Hynix HY5DU56822FLTP-LI 256mb ddr sdram Datasheet

256Mb DDR SDRAM
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
This document is a general product description and is subject to change without notice. Hynix Semiconductor does not assume any
responsibility for use of circuits described. No patent licenses are implied.
Rev. 1.0 /Nov. 2007
1
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
Revision History
Revision No.
1.0
History
First Version Release
Rev. 1.0 /Nov. 2007
Draft Date
Remark
Nov. 2007
2
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
DESCRIPTION
The HY5DU56822F(L)TP-xxI and HY5DU561622F(L)TP-xxI are a 268,435,456-bit CMOS Double Data Rate(DDR) Synchronous DRAM, ideally suited for the main memory applications which requires large memory density and high bandwidth.
This Hynix 256Mb DDR SDRAMs offer fully synchronous operations referenced to both rising and falling edges of the
clock. While all addresses and control inputs are latched on the rising edges of the CK (falling edges of the /CK), Data,
Data strobes and Write data masks inputs are sampled on both rising and falling edges of it. The data paths are internally pipelined and 2-bit prefetched to achieve very high bandwidth. All input and output voltage levels are compatible
with SSTL_2.
FEATURES
•
VDD, VDDQ = 2.5V +/- 0.2V for DDR200, 266, 333
VDD, VDDQ = 2.6V +0.1V / -0.2V for DDR400, 500
•
All inputs and outputs are compatible with SSTL_2
interface
•
All addresses and control inputs except data, data
strobes and data masks latched on the rising edges
of the clock
•
Programmable CAS latency 2/2.5 (DDR200, 266,
333) and 3 (DDR400, 500) supported
•
Programmable burst length 2/4/8 with both sequential and interleave mode
•
Fully differential clock inputs (CK, /CK) operation
•
Double data rate interface
•
Source synchronous - data transaction aligned to
bidirectional data strobe (DQS)
•
Internal four bank operations with single pulsed
/RAS
•
x16 device has two bytewide data strobes (UDQS,
LDQS) per each x8 I/O
•
Auto refresh and self refresh supported
•
Data outputs on DQS edges when read (edged DQ)
Data inputs on DQS centers when write (centered
DQ)
•
tRAS lock out function supported
•
8192 refresh cycles/64ms
•
JEDEC standard 400mil 66pin TSOP-II with 0.65mm
pin pitch
•
Lead free (*ROHS Compliant)
•
On chip DLL align DQ and DQS transition with CK
transition
•
DM mask write data-in at the both rising and falling
edges of the data strobe
OPERATING FREQUENCY
ORDERING INFORMATION
Part No.
Configuration
Package
HY5DU56822F(L)TP-xx*I
32Mx8
400mil
HY5DU561622F(L)TP-xx*I
16Mx16
66pin
TSOP-II**
Grade
Clock Rate
Remark
(CL-tRCD-tRP)
- D5
250MHz@CL3
DDR500 (3-3-3)
- D43
200MHz@CL3
DDR400B (3-3-3)
-J
133MHz@CL2
[email protected]
DDR333 (2.5-3-3)
* xx means speed grade
** Lead-free product
-K
133MHz@CL2
[email protected]
DDR266A (2-3-3)
-H
100MHz@CL2
[email protected]
*ROHS (Restriction Of Hazardous Substances)
-L
Rev. 1.0 /Nov. 2007
100MHz@CL2
DDR266B (2.5-3-3)
DDR200 (2-2-2)
3
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
PIN CONFIGURATION
x8
VDD
DQ0
VDDQ
NC
DQ1
VSSQ
NC
DQ2
VDDQ
NC
DQ3
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
x16
VDD
DQ0
VDDQ
DQ1
DQ2
VSSQ
DQ3
DQ4
VDDQ
DQ5
DQ6
VSSQ
DQ7
NC
VDDQ
LDQS
NC
VDD
NC
LDM
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
400mil X 875mil
66pin TSOP -II
0.65mm pin pitch
(Lead free)
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
x16
x8
VSS
DQ15
VSSQ
DQ14
DQ13
VDDQ
DQ12
DQ11
VSSQ
DQ10
DQ9
VDDQ
DQ8
NC
VSSQ
UDQS
NC
VREF
VSS
UDM
/CK
CK
CKE
NC
A12
A11
A9
A8
A7
A6
A5
A4
VSS
VSS
DQ7
VSSQ
NC
DQ6
VDDQ
NC
DQ5
VSSQ
NC
DQ4
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CK
CK
CKE
NC
A12
A11
A9
A8
A7
A6
A5
A4
VSS
ROW AND COLUMN ADDRESS TABLE
Rev. 1.0 /Nov. 2007
ITEMS
32Mx8
16Mx16
Organization
8M x 8 x 4banks
4M x 16 x 4banks
Row Address
A0 - A12
A0 - A12
Column Address
A0-A9
A0-A8
Bank Address
BA0, BA1
BA0, BA1
Auto Precharge Flag
A10
A10
Refresh
8K
8K
4
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
PIN DESCRIPTION
PIN
TYPE
CK, /CK
Input
Clock: CK and /CK are differential clock inputs. All address and control input signals are
sampled on the crossing of the positive edge of CK and negative edge of /CK. Output
(read) data is referenced to the crossings of CK and /CK (both directions of crossing).
CKE
Input
Clock Enable: CKE HIGH activates, and CKE LOW deactivates internal clock signals, and
device input buffers and output drivers. Taking CKE LOW provides PRECHARGE POWER
DOWN and SELF REFRESH operation (all banks idle), or ACTIVE POWER DOWN (row
ACTIVE in any bank). CKE is synchronous for POWER DOWN entry and exit, and for SELF
REFRESH entry. CKE is asynchronous for SELF REFRESH exit, and for output disable. CKE
must be maintained high throughout READ and WRITE accesses. Input buffers, excluding
CK, /CK and CKE are disabled during POWER DOWN. Input buffers, excluding CKE are disabled during SELF REFRESH. CKE is an SSTL_2 input, but will detect an LVCMOS LOW level
after VDD is applied.
/CS
Input
Chip Select: Enables or disables all inputs except CK, /CK, CKE, DQS and DM. All commands are masked when CS is registered high. CS provides for external bank selection on
systems with multiple banks. CS is considered part of the command code.
BA0, BA1
Input
Bank Address Inputs: BA0 and BA1 define to which bank an ACTIVE, Read, Write or PRECHARGE command is being applied.
A0 ~ A12
Input
Address Inputs: Provide the row address for ACTIVE commands, and the column address
and AUTO PRECHARGE bit for READ/WRITE commands, to select one location out of the
memory array in the respective bank. A10 is sampled during a precharge command to
determine whether the PRECHARGE applies to one bank (A10 LOW) or all banks (A10
HIGH). If only one bank is to be precharged, the bank is selected by BA0, BA1. The
address inputs also provide the op code during a MODE REGISTER SET command. BA0 and
BA1 define which mode register is loaded during the MODE REGISTER SET command (MRS
or EMRS).
/RAS, /CAS, /WE
Input
Command Inputs: /RAS, /CAS and /WE (along with /CS) define the command being
entered.
DM
(LDM,UDM)
Input
Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM
is sampled HIGH along with that input data during a WRITE access. DM is sampled on both
edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS
loading. For the x16, LDM corresponds to the data on DQ0-Q7; UDM corresponds to the
data on DQ8-Q15.
DQS
(LDQS,UDQS)
I/O
Data Strobe: Output with read data, input with write data. Edge aligned with read data,
centered in write data. Used to capture write data. For the x16, LDQS corresponds to the
data on DQ0-Q7; UDQS corresponds to the data on DQ8-Q15.
DQ
I/O
Data input / output pin: Data bus
VDD/VSS
Supply
Power supply for internal circuits and input buffers.
VDDQ/VSSQ
Supply
Power supply for output buffers for noise immunity.
VREF
Supply
Reference voltage for inputs for SSTL interface.
NC
NC
Rev. 1.0 /Nov. 2007
DESCRIPTION
No connection.
5
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
FUNCTIONAL BLOCK DIAGRAM (32Mx8)
4Banks x 8Mbit x 8 I/O Double Data Rate Synchronous DRAM
Input Buffer
8
Write Data Register
2-bit Prefetch Unit
16
8Mx8 / Bank0
8Mx8 / Bank2
16
8Mx8 / Bank3
Mode
Register
8
Output Buffer
8Mx8 / Bank1
Command
Decoder
2-bit Prefetch Unit
Bank
Control
Sense AMP
CLK
/CLK
CKE
/CS
/RAS
/CAS
/WE
DQS
DM
DQ[0:7]
Row
Decoder
Column Decoder
ADD
BA
DQS
Address
Buffer
Column Address
Counter
CLK_DLL
DQS
CLK,
/CLK
Data Strobe
Transmitter
Data Strobe
Receiver
DLL
Block
Mode
Register
Rev. 1.0 /Nov. 2007
6
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
FUNCTIONAL BLOCK DIAGRAM (16Mx16)
4Banks x 4Mbit x 16 I/O Double Data Rate Synchronous DRAM
Input Buffer
16
Write Data Register
2-bit Prefetch Unit
32
4Mx16 / Bank0
4Mx16 / Bank2
32
4Mx16 / Bank3
Mode
Register
16
LDM, UDM
Output Buffer
4Mx16 / Bank1
Command
Decoder
2-bit Prefetch Unit
Bank
Control
Sense AMP
CLK
/CLK
CKE
/CS
/RAS
/CAS
/WE
LDQS, UDQS
DQ[0:15]
Row
Decoder
Column Decoder
ADD
BA
LDQS, UDQS
Address
Buffer
Column Address
Counter
CLK_DLL
LDQS
UDQS
CLK,
/CLK
Data Strobe
Transmitter
Data Strobe
Receiver
DLL
Block
Mode
Register
Rev. 1.0 /Nov. 2007
7
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
SIMPLIFIED COMMAND TRUTH TABLE
Command
CKEn-1
CKEn
/CS
/RAS
/CAS
/WE
H
X
L
L
L
L
OP code
H
X
L
L
L
L
OP code
H
X
H
X
X
X
L
H
H
H
H
X
L
L
H
H
H
X
L
H
L
H
CA
H
X
L
H
L
L
CA
H
X
L
L
H
L
X
Read Burst Stop1
H
X
L
H
H
L
X
Auto Refresh1
H
H
L
L
L
H
X
Entry
H
L
L
L
L
H
Exit
L
H
H
X
X
X
Extended Mode Register Set1,2
1,2
Mode Register Set
1
Device Deselect
No Operation1
Bank Active1
Read1
Read with Autoprecharge
1,3
Write1
Write with Autoprecharge1,4
Precharge All Banks1,5
Precharge selected Bank1
Self Refresh1
Entry
H
L
Exit
L
H
Entry
H
L
Exit
L
H
Precharge Power
1
Down Mode
Active Power
Down Mode1
L
H
H
H
H
X
X
X
L
H
H
H
H
X
X
X
L
H
H
H
H
X
X
X
L
V
V
V
ADDR
A10/AP
BA
X
RA
V
L
H
L
H
V
V
H
X
L
V
X
X
X
X
( H=Logic High Level, L=Logic Low Level, X=Don’t Care, V=Valid Data Input, OP Code=Operand Code, NOP=No Operation )
Note:
1. LDM/UDM states are Don’t Care. Refer to below Write Mask Truth Table.
2. OP Code(Operand Code) consists of A0~A12 and BA0~BA1 used for Mode Register setting during Extended MRS or MRS.
Before entering Mode Register Set mode, all banks must be in a precharge state and MRS command can be issued after tRP
period from Precharge command.
3. If a Read with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented
to activated bank until CK(n+BL/2+tRP).
4. If a Write with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented
to activated bank until CK(n+BL/2+1+tWR+tRP). Write Recovery Time(tWR) is needed to guarantee that the last data has been
completely written.
5. If A10/AP is High when Precharge command being issued, BA0/BA1 are ignored and all banks are selected to be precharged.
*For more information about Truth Table, refer to “Device Operation” section in Hynix website.
Rev. 1.0 /Nov. 2007
8
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
WRITE MASK TRUTH TABLE
CKEn-1
CKEn
/CS, /RAS,
/CAS, /WE
DM
Data Write1
H
X
X
L
X
Data-In Mask1
H
X
X
H
X
Function
ADDR
A10/AP
BA
Note:
1. Write Mask command masks burst write data with reference to LDQS/UDQS(Data Strobes) and it is not related with read data.
In case of x16 data I/O, LDM and UDM control lower byte(DQ0~7) and Upper byte(DQ8~15) respectively.
Rev. 1.0 /Nov. 2007
9
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
SIMPLIFIED STATE DIAGRAM
Pow er
A p p lie d
Pow er
On
P re c h a rg
e
PREALL
S e lf
R e fre s h
REFS
REFSX
MRS
MRS
EM RS
REFA
Id le
A u to
R e fre s h
CKEL
CKEH
A c t iv e
Power
Down
P re c h a rg
e
Pow er
Down
ACT
CKEH
CKEL
B u rs t
S to p
Row
A c t iv e
W r it e
Read
W r it e
Read
W r it e A
Read A
W r it e
Read
Read
W r it e A
Read A
Read A
W r it e A
Read A
PRE
PRE
PRE
PRE
P re c h a rg
e
PREALL
A u t o m a t ic S e q u e n c e
C om m and Sequence
P R E A L L = P r e c h a r g e A ll B a n k s
M R S = M o d e R e g is t e r S e t
E M R S = E x t e n d e d M o d e R e g is t e r S e t
R E F S = E n t e r S e lf R e f r e s h
R E F S X = E x it S e lf R e f r e s h
R E F A = A u to R e f r e s h
Rev. 1.0 /Nov. 2007
C K E L = E n te r P o w e r D o w n
C K E H = E x it P o w e r D o w n
A C T = A c t iv e
W r it e A = W r it e w it h A u t o p r e c h a r g e
R e a d A = R e a d w it h A u t o p r e c h a r g e
P R E = P re c h a rg e
10
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
POWER-UP SEQUENCE AND DEVICE INITIALIZATION
DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those
specified may result in undefined operation. Power must first be applied to VDD, then to VDDQ, and finally to VREF
(and to the system VTT). VTT must be applied after VDDQ to avoid device latch-up, which may cause permanent damage to the device. VREF can be applied anytime after VDDQ, but is expected to be nominally coincident with VTT.
Except for CKE, inputs are not recognized as valid until after VREF is applied. CKE is an SSTL_2 input, but will detect an
LVCMOS LOW level after VDD is applied. Maintaining an LVCMOS LOW level on CKE during power-up is required to
guarantee that the DQ and DQS outputs will be in the High-Z state, where they will remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR
SDRAM requires a 200us delay prior to applying an executable command.
Once the 200us delay has been satisfied, a DESELECT or NOP command should be applied, and CKE should be
brought HIGH. Following the NOP command, a PRECHARGE ALL command should be applied. Next a EXTENDED
MODE REGISTER SET command should be issued for the Extended Mode Register, to enable the DLL, then a MODE
REGISTER SET command should be issued for the Mode Register, to reset the DLL, and to program the operating
parameters. After the DLL reset, tXSRD(DLL locking time) should be satisfied for read command. After the Mode Register set command, a PRECHARGE ALL command should be applied, placing the device in the all banks idle state.
Once in the idle state, two AUTO REFRESH cycles must be performed. Additionally, a MODE REGISTER SET command
for the Mode Register, with the reset DLL bit deactivated low (i.e. to program operating parameters without resetting
the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation.
1.
Apply power - VDD, VDDQ, VTT, VREF in the following power up sequencing and attempt to maintain CKE at LVCMOS low state. (All the other input pins may be undefined.)
• VDD and VDDQ are driven from a single power converter output.
• VTT is limited to 1.44V (reflecting VDDQ(max)/2 + 50mV VREF variation + 40mV VTT variation.
• VREF tracks VDDQ/2.
• A minimum resistance of 42 Ohms (22 ohm series resistor + 22 ohm parallel resistor - 5% tolerance) limits the
input current from the VTT supply into any pin.
• If the above criteria cannot be met by the system design, then the following sequencing and voltage relationship must be adhered to during power up.
Voltage description
Sequencing
Voltage relationship to avoid latch-up
VDDQ
After or with VDD
< VDD + 0.3V
VTT
After or with VDDQ
< VDDQ + 0.3V
VREF
After or with VDDQ
< VDDQ + 0.3V
2.
Start clock and maintain stable clock for a minimum of 200usec.
3.
After stable power and clock, apply NOP condition and take CKE high.
4.
Issue Extended Mode Register Set (EMRS) to enable DLL.
5.
Issue Mode Register Set (MRS) to reset DLL and set device to idle state with bit A8=high. (An additional 200
cycles(tXSRD) of clock are required for locking DLL)
6.
Issue Precharge commands for all banks of the device.
7.
Issue 2 or more Auto Refresh commands.
8.
Issue a Mode Register Set command to initialize the mode register with bit A8 = Low
Rev. 1.0 /Nov. 2007
11
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
Power-Up Sequence
VDD
VDDQ
tVTD
VTT
VREF
/CLK
CLK
tIS tIH
CKE
LVCMOS Low Level
CMD
NOP
PRE
EMRS
MRS
ADDR
CODE
A10
BA0, BA1
NOP
PRE
AREF
MRS
ACT
RD
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
CODE
Non-Read
Command
READ
DM
DQS
DQ'S
T=200usec
tRP
tMRD
tMRD
tRP
tRFC
tMRD
tXSRD*
Power UP
VDD and CK stable
Precharge All
EMRS Set
MRS Set
Reset DLL
(with A8=H)
Precharge All
2 or more
Auto Refresh
MRS Set
(with A8=L)
* 200 cycle(tXSRD) of CK are required (for DLL locking) before Read Command
Rev. 1.0 /Nov. 2007
12
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
MODE REGISTER SET (MRS)
The mode register is used to store the various operating modes such as /CAS latency, addressing mode, burst length,
burst type, test mode, DLL reset. The mode register is programed via MRS command. This command is issued by the
low signals of /RAS, /CAS, /CS, /WE and BA0. This command can be issued only when all banks are in idle state and
CKE must be high at least one cycle before the Mode Register Set Command can be issued. Two cycles are required to
write the data in mode register. During the MRS cycle, any command cannot be issued. Once mode register field is
determined, the information will be held until reset by another MRS command.
BA1
BA0
0
0
A12
A11
A10
A9
A8
A7
Operating Mode
A6
A5
A4
CAS Latency
A3
A2
BT
A1
Burst Length
BA0
MRS Type
A6
A5
A4
CAS Latency
A3
Burst Type
0
MRS
0
0
0
Reserved
0
Sequential
1
EMRS
0
0
1
Reserved
1
Interleave
0
1
0
2
0
1
1
3
1
0
0
Reserved
1
0
1
1.5
1
1
0
2.5
1
1
1
Reserved
A0
Burst Length
A2
A1
A0
Sequential
Interleave
0
0
0
Reserved
Reserved
0
0
1
2
2
0
1
0
4
4
A12~A9
A8
A7
A6~A0
Operating Mode
0
1
1
8
8
0
0
0
Valid
Normal Operation
1
0
0
Reserved
Reserved
0
1
0
Valid
Normal Operation/ Reset DLL
1
0
1
Reserved
Reserved
0
0
1
VS
Vendor specific Test Mode
1
1
0
Reserved
Reserved
-
-
-
-
All other states reserved
1
1
1
Reserved
Reserved
Rev. 1.0 /Nov. 2007
13
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
BURST DEFINITION
Burst Length
Starting Address (A2,A1,A0)
Sequential
Interleave
XX0
0, 1
0, 1
XX1
1, 0
1, 0
X00
0, 1, 2, 3
0, 1, 2, 3
X01
1, 2, 3, 0
1, 0, 3, 2
X10
2, 3, 0, 1
2, 3, 0, 1
X11
3, 0, 1, 2
3, 2, 1, 0
000
0, 1, 2, 3, 4, 5, 6, 7
0, 1, 2, 3, 4, 5, 6, 7
001
1, 2, 3, 4, 5, 6, 7, 0
1, 0, 3, 2, 5, 4, 7, 6
010
2, 3, 4, 5, 6, 7, 0, 1
2, 3, 0, 1, 6, 7, 4, 5
011
3, 4, 5, 6, 7, 0, 1, 2
3, 2, 1, 0, 7, 6, 5, 4
100
4, 5, 6, 7, 0, 1, 2, 3
4, 5, 6, 7, 0, 1, 2, 3
101
5, 6, 7, 0, 1, 2, 3, 4
5, 4, 7, 6, 1, 0, 3, 2
110
6, 7, 0, 1, 2, 3, 4, 5
6, 7, 4, 5, 2, 3, 0, 1
111
7, 0, 1, 2, 3, 4, 5, 6
7, 6, 5, 4, 3, 2, 1, 0
2
4
8
BURST LENGTH & TYPE
Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The burst
length determines the maximum number of column locations that can be accessed for a given Read or Write command. Burst lengths of 2, 4 or 8 locations are available for both the sequential and the interleaved burst types.
Reserved states should not be used, as unknown operation or incompatibility with future versions may result.
When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All
accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is
reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2 -Ai when the burst length
is set to four and by A3 -Ai when the burst length is set to eight (where Ai is the most significant column address bit
for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location
within the block. The programmed burst length applies to both Read and Write bursts.
Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the
burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the
burst type and the starting column address, as shown in Burst Definition Table
Rev. 1.0 /Nov. 2007
14
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
CAS LATENCY
The Read latency or CAS latency is the delay in clock cycles between the registration of a Read command and the
availability of the first burst of output data. The latency can be programmed 2 or 2.5 clocks for DDR200/266/333 and
3 clocks for DDR400.
If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally coincident
with clock edge n + m.
Reserved states should not be used as unknown operation or incompatibility with future versions may result.
DLL RESET
The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is automatically
disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any
time the DLL is enabled, 200 clock cycles must occur to allow time for the internal clock to lock to the externally
applied clock before an any command can be issued.
OUTPUT DRIVER IMPEDANCE CONTROL
The normal drive strength for all outputs is specified to be SSTL_2, Class II. Hynix also supports a half strength driver
option, intended for lighter load and/or point-to-point environments. Selection of the half strength driver option will
reduce the output drive strength by 50% of that of the full strength driver. I-V curves for both the full strength driver
and the half strength driver are included in this document.
Rev. 1.0 /Nov. 2007
15
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
EXTENDED MODE REGISTER SET (EMRS)
The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional functions include DLL enable/disable, output driver strength selection(optional). These functions are controlled via the bits
shown below. The Extended Mode Register is programmed via the Mode Register Set command (BA0=1 and BA1=0)
and will retain the stored information until it is programmed again or the device loses power.
The Extended Mode Register must be loaded when all banks are idle and no bursts are in progress, and the controller
must wait the specified time before initiating any subsequent operation. Violating either of these requirements will
result in unspecified operation.
BA1
BA0
0
1
A12
A11
A10
A9
A8
A7
A6
A5
A4
Operating Mode
BA0
MRS Type
0
MRS
1
EMRS
An~A3
A2~A0
Operating Mode
0
Valid
Normal Operation
_
_
All other states reserved
A3
A2
A1
A0
0*
DS
DLL
A0
DLL enable
0
Enable
1
Disable
A1
Output Driver
Impedance Control
0
Full Strength Driver
1
Half Strength Driver
* This part do not support/QFC function, A2 must be programmed to Zero.
Rev. 1.0 /Nov. 2007
16
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Rating
TA
-40 ~ 85
o
C
Storage Temperature
TSTG
-55 ~ 150
o
C
Voltage on VDD relative to VSS
VDD
-1.0 ~ 3.6
V
Voltage on VDDQ relative to VSS
VDDQ
-1.0 ~ 3.6
V
Voltage on inputs relative to VSS
VINPUT
-1.0 ~ 3.6
V
Voltage on I/O pins relative to VSS
VIO
-0.5 ~3.6
V
Output Short Circuit Current
IOS
50
Operating Temperature (Ambient)
Soldering Temperature ⋅ Time
Unit
mA
oC
260 ⋅ 10
TSOLDER
⋅ Sec
Note: Operation at above absolute maximum rating can adversely affect device reliability
DC OPERATING CONDITIONS (TA=-40 to 85 oC, Voltage referenced to VSS = 0V)
Parameter
Power Supply Voltage (DDR200, 266, 333)
Power Supply Voltage (DDR200, 266, 333)1
Power Supply Voltage (DDR400, 500)
Power Supply Voltage (DDR400, 500)1
Input High Voltage
2
Input Low Voltage
Termination Voltage
Symbol
Min
Typ.
Max
Unit
VDD
VDDQ
2.3
2.3
2.5
2.5
2.7
2.7
V
V
VDD
VDDQ
2.4
2.4
2.6
2.6
2.7
2.7
V
V
VIH
VIL
VREF + 0.15
-0.3
-
VDDQ + 0.3
VREF - 0.15
V
V
VTT
VREF
VREF - 0.04
0.49*VDDQ
VREF
0.5*VDDQ
VREF + 0.04
0.51*VDDQ
V
V
Reference Voltage3
Input Voltage Level, CK and CK inputs
VIN(DC)
-0.3
-
VDDQ+0.3
V
Input Differential Voltage, CK and CK inputs4
VID(DC)
0.36
-
VDDQ+0.6
V
Ratio5
VI(RATIO)
0.71
-
1.4
-
Input Leakage Current6
ILI
-2
-
2
uA
Output Leakage Current7
Output High Current
Normal Strength
(min VDDQ, min VREF, min VTT)
Output Driver
Output Low Current
ILO
-5
-
5
uA
IOH
-16.8
-
-
mA
IOL
16.8
-
-
mA
IOH
-13.6
-
-
mA
IOL
13.6
-
-
mA
V-I Matching: Pullup to Pulldown Current
(VOUT=VTT ± 0.84)
Half Strength Output Driver
(VOUT=VTT ± 0.68)
(min VDDQ, max VREF, max VTT)
Output High Current
(min VDDQ, min VREF, min VTT)
Output Low Current
(min VDDQ, max VREF, max VTT)
Note:
1. VDDQ must not exceed the level of VDD.
2. VIL (min) is acceptable -1.5V AC pulse width with < 5ns of duration.
3. VREF is expected to be equal to 0.5*VDDQ of the transmitting device, and to track variations in the dc level of the same.
Peak to peak noise on VREF may not exceed ± 2% of the DC value.
4. VID is the magnitude of the difference between the input level on CK and the input level on /CK.
5. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages from 0.25V to 1.0V. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. The full variation in the ratio of the maximum to minimum
pullup and pulldown current will not exceed 1/7 for device drain to source voltages from 0.1 to 1.0.
6. VIN=0 to VDD, All other pins are not tested under VIN =0V.
7. DQs are disabled, VOUT=0 to VDDQ
Rev. 1.0 /Nov. 2007
17
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
IDD SPECIFICATION AND CONDITIONS
(TA=-40 to 85 oC, Voltage referenced to VSS = 0V)
Test Conditions
Test Condition
Symbol
Operating Current:
One bank; Active - Precharge; tRC=tRC(min); tCK=tCK(min); DQ,DM and DQS inputs changing twice per clock
cycle; address and control inputs changing once per clock cycle
IDD0
Operating Current:
One bank; Active - Read - Precharge;
Burst Length=2; tRC=tRC(min); tCK=tCK(min); address and control inputs changing once per clock cycle
IDD1
Precharge Power Down Standby Current:
All banks idle; Power down mode; CKE=Low, tCK=tCK(min)
IDD2P
Idle Standby Current:
/CS=High, All banks idle; tCK=tCK(min);
CKE=High; address and control inputs changing once per clock cycle.
VIN=VREF for DQ, DQS and DM
IDD2F
Idle Quiet Standby Current:
/CS>=Vih(min); All banks idle; CKE>=Vih(min); Addresses and other control inputs stable, Vin=Vref for DQ, DQS
and DM
IDD2Q
Active Power Down Standby Current:
One bank active; Power down mode; CKE=Low, tCK=tCK(min)
IDD3P
Active Standby Current:
/CS=HIGH; CKE=HIGH; One bank; Active-Precharge; tRC=tRAS(max); tCK=tCK(min);
DQ, DM and DQS inputs changing twice per clock cycle; Address and other control inputs changing once per clock
cycle
IDD3N
Operating Current:
Burst=2; Reads; Continuous burst; One bank active; Address and control inputs changing once per clock cycle;
tCK=tCK(min); IOUT=0mA
IDD4R
Operating Current:
Burst=2; Writes; Continuous burst; One bank active; Address and control inputs changing once per clock cycle;
tCK=tCK(min); DQ, DM and DQS inputs changing twice per clock cycle
IDD4W
Auto Refresh Current:
tRC=tRFC(min) - 8*tCK for DDR200 at 100Mhz, 10*tCK for DDR266A & DDR266B at 133Mhz; distributed refresh
tRC=tRFC(min) - 14*tCK for DDR400 at 200Mhz
IDD5
Self Refresh Current:
CKE =< 0.2V; External clock on; tCK=tCK(min)
IDD6
Operating Current - Four Bank Operation:
Four bank interleaving with BL=4
IDD7
Rev. 1.0 /Nov. 2007
18
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
IDD Specification
32Mx8
Parameter
Symbol
Speed
DDR500
DDR400B
DDR333
DDR266A DDR266B
Unit
Operating Current
IDD0
100
90
80
70
mA
Operating Current
IDD1
110
100
100
90
mA
Precharge Power Down Standby Current
IDD2P
10
mA
Idle Standby Current
IDD2F
30
mA
Active Power Down Standby Current
IDD3P
Active Standby Current
IDD3N
30
70
60
60
mA
50
Operating Current
IDD4R
180
170
160
150
Operating Current
IDD4W
180
170
160
150
IDD5
160
150
150
140
Auto Refresh Current
Self Refresh Current
Normal
Low Power
Operating Current - Four Bank Operation
3
IDD6
IDD7
210
210
DDR500
DDR400B
DDR333
mA
mA
1.5
220
mA
mA
190
mA
16Mx16
Parameter
Symbol
Speed
DDR266A DDR266B
Unit
Operating Current
IDD0
100
90
80
70
mA
Operating Current
IDD1
110
100
100
90
mA
Precharge Power Down Standby Current
IDD2P
10
Idle Standby Current
IDD2F
30
mA
Active Power Down Standby Current
IDD3P
30
mA
Active Standby Current
IDD3N
70
60
60
50
Operating Current
IDD4R
180
170
160
150
Operating Current
IDD4W
180
170
160
150
IDD5
160
150
150
140
Auto Refresh Current
Self Refresh Current
Normal
Low Power
Operating Current - Four Bank Operation
Rev. 1.0 /Nov. 2007
3
IDD6
IDD7
mA
230
230
mA
mA
1.5
240
mA
mA
210
mA
19
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
AC OPERATING CONDITIONS (TA=-40 to 85 oC, Voltage referenced to VSS = 0V)
Parameter
Symbol
Min
Max
Unit
Input High (Logic 1) Voltage, DQ, DQS and DM signals
VIH(AC)
VREF + 0.31
-
V
Input Low (Logic 0) Voltage, DQ, DQS and DM signals
VIL(AC)
-
VREF - 0.31
V
Input Differential Voltage, CK and /CK inputs1
VID(AC)
0.7
VDDQ + 0.6
V
Input Crossing Point Voltage, CK and /CK inputs2
VIX(AC)
0.5*VDDQ-0.2
0.5*VDDQ+0.2
V
Note:
1. VID is the magnitude of the difference between the input level on CK and the input on /CK.
2. The value of VIX is expected to equal 0.5*V DDQ of the transmitting device and must track variations in the DC level of the same.
*For more information about AC Overshoot/Undershoot Specifications, refer to “Device Operation” section in hynix website.
AC OPERATING TEST CONDITIONS (TA=-40 to 85oC, Voltage referenced to VSS = 0V)
Parameter
Value
Unit
Reference Voltage
VDDQ x 0.5
V
Termination Voltage
VDDQ x 0.5
V
AC Input High Level Voltage (VIH, min)
VREF + 0.31
V
AC Input Low Level Voltage (VIL, max)
VREF - 0.31
V
Input Timing Measurement Reference Level Voltage
VREF
V
Output Timing Measurement Reference Level Voltage
VTT
V
Input Signal maximum peak swing
1.5
V
Input minimum Signal Slew Rate
1
V/ns
Termination Resistor (RT)
50
Ω
Series Resistor (RS)
25
W
Output Load Capacitance for Access Time Measurement (CL)
30
pF
Rev. 1.0 /Nov. 2007
20
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
AC CHARACTERISTICS (note: 1 - 9 / AC operating conditions unless otherwise noted)
Parameter
Symbol
DDR500
DDR400B
DDR333
DDR266A
DDR266B
DDR200
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
UN
Max IT
Row Cycle Time
tRC
50
-
55
-
60
-
65
-
65
-
70
-
ns
Auto Refresh Row Cycle
Time
tRFC
70
-
70
-
72
-
75
-
75
-
80
-
ns
Row Active Time
tRAS
35
70K
40
70K
42
70K
45
120K
45
120K
50
tRAP
tRCD or
tRASmin
-
tRCD or
tRASmin
-
tRCD or
tRASmin
-
tRCD or
tRASmin
-
tRCD or
tRASmin
-
tRCD or
tRASmin
-
ns
Row Address to Column
Address Delay
tRCD
16
-
15
-
18
-
20
-
20
-
20
-
ns
Row Active to Row
Active Delay
tRRD
8
-
10
-
12
-
15
-
15
-
15
-
ns
Column Address to
Column Address Delay
tCCD
1
-
1
-
1
-
1
-
1
-
1
-
tCK
Row Precharge Time
tRP
16
-
15
-
18
-
20
-
20
-
20
-
ns
Write Recovery Time
tWR
15
-
15
-
15
-
15
-
15
-
15
-
ns
Internal Write to Read
Command Delay
tWTR
2
-
2
-
1
-
1
-
1
-
1
-
tCK
-
tCK
-
ns
Active to Read with
Auto Precharge Delay
Auto Precharge Write
Recovery + Precharge
Time22
tDAL
(tWR/tCK)
+
-
(tRP/tCK)
tCK
Clock High Level Width
tCH
0.45
0.55
Clock Low Level Width
tCL
0.45
0.55
Data-Out edge to Clock
edge Skew
tAC
-0.65
0.65
-0.55
tDQSQ
tQH
DQS-Out edge to DataOut edge Skew21
Data-Out hold time
from DQS20
Clock Half Period19,20
Data Hold Skew
Factor20
Valid Data Output
Window
Rev. 1.0 /Nov. 2007
tHP
tQHS
tDV
+
(tWR/tCK)
-
(tRP/tCK)
CL = 3
System
Clock Cycle CL = 2.5
Time24
CL = 2
DQS-Out edge to Clock
tDQSCK
edge Skew
(tWR/tCK)
5
10
6
7.5
+
-
7.5
(tWR/tCK)
-
(tRP/tCK)
+
(tRP/tCK)
-
-
-
-
-
12
6
12
7.5
12
7.5
12
8.0
12
ns
12
7.5
12
7.5
12
10
12
10
12
ns
0.45
0.55
0.45
0.55
0.45
0.55
0.45
0.55
0.45
0.55 tCK
0.45
0.55
0.45
0.55
0.45
0.55
0.45
0.55
0.45
0.55 tCK
-0.7
0.7
-0.7
0.7
-0.75
0.75
-0.75
0.75
-0.75
0.75 ns
0.55
-0.55
0.55
-0.6
0.6
-0.75
0.75
-0.75
0.75
-0.75
0.75 ns
-
0.35
-
0.4
-
0.45
-
0.5
-
0.5
-
0.6
ns
tHP
-tQHS
-
tHP
-tQHS
-
tHP
-tQHS
-
tHP
-tQHS
-
tHP
-tQHS
-
tHP
-tQHS
-
ns
-
ns
-
6
12
+
-
min
12
(tWR/tCK)
-
-
(tCL,tCH)
10
+
(tRP/tCK)
(tRP/tCK)
5
(tWR/tCK)
120K ns
0.5
tQH-tDQSQ
min
(tCL,tCH)
-
0.5
tQH-tDQSQ
min
(tCL,tCH)
-
0.55
tQH-tDQSQ
min
(tCL,tCH)
-
0.75
tQH-tDQSQ
min
(tCL,tCH)
-
0.75
tQH-tDQSQ
min
(tCL,tCH)
-
0.75 ns
tQH-tDQSQ
ns
21
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
- Continue
Parameter
DDR266A
DDR266B
Min Max Min Max Min Max
Min
Min
Max
Min
tHZ
-0.65 0.65
-0.7
0.7
-0.7
0.7
-0.75 0.75 -0.75 0.75
-0.8
0.8
ns
tLZ
-0.65 0.65
-0.7
0.7
-0.7
0.7
-0.75 0.75 -0.75 0.75
-0.8
0.8
ns
Symbol
Data-out high-impedance window
from CK,/CK10
Data-out low-impedance window
from CK, /CK10
Input Setup Time (fast slew
DDR500
DDR400B
DDR333
Max
DDR200
UN
Max IT
tIS
0.6
-
0.6
-
0.75
-
0.9
-
0.9
-
1.1
-
ns
tIH
0.6
-
0.6
-
0.75
-
0.9
-
0.9
-
1.1
-
ns
tIS
0.6
-
0.7
-
0.8
-
1.0
-
1.0
-
1.1
-
ns
tIH
0.6
-
0.7
-
0.8
-
1.0
-
1.0
-
1.1
-
ns
tIPW
2.2
-
2.2
-
2.2
-
2.2
-
2.2
-
2.5
-
ns
Write DQS High Level Width
tDQSH
0.35
-
0.35
-
0.35
-
0.35
-
0.35
-
0.35
-
tCK
Write DQS Low Level Width
tDQSL
0.35
-
0.35
-
0.35
-
0.35
-
0.35
-
0.35
-
tCK
Clock to First Rising edge of DQSIn
tDQSS
0.72 1.25 0.72 1.25
0.75 1.25
0.75
1.25
0.75
1.25
0.75
1.25
tCK
DQS falling edge to CK setup time
tDSS
0.2
-
0.2
-
0.2
-
0.2
-
0.2
-
0.2
-
tCK
DQS falling edge hold time from
CK
tDSH
0.2
-
0.2
-
0.2
-
0.2
-
0.2
-
0.2
-
tCK
DQ & DM input setup time25
tDS
0.4
-
0.4
-
0.45
-
0.5
-
0.5
-
0.6
-
ns
DQ & DM input hold time25
tDH
0.4
-
0.4
-
0.45
-
0.5
-
0.5
-
0.6
-
ns
DQ & DM Input Pulse Width17
tDIPW
1.6
-
1.75
-
1.75
-
1.75
-
1.75
-
2
-
ns
Read DQS Preamble Time
tRPRE
0.9
1.1
0.9
1.1
0.9
1.1
0.9
1.1
0.9
1.1
0.9
1.1
tCK
Read DQS Postamble Time
tRPST
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
tCK
0
-
0
-
0
-
0
-
0
-
0
-
ns
-
0.25
-
0.25
-
0.25
-
0.25
-
0.25
-
tCK
rate)14,16-18
Input Hold Time (fast slew
rate)14,16-18
Input Setup Time (slow slew
rate)15-18
Input Hold Time (slow slew
rate)15-18
Input Pulse Width17
Write DQS Preamble Setup Time12 tWPRES
Write DQS Preamble Hold Time
Write DQS Postamble Time
11
Mode Register Set Delay
Exit Self Refresh to non-Read
command23
Exit Self Refresh to Read
command
Average Periodic Refresh
Interval13,25
Rev. 1.0 /Nov. 2007
tWPREH 0.25
tWPST
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
0.4
0.6
tCK
tMRD
2
-
2
-
2
-
2
-
2
-
2
-
tCK
tXSNR
75
-
75
-
75
-
75
-
75
-
80
-
ns
tXSRD
200
-
200
-
200
-
200
-
200
-
200
-
tCK
tREFI
-
7.8
-
7.8
-
7.8
-
7.8
-
7.8
-
7.8
us
22
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
Note:
1. All voltages referenced to Vss.
2. Tests for ac timing, IDD, and electrical, ac and dc characteristics, may be conducted at nominal reference/supply voltage levels,
but the related specifications and device operation are guaranteed for the full voltage range specified.
3. Below figure represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to
be either a precise representation of the typical system environment nor a depiction of the actual load presented by a production
tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment.
Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester electronics).
VDDQ
Output
(VOUT)
50 Ω
30 pF
Figure: Timing Reference Load
4. AC timing and IDD tests may use a VIL to VIHswing of up to 1.5 V in the test environment, but input timing is still referenced to
VREF (or to the crossing point for CK, /CK), and parameter specifications are guaranteed for the specified ac input levels under
normal use conditions. The minimum slew rate for the input signals is 1 V/ns in the range between VIL(ac) and VIH(ac).
5. The ac and dc input level specifications are as defined in the SSTL_2 Standard (i.e., the receiver will effectively switch as a result
of the signal crossing the ac input level and will remain in that state as long as the signal does not ring back above (below) the
dc input LOW (HIGH) level.
6. Inputs are not recognized as valid until VREF stabilizes. Exception: during the period before VREF stabilizes, CKE < 0.2VDDQ is
recognized as LOW.
7. The CK, /CK input reference level (for timing referenced to CK, /CK) is the point at which CK and /CK cross; the input reference
level for signals other than CK, /CK is VREF.
8. The output timing reference voltage level is VTT.
9. Operation or timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must
be powered down and then restarted through the specified initialization sequence before normal operation can continue.
10. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to
a specific voltage level but specify when the device output is no longer driving (HZ), or begins driving (LZ).
11. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but
system performance (bus turnaround) will degrade accordingly.
12. The specific requirement is that DQS be valid (HIGH, LOW, or at some point on a valid transition) on or before this CK edge. A
valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from High-Z to logic LOW. If a previous write was in progress, DQS could
be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS.
13. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device.
14. For command/address input slew rate ≥ 1.0 V/ns.
15. For command/address input slew rate ≥ 0.5 V/ns and < 1.0 V/ns
16. For CK & /CK slew rate ≥ 1.0 V/ns (single-ended)
17. These parameters guarantee device timing, but they are not necessarily tested on each device.
They may be guaranteed by device design or tester correlation.
18. Slew Rate is measured between VOH(ac) and VOL(ac).
19. Min (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this
value can be greater than the minimum specification limits for tCL and tCH).
For example, tCL and tCH are = 50% of the period, less the half period jitter (tJIT(HP)) of the clock source, and less the half
period jitter due to crosstalk (tJIT(crosstalk)) into the clock traces.
Rev. 1.0 /Nov. 2007
23
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
20.tQH = tHP - tQHS, where:
tHP = minimum half clock period for any given cycle and is defined by clock high or clock low (tCH, tCL). tQHS accounts for 1) The
pulse duration distortion of on-chip clock circuits; and 2) The worst case push--out of DQS on one transition followed by the
worst case pull--in of DQ on the next transition, both of which are, separately, due to data pin skew and output pattern effects,
and p-channel to n-channel variation of the output drivers.
21. tDQSQ:
Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers for any given
cycle.
22. tDAL = (tWR/tCK) + (tRP/tCK)
For each of the terms above, if not already an integer, round to the next highest integer.
Example: For DDR266B at CL=2.5 and tCK=7.5 ns
tDAL = ((15 ns / 7.5 ns) + (20 ns / 7.5 ns)) clocks
= ((2) + (3)) clocks
= 5 clocks
23. In all circumstances, tXSNR can be satisfied using
tXSNR = tRFCmin + 1*tCK
24. The only time that the clock frequency is allowed to change is during self-refresh mode.
25. If refresh timing or tDS/tDH is violated, data corruption may occur and the data must be re-written with valid data before a valid
READ can be executed.
Rev. 1.0 /Nov. 2007
24
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
SYSTEM CHARACTERISTICS CONDITIONS for DDR SDRAMS
The following tables are described specification parameters that required in systems using DDR devices to ensure
proper performannce. These characteristics are for system simulation purposes and are guaranteed by design.
Input Slew Rate for DQ/DM/DQS
AC CHARACTERISTICS
PARAMETER
DQ/DM/DQS input slew rate
measured between VIH(DC),
VIL(DC) and VIL(DC), VIH(DC)
(Table a.)
DDR500
DDR400
DDR333
DDR266
DDR200
Symbol
min
max
min
max
min
max
min
max
min
max
DCSLEW
0.5
4.0
0.5
4.0
0.5
4.0
0.5
4.0
0.5
4.0
UNIT
Note
V/ns
1,12
Address & Control Input Setup & Hold Time Derating (Table b.)
Input Slew Rate
Delta tIS
Delta tIH
UNIT
Note
0.5 V/ns
0
0
ps
9
0.4 V/ns
+50
0
ps
9
0.3 V/ns
+100
0
ps
9
DQ & DM Input Setup & Hold Time Derating
(Table c.)
Input Slew Rate
Delta tDS
Delta tDH
UNIT
Note
0.5 V/ns
0
0
ps
11
0.4 V/ns
+75
0
ps
11
0.3 V/ns
+150
0
ps
11
DQ & DM Input Setup & Hold Time Derating for Rise/Fall Delta Slew Rate
(Table d.)
Input Slew Rate
Delta tDS
Delta tDH
UNIT
Note
± 0.0 ns/V
0
0
ps
10
± 0.25 ns/V
+50
+50
ps
10
± 0.5 ns/V
+100
+100
ps
10
Output Slew Rate Characteristics (for x8 Devices)
(Table e.)
Slew Rate Characteristic
Typical Range (V/
ns)
Minimum (V/ns)
Maximum (V/ns)
Note
Pullup Slew Rate
1.2 - 2.5
1.0
4.5
1,3,4,6,7,8
Pulldown Slew Rate
1.2 - 2.5
1.0
4.5
2,3,4,6,7,8
Output Slew Rate Characteristics (for x16 Device) (Table f.)
Slew Rate Characteristic
Typical Range (V/
ns)
Minimum (V/ns)
Maximum (V/ns)
Note
Pullup Slew Rate
1.2 - 2.5
1.0
4.5
1,3,4,6,7,8
Pulldown Slew Rate
1.2 - 2.5
1.0
4.5
2,3,4,6,7,8
Output Slew Rate Matching Ratio Characteristics
Slew Rate Characteristic
Parameter
Output Slew Rate Matching Ratio
(Pullup to Pulldown)
Rev. 1.0 /Nov. 2007
DDR266A
(Table g.)
DDR266B
DDR200
min
max
min
max
min
max
-
-
-
-
0.71
1.4
Note
5,12
25
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
Note:
1. Pullup slew rate is characterized under the test conditions as shown in below Figure.
Test Point
Output
(VOUT)
50
Ω
VSSQ
Figure: Pullup Slew rate
2. Pulldown slew rate is measured under the test conditions shown in below Figure.
VDDQ
Output
(VOUT)
50Ω
Test Point
Figure: Pulldown Slew rate
3. Pullup slew rate is measured between (VDDQ/2 - 320 mV ± 250mV)
Pulldown slew rate is measured between (VDDQ/2 + 320mV ± 250mV)
Pullup and Pulldown slew rate conditions are to be met for any pattern of data, including all outputs switching and only one output
switching.
Example: For typical slew, DQ0 is switching
For minimum slew rate, all DQ bits are switching worst case pattern
For maximum slew rate, only one DQ is switching from either high to low, or low to high.
The remaining DQ bits remain the same as for previous state.
4. Evaluation conditions
Typical: 25 oC (Ambient), VDDQ = nominal, typical process
Minimum: 85 oC (Ambient), VDDQ = minimum, slow-slow process
Maximum: -40 oC (Ambient), VDDQ = Maximum, fast-fast process
5. The ratio of pullup slew rate to pulldown slew rate is specified for the same temperature and voltage, over the entire temperature
and voltage range. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process
variation.
6. Verified under typical conditions for qualification purposes.
7. TSOP-II package devices only.
8. Only intended for operation up to 256 Mbps per pin.
9. A derating factor will be used to increase tIS and tIH in the case where the input slew rate is below 0.5 V/ns as shown in Table b.
The Input slew rate is based on the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions.
10. A derating factor will be used to increase tDS and tDH in the case where DQ, DM, and DQS slew rates differ, as shown in Tables c
& d. Input slew rate is based on the larger of AC-AC delta rise, fall rate and DC-DC delta rise, fall rate. Input slew rate is based on
the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions. The
delta rise/fall rate is calculated as:
{1/(Slew Rate1)} - {1/(slew Rate2)}
For example:
If Slew Rate 1 is 0.5 V/ns and Slew Rate 2 is 0.4 V/ns, then the delta rise, fall rate is -0.5 ns/V. Using the table given, this would
result in the need for an increase in tDS and tDH of 100ps.
11. Table c is used to increase tDS and tDH in the case where the I/O slew rate is below 0.5 V/ns. The I/O slew rate is based on the
lesser of the AC-AC slew rate and the DC-DC slew rate. The input slew rate is based on the lesser of the slew rates determined by
either VIH(ac) to VIL(AC) or VIH(DC) to VIL(DC), and similarly for rising transitions.
12. DQS, DM, and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transitions through the DC region must be monotonic.
Rev. 1.0 /Nov. 2007
26
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
CAPACITANCE (TA=25oC, f=100MHz)
Parameter
Pin
Symbol
Min
Max
Unit
Input Clock Capacitance
CK, /CK
CI1
2.0
3.0
pF
Delta Input Clock Capacitance
CK, /CK
Delta CI1
-
0.25
pF
Input Capacitance
All other input-only pins
CI1
2.0
3.0
pF
Delta Input Capacitance
All other input-only pins
Delta CI2
-
0.5
pF
Input / Output Capacitance
DQ, DQS, DM
CIO
4.0
5.0
pF
Delta Input / Output Capacitance
DQ, DQS, DM
Delta CIO
-
0.5
pF
Note:
1. VDD = min. to max., VDDQ = 2.3V to 2.7V, VODC = VDDQ/2, VOpeak-to-peak = 0.2V
2. Pins not under test are tied to GND.
3. These values are guaranteed by design and are tested on a sample basis only.
OUTPUT LOAD CIRCUIT
V TT
R T =50Ω
Output
Zo=50Ω
V REF
C L =30pF
Rev. 1.0 /Nov. 2007
27
HY5DU56822F(L)TP-xxI
HY5DU561622F(L)TP-xxI
PACKAGE INFORMATION
400mil 66pin Thin Small Outline Package
Unit : mm(Inch)
,
max
min
11.94 (0.470)
11.79 (0.462)
10.26 (0.404)
10.05 (0.396)
BASE PLANE
22.33 (0.879)
22.12 (0.871)
0.65 (0.0256) BSC
1.194 (0.0470)
0.991 (0.0390)
Rev. 1.0 /Nov. 2007
0.35 (0.0138)
0.25 (0.0098)
0 ~ 5 Deg.
SEATING PLANE
0.15 (0.0059)
0.05 (0.0020)
0.597 (0.0235)
0.406 (0.0160)
0.210 (0.0083)
0.120 (0.0047)
28
Similar pages