AC-DC 130 Watts xppower.com JPP130 Series • High Power Density • Small Footprint • Up to Five DC Outputs • Wide Adjustment on Two Outputs • Short Circuit Protection with Auto Recovery • Power Fail Signal • Active Power Factor Correction Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor General • • • • • 90-264 VAC 47-63 Hz 2.10 A at 115 VAC, 1.10 A at 230 VAC 35 A at 115 VAC, 70 A at 230 VAC 0.98 typical Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Transient Response • • • • • • • • • See table User adjustable (see note 3) 2% except V2: 3% See note 4 2 s max 12 ms max 15 ms min ±0.5% max 4% max. deviation, 500 µs recovery time for a 25% load change Ripple & Noise • 65 mV for V1, 1% pk-pk on all other outputs, 20 MHz BW Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal Temperature • 0.04% / ºC Coefficient Remote Sense • On 3.3 V output only: Compensates for up to 0.5 V drop Efficiency Isolation Power Density Signals MTBF • 75% typical • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 7.2 W/In3 • PFD = TTL Level (see note 5) • 200 kHrs per MIL-STD-217F Environmental Operating Temperature • -10 ºC to +60 ºC, derate from 100% load at +40 ºC to 50% load at +60 ºC Cooling • 10 CFM Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 ºC to + 85 ºC Shock • 20 G on 3 axis, 3 times each Vibration • 10-55 Hz, 0.15 at 1 octave/min for 30 mins on each 3 axis EMC & Safety Emissions Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022 FCC part 15 and VCCI level B conducted and level A radiated • EN61000-3-2 • EN61000-3-3 • EN61000-4-4, level 2 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN61000-4-6, 3 V Perf Criteria A • EN61000-4-8, 1 A/m Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • UL60950, CSA C22.2 No. 60950, EN60950, CE Mark LVD Output V1(3, 4) +5.1 V/12.0 A +5.1 V/12.0 A +5.1 V/12.0 A +5.1 V/12.0 A Output V2 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 V/6.0 V/4.8 V/3.0 Output V3(3) A A A A A A A A A A A A A A A A A A A A A A A A Output V4(3) Output V5(2, 3) Model Number JPP130PD02 JPP130PD03 JPP130PD04 JPP130PT01 JPP130PT02 JPP130PT03 JPP130PT04 JPP130PT05 JPP130PT06 JPP130PT07 JPP130PT08 JPP130PT09 JPP130PQ01 JPP130PQ02 JPP130PQ03 JPP130PQ04 JPP130PQ05 JPP130PQ06 JPP130PQ07 JPP130PQ08 JPP130PQ09 JPP130PM01 JPP130PM02 JPP130PM03 3.3 V/12.0 A 3.3 V/12.0 A 3.3 V/12.0 A +5.0 to 24.0 V/1.0 A +5.0 to 24.0 V/1.0 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A -5.0 to -24.0 V/1.0 A -5.0 to -24.0 V/1.0 A +5.0 to 24.0 V/1.0 A +5.0 to 24.0 V/1.0 A +5.0 to 24.0 V/1.0 A +5.0 +5.0 +5.0 +5.0 +5.0 +5.0 to to to to to to 24.0 24.0 24.0 24.0 24.0 24.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 A A A A A A -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 to to to to to to to to to -24.0 -24.0 -24.0 -24.0 -24.0 -24.0 -24.0 -24.0 -24.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 V/1.0 A A A A A A A A A 3.3 3.3 3.3 3.3 3.3 3.3 V/12.0 V/12.0 V/12.0 V/12.0 V/12.0 V/12.0 A A A A A A 3.3 V/12.0 A 3.3 V/12.0 A 3.3 V/12.0 A Notes 1. Minimum 10 CFM required for 130 W operation. 2. V1 and V5 combined output power not to exceed 65 W; V2, V3 and V4 combined output power not to exceed 65 W; V3 and V4 combined output power not to exceed 30 W. 3. Adjustable range: V1 and V5 are adjustable ±10%, V3 and V4 can be trimmed 5-24 VDC and are factory-set to 12 VDC nominal. Accessible trim pots are assigned as VR1 for V1, VR2 for V5, VR3 for V3, VR4 for V4 and V2 is fixed. VR3 and VR4 trim pots are SMD types are located underneath PCB. 4. Minimum load of 0.8 A is required on V1 to regulate V5 where fitted. 5. PFD = TTL low gives warning of at least 10 ms before V1 output drops below 95% of nominal. This signal also provides a minimum of 100 ms delay after V1 is within regulation. Mechanical Details All dimensions are in inches (mm), tolerance: ±0.02 (±0.5) max Weight: 0.71 lbs (320 g) 0.225 (5.72) 0.16 (4.0) Dia Mounting Hole (4 PLS) 6 DIRECTION OF AIR FLOW P3 N L P1 P4 1 4 2.55 (64.8) 3.00 (76.2) P2 1 2 1 PIN CONNECTIONS Pin P1 P2 P3 1 Live V1 -Sense (V5) P4(1) V5 2 Neutral Com +Sense (V5) Com 3 - Com PFD signal - 4 - V3 or N/C Com - 5 - V4 or N/C - - 6 - V2 or N/C - - Note: 1. P4 only applies to models which have an Output V5 in the Models and Rating table. Derating Curve 4.55 (115.6) 5.00 (127.0) 130 1.04 (26.4) VR2 VR1 0.10 (2.54) P2 & P4 Connectors: Can accept 18-12 AWG electric wires. P1 Mating Connector: Molex 09-50-3031 and 2878 series crimp terminals or equivalent. P3 Mating Connector: Molex 22-01-1043 and 40445 series crimp terminals or equivalent. Output Power (W) 1.20 (30.48) 10 CFM Forced-air Cooling 90 65 W 5 CFM Forced-air Cooling 45 W Convection Cooling 10 W 20 0.06 (1.60) 0 -10 0 10 20 30 40 50 Ambient Temperature (˚C) 60 04/04/05 AC-DC JPP130 Models and Ratings