XP Power HUL200-10 Ac-dc power supply Datasheet

AC-DC
175-300 Watts
xppower.com
HUL Series
•
Compact Size, Low Profile
•
Up to 5.85 W/in3 Power Density
•
Single & Multiple Outputs
•
Convection-cooled Ratings
•
Remote On/Off
•
Power Fail Detect
•
12 V Fan Supply
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-132 VAC, 180-264 VAC (auto-ranging)
• 47-63 Hz
• HUL175: 4.4 A max at 115 VAC,
2.2 A max at 230 VAC
HUL200: 5.0 A max at 115 VAC,
2.5 A max at 230 VAC
HUL300: 6.3 A max at 115 VAC,
3.15 A max at 230 VAC
Inrush Current
• 35 A at 115 VAC, 70 A max at 264 VAC
+25 °C cold start
Power Factor
• Passive PFC, meets EN6100-3-2, -3
Earth Leakage Current • <1.5 mA at 230 VAC / 50 Hz
Output
• See tables
• ±5% on output 1
• ±1% max for single/main output
±5% for auxiliary outputs
Minimum Load
• See tables & note 1 for 175 W model
Start Up Delay
• 1 s max
Start Up Rise Time
• 20 ms max
Hold Up Time
• >15 ms at 115 VAC
Total Regulation
• ±1% max for single output models,
±5% max for multiple output models
Over/Undershoot
• <5% max
Transient Response
• 5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (50 mV max for 3.3 V output)
Overvoltage Protection • 130% on output 1 only, recycle input to
reset
Overtemperature
• Shuts down when ambient temperature
Protection
exceeds +85 °C, auto recovery
Overload Protection
• 110-135% of total power, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
• ±0.1%/°C
Coefficient
Remote Sense
• HUL175 only. Compensates for 0.5 V drop
on 3.3 V output
Fan Output
Switching Frequency
Power Density
Power Fail Detect
MTBF
• 80% typical
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VAC Output to Ground
• 42 kHz typical
• HUL175: 4.51 W/In3, HUL200: 5.85 W/In3,
HUL300: 4.41 W/In3
• On = Logic high 100-500 ms after outputs
with regulation
Fail = Logic low at least 1 ms prior to loss
of output
• 100 kHrs per MIL-HDBK-217F
Environmental
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Remote On/Off
Efficiency
Isolation
• On = Logic High or Open
Off = Logic Low or Short
Not available on HUL175
• 12 V, 300 mA
Operating Temperature • 0 °C to +60 °C, derate linearly from 100%
at +40 °C to 50% at +60 °C
Cooling
• See notes
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 15 g (non-operation), 11 ms (half sine
wave), 3 times for each axis
Vibration
• 10-55 Hz (non-operation) 2 g, sweep time
3 mins, 60 mins/axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 and FCC, level B
(level A - 300 W) conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 4 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
70% 100 ms, 95% 5000 ms,
Perf Criteria A, B, B
• EN60950, UL60950, CSA22.2 No. 950
per cUL, CE Mark
Voltage
Nom
5.0 V
5.0 V
5.0 V
5.0 V
Output 1
Conv
Max
Voltage
Cooled 18.7 CFM Nom
10.0 A
15.0 A
3.3 V
10.0 A
15.0 A
3.3 V
10.0 A
15.0 A
3.3 V
10.0 A
15.0 A
3.3 V
Output 2
Conv
Max
Voltage
Cooled 18.7 CFM Nom
10.0 A
20.0 A
12.0 V
10.0 A
20.0 A
12.0 V
10.0 A
20.0 A
24.0 V
10.0 A
20.0 A
15.0 V
Output 3
Conv
Max
Cooled 18.7 CFM
2.2 A
3.0 A
2.2 A
3.0 A
1.5 A
2.0 A
2.2 A
3.0 A
Voltage
Nom
-5.0 V
-12.0 V
-12.0 V
-15.0 V
Output 4
Conv
Max
Cooled 18.7 CFM
0.7 A
1.0 A
0.7 A
1.0 A
0.7 A
1.0 A
0.7 A
1.0 A
Model
Number
HUL175-40-3†
HUL175-42-3†
HUL175-45-3†
HUL175-46-3†
Notes
1.
2.
3.
4.
5.
Minimum load is 2.0 A for V1, 0.0 A for V2 & V4, and 0.3 A for V3.
Total regulation for V1, V2 and V3 = ±5%; V4 = ±3%. Total regulation includes tolerance, line regulation and load regulation.
Total combined output power for the 3.3 V and 5.0 V not to exceed 126 W with 18.7 CFM or 70 W with convection cooling.
Maximum load continuous output power is 175 W with minimum 18.7 CFM forced air cooling or 100 W with convection cooling.
Outputs are fully isolated.
† Available from Farnell. See pages 204-206.
Mechanical Details
All dimensions are in inches (mm). Tolerance: 0.02 (0.5) max. Weight: 1.32 lbs (600 g) approx.
0.65
(16.5)
0.2
(5.1)
B
M3 x 0.5 STAND OFF 4 PLACES
A
2
P2 1
M4 x 0.7 NUT FASTENER 8 PLACES
24
3.80
(96.5)
P1
G
N
L
P3
2.50
(63.5)
1
A
B
Pin
1
2
P2 Connector
Function
Fan +
Fan -
Pin
1
2, 14
3, 15
4, 16
5, 17
6, 18
7, 19
8, 20
9, 21
10, 22
11,23
12
13
24
P3 Connector
Function
+3.3 V Sense+
Output 2
Output 2
Return
Return
Return
Output 1
Output 1
Output 3
Return
Output 4
Power Fail Detect
+3.3 V SenseReturn
6.40 (162.5)
4.58 (116.3)
0.80
(20.3)
1.50
(38.1)
0.24
(6.00)
2.90 (73.7)
A
A
1.25
(31.8)
5.20 (132.1)
6.00 (152.4)
6.80 (172.7)
Notes
1.
2.
3.
4.
Input connector P1 mates with Molex housing 09-91-0500 and Molex 2478/2578/8818 series crimp terminal.
Output connector P3 mates with Molex housing 39-01-2240 and Molex 44476 series crimp terminal.
Fan connector P2 mates with JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals. Fan output is 12 V/160 mA.
Covered versions are available,
add suffix: ‘-C’ to model number for cover only, dimensions: 3.80” x 6.80” x 1.66” (96.5 x 172.7 x 42.1 mm),
add suffix: ‘-FC’ to model number for fan cover, dimensions: 3.80” x 6.80” x 2.48” (96.5 x 172.7 x 63.0 mm).
5. Cable harnesses with 11.81” (300 mm) wire available, order part HUL175 LOOM KIT†. For mating connectors only, order part HUL175 CONN KIT†.
6. Covers are available separately. Order part HUL175 COVER† or HUL175 F/COVER† for Fan Cover.
7. Max penetration of screws 0.12” (3.0 mm).
AC-DC
HUL175
Models and Ratings
AC-DC
HUL200
Models and Ratings
Output 1
Current
Voltage
Nom
Min
Max
3.3 V
0.5 A
30.0 A
5.0 V
0.5 A
40.0 A
12.0 V
0.5 A
16.7 A
15.0 V
0.5 A
13.3 A
24.0 V
0.5 A
8.3 A
48.0 V
0.5 A
4.1 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+5.0 V
0.5 A
20.0 A
+12.0 V
0.5 A
3.0 A
+5.0 V
0.5 A
5.0 A
+5.0 V
0.5 A
3.0 A
+5.0 V
0.5 A
5.0 A
Output 2
Current
Voltage
Nom
Min
Max
+12.0
+15.0
+24.0
+12.0
+15.0
+12.0
+24.0
+15.0
+36.0
+36.0
+24.0
+12.0
V
V
V
V
V
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A
A
A
A
A
A
A
A
A
A
A
A
8.0
6.6
4.2
8.0
5.0
6.0
3.0
5.0
5.0
2.5
8.0
2.5
Output 3
Current
Voltage
nom
Min
Max
A
A
A
A
A
A
A
A
A
A
A
A
-5.0
-12.0
-5.0
+5.0
+12.0
+12.0
+24.0
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A
A
A
A
A
A
A
1.0
1.0
1.0
3.0
1.0
0.1
2.5
A
A
A
A
A
A
A
Output 4(3)
Current
Voltage
nom
Min
Max
F 12.0
F 15.0
F 12.0
F 12.0
F 15.0
-12.0
-12.0
-12.0
-12.0
V
V
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A
A
A
A
A
A
A
A
A
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.1
1.0
A
A
A
A
A
A
A
A
A
Model
Number(1)
HUL200-10-1†
HUL200-10†
HUL200-12†
HUL200-13†
HUL200-14†
HUL200-18†
HUL200-23†
HUL200-24†
HUL200-25†
HUL200-31†
HUL200-32†
HUL200-40†
HUL200-45†
HUL200-46†
HUL200-47
HUL200-47-2
HUL200-47-3
HUL200-47-1
Notes
1. Use part number UL200-XX for product without harmonic correction. e.g.: UL200-10.
2. Total output power for HUL200-10-1 is 73 W convection-cooled, 100 W with 18.7 CFM forced air cooling.
3. Output 4 is floating except for -47 models. It can be connected externally for positive or negative output.
4. Total output power for HUL200 single output models is 150 W convection-cooled, 200 W with 18.7 CFM forced air cooling.
5. Total output power for HUL200 multi output models is 100 W convection-cooled, 200 W with 18.7 CFM forced air cooling.
6. Tolerance 5% all outputs, except single output units - tolerance 2%.
† Available from Farnell. See pages 204-206.
Mechanical Details
All dimensions are in inches (mm). Tolerance: 0.02 (0.5) max. Weight: 1.76 lbs (800 g) approx.
1.25
(31.8)
Mounting holes:
A: M4 x 0.7, 8 places
B: 6-32, 8 places
2.5 (63.5)
L
N G
A
B
A
1
P1
B
B
A
6.40
(162.5)
5.77
(146.7)
6.80
(172.7)
A
FAN
B
P2
B
A
A
1.27
(32.3)
1.50
(38.1)
Pin 1
B
P3
3.80 (96.5)
±0.3 (7.6)
Pin 1
Pin
1
2
3
4
5
6
7
8
9
10
11
12
P2 Connector
Single Output
Multi Output
Output 1
Output 3
Output 1
Return
Output 1
Return
Output 1
Return
Output 1
Return
Output 1
Output 1
Return
Output 1
Return
Output 1
Return
Output 1
Return
Output 2
Return
Output 4
Return
Output 4 Return
Pin
1
2
3
4
5
6
P3 Connector
Single Output
Multi Output
Multi-outputs have 3
Fan +
separate 2 pin
Return
connectors for Fan,
Return
Power Good and Remote
Power Fail Detect
ON/OFF. These are
(7)
Remote On/Off
clearly marked on the
PCB.
Return -
Notes
1.
2.
3.
4.
5.
Input connector P1 mates with Molex housing 09-91-0500 and Molex 2478/2578/8818 series crimp terminal.
Output connector P2 mates with Molex housing 09-91-1200 and Molex 2478/2578/8818 series crimp terminal.
Fan connector mates with JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals.
Signals connector P3 mates with JST housing XHP-6 and JST SXH-002T-P0.6 crimp terminals or 3 off JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals.
Covered versions are available:
add suffix: ‘-C’ to model number for cover only - dimensions: 3.80” x 6.80” x 1.66” (96.5 x 172.7 x 42.1 mm),
add suffix: ‘-FC’ to model number for fan cover - dimensions: 3.80” x 6.80” x 2.48” (96.5 x 172.7 x 63.0 mm).
6. Covers are available separately. Order part HUL200 COVER† or HUL200 F/COVER† for Fan Cover.
7. Output is turned off by taking the Remote On/Off pin low (connect to Return).
8. Cable harnesses with 11.81” (300 mm) wire available, order part number HUL200 LOOM-S for single output models, HUL200 LOOM-D for dual output models,
HUL200 LOOM-T for triple output models or HUL200 LOOM-Q for quad output models.
9. For mating connectors only, order part HUL200 CON KT†.
10. Max penetration of screws 0.12” (3.0 mm)
Output 1
Current
Voltage
Nom
Min
Max
3.3 V
0.5 A
60.00 A
5.0 V
0.5 A
60.00 A
12.0 V
0.5 A
25.00 A
15.0 V
0.5 A
20.00 A
24.0 V
0.5 A
12.50 A
48.0 V
0.5 A
6.25 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
+5.0 V
0.5 A
30.00 A
Output 2
Current
Voltage
Nom
Min
Max
+12.0
+15.0
+24.0
+12.0
+15.0
+12.0
+24.0
+15.0
V
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A
A
A
A
A
A
A
A
12.5
10.0
6.3
10.5
8.0
10.0
4.3
7.4
Output 3
Current
Voltage
nom
Min
Max
A
A
A
A
A
A
A
A
-5.0 V
-12.0 V
-5.0 V
0.0 A
0.0 A
0.0 A
2.0 A
2.0 A
2.0 A
Output 4(2)
Current
Voltage
nom
Min
Max
F
F
F
F
F
12.0
15.0
12.0
12.0
15.0
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
A
A
A
A
A
2.0
2.0
2.0
2.0
2.0
A
A
A
A
A
Model
Number(1)
HUL300-10-1†
HUL300-10†
HUL300-12†
HUL300-13†
HUL300-14†
HUL300-18†
HUL300-23†
HUL300-24†
HUL300-25†
HUL300-31†
HUL300-32†
HUL300-40†
HUL300-45†
HUL300-46†
Notes
1. Use part number UL300-XX for product without harmonic correction. e.g. UL300-10.
2. Output 4 is floating. It can be connected externally for positive or negative output.
3. Total output power for HUL300-12,13,14,18 models is 200 W convection-cooled, 300 W with 30 CFM forced air cooling.
4. Total output power for all other HUL300 models is 150 W convection-cooled, 300 W with 30 CFM forced air cooling.
5. Tolerance 5% all outputs, except single output units - tolerance 2%.
† Available from Farnell. See pages 204-206.
Mechanical Details
All dimensions are in inches (mm). Tolerance: 0.02 (0.5) max. Weight: 2.20 lbs (1.0 kg) approx.
0.25 (6.35)
2.50 (63.5)
0.50
(12.7)
P1
1.09
(27.8)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
L N G
M4 x 0.7 NUT FASTENER
(12 PLACES)
8.00
(203.2)
7.50
(190.5)
7.00
(177.8)
5.81
(147.6)
P2
1
1.00
(25.4)
0.25
(6.4)
PIN 1
14 FAN
4.25 (108.0)
P3
Pin
1
2
3
4
5
6
P2 Connector
Single Output
Multi Output
Output 1
Output 3
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
Return
Output 1
Return
Return
Return
Return
Return
Return
Return
Return
Output 2
Return
Output 2
Return
Output 4
Return
Output 4 Return
P3 Connector
Single Output
Multi Output
Fan +
Return
Return
DC OK(7)
DC OK
Return
Power Fail Detect
Remote On/Off(6)
Remote On/Off(6)
Return
Return
Power Fail Detect
2.00 (50.8)
Notes
1.
2.
3.
4.
5.
Input connector P1 mates with Molex housing 09-91-0500 and Molex 2478/2578/8818 series crimp terminal.
Output connector P2 mates with Molex housing 09-91-1400 and Molex 2478/2578/8818 series crimp terminal.
Fan connector mates with JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals. Multiple outputs only.
Signals connector P3 mates with JST housing XHP-6 and JST SXH-002T-P0.6 crimp terminals.
Covered versions are available,
add suffix: ‘-C’ to model number for cover only, dimensions: 4.25” x 8.00” x 2.16” (108.0 x 203.2 x 54.8 mm)
add suffix: ‘-FC’ to model number for fan cover, dimensions: 4.25” x 8.00” x 3.00” (108.0 x 203.2 x 75.7 mm).
6. Output is turned off by taking the Remote On/Off pin low (connect to Return).
7. DC OK is a open collector output. Low = normal operation.
8. Cable harnesses with 11.81” (300 mm) wire available, order part number HUL300 LOOM-S for single output models, HUL300 LOOM-D for dual output models,
HUL300 LOOM-T for triple output models or HUL300 LOOM-Q for quad output models. For mating connectors only, order part HUL300 CON KT†.
9. Covers are available separately. Order part HUL300 COVER† or HUL300 F/COVER† for Fan Cover.
10. Max penetration of screws 0.12” (3.0 mm).
17-Apr-07
AC-DC
HUL300
Models and Ratings
Similar pages