ETC2 HWS150-24 Single output industrial power supply Datasheet

INNOVATION
SOLUTIONS
SUPPORT
RELIABILITY
• Lifetime Warranty
• UL508 approved
• SEMI F47 Compliant (high line AC)
• Universal Input (85 - 265VAC)
• High Efficiency
• RoHS Compliant Design
Key Market Segments & Applications
Factory Automation
HWS Series
Single Output Industrial
Power Supplies
Test & Measurement
Automated Service
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
HWS Features and Benefits
Features
Benefits
• Lifetime Warranty
• High Efficiency
• Wide Range AC Input
• Lower Cost of Ownership
• Easier System Cooling
• Supports Global Use
Specifications
MODELS
ITEMS
Input Voltage range
Input Current (Typ) (1)
Inrush Current 100/200VAC
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Indicator
Operating Temp. (no cover)
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Line Dip
Conducted & Radiated
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
Notes:
HWS15
A
A
V
ms
mA
EMI
g
mm
HWS30
HWS50
HWS100
HWS150
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
0.4 / 0.2
0.8 / 0.4
0.7 / 0.35
1.3 / 0.65
1.9 / 0.95
14 / 28
Meets EN61000-3-2
<0.02%/oC
>104%
Yes (See page 2)
20
<0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC)
No
Yes
Green LED = ON
-10C to +70C, derate linearly to 20% load from 50C to 70C
-30 to +85C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1m/s2
-UL60950-1, CSA60950-1, EN60950-1, EN50178, Built to meet UL508 CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 4), -5(Level 3,4), -6(Level 3), -8(Level4, -11
180
220
280
450
500
26.5x82x80
26.5x82x95
26.5x82x120
28x82x160
37x82x160
Lifetime Warranty (See Lambda’s terms & conditions)
(1) 100/200VAC
See website for HWS/ME medical EN/UL60601-1 approved models
and HWS/HD heavy duty / harsh environment models with -40 degree C startup
HWS SERIES
1
Model Selector
Model
HWS15-3/A
HWS30-3/A
HWS50-3/A
HWS100-3/A
HWS150-3/A
HWS15-5/A
HWS30-5/A
HWS50-5/A
HWS100-5/A
HWS150-5/A
HWS15-12/A
HWS30-12/A
HWS50-12/A
HWS100-12/A
HWS150-12/A
HWS15-15/A
HWS30-15/A
HWS50-15/A
HWS100-15/A
HWS150-15/A
1.2m/s Forced Air
HWS15-24/A
HWS30-24/A
HWS50-24/A
HWS100-24/A
HWS150-24/A
HWS15-48/A
HWS30-48/A
HWS50-48/A
HWS100-48/A
HWS150-48/A
Voltage
Adjust
Range
Max
Curr.
A
Load
Reg
mV
3.3V
3.3V
3.3V
3.3V
3.3V
5V
5V
5V
5V
5V
12V
12V
12V
12V
12V
15V
15V
15V
15V
15V
24V
24V
24V
24V
24V
48V
48V
48V
48V
48V
2.97 - 3.96
2.97 - 3.96
2.97 - 3.96
2.97 - 3.96
2.97 - 3.96
4.0 - 6.0
4.0 - 6.0
4.0 - 6.0
4.0 - 6.0
4.0 - 6.0
9.6 - 14.4
9.6 - 14.4
9.6 - 14.4
9.6 - 14.4
9.6 - 14.4
12.0 - 18.0
12.0 - 18.0
12.0 - 18.0
12.0 - 18.0
12.0 - 18.0
50°C
19.2 - 28.8
19.2 - 28.8
19.2 - 28.8
19.2 - 28.8
19.2 - 28.8
38.4 - 52.8
38.4 - 52.8
38.4 - 52.8
38.4 - 52.8
38.4 - 52.8
3
6
10
20
30
3
6
10
20
30
1.3
2.5
4.3
8.5
13
1
2
3.5
7
10
55°C
0.65
1.3
2.2
4.5
6.5
0.33
0.65
1.1
2.1
3.3
40
40
40
40
40
40
40
40
40
40
96
96
96
96
96
120
120
120
120
120
192
192
192
192
192
384
384
384
384
384
Line
Reg
mV
20
20
20
20
20
20
20
20
20
20
48
48
48
48
48
60
60
60
60
60
60°C
96
96
96
96
96
192
192
192
192
192
Ripple
Noise
mV
Over
voltage
V
120
120
120
120
120
120
120
120
120
120
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
200
200
4.13-4.95
4.13-4.95
4.13-4.95
4.13-4.95
4.13-4.95
6.25-7.25
6.25-7.25
6.25-7.25
6.25-7.25
6.25-7.25
15-17.4
15-17.4
15-17.4
15-17.4
15-17.4
18.8-21.8
18.8-21.8
18.8-21.8
18.8-21.8
18.8-21.8
65°C
30-34.8
30-34.8
30-34.8
30-34.8
30-34.8
55.2-64.8
55.2-64.8
55.2-64.8
55.2-64.8
55.2-64.8
Eff.
typ %
100/200 VAC
68/71
70/73
76/78
78/81
78/81
77/79
77/80
82/83
83/86
83/86
80/81
81/83
81/83
83/86
83/86
80/81
81/83
81/83
83/86
83/86
70°C
82/83
83/86
82/84
84/87
85/88
80/80
82/83
83/85
84/87
85/88
Options
Suffix
Description
Blank
/A
/R
Screw terminals, no cover
Screw terminals, cover
Remote on/off (50-150W only)
Example: HWS50-24/RA
Full size drawings and more
information available at
www.lambda-europe.com/hws
HWS15 Outline Drawing
2
HWS SERIES
HWS30 Outline Drawing
HWS50 Outline Drawing
HWS100 Outline Drawing
HWS150 Outline Drawing
Note: All fixing holes M3 tapped max. depth 6mm
HWS SERIES
3
LAMBDA EUROPE
AUSTRIA
LAMBDA ELECTRONICS GmbH
Aredstraße 22
A-2544 Leobersdorf
Telephone:
Facsimile:
+43 (0) 2256 655 84
+43 (0) 2256 645 12
www.lambda-austria.com
FRANCE
LAMBDA SAS
ZAC des Delaches, BP1077 - Gometz le Chatel
91940 Les Ulis
Telephone:
Facsimile:
Web:
+33 (0) 1 60 12 71 65
+33 (0) 1 60 12 71 66
www.lambda-f.com
GERMANY
LAMBDA GmbH
Karl-Bold-Straße 40
D-77855 Achern
Telephone:
Facsimile:
Web:
+49 (0) 78 41 666 0
+49 (0) 78 41 5000
www.lambda-germany.com
ISRAEL
NEMIC LAMBDA LTD
Kibbutz Givat
Hashlosha 48800
Telephone:
Facsimile:
Web:
+972 (0) 3 902 4333
+972 (0) 3 902 4777
www.nemic.co.il
ITALY
LAMBDA s.r.l.
Via dei Lavoratori 128/130,
20092, Cinisello Balsamo (Mi)
Telephone:
Facsimile:
Web:
+39 (0) 02 61 29 38 63
+39 (0) 02 61 29 09 00
www.lambda-italy.com
SWEDEN
LAMBDA SCANDINAVIA
PO Box 546, Rallarvägen 41
SE-184 25. Akersberga
Telephone:
Facsimile:
Web:
+46 (0) 8 598 94 090
+46 (0) 8 540 66 096
www.lambda-scandinavia.com
UK
LAMBDA UK
Kingsley Avenue
Ilfracombe Devon EX34 8ES
Telephone:
Facsimile:
Web:
+44 (0) 1271 856666
+44 (0) 1271 864894
www.lambda-gb.com
LAMBDA NORTH AMERICA
visit www.lambdapower.com for a list of Lambda offices and distributors
LAMBDA ASIA
visit www.densei-lambda.com for a list of Lambda offices and distributors
LOCAL DISTRIBUTION
4
HWS Series (15-150W) Iss4 Jan08
H
RIIEESS
DW
LPS SSEER
Similar pages