DBLECTRO JZC-33FCS10DC12V0.45

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
JZC-33F
NHG RELAYS
JZC-33F
Operation condition
03001003510
R
R50016343
20.5 10.6 15.6
C
US
E160644
Features
5A 10A switching capabilities.
Subminiature,standard PC layout.
Sealed & Unsealed types available.
Insulation Resistance
100M
min (at 500VDC)
Dielectric Strength
Between contacts
Between contact and coil
50Hz 1000V
50Hz 4000V
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2 11ms
10~50Hz double amplitude 1.5mm
10N
235
2
3 0.5s
-40~70
9 5% (at 35 )
7g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
Perform the qualification test as specified in the table
Safety approval
6
4 Contact current 3A,5A,10A
5 Coil rated voltage(V) DC:3,5,6,9,12,18,24
6 Coil power consumption 0.2:0.2W 0.45:0.45W
Operation al
life
Electrical
Mechanical
Max.Switching Current:10A
100m
10 5
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
10
7
Dash
numbers
Coil
resistance
10%
20.5
10.6
0.807
0.417
Item 3.31 of IEC255-7
Pickup
voltage
V(max)
75%of rated
Volt
Rated
Max.
003-200
005-200
006-200
009-200
012-200
018-200
024-200
3
5
6
9
12
18
24
3.3
5.5
6.6
9.9
13.2
19.8
26.4
45
125
180
405
720
1620
2880
2.25
3.75
4.50
6.75
9.00
13.5
18.0
0.15
0.25
0.30
0.45
0.60
0.90
1.20
003-450
005-450
006-450
009-450
012-450
018-450
024-450
3
5
6
9
12
18
24
3.3
5.5
6.6
9.9
13.2
19.8
26.4
20
56
80
180
320
720
1280
2.25
3.75
4.50
6.75
9.00
13.5
18.0
0.15
0.25
0.30
0.45
0.60
0.90
1.20
3.8
0.150
Release
voltage
VDC(min)
5%of rated
Volt
1C
0.1
5-0.8 0.3
0.031 0.012
1.45
0.057
Coil Parameter
Rated
voltage
VDC
5- 1.3
0.051
2.54
30VDC 277VAC
(1A/24VDC)
7.62
0.300
7.62
0.300
3.8
0.150
0.400
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
7.62
Contact Resistance or Voltage drop
10.6
0.417
10.16
Motor load:1/4HP 250VAC
Lamp load:TV-5
150W 1250VA
Max. Switching Power
Max. Switching Voltage
mm /inch
20.5
0.807
1A:5A/250VAC,30VDC;10A/125VAC
1C:NO:5A/250VAC,30VDC;10A/125VAC
NC:3A,5A/250VAC,30VDC
Contact Rating(resistive)
5A/250VAC
Dimensions
1A (SPSTNO) 1C (SPDT (B-M))
Ag Silver Alloy
Contact Material
CQC
5A/250VAC,28VDC
8
10.16
7.62
4- 1.3
0.400
0.300
0.051
1A
5-0.8 0.3
0.031 0.012
1.45
0.057
Dimensions
0.20
0.300
Contact Arrangement
10A/125VAC 5A/250VAC
1/4HP 250VAC TV-5
4.2A/277VAC1/4HP 277VAC
277VAC 240VAC 120VAC
Load
Contact Data
TUV
15.6
0.614
1 Part number JZC-33F
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
UL & CUR
15.6
0.614
5
0.4
0.016
4
0.4
0.016
3
of IEC255-19-1 and minimum sample size 24.
Safety approvals
JZC-33F C S 10 DC12V 0.45
2
IEC68-2-3Test Ca
Qualification inspection:
Ordering Information
1
Item 7 of IEC255-5
Mounting (Bottom view)
5
1C
1A
Wiring diagram
(Bottom view)
0.45
8
5
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Forward Relay Corporation LTD.
62
JZC-33F
JZC-33F
Operation condition
03001003510
R
R50016343
20.5 10.6 15.6
C
US
E160644
Features
5A 10A switching capabilities.
Subminiature,standard PC layout.
Sealed & Unsealed types available.
Insulation Resistance
100M
min (at 500VDC)
Dielectric Strength
Between contacts
Between contact and coil
50Hz 1000V
50Hz 4000V
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2 11ms
10~50Hz double amplitude 1.5mm
10N
235
2
3 0.5s
-40~70
9 5% (at 35 )
7g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
Perform the qualification test as specified in the table
Safety approval
6
4 Contact current 3A,5A,10A
5 Coil rated voltage(V) DC:3,5,6,9,12,18,24
6 Coil power consumption 0.2:0.2W 0.45:0.45W
Operation al
life
Electrical
Mechanical
Max.Switching Current:10A
100m
10 5
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
10
7
Dash
numbers
Coil
resistance
10%
20.5
10.6
0.807
0.417
Item 3.31 of IEC255-7
Pickup
voltage
V(max)
75%of rated
Volt
Rated
Max.
003-200
005-200
006-200
009-200
012-200
018-200
024-200
3
5
6
9
12
18
24
3.3
5.5
6.6
9.9
13.2
19.8
26.4
45
125
180
405
720
1620
2880
2.25
3.75
4.50
6.75
9.00
13.5
18.0
0.15
0.25
0.30
0.45
0.60
0.90
1.20
003-450
005-450
006-450
009-450
012-450
018-450
024-450
3
5
6
9
12
18
24
3.3
5.5
6.6
9.9
13.2
19.8
26.4
20
56
80
180
320
720
1280
2.25
3.75
4.50
6.75
9.00
13.5
18.0
0.15
0.25
0.30
0.45
0.60
0.90
1.20
3.8
0.150
Release
voltage
VDC(min)
5%of rated
Volt
1C
0.1
5-0.8 0.3
0.031 0.012
1.45
0.057
Coil Parameter
Rated
voltage
VDC
5- 1.3
0.051
2.54
30VDC 277VAC
(1A/24VDC)
7.62
0.300
7.62
0.300
3.8
0.150
0.400
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
7.62
Contact Resistance or Voltage drop
10.6
0.417
10.16
Motor load:1/4HP 250VAC
Lamp load:TV-5
150W 1250VA
Max. Switching Power
Max. Switching Voltage
mm /inch
20.5
0.807
1A:5A/250VAC,30VDC;10A/125VAC
1C:NO:5A/250VAC,30VDC;10A/125VAC
NC:3A,5A/250VAC,30VDC
Contact Rating(resistive)
5A/250VAC
Dimensions
1A (SPSTNO) 1C (SPDT (B-M))
Ag Silver Alloy
Contact Material
CQC
5A/250VAC,28VDC
8
10.16
7.62
4- 1.3
0.400
0.300
0.051
1A
5-0.8 0.3
0.031 0.012
1.45
0.057
Dimensions
0.20
0.300
Contact Arrangement
10A/125VAC 5A/250VAC
1/4HP 250VAC TV-5
4.2A/277VAC1/4HP 277VAC
277VAC 240VAC 120VAC
Load
Contact Data
TUV
15.6
0.614
1 Part number JZC-33F
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
UL & CUR
15.6
0.614
5
0.4
0.016
4
0.4
0.016
3
of IEC255-19-1 and minimum sample size 24.
Safety approvals
JZC-33F C S 10 DC12V 0.45
2
IEC68-2-3Test Ca
Qualification inspection:
Ordering Information
1
Item 7 of IEC255-5
Mounting (Bottom view)
5
1C
1A
Wiring diagram
(Bottom view)
0.45
8
5
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
61
Ningbo Huaguan Relay Corporation LTD.