SUTEX HV320LG Accurate, re-settable electronic circuit breaker Datasheet

HV320
Initial Release
Accurate, Re-Settable Electronic Circuit Breaker
(Negative Supply Rail)
Features
General Description
!
!
!
!
!
!
!
!
!
The Supertex HV320 re-settable electronic circuit breaker is
designed to provide fast, consistent and accurate current
limiting and load isolation during fault conditions. It may be
used in a variety of applications in such markets as telecom,
power, automotive, industrial, medical and security as well
as in systems where active control is implemented in the
negative supply lead. The current trip threshold is
programmed by a sense resistor and operates from voltages
ranging from 10V to 90V differentially.
Differential 10V to 90V operation (+VIN / -VEE)
UV and OV Lock Out
Power-On-Reset (POR) for debouncing
Sense resistor programs circuit breaker
Noise filter prevents false trip
Programmable circuit breaker trip time
Latched Operation
Low Power, <0.4mA
Small SO-8 package
The HV320 can easily replace popular positive temperature
coefficient (PTC) products such
as Raychem™
PolySwitches™ or re-settable polyfuses. HV320 overcomes
numerous performance shortcomings of existing PTC’s,
including trip point inaccuracy, increased device resistance
after initial reset, slow response time, susceptibility to
temperature variations and very high trip current to
operating current.
Applications
!
!
!
!
!
!
!
!
!
!
!
-48V Central Office Switching
-24V Cellular and Fixed Wireless Systems
-24V PBX Systems
Telecom Line Cards
-48V Powered Ethernet for VoIP
Distributed Power Systems
Power Supply Input/Output Fault Isolator
Electronic Circuit Breaker
Servers and SANS – replaceable modules
Automotive and Industrial Circuit Breakers
BUS Networks (CAN BUS, etc.)
During initial application of power, the gate of the external
pass device is clamped low to suppress contact bounce
glitches. Thereafter, the UV/OV supervisors and power-on
reset work together to suppress gate turn on until the input
power bounce ends. Once ON, HV320 continues to monitor
the input voltage and the load current level. If a load fault
occurs, the electronic circuit breaker will trip and the pass
element will be turned off. To restart, the UV or OV pins
must be toggled (for example by resetting the input voltage).
Typical Application Circuit
GND
Vin
R1
487k
UV
Load
HV320
R2
6.81k
OV
Vee
9.76 k
Gate
Sense
R3
R5
C1
1k
C2
10nF
-48V
R4
5 mOhm
IRFB4710
Supertex Inc. does not recommend the use of its products in life support applications and will not knowingly sell its products for use in such applications unless it receives an adequate
"products liability indemnification insurance agreement." Supertex does not assume responsibility for use of devices described and limits its liability to the replacement of devices determined
to be defective due to workmanship. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest
product specifications, refer to the Supertex website: http://www.supertex.com. For complete liability information on all Supertex products, refer to the most current data book or to the
Legal/Disclaimer page on the Supertex website.
HV320
Ordering Information
Absolute Maximum Ratings*
Package Option
Vee referenced to Vin pin
DEVICE
HV320
+0.3V to -100V
8 Pin SO
VUV and VOV referenced to Vee Voltage
HV320LG
Operating Ambient Temperature
-40°C to +85°C
Operating Junction Temperature
-40°C to +125°C
Storage Temperature Range
-65°C to +150°C
-0.3V to +12V
*Absolute Maximum Ratings are those values beyond which damage to the
device may occur. Functional operation under these conditions is not
implied. Continuous operation of the devide at the absolute rating level may
affect device reliability. All voltages are referenced to device ground.
Electrical Characteristics (-10 • V
EE
• -90V, -40°C • T • +85°C unless otherwise noted)
AC Characteristics
Symbol
Parameter
Min
Typ
Max
Units
Conditions
-10
V
450
µA
VEE = -48V
Supply (Referenced to Vin Pin)
Vee
Supply Voltage
Iee
Supply Current
OV and UV Control (Referenced to V
-90
400
EE
pin)
VUVH
UV High Threshold
1.26
V
Low to High Transition
VUVL
UV Low Threshold
1.16
V
High to Low Transition
VUVHY
UV Hysteresis
100
mV
IUV
UV Input Current
1.0
nA
Vuv = VEE + 1.9V @ 25° C
VOVH
OV High Threshold
1.26
V
Low to High Transition
VOVL
OV Low Threshold
1.16
V
High to Low Transition
VOVHY
OV Hysteresis
100
mV
IOV
OV Input Current
Circuit Breaker (V
UV
1.0
nA
VOV = VEE + 0.5V @ 25° C
= VEE + 1.9V, VOV = VEE + 0.5V, External MOSFET is IRFFR120N)
VSENSE-CB
Circuit Breaker Threshold Voltage
80
tCBTRIP
Circuit Breaker Delay Time
2.0
ISENSE-CB
IRFB4710 and IRFFR120 are registered trademarks of International Rectifier.
Raychem and PolySwitch are registered trademarks of Tyco International.
2
100
120
mV
5.0
µs
1.0
nA
Referenced to VEE pin @ 25°
C
May be extended by
external RC circuit
VSENSE-CB = 100mV @ 25° C
HV320
Gate Drive Output (Referenced to V
EE
pin, External MOSFET is IRFB4710*)
VGATE
Maximum Gate Drive Voltage
8.5
10
12
IGATEUP
Gate Drive Pull-Up Current
500
µA
IGATEDOWN
Gate Drive Pull-Down Current
40
mA
VGATELOW
Minimum Gate Drive Voltage
400
V
mV
VUV = Vee +1.9V,
VOV = Vee +0.5V
VUV = Vee +1.9V,
VOV = Vee +0.5V
VUV = Vee,
VOV = Vee +0.5V
VUV = Vee,
VOV = Vee +0.5V, Igate = 5mA
Dynamic Characteristics (See timing below, External MOSFET is IRFB4710)
tGATEHLOV
OV High to GATE Low
500
ns
tGATEHLUV
UV Low to GATE Low
500
ns
Vuvl
VUV
VOV
tGATEHLUV
Vgate
Pulsed VOV from VEE+0.5V to VEE
+1.9V
Pulsed VUV from VEE+1.9V to VEE
+0.5V
Vovh
tGATEHLOV
Vgate
Pinout for LG
Top View
NC
1
8
Vin
OV
2
7
NC
UV
3
6
Gate
Vee
4
5
Sense
Pin Description
OV --- This Over Voltage (OV) sense pin, when raised above its high threshold limit, will immediately cause the GATE pin to be
pulled low. The GATE pin will remain low until the voltage on this pin falls below the low threshold limit, initiating a new start-up
cycle.
UV – This Under Voltage (UV) sense pin, when below its low threshold limit, will immediately cause the GATE pin to be pulled
low. The GATE pin will remain low until the voltage on this pin rises above the high threshold limit, initiating a new start-up
cycle.
VEE – This pin is the negative terminal of the power supply input to the circuit.
VIN --- This pin is the positive terminal of the power supply input to the circuit.
GATE --- This is the Gate Driver Output for the external N-Channel MOSFET.
SENSE --- The current sense resistor connected from this pin to the VEE Pin programs the circuit breaker trip threshold.
3
HV320
Functional Block Diagram
UV
Regulator
& POR
-
Vin
+
Vbg
Logic
UVLO
buffer
-
OV
Gate
+
100mV
+
-
Vee
Sense
second, it could take more than 200A for 5µs before the
fusing element melts.
Functional Description
HV320 as a fuse and circuit breaker replacement:
Telecom, data networks, automotive, industrial controls
and some computer applications require the ability to
isolate the power source from a load fault without having
to physically replace a fuse or manually reset a
mechanical circuit breaker. Traditionally a fast acting fuse
or Positive Temperature Coefficient (PTC) device such as
Raychem’s PolySwitch or a manual / thermal circuit
breaker have been used to limit the fault current.
HV320 is an ideal alternative to thermal and manual circuit
breakers in DC input applications. It has wide variety of
uses in the automotive industry, such as PCB trace /
device protection and DC motors and solenoid actuator
current limit protection. These devices are typically used in
windows and seat adjustment operations as well as
automatic trunk opening mechanisms. Since these
devices are operated manually, they can remain energized
by the operator even after the mechanical lever has
reached its end of travel. In this case, back EMF that
normally opposes the supply voltage will drop to zero and
a large current surge can begin to flow. HV320 can
accurately be programmed to trip the current. In industrial
applications, HV320 can offer broad solutions in DC
solenoid-operated valves, DC motors and other
electromagnetic loads.
The problems with PTCs are numerous. First, they are
extremely temperature dependent. For example the
required trip current can vary as high as 150% of nominal
value at lower temperatures such as –40°C and as low as
50% of nominal value at higher temperatures such as
+85°C.
Second, the ratio of trip current to steady state current can
range from 7 to 70. This implies for an application where
steady state current is 4A, traces must be over designed
to withstand the trip current of 100A, a ratio of 25:1. Third,
PTC’s once tripped, require 20 seconds to minutes to
reset and even when they are reset, the resistance value
can permanently change as much as 240%. This implies
PTC’s are not suitable for repeated short circuit
applications. Lastly the surface mount PTCs typically have
large end cap terminations that absorb heat during the
reflow process and can result in insufficient solder and
cold solder joints. It is not uncommon for PCB surface
contaminations to be present, thus resulting in poor
solderability, hence loss of yield.
Fault current magnitude can be scaled to different current
ratings by proper selection of the sense resistor and the
external N-Channel MOSFET. For higher current
applications, IGBT devices may be considered. The
HV320 is intended to provide this circuit breaker function
on supply rails in the range of −10 to −90 Volts.
Description of Operation
During initial application of power, a unique proprietary
circuit holds off the external MOSFET, preventing an input
glitch while an internal regulator establishes an internal
operating voltage of approximately 10V. Until the proper
internal voltage is achieved, all circuits are held reset and
the gate to source voltage of the external MOSFET is
clamped low. Once the internal under voltage lock out
Typically, fuses are rated in Amp^2-seconds. For a SMT
1206 size fast-acting 2A, 63V fuse rated at 0.23 A - square
4
HV320
(UVLO) has been satisfied, the circuit checks the input
supply under voltage (UV) and over voltage (OV) sense
circuits to ensure that the input voltage is within
programmed limits. These limits are determined by the
selected values of resistors R1, R2 and R3 that form a
voltage divider. Once the input voltage is within the
programmed limits, the controller will force the GATE
terminal to nominal 10V and the circuit breaker supervisor
is enabled.
an over current condition is detected and is reset by
removal and reapplication of input power.
At any time during the start up cycle or thereafter, crossing
the UV and OV limits (including hysteresis) will cause an
immediate reset of all internal circuitry. When the input
supply voltage returns to a value within the programmed
UV and OV limits, a new start up sequence will be
initiated.
Safety recommendation: For safety critical applications
where UL, CSA or other safety agency approvals are
required, a fuse must be placed in series with HV320.
Although HV320 will protect a fuse from opening in many
instances, from the safety agency point of view, ICs
cannot displace a fuse.
When the voltage on the SENSE pin rises to 100mV,
indicating an over current condition, the circuit breaker will
trip in less than 5µs. This time may be extended by the
addition of external components (refer to Application
Circuit 3 on page 9). The gate voltage is latched off when
Test Set Up Circuit
GND
Vin
R1
487k
100uF
100V
UV
Load
HV320
R2
6.81k
OV
Vee
R3
Gate
Sense
C1
9.76 k
Output Short Circuit Switch
R5
R4
-48V
1k
C2
10nF
50 mOhm
IRFR120
Waveforms
Vgs
5V/div
Steady state operation
followed by a lead short
FET
Current
2V/div
Figure 1
FET
Current
1V/div
Figure 2
5
HV320
Design Information
Then
Setting Under Voltage and Over Voltage Shut Down
The UV and OV pins are connected to comparators with
typical 1.26V thresholds and 100mV of hysteresis. They
are used to detect under voltage and over voltage
conditions at the input to the circuit. Whenever the OV pin
rises above its high threshold (1.26V) or the UV pin falls
below its low threshold (1.16V), the GATE voltage is
immediately pulled low.
•VEEUV(on) • = 1.26 x (R1+R2+R3)/(R2+R3)
•VEEUV(on) •= 1.26 x (487k+6.81k+9.76k)/(6.81k+9.76k )
= 38.29V
and
Calculations can be based on either the desired input
voltage operating limits or the input voltage shutdown
limits. In the following equations the shutdown limits are
assumed.
•VEEOV(on) •= 1.16 x (R1+R2+R3)/R3
The under voltage and over voltage shut down thresholds
can be programmed by means of the three resistor divider
formed by R1, R2 and R3. Since the input currents on the
UV and OV pins are negligible the resistor values may be
calculated as follows:
Therefore, the circuit will start when the input supply
voltage is in the range of 38.29V to 59.85V. To overcome
longer bounce time during insertion, POR time must be
extended. An additional cap C1 (Page 1) must be added
from the UV pin to VEE. The value of this cap can be
calculated accordingly:
•VEEOV(on) •= 1.16 x (487k +6.81k +9.76k)/9.76k = 59.85V
UVOFF = VUVL = 1.16 = •VEEUV(off)•x (R2+R3)/(R1+R2+R3)
(
OVOFF = VOVL = 1.26 = •VEEOV(off)•x R3/(R1+R2+R3)
VC1 ( t ) = VIN x
Where •VEEUV(off)•and •VEEOV(off)• relative to VEE are Under and
Over Voltage Shut Down Threshold points.
(1–e
-tPOR
Req x C1
)
)
Where
VC1= 1.26
VIN = 1.60V
tPOR = desired POR time to overcome the bounce
Req = R1 ⎢⎢ (R2 + R3)
If we select a divider current of 100µA at a nominal
operating input voltage of 50 Volts, then
R1+R2+R3 = 50V/100uA = 500k Ohm
From the above C1 can be calculated:
From the second equation, for an OV shut down threshold
of 65V, the value of R3 may be calculated.
C1 =
OVOFF = 1.26 = (65xR3)/500k
tPOR
Req x 1.60
For example for tPOR = 10ms and
Values show on Page 1, the C1 calculates to be:
R3 = (1.26x 500k)/65 = 9.69k
The closest 1% value is 9.76k Ohm.
From the first equation, for a UV shut down threshold of
35V, the value of R2 can be calculated.
Req =
487 x (6.81 + 9.76)
487 + 6.81 + 9.76
C1 =
10 x 10-3
16000 x 1.60
UVOFF = 1.16 = 35 x (R2+R3) / 500k
= 16K
C1 ≅ .39µF
a .47µF can be used.
R2 = ((1.16 x 500k)/35) – 9.76k = 6.81k
The closest 1% value is 6.81k Ohm.
Then
Under Voltage/Over Voltage Operation
R1 = 500k – R2 – R3 = 483k Ohm.
GND
The closest 1% value is 487K Ohm.
UVOFF
UVON
Vin
From the calculated resistor values the OV and UV start
up threshold voltages can be calculated as follows:
OVON
OVOFF
UVON = VUVH = 1.26 = •VEEUV(on) •x (R2+R3)/(R1+R2+R3)
OVON = VOVL = 1.16 = •VEEOV(on) •x R3/(R1+R2+R3)
Pass
Transistor
Where •VEEUV(on) • and •VEEOV(on) • are Under and Over
Voltage Start Up Threshold points relative to Vee.
ON
OFF
6
HV320
Pd * (Rθjc + Rθcs + Rθsa) + TA ≤ Tj_derated
Start Up Overload Protection
If there is an output overload or short circuit during start
up, the circuit breaker will trip when the voltage at the
sense pin reaches 100mV. The gate is clamped low
indefinitely until input power is cycled, the UV pin is pulsed
low (<1.16V), or the OV pin is pulsed high (>1.26V). See
Figure 2 on Page 5.
Circuit Breaker
The circuit breaker will trip in less than 5µs when the
voltage on the SENSE pin reaches a nominal 100mV. A
resistor in series with the SENSE pin and a capacitor
connected between the SENSE and VEE pins may be
added to delay the rate of voltage rise on the SENSE pin,
thus permitting a current overshoot and delaying Circuit
Breaker activation. See Figure 1 on Page 5.
11.3 * (0.74 + 0.5 +Rθsa) + 55°C ≤ 150°C
Rθsa ≤ 7°C
Kelvin Connection to Sense Resistor
Physical layout of the printed circuit board is critical for
correct current sensing. Ideally trace routing between the
current sense resistor and the VEE and SENSE pins should
be direct and as short as possible with zero current in the
sense traces. The use of Kelvin Connection from SENSE
pin and VEE pin to the respective ends of the current sense
resistor is recommended.
Selection of External R_sense
As a design example, consider a 500W load of a –48V
rectifier: at a minimum regulation voltage of -42V, the
input current is 11.9A, assuming that the trip point is set
for 16A, the value of the sense resistor.
R_sense = 80mV / ITRIP = 0.08/16 = 0.005 Ohm
Where 80mV is the minimum circuit breaker trip level,
the maximum circuit breaker threshold is 120mV. This will
make the current trip level at 24A.
To
Vee
Pin
To
Sense
Pin
The power dissipation of the sense resistor is:
2
2
PRSENSE = (VSENSE-CB max) / R-sense = (0.12) / 0.005
= 2.88W
Two 0.01 Ohm, 2W, 2512 size SMT resistor may be used
in parallel. See Kelvin Connection to Sense Resistor.
To Negative
Terminal of
Power Source
Selection of External Pass Devices
The N-Channel may be selected based on maximum input
operating voltage, RDS, maximum operating load current
and peak short circuit current.
To Source
of MOSFET
Sense Resistors
Continuing with the example, the lowest Rds(on)
International Rectifier N-Channel MOSFET at 100V Vdss
is 14 m-Ohm. The IRFB4710* (TO-220) may be used for
this application.
FET Power Dissipation = (ICBmax^2) x Rds(on) x K = 24^2 x
0.014 x 1.4 = 11.3W
The K=1.4 factor is increased Rdson with respect to
temperature rise. Assuming Rθjc = 0.74°C/W and Rθcs =
0.5°C/W and the maximum operating temperature being
55°C, then the needed heat sink thermal resistance can
be calculated per:
7
HV320
Filtering Voltage Spikes on the Input Supply
In some systems over voltage spikes of very short duration may exist and can prematurely trip the circuit breaker. For these
systems a small capacitor may be added from the OV pin to the VEE pin to filter the voltage spikes.
GND
Vin
R1
487k
UV
HV320
R2
6.81k
LOAD
OV
Vee
R3
Gate
Sense
C1
9.76 k
R5
-48V
1k
C2
10nF
R4
5 mOhm
IRFB4710
Application Circuit 1
Increasing Under Voltage Hysteresis
If the internally fixed under voltage hysteresis is insufficient for a particular system application, then it may be increased by
using separate resistor dividers for OV and UV and providing a resistor feedback path from the gate pin to the UV pin.
GND
Vin
R1
475k
UV
R2
16.2k
HV320
R3
511k
R4
OV
R
Vee
Gate
Sense
10k
-48V
LOAD
R6
R5
5 mOhm
1k
C1
10nF
IRFB4710
Application Circuit 2
8
HV320
Extending Circuit Breaker Delay
Connecting a resistor in series with the SENSE pin and a capacitor between the SENSE and VEE pins as shown in the
following diagram may be used to extend the Circuit Breaker delay time beyond the 5µs internally set delay time.
GND
Vin
R1
487k
UV
HV320
R2
6.81k
R3
OV
Vee
Gate
Sense
R5
9.76 k
-48V
LOAD
C
R4
5 mOhm
R
1k
C2
10nF
IRFB4710
Application Circuit 3
Supertex inc.
1225 Bordeaux Drive, Sunnyvale, CA 94089
TEL: (408) 222-8888 · FAX: (408) 222-4895
www.supertex.com
©2003 Supertex Inc. All rights reserved. Unauthorized use ofr reproduction prohibited.
9