ETC2 JQX-13F/A0301Z5 Miniature intermediate power relay Datasheet

JQX-13F
MINIATURE INTERMEDIATE POWER RELAY
Features
File No.:E133481
* 15A switching capabilities
* 1&2 pole configurations
* 1.5KV dielectric between coil to contacts
File No.:R9857445
* Various terminals available
* Various sockets available
* Conform to the CE low voltage directive
File No.:CQC02001001941
CONTACT DATA
COIL
1C
Contact Arrangement
2C
DC:0.9W AC:1.2VA
Coil power
50m (at 1A 24VDC)
Initial Contact Resistance Max.
Silver Alloy
Contact Material
1C: 15A 220VAC/28VDC
(Res. Load)
2C: 10A 220VAC/28VDC
250VAC/28VDC
Max. switching voltage
COIL DATA
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
Drop-out
Voltage
VDC
Coil
Resistance
10A
5
4.0
0.5
27.5
10%
3750VAC/450W 2200VAC/280W
6
4.8
0.6
40
10%
12
9.6
1.2
160
10%
24
19.2
2.4
650
10%
48
38.4
4.8
2600
15%
110
88.0
11.0
11000
15%
Nominal
Voltage
VAC
Pick-up
Voltage
VAC
Drop-out
Voltage
VAC
1500VAC 1min.
6
4.80
1.8
11.5
10%
1000VAC 1min.
12
9.60
3.6
46
10%
1500VAC 1min.
24
19.2
7.2
184
10%
Operate time (at nomi. Volt.)
25ms
48
38.4
14.4
735
10%
Release time (at nomi. Volt.)
25ms
120
96.0
36.0
4550
15%
220/240
176.0
66.0
14400
15%
15A
Max. switching current
Max. switching power
Mechanical life
2 x 107 OPS
Electrical life
1 x 105 OPS
CHARACTERISTICS
Initial Insulation Resistance
Between coil and Contacts
Dielectric
Between open contacts
Strength
Between contact sets
Shock Resistance
Vibration Resistance
500M , 500VAC
Functional
100 m/s2
Destructive
1000 m/s2
1 mm, 10 to 55Hz
Humidity
98%RH, +40
Ambient temperature
-40
Termination
PCB & Plug-in
to +70
Coil
Resistance
SAFETY APPROVAL RATINGS
1C:
UL
2C:
15A 250VAC/30VDC
10A 250VAC/30VDC
1/3 HP, 240VAC/120VAC
37g
Unit weight
Construction
Dust cover
HONGFA RELAY
ISO9001*ISO/TS16949 *ISO14001 CERTIFIED
TüV
2C: 10A 250VAC/30VDC
VERSION: EN02-20040601
115
General Purpose Power Relays JQX-13F
Contact Rating
ORDERING INFORMATION
A
JQX-13F /
012
2Z
D 016
1
Type
Coil Source A: AC
Nil: DC
Coil voltage AC: 5 to 110VDC
DC: 6 to 240VAC
Contact arrangement 1Z: 1 Form C
1: Type 1 (Socket) 2: Type 2 (PCB)
3/4/5: Type 3/4/5 (Flange-Mounting)
Mounting Termination
LED D: With LED
2Z: 2 Form C
See the following
Nil: Without LED
Customer special request code (For example: (016) pin number 1,2,3,4,5,6,7,8)
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
JQX-13F/
-1Z1
General Purpose Power Relays JQX-13F
Outline Dimensions
35max
Wiring Diagram
(with LED)
6.4
0.5
8-Ø2.5
1
4
1
5
8
5
8
9
12
9
12
14
13
14
5
13
4
3.2
( Bottom view )
-2Z2
Outline Dimensions
35max.
PCB layout
21.5max.
5
10
0.5
8
9
12
1.5
14
5.75
13
3.5
JQX-13F/
7.15
5
(with LED)
1
4.6
4
28max.
1
Wiring Diagram
8-Ø2.5
14.2
13.15
JQX-13F/
13
1
4
5
4
8
5
8
9
12
9
12
13
14
(Bottom view)
-2Z4
Outline Dimensions
PCB layout
39
30
0.5
4
2.5
6.4
3.5
8-Ø2.5
116
5
13
1
4
5
8
9
12
30
14
28max.
35max.
21.5max.
14
JQX-13F/
-2Z1
Outline Dimensions
6.4
21.5max.
0.5
8-Ø2.5
1
4
1
4
1
4
5
8
5
8
5
8
9
12
9
12
9
12
13
5
2C1D(with LED)
2C1
28max.
35max.
Wiring Diagram
14
13
13
14
14
3.2
(Bottom view)
JQX-13F/
-2Z3
Outline Dimensions
35max
PCB layout
21.5max.
6.4
2-Ø3.5
8
9
12
26
4
5
38
1
28max.
38
43max.
0.5
14
5
13
JQX-13F/
General Purpose Power Relays JQX-13F
3.5
4
21 to 21.3
-2Z5
Outline Dimensions
PCB layout
35max.
21.5max.
2
2-Ø3.5
6.4
9
12
5
13
38
8
38
4
44max.
8-Ø2.5
1
5
28max.
0.5
14
3.2
CHARACTERISTICS CURVE
MAXIMUM SWITCHING POWER(1C)
MAXIMUM SWITCHING POWER(2C)
AC resistive load
10
10
5
5
Contact Current (A)
Contact Current (A)
AC resistive load
DC resistive load
1
0.5
0.1
1
DC resistive load
0.5
0.1
JQX-13F/2Z
JQX-13F/1Z
5
10
50
100
500
Contact Voltage (V)
5
10
50
100
500
Contact Voltage (V)
117