EIC HVR116 High voltage Datasheet

HVR112 - HVR120
HIGH VOLTAGE
RECTIFIER DIODES
PRV : 1200 - 2000 Volts
Io : 1.0 Ampere
DO - 41
FEATURES :
*
*
*
*
*
*
High current capability
High surge current capability
High reliability
Low reverse current
Low forward voltage drop
Pb / RoHS Free
1.00 (25.4)
MIN.
0.107 (2.7)
0.080 (2.0)
0.205 (5.2)
0.166 (4.2)
MECHANICAL DATA :
* Case : DO-41 Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight :
1.00 (25.4)
MIN.
0.034 (0.86)
0.028 (0.71)
0.34 gram
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
SYMBOL HVR112 HVR114 HVR116 HVR118 HVR120
UNIT
Maximum Repetitive Peak Reverse Voltage
VRRM
1200
1400
1600
1800
2000
V
Maximum RMS Voltage
VRMS
840
980
1120
1260
1400
V
VDC
1200
1400
1600
1800
2000
V
Maximum DC Blocking Voltage
IF(AV)
1.0
A
IFSM
30
A
Maximum Peak Forward Voltage at IF = 1.0 A
VF
2.2
V
Maximum DC Reverse Current
Ta = 25°C
IR
5.0
µA
at Rated DC Blocking Voltage
Ta = 100°C
IR(H)
100
µA
Cj
36
pF
RθJA
26
°C/W
Junction Temperature Range
TJ
- 40 to + 150
°C
Storage Temperature Range
TSTG
- 40 to + 150
°C
Maximum Average Forward Current
Ta = 75°C
Maximum Peak Forward Surge Current
8.3ms Single half sine wave Superimposed
on rated load (JEDEC Method)
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 2)
Notes :
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0VDC
(2) Thermal resistance from Junction to Ambient at 0.375" (9.5mm) Lead Lengths, P.C. Board Mounted.
Page 1 of 2
Rev. 02 : March 24, 2005
RATING AND CHARACTERISTIC CURVES ( HVR112 - HVR120 )
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
30
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
1.0
0.8
0.6
0.4
0.2
0
0
25
50
75
100
125
150
24
18
12
6
0
175
1
AMBIENT TEMPERATURE, ( °C)
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
6
10
20
40
60
100
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
TJ = 100 °C
REVERSE CURRENT,
MICROAMPERES
FORWARD CURRENT, AMPERES
4
10
10
1
0.1
Pulse Width = 300 µs
1% Duty Cycle
1.0
0.1
TJ = 25 °C
TJ = 25 °C
0.01
0.01
0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
FORWARD VOLTAGE, VOLTS
Page 2 of 2
2
NUMBER OF CYCLES AT 60Hz
3.6
4.0
0
20
40
60
80
100
120
140
PERCENT OF RATED REVERSE
VOLTAGE, (%)
Rev. 02 : March 24, 2005
Similar pages