LEM HTB200-SP5 Current transducer Datasheet

Current Transducers HTB 50..400-P/SP5
and HTB 50..100-TP/SP5
IPN = 50 .. 400 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
Primary current
measuring range
IPM (A)
50
100
200
300
400
VC
IC
Vd
RIS
VOUT
ROUT
RL
±
±
±
±
±
150
300
500
600
600
Type
Features
HTB 50-P/SP5, HTB 50-TP/SP51)
HTB 100-P/SP5, HTB 100-TP/SP51)
HTB 200-P/SP5
HTB 300-P/SP5
HTB 400-P/SP5
Supply voltage (± 5 %) 2)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
+ 12 .. 15
< 15
2.5
> 500
VOE ± 1.667
100
≥ 10
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
V
mA
kV
MΩ
V
Ω
kΩ
• Isolation voltage 2500V
• Low power consumption
• Primary bus bar option for 50A and
100A version for ease of connection
Special feature
• Single power supply from 12V to 15V
Accuracy - Dynamic performance data
X
ε
L
VOE
VOH
TCVOE
TCVOUT
tr
BW
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (0 .. ± IPN)
Electrical offset voltage @ TA = 25°C
Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN
Temperature coefficient of VOE HTB 50-(T)P/SP5
< ± 1 % of IPN
< ± 1 % of IPN
Vc/2 ± 30 mV
< ± 0.5 % of IPN
< ± 1.0 mV/K
HTB 100-(T)P..400-P/SP5 < ± 0.5
mV/K
Temperature coefficient of VOUT (% of reading)
< ± 0.05 %/K
Response time to 90% of IPN step
<3
µs
Frequency bandwidth (0 .. -3 dB)3)
DC .. 50
kHz
Ambient operating temperature
Ambient storage temperature
Mass (-TP version)
• Small size and space saving
• Only one design for wide current
ratings range
General data
TA
TS
m
Advantages
- 25 .. + 85 °C
- 25 .. + 85 °C
< 30 (< 36) g
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1)
-TP version is equipped with a primary bus bar.
2)
Operating at +12V ≤ Vc < +15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
Page 1/2
070111/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HTB 50..400-P/SP5 and HTB 50..100-TP/SP5 (in mm. 1 mm = 0.0394 inch)
HTB 50..400-P/SP5
Left view
Back view
Positive Current Flow
39
9 +/-1
1.5
19.5
34
d1
6
14 MAX.
3.5
32 1
34-0.635x0.635
24.5
Secondary Pin Identification
5.5
2-P=2.5
10
Bottom View
1 +Vc
2 0V
3 Output
7
11
3
6 +/-1
2-d2
Mounting Pins
3
19
HTB 50..100-TP/SP5
39
14 MAX.
Left view
10
1.5
1.5
3.5
321
34-0.635x0.635
3.5
1.5
17
34
Back view
1.5
Positive Current Flow
2-P=2.5 10.5 3 3
3.25
6-1.5x1.5
3
11
14
2
9
Secondary Pin Identification
1 +Vc
2 0V
3 Output
3
Bottom view
Page 2/2
070111/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Similar pages