XP Power JCP4012T0312 Dc-dc power supply Datasheet

DC-DC
40 Watts
xppower.com
JCP Series
•
2:1 Input Range
•
Single, Dual & Triple Outputs
•
-40 °C to +100 °C Operating Temperature
•
High Efficiency up to 92%
•
Six-sided Metal Case
•
Fixed 350 kHz Switching Frequency
•
Continuous Short Circuit Protection
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
General
• 12 VDC (9-18 VDC)
24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input
Turn off <67% nominal input
Efficiency
Isolation Voltage
Switching Frequency
MTBF
• See table
• 1500 VDC Input to Output
1500 VDC Input to Case
Output return connected to case
• 350 kHz typical
• >600 kHrs to MIL-STD-217F
Environmental
Output
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
•
•
•
•
Load Regulation
•
Setpoint Accuracy
Voltage Balance
Ripple & Noise
•
•
•
Transient Response
•
See table
±10%
See table
±0.5% max for single & dual outputs,
±1.0% max for V1 of triple outputs,
±5.0% for V2 & V3
±0.5% max single & dual outputs,
±2.0% max for V1 of triple outputs,
±5.0% for V2 & V3
±1.5% max
±2.0% max
2.5, 3.3 & 5.0 V models 50 mV pk-pk max
12.0 & 15.0 V models 75 mV pk-pk max
(20 MHz bandwidth)
5% max deviation, recovery to within
1% in 300 µs for a 25% load change
±0.02%/°C
Temperature
•
Coefficient
Overvoltage Protection • 2.5 V models 3.6 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection • 110-140%
Short Circuit Protection • Continuous, trip & restart (Hiccup mode)
Remote On/Off
• ON >3.5 VDC or open circuit
OFF <1.8 VDC
Thermal Protection
• Shuts down when case temperature
measures +110 °C typical
Remote Sense
• Compensates for up to 10% voltage drop
single output models only
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +60 °C to 0% load at +100 °C
Case Temperature
Storage Temperature
Cooling
Operating Humidity
Shock
Vibration
•
•
•
•
•
+100 °C max
-55 °C to +125 °C
Convection-cooled
Up to 90%, non-condensing
30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
• EN55022 Level A conducted & radiated
with external components - contact
technical sales
• EN61000-4-2, Level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-6, 3 V rms Perf Criteria A
Input
Voltage
Output
Voltage
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
9-18 V
18-36 V
36-75 V
Output Current
Max
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
Input Current(2)
No Load
Full Load
200 mA
2422 mA
200 mA
3161 mA
200 mA
3745 mA
200 mA
3703 mA
200 mA
3702 mA
100 mA
4186 mA
100 mA
4070 mA
200 mA
2917 mA
200 mA
2857 mA
200 mA
3837 mA
200 mA
3779 mA
100 mA
1184 mA
100 mA
1545 mA
110 mA
1831 mA
100 mA
1811 mA
100 mA
1810 mA
100 mA
2069 mA
100 mA
2011 mA
100 mA
1441 mA
100 mA
1412 mA
100 mA
1897 mA
100 mA
1868 mA
50 mA
599 mA
50 mA
781 mA
60 mA
926 mA
60 mA
916 mA
60 mA
906 mA
50 mA
1034 mA
50 mA
1006 mA
50 mA
712 mA
50 mA
698 mA
50 mA
938 mA
50 mA
923 mA
Min
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Efficiency
86%
87%
89%
90%
90%
86%
86%
84%
84%
86%
86%
88%
89%
91%
92%
92%
87%
87%
85%
85%
87%
87%
87%
88%
90%
91%
92%
87%
87%
86%
86%
88%
88%
Model
Number(1)
JCP4012S2V5
JCP4012S3V3
JCP4012S05
JCP4012S12
JCP4012S15
JCP4012D12
JCP4012D15
JCP4012T0312
JCP4012T0315
JCP4012T0512
JCP4012T0515
JCP4024S2V5
JCP4024S3V3
JCP4024S05
JCP4024S12
JCP4024S15
JCP4024D12
JCP4024D15
JCP4024T0312
JCP4024T0315
JCP4024T0512
JCP4024T0515
JCP4048S2V5
JCP4048S3V3
JCP4048S05
JCP4048S12
JCP4048S15
JCP4048D12
JCP4048D15
JCP4048T0312
JCP4048T0315
JCP4048T0512
JCP4048T0515
Notes
1. Add suffix ‘-N’ to model number for negative logic Remote On/Off.
2. Input current measured at nominal input voltage.
Mechanical Details
2.0 (50.8)
All dimensions are in inches (mm)
Weight: 65 g (0.14 lbs)
0.20 (5.1)
3
2
1
1.80 (45.7)
PIN CONNECTIONS
Single
Dual
Triple
+V Input
+V Input
+V Input
-V Input
-V Input
-V Input
On/Off
On/Off
On/Off
NC
NC
+Aux. Output
-Sense
+V Output 1
Rtn
+Sense
Rtn
-Aux. Output
+Vout
Rtn
+V Output 1
Rtn
-V Output 2
Rtn
Trim
Trim
NC
BOTTOM
VIEW
9
8
7
0.40 (10.2)
6
5
DIA. 0.04±0.002 (1.0±0.05)
0.40 (10.2)
2.0 (50.8)
Pin
1
2
3
4
5
6
7
8
9
1.15 (29.2)
4
0.10 (2.5)
0.22 (5.6)
0.30 (7.6)
0.60 (15.2)
0.80 (20.3)
0.20 (5.1)
0.50 (12.7)
Application Notes
Derating Curve
100
-2.5%/°C
Load (%)
80
Remote On/Off Control
Remote Sense
Standard ROF logic is positive.
Output On >3.5 VDC or open circuit
Output Off <1.8 VDC
If remote sense is not being used:
+Sense should be connected to +Vout
-Sense should be connected to -Vout.
Optional ROF logic is negative (‘-N’ version).
Output On <1.8 VDC
Output Off >3.5 VDC or open circuit
60
40
20
0
-40 -20
0
10
20
30
40
50
60
70
80
90
100
Ambient Temperature (°C)
Natural convection, 20 ft/min (0.1 m/s)
Maximum case temperature 100 °C
17-Apr-07
DC-DC
JCP
Models and Ratings
Similar pages