LEM HTB100-TP Current transducers htb 50~400-p and htb 50~100-tp Datasheet

Current Transducers HTB 50 .. 400-P
and HTB 50 .. 100-TP
IPN = 50 .. 400 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
50
100
200
300
400
Type
HTB 50-P, HTB 50-TP1)
HTB 100-P, HTB 100-TP1)
HTB 200-P
HTB 300-P
HTB 400-P
±150
±300
±500
±600
±600
Supply voltage (±5 %) 2)
Current consumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Isolation resistance @ 500 VDC
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
VC
IC
Vd
RIS
VOUT
ROUT
RL
±12 .. ±15
V
<±15
mA
2.5
kV
>500
MΩ
±4
V
100
Ω
≥10
kΩ
ε
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
Thermal drift of VOE HTB 50-(T)P
L
VOE
VOH
VOT
TCε G
tr
f
HTB 100-(T)P..400-P
Thermal drift (% of reading)
Response time @ 90% of IP
Frequency bandwidth (0..-3 dB) 3)
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Wide power supply: ±12V to ±15V
• Primary bus bar option for 50A and
100A version for ease of connection
Advantages
• Small size and space saving
• Only one design for wide current
Accuracy - Dynamic performance data
X
Features
ratings range
<±1
<±1
<±30
% of IPN
% of IPN
mV
<±1
% of IPN
<±2.0
mV/K
<±1.0
mV/K
<±0.1
%/K
<3
µs
DC .. 50
kHz
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
General data
TA
TS
m
Ambient operating temperature
-20 .. +80
Ambient storage temperature
-25 .. +85
Mass (-TP version)
<30 (<36)
2 pins of Ø2mm diameter are available on transducer
for PCB soldering.
Notes : EN 50178 approval pending
1)
-TP version is equipped with a primary bus bar.
2)
Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
LEM Components
applications.
°C
°C
g
040720/9
www.lem.com
HTB 50 .. 400-P
Left view
Back view
Positive Current Flow
39
9 +/-1
1.5
19.5
34
d1
6
14 MAX.
3.5
4321
4-0.635x0.635
24.5
Secondary Pin Identification
5.5
3-P=2.5
10
Bottom view
1
2
3
4
7
11
3
6 +/-1
2-d2
Mounting Pins
3
19
+Vc
-Vc
Output
0V
HTB 50 .. 100-TP
39
14 MAX.
Left view
10
1.5
1.5
3.5
4 321
4-0.635x0.635
3.5
1.5
17
34
Back view
1.5
Positive Current Flow
3-P=2.5 10.5 3 3
3.25
6-1.5x1.5
3
11
14
2
6.5
3
Secondary Pin Identification
1
2
3
4
+Vc
-Vc
Output
0V
Bottom view
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.