IDT IDT72245LB25PF Cmos syncfifoo 256 x 18, 512 x 18, 1024 x 18, 2048 x 18 and 4096 x 18 Datasheet

IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
IDT72205LB
IDT72215LB
IDT72225LB
IDT72235LB
IDT72245LB
CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18,
2,048 x 18 and 4,096 x 18
Integrated Device Technology, Inc.
FEATURES:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
256 x 18-bit organization array (IDT72205LB)
512 x 18-bit organization array (IDT72215LB)
1,024 x 18-bit organization array (IDT72225LB)
2,048 x 18-bit organization array (IDT72235LB)
4,096 x 18-bit organization array (IDT72245LB)
10 ns read/write cycle time
Empty and Full flags signal FIFO status
Easily expandable in depth and width
Asynchronous or coincident read and write clocks
Programmable Almost-Empty and Almost-Full flags with
default settings
Half-Full flag capability
Dual-Port zero fall-through time architecture
Output enable puts output data bus in high-impedance
state
High-performance submicron CMOS technology
Available in a 64-lead thin quad flatpack (TQFP/STQFP)
and plastic leaded chip carrier (PLCC)
Industrial temperature range (–40°C to +85°C) is available
DESCRIPTION:
The IDT72205LB/72215LB/72225LB/72235LB/72245LB
are very high-speed, low-power First-In, First-Out (FIFO)
memories with clocked read and write controls. These FIFOs
are applicable for a wide variety of data buffering needs, such
as optical disk controllers, Local Area Networks (LANs), and
interprocessor communication.
These FIFOs have 18-bit input and output ports. The input
port is controlled by a free-running clock (WCLK), and an input
enable pin (WEN). Data is read into the synchronous FIFO on
every clock when WEN is asserted. The output port is controlled
by another clock pin (RCLK) and another enable pin (REN). The
read clock can be tied to the write clock for single clock
operation or the two clocks can run asynchronous of one
another for dual-clock operation. An Output Enable pin (OE) is
provided on the read port for three-state control of the output.
The synchronous FIFOs have two fixed flags, Empty (EF) and
Full (FF), and two programmable flags, Almost-Empty (PAE)
and Almost-Full (PAF). The offset loading of the programmable
flags is controlled by a simple state machine, and is initiated by
asserting the Load pin (LD). A Half-Full flag (HF) is available
when the FIFO is used in a single device configuration.
These devices are depth expandable using a Daisy-Chain
technique. The XI and XO pins are used to expand the FIFOs.
In depth expansion configuration, FL is grounded on the first
device and set to HIGH for all other devices in the Daisy Chain.
The IDT72205LB/72215LB/72225LB/72235LB/72245LB is
fabricated using IDT’s high-speed submicron CMOS technology.
FUNCTIONAL BLOCK DIAGRAM
WCLK
D0-D17
INPUT REGISTER
WRITE CONTROL
LOGIC
WRITE POINTER
(
)/
••
RAM ARRAY
256 x 18, 512 x 18
1,024 x 18, 2,048 x 18
4,096 x 18
••
OFFSET REGISTER
FLAG
LOGIC
/(
)
READ POINTER
READ CONTROL
LOGIC
EXPANSION LOGIC
OUTPUT REGISTER
RESET LOGIC
Q0-Q17
RCLK
2766 drw 01
SyncFIFO is a trademark and the IDT logo is a registered trademark of Integrated Device Technology, Inc
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES
©2000 Integrated Device Technology, Inc.
MAY 2000
DSC-2766/-
1
For latest information contact IDT's web site at www.idt.com or fax-on-demand at 408-492-8391.
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
VCC
Q17
Q16
GND
Q15
VCC
Q14
Q13
GND
Q12
Q11
VCC
Q10
Q9
GND
Q8
Q7
VCC
Q6
Q5
GND
Q4
Q0
Q1
GND
Q2
Q3
VCC
/
VCC
9 8 7 6 5 4 3 2 68 67 66 65 64 63 62 61
10
60
1
11
59
12
58
13
57
14
56
15
55
16
54
17
53
18
52
19
51
20
50
49
21
48
22
47
23
46
24
45
25
44
26
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43
WCLK
D14
D13
D12
D11
D10
D9
VCC
D8
GND
D7
D6
D5
D4
D3
D2
D1
D0
VCC
GND
D15
D16
D17
GND
RCLK
PIN CONFIGURATIONS
2766 drw 02
Q17
Q16
GND
Q15
VCC
VCC
GND
D16
D17
GND
RCLK
PLCC (J68-1, order code: J)
TOP VIEW
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
Q14
Q13
GND
Q12
Q11
VCC
Q10
Q9
GND
Q8
Q7
Q6
Q5
GND
Q4
VCC
Q0
Q1
GND
Q2
Q3
/
VCC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WCLK
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
PIN 1
2766 drw 03
TQFP (PN64-1, order code: PF)
STQFP (PP64-1, order code: TF)
TOP VIEW
2
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
PIN DESCRIPTION
Symbol
Name
I/O
Description
D0–D17
Data Inputs
I
RS
Reset
I
WCLK
Write Clock
I
WEN
Write Enable
I
RCLK
Read Clock
I
REN
Read Enable
I
OE
Output Enable
I
LD
Load
I
FL
First Load
I
WXI
Write Expansion
I
RXI
Read Expansion
I
FF
Full Flag
O
EF
Empty Flag
O
Programmable
Almost-Empty Flag
O
Programmable
Almost-Full Flag
O
Write Expansion
Out/Half-Full Flag
O
Read Expansion
Out
O
Q0–Q17
Data Outputs
O
VCC
Power
+5V power supply pins.
GND
Ground
Eight ground pins for the PLCC and seven pins for the TQFP/STQFP.
PAE
PAF
WXO/HF
RXO
Data inputs for a 18-bit bus.
When RS is set LOW, internal read and write pointers are set to the first location of the
RAM array, FF and PAF go HIGH, and PAE and EF go LOW. A reset is required before an
initial WRITE after power-up.
When WEN is LOW, data is written into the FIFO on a LOW-to-HIGH transition of WCLK,
if the FIFO is not full.
When WEN is LOW and LD is HIGH, data is written into the FIFO on every LOW-to-HIGH
transition of WCLK. When WEN is HIGH, the FIFO holds the previous data. Data will not be
written into the FIFO if the FF is LOW.
When REN is LOW, data is read from the FIFO on a LOW-to-HIGH transition of RCLK, if the
FIFO is not empty.
When REN is LOW and LD is HIGH, data is read from the FIFO on every LOW-to-HIGH
transition of RCLK. When REN is HIGH, the output register holds the previous data. Data will
not be read from the FIFO if the EF is LOW.
When OE is LOW, the data output bus is active. If OE is HIGH, the output data bus will
be in a high-impedance state.
When LD is LOW, data on the inputs D0–D11 is written to the offset and depth registers
on the LOW-to-HIGH transition of the WCLK, when WEN is LOW. When LD is LOW,
data on the outputs Q0–Q11 is read from the offset and depth registers on the LOW-toHIGH transition of the RCLK, when REN is LOW.
In the single device or width expansion configuration, FL is grounded. In the depth expansion
configuration, FL is grounded on the first device (first load device) and set to HIGH for all other
devices in the Daisy Chain.
In the single device or width expansion configuration, WXI is grounded. In the depth
expansion configuration, WXI is connected to WXO (Write Expansion Out) of the previous device.
In the single device or width expansion configuration, RXI is grounded. In the depth expansion
configuration, RXI is connected to RXO (Read Expansion Out) of the previous device.
When FF is LOW, the FIFO is full and further data writes into the input are inhibited. When
FF is HIGH, the FIFO is not full. FF is synchronized to WCLK.
When EF is LOW, the FIFO is empty and further data reads from the output are inhibited.
When EF is HIGH, the FIFO is not empty. EF is synchronized to RCLK.
When PAE is LOW, the FIFO is almost empty based on the offset programmed into the
FIFO. The default offset at reset is 31 from empty for IDT72205LB, 63 from empty for
IDT72215LB, and 127 from empty for IDT72225LB/72235LB/72245LB.
When PAF is LOW, the FIFO is almost full based on the offset programmed into the FIFO.
The default offset at reset is 31 from full for IDT72205LB, 63 from full for IDT72215LB, and
127 from full for IDT72225LB/72235LB/72245LB.
In the single device or width expansion configuration, the device is more than half full
when HF is LOW. In the depth expansion configuration, a pulse is sent from WXO to
WXI of the next device when the last location in the FIFO is written.
In the depth expansion configuration, a pulse is sent from RXO to RXI of the next device
when the last location in the FIFO is read.
Data outputs for a 18-bit bus.
3
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
ABSOLUTE MAXIMUM RATINGS
Symbol
VTERM
Rating
Terminal Voltage
with respect to GND
Com'l & Ind'l
–0.5 to +7.0
Unit
V
TSTG
Storage
Temperature
–55 to +125
°C
IOUT
DC Output Current
–50 to +50
mA
NOTE:
2766 tbl 02
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions for extended
periods may affect reliability.
Commercial And Industrial Temperature Ranges
RECOMMENDED DC
OPERATING CONDITIONS
Symbol
Parameter
Supply Voltage
VCC
Com'l/Ind'l
Min.
4.5
Typ.
5.0
Max. Unit
5.5
V
GND
VIH
Supply Voltage
Input High Voltage
Com'l/Ind'l
0
2.0
0
—
0
—
V
V
VIL(1)
Input Low Voltage
Com'l/Ind'l
—
—
0.8
V
TA
Operating Temperature
Commercial
0
—
70
°C
TA
Operating Temperature
Industrial
–40
—
85
°C
NOTE:
1. 1.5V undershoots are allowed for 10ns once per cycle.
2766 tbl 03
DC ELECTRICAL CHARACTERISTICS
(Commercial: VCC = 5V ± 10%, TA = 0°C to +70°C; Industrial: VCC = 5V ± 10%, TA = –40°C to +85°C )
Symbol
IDT72205LB
IDT72215LB
IDT72225LB
IDT72235LB
IDT72245LB
Commercial and Industrial(1)
tCLK = 10, 15, 25 ns
Min.
Typ.
Parameter
Max.
Unit
—
1
µA
—
10
µA
ILI(2)
Input Leakage Current (any input)
–1
ILO(3)
Output Leakage Current
–10
VOH
Output Logic “1” Voltage, IOH = –2 mA
2.4
—
—
V
VOL
Output Logic “0” Voltage, IOL = 8 mA
—
—
0.4
V
ICC1(4,5,6)
Active Power Supply Current
—
—
60
mA
ICC2(4,7)
Standby Current
—
—
5
mA
2766 tbl 04
NOTES:
1. Industrial temperature range product for the 15ns and the 25 ns speed grade is available as a standard device.
2. Measurements with 0.4 ≤ VIN ≤ VCC.
3. OE ≥ VIH, 0.4 ≤ VOUT ≤ VCC .
4. Tested with outputs open (IOUT = 0).
5. RCLK and WCLK toggle at 20 MHZ and data inputs switch at 10 MHz.
6. For the 72205/72215/72225 the typical ICC1 = 1.81 + 1.12*fS + 0.02*C L*fS (in mA);
for the 72235/72245 the typical ICC1 = 2.85 + 1.30*fS + 0.02*CL*fS (in mA).
These equations are valid under the following conditions:
VCC = 5V, T A = 25°C, fS = WCLK frequency = RCLK frequency (in MHz, using TTL levels), data switching at fS/2, CL = capacitive load (in pF).
7. All Inputs = VCC - 0.2V or GND + 0.2V, except RCLK and WCLK, which toggle at 20 MHz.
CAPACITANCE (TA = +25°C, f = 1.0MHz)
Symbol
(2)
COUT(1,2)
CIN
Parameter
(1)
AC TEST CONDITIONS
Conditions
Max.
Unit
Input
Capacitance
VIN = 0V
10
pF
Output
Capacitance
VOUT = 0V
10
pF
NOTES:
1. With output deselected, (OE ≥ VIH).
2. Characterized values, not currently tested.
Input Pulse Levels
Input Rise/Fall Times
Input Timing Reference Levels
Output Reference Levels
Output Load
GND to 3.0V
3ns
1.5V
1.5V
See Figure 1
2766 tbl 06
2766 tbl 05
4
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
AC ELECTRICAL CHARACTERISTICS
(Commercial: VCC = 5V ± 10%, TA = 0°C to +70°C; Industrial: VCC = 5V ± 10%, TA = –40°C to +85°C)
Symbol
Commercial
72205LB10
72215LB10
72225LB10
72235LB10
72245LB10
Min. Max.
Parameter
Com'l & Ind'l(1)
72205LB15
72205LB25
72215LB15
72215LB25
72225LB15
72225LB25
72235LB15
72235LB25
72245LB15
72245LB25
Min. Max. Min. Max.
Unit
fS
Clock Cycle Frequency
—
100
—
66.7
—
40
MHz
tA
Data Access Time
2
6.5
2
10
2
15
ns
tCLK
Clock Cycle Time
10
—
15
—
25
—
ns
tCLKH
Clock HIGH Time
4.5
—
6
—
10
—
ns
tCLKL
Clock LOW Time
4.5
—
6
—
10
—
ns
tDS
Data Set-up Time
3
—
4
—
6
—
ns
tDH
Data Hold Time
0
—
1
—
1
—
ns
tENS
Enable Set-up Time
3
—
4
—
6
—
ns
tENH
Enable Hold Time
0
—
1
—
1
—
ns
Width(2)
tRS
Reset Pulse
tRSS
Reset Set-up Time
tRSR
Reset Recovery Time
tRSF
Reset to Flag and Output Time
0
3
Low-Z(3)
10
—
15
—
25
—
ns
8
—
10
—
15
—
ns
8
—
10
—
15
—
ns
—
15
—
20
—
25
ns
—
0
—
0
—
ns
6
3
8
3
12
ns
tOLZ
Output Enable to Output in
tOE
Output Enable to Output Valid
tOHZ
Output Enable to Output in High-Z(3)
3
6
3
8
3
12
ns
tWFF
Write Clock to Full Flag
—
6.5
—
10
—
15
ns
tREF
Read Clock to Empty Flag
—
6.5
—
10
—
15
ns
tPAF
Clock to Programmable Almost-Full
Flag
—
17
—
24
—
26
ns
tPAE
Clock to Programmable Almost-Empty
Flag
—
17
—
24
—
26
ns
tHF
Clock to Half-Full Flag
—
17
—
24
—
26
ns
tXO
Clock to Expansion Out
—
6.5
—
10
—
15
ns
tXI
Expansion In Pulse Width
3
—
6.5
—
10
—
ns
tXIS
Expansion In Set-Up Time
3.5
—
5
—
10
—
ns
tSKEW1
Skew time between Read Clock &
Write Clock for Full Flag
5
—
6
—
10
—
ns
tSKEW2
Skew time between Read Clock &
Write Clock for Empty Flag
5
—
6
—
10
—
ns
NOTES:
1. Industrial temperature range is available as standard product for the 15ns
and the 25ns speed grade.
2. Pulse widths less than minimum values are not allowed.
3. Values guaranteed by design, not currently tested.
2766 tbl 07
5V
1.1K
D.U.T.
680Ω
30pF*
2766 drw 04
Figure 1. Output Load
* Includes jig and scope capacitances.
5
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
SIGNAL DESCRIPTIONS:
INPUTS:
DATA IN (D0 - D17)
Data inputs for 18-bit wide data.
CONTROLS:
RESET (RS)
Reset is accomplished whenever the Reset (RS) input is
taken to a LOW state. During reset, both internal read and
write pointers are set to the first location. A reset is required
after power-up before a write operation can take place. The
Full Flag (FF), Half-Full Flag (HF) and Programmable AlmostFull Flag (PAF) will be reset to HIGH after tRSF. The Empty
Flag (EF ) and Programmable Almost-Empty Flag (PAE) will be
reset to LOW after tRSF. During reset, the output register is
initialized to all zeros and the offset registers are initialized to
their default values.
WRITE CLOCK (WCLK)
A write cycle is initiated on the LOW-to-HIGH transition of the
write clock (WCLK). Data set-up and hold times must be met with
respect to the LOW-to-HIGH transition of the write clock (WCLK).
The write and read clocks can be asynchronous or coincident.
WRITE ENABLE (WEN )
When the WEN input is LOW and LD input is HIGH, data
may be loaded into the FIFO RAM array on the rising edge of
every WCLK cycle if the device is not full. Data is stored in the
RAM array sequentially and independently of any ongoing
read operation.
When WEN is HIGH, no new data is written in the RAM
array on each WCLK cycle.
To prevent data overflow, FF will go LOW, inhibiting further
write operations. Upon the completion of a valid read cycle, FF
will go HIGH allowing a write to occur. The FF flag is updated on
the rising edge of WCLK. WEN is ignored when the FIFO is full.
READ CLOCK (RCLK)
Data can be read on the outputs on the LOW-to-HIGH transition
of the read clock (RCLK), when Output Enable (OE) is set LOW.
The write and read clocks can be asynchronous or coincident.
READ ENABLE (REN)
When Read Enable is LOW and LD input is HIGH, data is
loaded from the RAM array into the output register on the
rising edge of every RCLK cycle if the device is not empty.
When the REN input is HIGH, the output register holds the
previous data and no new data is loaded into the output
register. The data outputs Q0-Qn maintain the previous data
value.
Every word accessed at Qn, including the first word written
to an empty FIFO, must be requested using REN. When the
last word has been read from the FIFO, the Empty Flag (EF)
will go LOW, inhibiting further read operations. REN is ignored
when the FIFO is empty. Once a write is performed, EF will go
HIGH allowing a read to occur. The EF flag is updated on the
rising edge of RCLK.
Commercial And Industrial Temperature Ranges
OUTPUT ENABLE (OE)
When Output Enable (OE) is enabled (LOW), the parallel
output buffers receive data from the output register. When OE
is disabled (HIGH), the Q output data bus is in a highimpedance state.
LOAD (LD)
The IDT72205LB/72215LB/72225LB/72235LB/72245LB
devices contain two 12-bit offset registers with data on the
inputs, or read on the outputs. When the Load (LD) pin is set
LOW and WEN is set LOW, data on the inputs D0-D11 is
written into the Empty offset register on the first LOW-to-HIGH
transition of the write clock (WCLK). When the LD pin and
(WEN) are held LOW then data is written into the Full offset
register on the second LOW-to-HIGH transition of the write
clock (WCLK). The third transition of the write clock (WCLK)
again writes to the Empty offset register.
However, writing all offset registers does not have to occur
at one time. One or two offset registers can be written and then
by bringing the LD pin HIGH, the FIFO is returned to normal
read/write operation. When the LD pin is set LOW, and WEN
is LOW, the next offset register in sequence is written.
LD
WEN
0
0
WCLK
Selection
Writing to offset registers:
Empty Offset
Full Offset
0
1
No Operation
1
0
Write Into FIFO
1
1
No Operation
NOTE:
2766 tbl 08
1. The same selection sequence applies to reading from the registers. REN
is enabled and read is performed on the LOW-to-HIGH transition of
RCLK.
Figure 2. Write Offset Register
17
0
11
EMPTY OFFSET REGISTER
DEFAULT VALUE
001FH (72205) 003FH (72215):
007FH (72225/72235/72245)
17
11
0
FULL OFFSET REGISTER
DEFAULT VALUE
001FH (72205) 003FH (72215):
007FH (72225/72235/72245)
2766 drw 05
NOTE:
1. Any bits of the offset register not being programmed should be set to zero.
Figure 3. Offset Register Location and Default Values
6
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
When the LD pin is LOW and WEN is HIGH, the WCLK input
is disabled; then a signal at this input can neither increment the
write offset register pointer, nor execute a write.
The contents of the offset registers can be read on the
output lines when the LD pin is set LOW and REN is set LOW;
then, data can be read on the LOW-to-HIGH transition of the
read clock (RCLK). The act of reading the control registers
employs a dedicated read offset register pointer. (The read
and write pointers operate independently).
A read and a write should not be performed simultaneously
to the offset registers.
FIRST LOAD (FL)
FL is grounded to indicate operation in the Single Device or
Width Expansion mode. In the Depth Expansion configuration,
FL is grounded to indicate it is the first device loaded and is set
to HIGH for all other devices in the Daisy Chain. (See Operating
Configurations for further details.)
WRITE EXPANSION INPUT (WXI)
This is a dual purpose pin. WXI is grounded to indicate
operation in the Single Device or Width Expansion mode. WXI
is connected to Write Expansion Out (WXO) of the previous
device in the Daisy Chain Depth Expansion mode.
READ EXPANSION INPUT (RXI)
This is a dual purpose pin. RXI is grounded to indicate
operation in the Single Device or Width Expansion mode. RXI
is connected to Read Expansion Out (RXO) of the previous
device in the Daisy Chain Depth Expansion mode.
OUTPUTS:
FULL FLAG (FF )
When the FIFO is full, FF will go LOW, inhibiting further
write operations. When FF is HIGH, the FIFO is not full. If no
reads are performed after a reset, FF will go LOW after D
writes to the FIFO. D = 256 writes for the IDT72205LB, 512 for
the IDT72215LB, 1,024 for the IDT72225LB, 2,048 for the
IDT72235LB and 4,096 for the IDT72245LB.
The FF is updated on the LOW-to-HIGH transition of the
write clock (WCLK).
EMPTY FLAG (EF)
When the FIFO is empty, EF will go LOW, inhibiting further
read operations. When EF is HIGH, the FIFO is not empty.
The EF is updated on the LOW-to-HIGH transition of the
read clock (RCLK).
PROGRAMMABLE ALMOST-FULL FLAG (PAF)
The Programmable Almost-Full Flag (PAF) will go LOW
when FIFO reaches the Almost-Full condition. If no reads are
performed after Reset (RS), the PAF will go LOW after (256-m)
writes for the IDT72205LB, (512-m) writes for the IDT72215LB,
(1,024-m) writes for the IDT72225LB, (2,048–m) writes for the
IDT72235LB and (4,096–m) writes for the IDT72245LB. The
offset “m” is defined in the FULL offset register.
If there is no Full offset specified, the PAF will be LOW when
the device is 31 away from completely full for IDT72205LB, 63
away from completely full for IDT72215LB, and 127 away from
completely full for IDT72225LB/72235LB/72245LB.
The PAF is asserted LOW on the LOW-to-HIGH transition
of the write clock (WCLK). PAF is reset to HIGH on the LOWto-HIGH transition of the read clock (RCLK). Thus PAF is
asynchronous.
PROGRAMMABLE ALMOST-EMPTY FLAG (PAE)
The Programmable Almost-Empty Flag (PAE) will go LOW
when the read pointer is “n+1” locations less than the write
pointer. The offset “n” is defined in the EMPTY offset register.
If there is no Empty offset specified, the Programmable
Almost-Empty Flag (PAE) will be LOW when the device is 31
away from completely empty for IDT72205LB, 63 away from
completely empty for IDT72215LB, and 127 away from completely empty for IDT72225LB/72235LB/72245LB.
The PAE is asserted LOW on the LOW-to-HIGH transition
of the read clock (RCLK). PAE is reset to HIGH on the LOWto-HIGH transition of the write clock (WCLK). Thus PAE is
asynchronous.
WRITE EXPANSION OUT/HALF-FULL FLAG (WXO/HF)
This is a dual-purpose output. In the Single Device and
Width Expansion mode, when Write Expansion In (WXI) and
Read Expansion In (RXI) are grounded, this output acts as an
indication of a half-full memory.
TABLE I — STATUS FLAGS
72205
72215
0
0
(1)
1 to n
(n + 1) to 128
1 to
Number of Words in FIFO Memory
72225
72235
0
n(1)
(n + 1) to 256
1 to
72245
0
n(1)
(n + 1) to 512
1 to
0
n(1)
(n + 1) to 1,024
1 to
H
n(1)
(n + 1) to 2,048
129 to (256-(m+1)) 257 to (512-(m+1)) 513 to (1,024-(m+1)) 1,025 to (2,048-(m+1)) 2,049 to (4,096-(m+1))
(2)
(256-m)
256
to 255
(512-m)(2)
512
to 511
(1,024-m)(2)
to 1,023
1,024
(2,048-m)(2)
to 2,047
(4,096-m)(2)
2,048
NOTES:
1. n = Empty Offset (Default Values : IDT72205 n=31, IDT72215 n = 63, IDT72225/72235/72245 n = 127)
2. m = Full Offset (Default Values : IDT72205 n=31, IDT72215 n = 63, IDT72225/72235/72245 n = 127)
FF PAF HF PAE EF
to 4,095
4,096
H
H
L
L
H
H
H
L
H
H
H
H
H
H
H
H
L
H
H
H
L
L
H
H
L
L
L
H
H
2766 tbl 09
7
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
After half of the memory is filled, and at the LOW-to-HIGH
transition of the next write cycle, the Half-Full Flag goes LOW
and will remain set until the difference between the write
pointer and read pointer is less than or equal to one half of the
total memory of the device. The Half-Full Flag ( HF) is then
reset to HIGH by the LOW-to-HIGH transition of the read clock
(RCLK). The HF is asynchronous.
In the Daisy Chain Depth Expansion mode, WXI is connected
to WXO of the previous device. This output acts as a signal to the
next device in the Daisy Chain by providing a pulse when the
previous device writes to the last location of memory.
Commercial And Industrial Temperature Ranges
READ EXPANSION OUT (RXO)
In the Daisy Chain Depth Expansion configuration, Read
Expansion In (RXI ) is connected to Read Expansion Out (RXO)
of the previous device. This output acts as a signal to the next
device in the Daisy Chain by providing a pulse when the
previous device reads from the last location of memory.
DATA OUTPUTS (Q0-Q17)
Q0-Q17 are data outputs for 18-bit wide data.
t RS
tRSS
,
t RSR
,
t RSF
,
t RSF
,
,
t RSF
= 1(1)
Q0 - Q17
=0
2766 drw 06
NOTES:
1. After reset, the outputs will be LOW if OE = 0 and tri-state if OE = 1.
2. The clocks (RCLK, WCLK) can be free-running during reset.
Figure 4. Reset Timing(2)
8
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
t CLK
t CLKH
t CLKL
WCLK
t DH
t DS
D0 - D17
DATA IN VALID
t ENH
t ENS
NO OPERATION
t WFF
t WFF
t SKEW1(1)
RCLK
2766 drw 07
NOTES:
1. tSKEW1 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that FF will go HIGH during the current clock cycle. If the
time between the rising edge of RCLK and the rising edge of WCLK is less than tSKEW1, then FF may not change state until the next WCLK edge.
Figure 5. Write Cycle Timing
t CLK
t CLKH
t CLKL
RCLK
t ENS
t ENH
NO OPERATION
t REF
t REF
tA
Q0 - Q17
VALID DATA
t OLZ
t OHZ
t OE
t SKEW2
(1)
WCLK
2766 drw 08
NOTE:
1. tSKEW2 is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that EF will go HIGH during the current clock cycle. If the
time between the rising edge of WCLK and the rising edge of RCLK is less than tSKEW2, then EF may not change state until the next RCLK edge.
Figure 6. Read Cycle Timing
9
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
WCLK
t DS
D0 (first valid write)
D0 - D17
D1
D2
D3
tA
tA
D4
t ENS
t FRL(1)
t SKEW2
RCLK
t REF
tENS
Q0 - Q17
D0
t OLZ
D1
t OE
NOTES:
1. When tSKEW2 minimum specification, tFRL (maximum) = tCLK + tSKEW2. When tSKEW2 < minimum specification, t FRL (maximum) = either
2*tCLK + tSKEW2 or t CLK + tSKEW2. The Latency Timing applies only at the Empty Boundary (EF = LOW).
2. The first word is available the cycle after EF goes HIGH, always.
2766 drw 09
Figure 7. First Data Word Latency after Reset with Simultaneous Read and Write
NO WRITE
WCLK
NO WRITE
(1)
(1)
t SKEW1
t SKEW1
t DS
D0 - D17
t DS
DATA
WRITE
DATA WRITE
t WFF
t WFF
t WFF
RCLK
t ENS
t ENH
t ENS
t ENH
LOW
tA
Q0 - Q17
DATA IN OUTPUT REGISTER
tA
DATA READ
NEXT DATA READ
2766 drw 10
NOTE:
1. tSKEW1 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that FF will go HIGH during the current clock cycle. If the
time between the rising edge of RCLK and the rising edge of WCLK is less than tSKEW1, then FF may not change state until the next WCLK edge.
Figure 8. Full Flag Timing
10
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
WCLK
tDS
tDS
DATA WRITE 1
D0 - D17
tENS
DATA WRITE 2
tENS
tENH
tFRL
tSKEW2
tENH
(1)
tFRL
(1)
tSKEW2
RCLK
tREF
tREF
tREF
LOW
tA
Q0 - Q17
DATA READ
DATA IN OUTPUT REGISTER
2766 drw 11
NOTE:
1. When tSKEW2 minimum specification, tFRL (maximum) = tCLK + tSKEW2. When tSKEW2 < minimum specification, tFRL (maximum) = either 2 * tCLK + t SKEW2,
or t CLK + tSKEW2. The Latency Timing apply only at the Empty Boundary (EF = LOW).
Figure 9. Empty Flag Timing
tCLK
tCLKH
tCLKL
WCLK
tENS
tENH
LD
tENS
WEN
tDS
tDH
PAE OFFSET
D0–D15
PAE OFFSET
D0–D11
PAF OFFSET
2766 drw 12
Figure 10. Write Programmable Registers
tCLKH
tCLK
tCLKL
RCLK
tENS
tENH
tENS
tA
Q0–Q15
UNKNOWN
PAE OFFSET
PAE OFFSET
PAF OFFSET
2766 drw 13
Figure 11. Read Programmable Registers
11
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
tCLKH
Commercial And Industrial Temperature Ranges
tCLKL
WCLK
tENS
tENH
tPAE
n + 1 words in FIFO
n words in FIFO
tPAE
RCLK
tENS
NOTE:
1. n = PAE offset. Number of data words written into FIFO already = n.
2766 drw 14
Figure 12. Programmable Almost-Empty Flag Timing
tCLKH
tCLKL
WCLK
(1)
tENS
tENH
tPAF
D – m + 1 words in FIFO
D – m words
(2)
in FIFO memory
memory (1)
D – m + 1 words
in FIFO memory (1)
tPAF
RCLK
tENS
2766 drw 15
NOTES:
1. m = PAF offset. D = maximum FIFO Depth. Number of data words written into FIFO memory = 256 - m + 1 for the IDT72205, 512 -m + 1 for the IDT72215,
1,024 - m + 1 for the IDT72225, 2,048 - m + 1 for the IDT72235 and 4,096 - m + 1 for the IDT72245.
2. 256 - m words in IDT72205, 512 - m words in IDT72215, 1,024 - m words in IDT72225, 2,048 - m words in IDT72235 and 4,096 - m words in IDT72245.
Figure 13. Programmable Almost-Full Flag Timing
tCLKH
tCLKL
WCLK
tENS
tENH
tHF
D/2 + 1 words in
FIFO memory(2)
(1)
D/2 words in FIFO memory
D/2 words in
FIFO memory(1)
tHF
RCLK
tENS
2766 drw 16
NOTE:
1. D = maximum FIFO Depth = 256 words for the IDT72205, 512 words for the IDT72215, 1,024 words for the IDT72225, 2,048 words for the IDT72235 and
4,096 words for the IDT72245.
Figure 14. Half-Full Flag Timing
12
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
t CLKH
WCLK
Note 1
t XO
t XO
t ENS
2766 drw 17
NOTE:
1. Write to Last Physical Location.
Figure 15. Write Expansion Out Timing
t CLKH
RCLK
Note 1
t XO
t XO
t ENS
2766 drw 18
NOTE:
1. Read from Last Physical Location.
Figure 16. Read Expansion Out Timing
t XI
t XIS
WCLK
2766 drw 19
Figure 17. Write Expansion In Timing
t XI
t XIS
RCLK
2766 drw 20
Figure 18. Read Expansion In Timing
13
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
OPERATING CONFIGURATIONS
SINGLE DEVICE CONFIGURATION
A single IDT72205LB/72215LB/72225LB/72235LB/72245LB
may be used when the application requirements are for 256/
Commercial And Industrial Temperature Ranges
512/1,024/2,048/4,096 words or less. These FIFOs are in a
single Device Configuration when the First Load (FL), Write
Expansion In (WXI) and Read Expansion In (RXI) control inputs
are grounded (Figure 19).
RESET (
)
WRITE CLOCK (WCLK)
READ CLOCK (RCLK)
WRITE ENABLE (
READ ENABLE (
LOAD (
)
)
OUTPUT ENABLE (
IDT
72205LB
72215LB
72225LB
72235LB
72245LB
DATA IN (D0 - D17)
FULL FLAG (
)
)
PROGRAMMABLE (
HALF-FULL FLAG (
)
DATA OUT (Q0 - Q17)
EMPTY FLAG (
)
)
PROGRAMMABLE (
)
)
FIRST LOAD (
2766 drw 21
)
READ EXPANSION IN (
WRITE EXPANSION IN (
)
)
Figure 19. Block Diagram of Single 256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18, 4,096 x 18 Synchronous FIFO
WIDTH EXPANSION CONFIGURATION
Word width may be increased simply by connecting together
the control signals of multiple devices. Status flags can be
detected from any one device. The exceptions are the Empty
Flag and Full Flag. Because of variations in skew between
RCLK and WCLK, it is possible for flag assertion and deassertion
to vary by one cycle between FIFOs. To avoid problems the
RESET (
DATA IN (D) 36
user must create composite flags by ANDing the Empty Flags
of every FIFO, and separately ANDing all Full Flags. Figure 20
demonstrates a 36-word width by using two IDT72205B/72215B/
72225B/72235B/72245Bs. Any word width can be attained by
adding additional IDT72205B/72215B/72225B/72235B/
72245Bs. Please see the Application Note AN-83.
)
18
RESET (
)
18
READ CLOCK (RCLK)
WRITE CLOCK (WCLK)
WRITE ENABLE (
LOAD (
)
)
PROGRAMMABLE (
HALF FULL FLAG (
FULL FLAG (
)
)
)
OUTPUT ENABLE (
)
PROGRAMMABLE (
72205LB
72215LB
72225LB
72235LB
72245LB
72205LB
72215LB
72225LB
72235LB
72245LB
READ ENABLE (
EMPTY FLAG (
18
)
18
FIRST LOAD ( )
WRITE EXPANSION IN (
READ EXPANSION IN (
)
)
)
DATA OUT (Q)
)
36
2766 drw 22
NOTE:
1. Do not connect any output control signals directly together.
Figure 20. Block Diagram of 256 x 36, 512 x 36, 1,024 x 36, 2,048 x 36, 4,096 x 36
Synchronous FIFO Memory Used in a Width Expansion Configuration
14
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18-BIT, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
DEPTH EXPANSION CONFIGURATION
(WITH PROGRAMMABLE FLAGS)
These devices can easily be adapted to applications requiring more than 256/512/1,024/2,048/4,096 words of buffering.
Figure 21 shows Depth Expansion using three IDT72205LB/
72215LB/72225LB/72235LB/72245LBs. Maximum depth is
limited only by signal loading. Follow these steps:
1. The first device must be designated by grounding the
First Load (FL) control input.
2. All other devices must have FL in the HIGH state.
3. The Write Expansion Out (WXO) pin of each device
must be tied to the Write Expansion In (WXI) pin of
the next device. See Figure 21.
4. The Read Expansion Out (RXO) pin of each device
must be tied to the Read Expansion In (RXI) pin of
the next device. See Figure 21.
5. All Load (LD) pins are tied together.
6. The Half-Full Flag (HF) is not available in this Depth
Expansion Configuration.
7. EF, FF, PAE, and PAF are created with composite
flags by ORing together every respective flags for
monitoring. The composite PAE and PAF flags are not
precise.
WCLK
RCLK
Dn
Vcc
IDT
72205LB
72215LB
72225LB
72235LB
72245LB
Qn
WCLK
RCLK
Dn
DATA IN
Vcc
WRITE CLOCK
IDT
72205LB
72215LB
72225LB
72235LB
72245LB
WCLK
Qn
RCLK
WRITE ENABLE
DATA OUT
READ CLOCK
READ ENABLE
RESET
OUTPUT ENABLE
Dn
LOAD
FIRST LOAD (
IDT
72205LB
72215LB
72225LB
72235LB
72245LB
Qn
)
2766 drw 23
Figure 21. Block Diagram of 768 x 18, 1,536 x 18, 3,072 x 18, 6,144 x 18, 12,288 x 18 Synchronous
FIFO Memory With Programmable Flags used in Depth Expansion Configuration
15
IDT72205LB/72215LB/72225LB/72235LB/72245LB CMOS SyncFIFO™
256 x 18, 512 x 18, 1,024 x 18, 2,048 x 18 and 4,096 x 18
Commercial And Industrial Temperature Ranges
ORDERING INFORMATION
IDT
XXXXX
Device Type
X
Power
XX
Speed
X
Package
X
Process /
Temperature
Range
BLANK
I (1)
Commercial (0°C to +70°C)
Industrial (–40°C to +85°C)
J
PF
TF
Plastic Leaded Chip Carrier (PLCC, J68-1)
Thin Plastic Quad Flatpack (TQFP, PN64-1)
Slim Thin Plastic Quad Flatpack (STQFP, PP64-1)
10
15
25
Commercial Only
Commercial & Industrial
Commercial & Industrial
LB
Low Power
72205
72215
72225
72235
72245
256 x 18 Synchronous FIFO
512 x 18 Synchronous FIFO
1,024 x 18 Synchronous FIFO
2,048 x 18 Synchronous FIFO
4,096 x 18 Synchronous FIFO
Clock Cycle Time (tCLK)
Speed in Nanoseconds
2766 drw 24
NOTE:
1. Industrial temperature range is available as standard product for the 15ns and the 25 ns speed grade.
16
Similar pages