HRS2(H) Relay 1.COIL DATA 1-1.Nominal Voltage 1-2.Coil Resistance 1-3.Operate Voltage 1-4.Release Voltage 1-5.Nominal Power Consumption 3 VDC to 24 VDC Refer to Table 1 Refer to Table 1 Refer to Table 1 150 to 360 mW 2.CONTACT DATA 2-1.Contact Arrangement 2-2.Contact Material 2-3.Contact Rating 2-4.Max. Switching Voltage 2-5.Max. Switching Current 2-6.Max. Switching Power 2-7.Contact Resistance ( Initial ) Electrical 2-8.Life Expectancy Mechanical 2 Form C AuAg 1A 24 VDC / 120VAC 60 VDC / 120 VAC 2A 60 VA , 24W 100 mฆธ. at 6 VDC 1A 100,000 operations at nominal load 10,000,000 operations 3.GENERAL DATA 3-1.Insulation Resistance 3-2.Dielectric Strength 3-3.Surge Strength 3-4.Operate Time 3-5.Release Time 3-6.Temperature Range 3-7.Shock Resistance 3-8.Vibration Resistance 3-9.Weight 3-10.Safety Standard Min.100Mฆธ at 500 VDC 1,000VAC , 1min between open contact 1,500VAC , 1min between contact and coil 2,000 VAC ( 20 ฆฬs ) Max. 6ms Max. 4ms -30 to +60 กๆ 15G 10 - 55 Hz , Amplitude 1.5mm 5 gr. UL NO. E164730 CSA NO. LR109368 4.DIMENSIONS ( in mm ) 5.ORDERING CODE HS DC 3V กกกก | | NOMINAL VOLTAGE: | |_____กก | DC3V , DC5V , DC6V , DC9V , DC12V , DC24V | | | | _________ |____ | ENCLOSURE | กกS ---- WASHABLE | | | | |_____ ________ _________ COIL | กกNIL ---- STANDARD TYPE | H ------- HIGH SENSITIVE TYPE ( 150 mW , 200 mW ) |_____ ________ _________ _________ กกTYPE HRS2 6.COIL DATA CHART COIL NOMINAL VDC COIL RESISTANCE HRS2-S DC3V ฆธ +/- 10% OPERATE VOLTAGE VDC RELEASE VOLTAGE VDC 3 25 2.25 0.30 HRS2-S DC5V 5 70 3.75 0.50 HRS2-S DC6V 6 100 4.50 0.60 HRS2-S DC9V 9 220 6.75 0.90 HRS2-S DC12V 12 400 9.00 1.20 HRS2-S DC24V 24 1600 18.00 2.40 HRS2H-S DC3V 3 45 2.25 0.30 HRS2H-S DC5V 5 120 3.75 0.50 HRS2H-S DC6V 6 180 4.50 0.60 HRS2H-S DC9V 9 400 6.75 0.90 HRS2H-S DC12V 12 700 9.00 1.20 HRS2H-S DC24V 24 2800 18.00 2.40 ORDERING CODE Table 1 COIL NOMINAL mW 360 200 7.HRS2(H) CHARACTERISTIC DATA