LEM HX15-P Current transducer Datasheet

Current Transducer HX 03..50-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 3 .. 50 A
All data are given with RL = 10 kW
Electrical data
Primary nominal
current rms
IPN (A)
Primary current
measuring range
IPM (A)
3
5
10
15
20
25
50
±9
± 15
± 30
± 45
± 60
± 75
± 150
VOUT
ROUT
RL
VC
VC
Features
Primary conductor
Type
diameter x turns
(mm)
●● Galvanic isolation between
primary and secondary circuit
●● Hall effect measuring principle
●● Isolation voltage 3000V
●● Low power consumption
●● Extended measuring range (3 x
IPN)
●● Power supply from ±12V to ±15V
●● Isolated plastic case recognized
according to UL 94-V0.
HX 03-P
HX 05-P
HX 10-P
HX 15-P
HX 20-P
HX 25-P
HX 50-P
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
Output voltage (Anarog) @ ± IPN, RL = 10 kW, TA = 25 °C
Output internal resistance
Load resistance
Supply voltage (± 5 %) 1)
Current consumption ±4
< 50
≥ 10
± 15
< ± 15
V
W
kW
V
mA
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C (xcluding offset)
< ± 1 % of IPN
Linearity
error
(0
..
±
I
)
<
± 1 % of IPN
L
PN
VOE
Electorical offset voltage @ IP = 0, TA = 25°C
< ± 40
mV
VOH
Hysteresis offset voltage @ IP = 0 after an excursion of 1 x IPN
< ± 15
mV
TCVOE Temperature coefficient of VOE
< ± 1.5 mV/K
TCVOUT Temerature coefficient of VOUT (% of reading)
± 0.1
%/K
tr
Response time to 90% of IPN step ≤3
µs
BW
Frequency bandwidth (- 3 dB) 2)
50
kHz
ε
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
...
Standards Note:
1)
2)
- 25 .. + 85
°C
- 25 .. + 85
°C
8
g
EN 50178: 1997
Also operate at ±12V power supples, measuring range reduced to ± 2.5 x IPN.
Small signal only to avoid excssive heating of the magnetic cores.
Advantages
●● Low insertion losses
●● Easy to mount with automatic
handling system
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference
Applications
●●
●●
●●
●●
AC variable speed drives
DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Electrical appliances
Application domain
●● Industrial
Page 1/3
110523/14 .
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Current Transducer HX 03..50-P
Isolation characteristics
Vd
Ve
Vw
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage 1.2/50 µs
> 3
≥ 1
≥ 6
kV
kV
kV
dCp
dCI
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (group I)
≥ 5.5
≥ 5.5
≥ 600
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
600 V
600 V
Reinforced insulation
300 V
150 V
dCp, dCI,Vw
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
110523/14 .
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HX 03..50-P.(in mm. 1 mm = 0.0394 inch)
HX03...25-P
03..25-P
HX
50-P
HXHX
50-P
19 Max.
19 Max.
Terminal Pin Identification
20 Max.
20 Max.
10.85
3
3.5
0.5
0.5
3.5
3.5
3
1 ..... -15 V
2 ..... 0 V
3 ..... +15 V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
3
8.8
5.4
Primary conductor diameter
d
5
5
3 +V
2 0
1 -V or 0
1.3
5
3-P=2.54
1 -V or 0
6
2 0
6
4 OUT
15.4 Max.
6
3 +V
15.4 Max.
3-P=2.54
4 OUT
HX
03-P
05-P
10-P
15-P
d
0.6
0.8
1.1
1.4
HX
20-P
25-P
50-P
d
1.6
1.6
1.2 x 6.3
1.2
3
3
10.85
Top view
8.8
5.4
Secondary pins dimension
0.5 x 0.25
HX 05-P
CN2
410123
41123
Lot No.
Mechanical characteristics
●● General tolerance
± 0.5 mm
Page 3/3