Output Common 5 Positive Output Positive Output Negative Output 6 Positive Sense No connection No connection 7 Case Ground Case Ground Case Ground 8 No connection No connection Inhibit 9 No connection No connection Input Common 10 Input Common Input Common Input Common www.interpoint.com Page 3 of 6 HR300 Rev D - 20100212 Squared corner and dot on top of cover indicate pin one. 1 2 3 4 5 BOTTOM VIEW HR300 See case J5 for dimensions. 10 9 8 7 Figure 1: Pin Out 6 DC/DC Converters hr300 series 30 Watt Typical Performance Curves: 25°C Tc 86 18 V 86 84 84 82 82 80 78 76 36 V 28 V 80 78 36 V 76 74 72 72 70 70 70 68 68 10 15 20 25 30 36 V 78 74 5 68 5 10 15 20 25 28 V 76 72 74 18 V 80 5 30 10 15 20 25 30 Output Power (Watts) Output Power (Watts) Output Power (Watts) HR301-2805 Efficiency Figure 2 HR301-2812 Efficiency Figure 3 HR302-2812 Efficiency Figure 4 18 18 88 18 V 86 84 Input Voltage (Volts) 28 V 82 80 78 76 74 36 V 72 17 Inupt Voltage (Volts) Efficiency (%) 28 V 82 Efficiency (%) 19 V Efficiency (%) 88 86 84 Efficiency (%) 88 88 HR301-2812 16 HR301-2815 15 17 HR302-2815 16 HR302-2812 15 70 68 5 10 15 20 25 30 Output Power (Watts) HR302-2815 Efficiency 14 5 10 15 20 25 14 30 Output Power (Watts) Figure 6 Figure 5 model numbering key Base Model HR30 2 - 28 Number of Outputs (1 = single, 2 = dual) Input Voltage Output Voltage www.interpoint.com Page 4 of 6 HR300 Rev D - 20100212 5 10 15 20 25 Output Power (Watts) 30 HR302-2812 and HR302-2815 Low Line Dropout Figure 7 HR301-2812 and HR301-2815 Low Line Dropout 12 DC/DC Converters hr300 series 30 Watt BOTTOM VIEW CASE J5 1 2 3 4 5 10 9 8 7 6 1.770 (44.96) 0.040 dia. (1.02) 1.370 (34.80) 1.173 (29.79 0.970 (24.64) 1.350 max. (34.29) 0.570 (14.48) Squared corner and dot on top of case indicate pin one. 0.170 (4.32) Solder Seal 0.162 dia. (4.11) 0.673 (17.09) Solder Tip-off 0.173 (4.39) 2.720 max (69.09) Flange thickness: 0.073 (1.85) max. Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Case J5, Rev E, 20100211 Please refer to the numerical dimensions for accuracy. All information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. Copyright © 1999-2010 Interpoint Corp. All rights reserved. Figure 8: Case J5 www.interpoint.com Page 5 of 6 HR300 Rev D - 20100212 2.150 (54.61) 0.000 0.210 (5.33) 0.25 (6.4) 0.000 0.505 max (12.83) 0.000 DC/DC Converters hr300 series 30 Watt HR INDUSTRIAL (STANDARD, NON-QML) PRODUCTS ENVIRONMENTAL SCREENING hr industrial standard non-Qml1 test perFormed Pre-cap Inspection Method 2017, 2032 yes Final Electrical Test MIL-PRF-38534, Group A Subgroups 1 and 4: +25°C case yes Hermeticity Test Gross Leak, Dip (1 x 10-3) yes Final visual inspection Method 2009 yes TestmethodsarereferencedtomIL-STD-883asdeterminedbymIL-PRF-38534. Notes: 1.Standard,non-QmLproducts,donotmeetalloftherequirementsofmIL-PRF-38534. HR300 Series DC/DC Converters, HR300 Rev D - 20100212. This revision supersedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. HR300 Series is a trademark of Interpoint. Copyright © 1999 - 2010 Interpoint Corporation. All rights reserved. www.interpoint.com Page 6 of 6