DDR SDRAM K4H281638L 128Mb L-die DDR SDRAM Specification 66 TSOP-II with Lead-Free and Halogen-Free (RoHS compliant) INFORMATION IN THIS DOCUMENT IS PROVIDED IN RELATION TO SAMSUNG PRODUCTS, AND IS SUBJECT TO CHANGE WITHOUT NOTICE. NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS GRANTING ANY LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IN SAMSUNG PRODUCTS OR TECHNOLOGY. ALL INFORMATION IN THIS DOCUMENT IS PROVIDED ON AS "AS IS" BASIS WITHOUT GUARANTEE OR WARRANTY OF ANY KIND. 1. For updates or additional information about Samsung products, contact your nearest Samsung office. 2. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where Product failure could result in loss of life or personal or physical harm, or any military or * Samsung Electronics reserves the right to change products or specification without notice. 1 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Table of Contents 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Key Features ...............................................................................................................................4 Ordering Information ..................................................................................................................4 Operating Frequencies ...............................................................................................................4 Pin / Ball Description ..................................................................................................................5 Package Physical Dimension ....................................................................................................7 Block Diagram (2Mb x 16 I/O x4 Banks) ....................................................................................9 FUNCTIONAL DESCRIPTION ....................................................................................................10 7.1 Power-up & Initialization Sequence .............................................................................................10 7.2 Mode Register Definition ............................................................................................................11 7.3 Extended Mode Register Set(EMRS) ............................................................................................13 8.0 Input/Output Function Description .........................................................................................14 9.0 Command Truth Table ..............................................................................................................15 10.0 General Description ................................................................................................................16 11.0 Absolute Maximum Rating .....................................................................................................16 12.0 DC Operating Conditions .......................................................................................................16 13.0 DDR SDRAM Spec Items & Test Conditions ........................................................................17 14.0 Input/Output Capacitance ......................................................................................................17 15.0 Detailed test condition for DDR SDRAM IDD1 & IDD7A ......................................................18 16.0 DDR SDRAM IDD spec table ..................................................................................................19 17.0 AC Operating Conditions .......................................................................................................20 18.0 AC Overshoot/Undershoot specification for Address and Control Pins ...........................20 19.0 Overshoot/Undershoot specification for Data, Strobe and Mask Pins ..............................21 20.0 AC Timming Parameters & Specifications ...........................................................................22 21.0 System Characteristics for DDR SDRAM .............................................................................23 22.0 Component Notes ...................................................................................................................24 23.0 System Notes ..........................................................................................................................26 24.0 IBIS : I/V Characteristics for Input and Output Buffers .......................................................27 2 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Revision History Revision Month Year History 1.0 September 2008 - Release rev.1.0 SPEC - Corrected max tCK complying JEDEC 1.1 October 2008 - Changed tCK max of 400/333Mbps to 10ns from 12ns - Corrected IDD1 current measurement condition 1.2 February 2009 - Added FBGA package SPEC - Corrected matched drive strength SPEC. 3 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 1.0 Key Features • VDD : 2.5V ± 0.2V, VDDQ : 2.5V ± 0.2V for DDR333, 400 • VDD : 2.5V ± 5%, VDDQ : 2.5V ± 5% for DDR500 • Double-data-rate architecture; two data transfers per clock cycle • Bidirectional data strobe [L(U)DQS] (x16) • Four banks operation • Differential clock inputs(CK and CK) • DLL aligns DQ and DQS transition with CK transition • MRS cycle with address key programs -. Read latency : DDR333(2.5 Clock), DDR400(3 Clock), DDR500(3 Clock) -. Burst length (2, 4, 8) -. Burst type (sequential & interleave) • All inputs except data & DM are sampled at the positive going edge of the system clock(CK) • Data I/O transactions on both edges of data strobe • Edge aligned data output, center aligned data input • LDM,UDM for write masking only (x16) • Auto & Self refresh • 15.6us refresh interval(4K/64ms refresh) • Maximum burst refresh cycle : 8 • 66pin TSOP II Lead-Free and Halogen-Free package • RoHS compliant 2.0 Ordering Information Part No. Org. K4H281638L-LCCD Max Freq. Interface Package SSTL2 66pin TSOP II Lead-Free & Halogen-Free CD(DDR500@CL=3) K4H281638L-LCCC 8M x 16 K4H281638L-LCB3 CC(DDR400@CL=3) Note B3(DDR333@CL=2.5) 3.0 Operating Frequencies CD(DDR500@CL=3) CC(DDR400@CL=3) B3(DDR333@CL=2.5) Speed @CL2 N/A N/A N/A Speed @CL2.5 166MHz 166MHz 166MHz Speed @CL3 250MHz 200MHz - CL-tRCD-tRP 3-4-4 3-3-3 2.5-3-3 4 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 4.0 Pin / Ball Description 66pin TSOP - II 8Mb x 16 VDD 1 66 VSS DQ0 2 65 DQ15 VDDQ 3 64 VSSQ DQ1 4 63 DQ14 DQ2 5 62 DQ13 VSSQ 6 61 VDDQ DQ3 7 60 DQ12 DQ4 8 59 DQ11 VDDQ 9 58 VSSQ DQ5 10 57 DQ10 56 DQ9 55 VDDQ 54 DQ8 53 NC 52 VSSQ 51 UDQS 50 NC 49 VREF 48 VSS DQ6 11 VSSQ 12 DQ7 13 NC 14 VDDQ 15 LDQS 16 NC 17 VDD 18 66Pin TSOPII (400mil x 875mil) (0.65mm Pin Pitch) Bank Address BA0~BA1 Auto Precharge A10 NC 19 LDM 20 47 UDM WE 21 46 CK CAS 22 45 CK RAS 23 44 CKE CS 24 43 NC NC 25 42 NC BA0 26 41 A11 BA1 27 40 A9 AP/A10 28 39 A8 A0 29 38 A7 A1 30 37 A6 A2 31 36 A5 A3 32 35 A4 VDD 33 34 VSS 128Mb TSOP-II Package Pinout Organization Row Address Column Address 8Mx16 A0~A11 A0-A8 DM is internally loaded to match DQ and DQS identically. Row & Column address configuration 5 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 60ball FBGA (Top View) 4M x 16 9 VDDQ DQ1 DQ3 DQ5 DQ7 NC 8 DQ0 VSSQ VDDQ VSSQ VDDQ VDD CAS CS BA0 A10/AP A1 A3 7 VDD DQ2 DQ4 DQ6 LDQS LDM WE RAS BA1 A0 A2 VDD A B C D E F G H J K L M 3 VSS DQ13 DQ11 DQ9 UDQS UDM CK CKE A9 A7 A5 VSS 2 DQ15 VDDQ VSSQ VDDQ VSSQ VSS CK NC A11 A8 A6 A4 1 VSSQ DQ14 DQ12 DQ10 DQ8 VREF 64Mb FBGA Package ballout Organization Row Address Column Address 4Mx16 A0~A11 A0-A7 DM is internally loaded to match DQ and DQS identically. Row & Column address configuration 6 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L #33 (10.76) (0.50) NOTE 1. ( ) IS REFERENCE 2. [ ] IS ASS’Y OUT QUALITY Detail A 0. 25 ) 0.075 MAX (4°) [ (R Detail B 0. 25 ) Detail A (R 0.65TYP [0.65 ± 0.08] 0.05 MIN 0.10 MAX 0.45 ~ 0.75 1.20 MAX 1.00 ± 0.10 (10°) (R (10°) (10°) (0.80) (1.50) (10°) 0. 15 ) 0.210 ± 0.05 (R 0.1 5) 0.125 - 0.035 [ 0.665 ± 0.05 +0.075 22.22 ± 0.10 (0.71) Unit : mm 11.76 ± 0.20 #1 (1.50) (0.80) #34 10.16 ± 0.10 #66 (0.50) 5.0 Package Physical Dimension 0.25TYP Detail B (0° ∼ 8°) 0.25 ± 0.08 0.30 ± 0.08 66Pin TSOP(II) Package Dimension 7 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Units : Millimeters 0.10 Max 8.00 ± 0.10 #A1 MARK 0.80 x 8 = 6.40 8.0 0 ± 0.10 0.80 1.60 B 9 8 7 6 5 4 3 2 1 A B (Datum B) C F 0.50 G H 12.00 ± 0.10 E 1.00 x 11 = 11.00 D 12.00 ± 0.10 J K 1.00 #A1 A L M 0.32 ± 0.05 1.10 ± 0.10 60 - ∅ 0.45 SOLDER BALL (Post Reflow 0.50 ± 0.05) ∅0.20 M (Datum A) A B TOP VIEW BOTTOM VIEW 60Ball FBGA 64Mb Package Dimension 8 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 6.0 Block Diagram (2Mb x 16 I/O x4 Banks) CK, CK LWE I/O Control x4/8/16 Data Input Register LUDM (x16) Serial to parallel Bank Select x8/16/32 1Mx32 16 16 DQi 1Mx32 Column Decoder Col. Buffer LCBR LRAS Latency & Burst Length Programming Register LRAS LCBR LWE LCAS LWCBR Timing Register CK, CK CKE CS RAS CAS WE 9 of 32 Strobe Gen. DLL LCKE Output Buffer 1Mx32 32 2-bit prefetch Sense AMP Row Decoder Refresh Counter Row Buffer ADD Address Register CK, CK 1Mx32 Data Strobe LUDM (x16) CK, CK DM Input Register LUDM (x16) Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 7.0 FUNCTIONAL DESCRIPTION 7.1 Power-up & Initialization Sequence DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. No power sequencing is specified during power up and power down given the following • • • • • • • VDD and VDDQ are driven from a single power converter output, AND VTT is limited to 1.35 V, AND VREF tracks VDDQ/2 OR, the following relationships must be followed: VDDQ is driven after or with VDD such that VDDQ < VDD + 0.3 V AND VTT is driven after or with VDDQ such that VTT < VDDQ + 0.3 V, AND VREF is driven after or with VDDQ such that VREF < VDDQ + 0.3 V. At least one of these two conditions must be met. Except for CKE, inputs are not recognized as valid until after VREF is applied. CKE is an SSTL_2 input, but will detect an LVCMOS LOW level after VDD is applied. Maintaining an LVCMOS LOW level on CKE during power up is required to guarantee that the DQ and DQS outputs will be in the High–Z state, where they will remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200 µs delay prior to applying an executable command. Once the 200 µs delay has been satisfied, a DESELECT or NOP command should be applied, and CKE should be brought HIGH. Following the NOP command, a PRECHARGE ALL command should be applied. Next a MODE REGISTER SET command should be issued for the Extended Mode Register, to enable the DLL, then a MODE REGISTER SET command should be issued for the Mode Register, to reset the DLL, and to program the operating parameters. 200 clock cycles are required between the DLL reset and any read command. A PRECHARGE ALL command should be applied, placing the device in the ”all banks idle” state. Once in the idle state, two AUTO refresh cycles must be performed. Additionally, a MODE REGISTER SET command for the Mode Register, with the reset DLL bit deactivated (i.e., to program operating parameters without resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation. 10 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 7.2 Mode Register Definition Mode Register Set(MRS) The mode register stores the data for controlling the various operating modes of DDR SDRAM. It programs CAS latency, addressing mode, burst length, test mode, DLL reset and various vendor specific options to make DDR SDRAM useful for variety of different applications. The default value of the mode register is not defined, therefore the mode register must be written after EMRS setting for proper DDR SDRAM operation. The mode register is written by asserting low on CS, RAS, CAS, WE and BA0(The DDR SDRAM should be in all bank precharge with CKE already high prior to writing into the mode register). The states of address pins A0 ~ A11 in the same cycle as CS, RAS, CAS, WE and BA0 going low are written in the mode register. Two clock cycles are requested to complete the write operation in the mode register. The mode register contents can be changed using the same command and clock cycle requirements during operation as long as all banks are in the idle state. The mode register is divided into various fields depending on functionality. The burst length uses A0 ~ A2, addressing mode uses A3, CAS latency(read latency from column address) uses A4 ~ A6. A7 is used for test mode. A8 is used for DLL reset. A7 must be set to low for normal MRS operation. Refer to the table for specific codes for various burst lengths, addressing modes and CAS latencies. BA1 BA0 RFU 0 A11 A10 A9 RFU A8 A7 A6 DLL TM A5 A4 CAS Latency A2 BT A1 DLL Reset A7 mode A3 Burst Type 0 No 0 Normal 0 Sequential 1 Yes 1 Test 1 Interleave An ~ A0 Address Bus Mode Register Burst Length A6 A5 A4 Latency A2 A1 0 (Existing)MRS Cycle 0 0 0 Reserve 1 Extended Funtions(EMRS) 0 0 1 Reserve 0 0 0 1 0 Reserve 0 0 0 1 1 3 0 1 1 0 0 Reserve 0 1 0 1 Reserve 1 1 0 2.5 1 1 1 Reserve * RFU(Reserved for future use) must stay "0" during MRS cycle. A0 Burst Length A8 CAS Latency BA0 A3 A0 Burst Length Sequential Interleave 0 Reserve Reserve 1 2 2 0 4 4 1 1 8 8 1 0 0 Reserve Reserve 1 0 1 Reserve Reserve 1 1 0 Reserve Reserve 1 1 1 Reserve Reserve Note : *1 A12 is used for 256Mb only. That is 128Mb uses A0~A11 11 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Burst Address Ordering for Burst Length Burst Length Starting Address(A2, A1, A0) 2 4 8 Sequential Mode Interleave Mode xx0 0, 1 0, 1 xx1 1, 0 1, 0 x00 0, 1, 2, 3 0, 1, 2, 3 x01 1, 2, 3, 0 1, 0, 3, 2 x10 2, 3, 0, 1 2, 3, 0, 1 x11 3, 0, 1, 2 3, 2, 1, 0 000 0, 1, 2, 3, 4, 5, 6, 7 0, 1, 2, 3, 4, 5, 6, 7 001 1, 2, 3, 4, 5, 6, 7, 0 1, 0, 3, 2, 5, 4, 7, 6 010 2, 3, 4, 5, 6, 7, 0, 1 2, 3, 0, 1, 6, 7, 4, 5 011 3, 4, 5, 6, 7, 0, 1, 2 3, 2, 1, 0, 7, 6, 5, 4 100 4, 5, 6, 7, 0, 1, 2, 3 4, 5, 6, 7, 0, 1, 2, 3 101 5, 6, 7, 0, 1, 2, 3, 4 5, 4, 7, 6, 1, 0, 3, 2 110 6, 7, 0, 1, 2, 3, 4, 5 6, 7, 4, 5, 2, 3, 0, 1 111 7, 0, 1, 2, 3, 4, 5, 6 7, 6, 5, 4, 3, 2, 1, 0 Mode Register Set 0 1 2 3 4 5 6 7 8 CK CK *1 Mode Register Set Precharge All Banks Command tCK tRP*2 Any Command 2 Clock min. *1 : MRS can be issued only at all bank precharge state. *2 : Minimum tRP is required to issue MRS command. 12 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 7.3 Extended Mode Register Set(EMRS) The extended mode register stores the data for enabling or disabling DLL, and selecting output driver size. The default value of the extended mode register is not defined, therefore the extened mode register must be written after power up for enabling or disabling DLL. The extended mode register is written by asserting low on CS, RAS, CAS, WE and high on BA0(The DDR SDRAM should be in all bank precharge with CKE already high prior to writing into the extended mode register). The state of address pins A0 ~ A11 and BA1 in the same cycle as CS, RAS, CAS and WE going low are written in the extended mode register. Two clock cycles are required to complete the write operation in the extended mode register. The mode register contents can be changed using the same command and clock cycle requirements during operation as long as all banks are in the idle state. A0 is used for DLL enable or disable. "High" on BA0 is used for EMRS. All the other address pins except A0, A1, A6, A11 and BA0 must be set to low for proper EMRS operation. Refer to the table for specific codes. BA1 BA0 A11 *RFU 1 D.I.C BA0 An ~ A0 0 MRS 1 EMRS A10 A9 A8 A7 *RFU A6 A5 A4 D.I.C A3 *RFU A1 A0 Address Bus D.I.C DLL Extended Mode Register A2 Output Driver Impedence Contol A11 Vendor ID & Die Status Identification A6 A1 0 off 0 0 Full 1 on 0 1 Weak 1 1 Matced A0 DLL Enable 0 Enable 1 Disable *RFU : Should stay " 0" during EMRS cycle. Figure 7. Extend Mode Register set DLL Enable/Disable The DLL must be enabled for normal operation. DLL enable is required during powerup initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation (upon exiting Self Refresh Mode, the DLL is enabled automatically). Any time the DLL is enabled, 200 clock cycles must occur before a READ command can be issued. Output Drive Strength The normal drive strength for all outputs is specified to be SSTL_2, Class II. Samsung supports a weak driver strength option, intended for lighter load and/or point-to-point environments. I-V curves for the normal drive strength and weak drive strength are included in 11.1~2 of this document. MANUFACTURERS VENDOR CODE AND DIE STATUS IDENTIFICATION The Manufacturers Vendor Code, V, is selected by issuing a EXTENDED MODE REGISTER SET command with bits A11 set to one, and bits A0-A10 set to the desired values. When the V function is enabled the 128Mb DDR SDRAM will provide its manufacturers vendor code and die status identification on DQ[1:0]. DQ[1:0] Vendor ID/DSI 00 Samsung / Pass 01 Samsung / Fail 10 Reserved / Pass 11 Reserved / Fail 13 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 8.0 Input/Output Function Description SYMBOL TYPE DESCRIPTION CK, CK Input Clock : CK and CK are differential clock inputs. All address and control input signals are sampled on the positive edge of CK and negative edge of CK. Output (read) data is referenced to both edges of CK. Internal clock signals are derived from CK/CK. CKE Input Clock Enable : CKE HIGH activates, and CKE LOW deactivates internal clock signals, and device input buffers and output drivers. Taking CKE Low provides PRECHARGE POWERDOWN and SELF REFRESH operation (all banks idle), or ACTIVE POWER DOWN (row ACTIVE in any bank). CKE is synchronous for POWER DOWN entry and exit, and for SELF REFRESH entry. CKE is asynchronous for SELF REFRESH exit, and for output disable. CKE must be maintained high throughput READ and WRITE accesses. Input buffers, excluding CK, CK and CKE are disabled during POWER DOWN. Input buffers, excluding CKE are disabled during SELF REFRESH. CKE is an SSTL_2 input, but will detect an LVCMOS Low level after VDD is applied upon 1st power up, After VREF has become stable during the power on and initialization sequence, it must be maintained for proper operation of the CKE receiver. For proper SELF REFRESH entry and exit, VREF must be maintained to this input. CS Input Chip Select : CS enables(registered LOW) and disables(registered HIGH) the command decoder. All commands are masked when CS is registered HIGH. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. RAS, CAS, WE Input Command Inputs : RAS, CAS and WE (along with CS) define the command being entered. LDM,(UDM) Input Input Data Mask : DM is an input mask signal for write data. Input data is masked when DM is sampled HIGH along with that input data during a WRITE access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. For the x16, LDM corresponds to the data on DQ0~D7 ; UDM corresponds to the data on DQ8~DQ15. DM may be driven high, low, or floating during READs. BA0, BA1 Input Bank Addres Inputs : BA0 and BA1 define to which bank an ACTIVE, READ, WRITE or PRECHARGE command is being applied. A [0 : 11] Input Address Inputs : Provide the row address for ACTIVE commands, and the column address and AUTO PRECHARGE bit for READ/WRITE commands, to select one location out of the memory array in the respective bank. A10 is sampled during a PRECHARGE command to determine whether the PRECHARGE applies to one bank (A10 LOW) or all banks (A10 HIGH). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op code during a MODE REGISTER SET command. BA0 and BA1 define which mode register is loaded during the MODE REGISTER SET command (MRS or EMRS). DQ I/O Data Input/Output : Data bus LDQS,(U)DQS I/O Data Strobe : Output with read data, input with write data. Edge-aligned with read data, centered in write data. Used to capture write data. For the x16, LDQS corresponds to the data on DQ0~D7 ; UDQS corresponds to the data on DQ8~DQ15. NC - VDDQ Supply DQ Power Supply : +2.5V ± 0.2V. VSSQ Supply DQ Ground. VDD Supply Power Supply : +2.5V ± 0.2V. VSS Supply Ground. VREF Input No Connect : No internal electrical connection is present. SSTL_2 reference voltage. 14 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 9.0 Command Truth Table COMMAND (V=Valid, X=Don′t Care, H=Logic High, L=Logic Low) CKEn-1 CKEn CS RAS CAS WE BA0,1 A10/AP A0 ~ A9, A11 Note Register Extended MRS H X L L L L OP CODE 1, 2 Register Mode Register Set H X L L L L OP CODE 1, 2 L L L H X Auto Refresh Refresh Self Refresh Entry Exit H H L L H H H H X X X X L L H H V X L H L H V L H Bank Active & Row Addr. H Read & Column Address Auto Precharge Disable H Write & Column Address Auto Precharge Disable Auto Precharge Enable H X L H L L H X L H H L H X L L H L Entry H L H X X X L V V V Exit L H Auto Precharge Enable Burst Stop Precharge Bank Selection All Banks Active Power Down Entry H L Precharge Power Down Mode Exit L UDM/LDM for x16 H No operation (NOP) : Not defined H H X X X X H X X X L H H H H X X X L V V V X X X X X L H H H 3 3 X V 3 Row Address L Column Address H L Column Address H X V L X H 4 4 4 4, 6 7 X 5 X X X H 3 X 8 9 9 Note : 1. OP Code : Operand Code. A0 ~ A11& BA0 ~ BA1 : Program keys. (@EMRS/MRS) 2. EMRS/MRS can be issued only at all banks precharge state. A new command can be issued 2 clock cycles after EMRS or MRS. 3. Auto refresh functions are same as the CBR refresh of DRAM. The automatical precharge without row precharge command is meant by "Auto". Auto/self refresh can be issued only at all banks precharge state. 4. BA0 ~ BA1 : Bank select addresses. If both BA0 and BA1 are "Low" at read, write, row active and precharge, bank A is selected. If BA0 is "High" and BA1 is "Low" at read, write, row active and precharge, bank B is selected. If BA0 is "Low" and BA1 is "High" at read, write, row active and precharge, bank C is selected. If both BA0 and BA1 are "High" at read, write, row active and precharge, bank D is selected. 5. If A10/AP is "High" at row precharge, BA0 and BA1 are ignored and all banks are selected. 6. During burst write with auto precharge, new read/write command can not be issued. Another bank read/write command can be issued after the end of burst. New row active of the associated bank can be issued at tRP after the end of burst. 7. Burst stop command is valid at every burst length. 8. UDM/LDM(x16 only) sampled at the rising and falling edges of the UDQS/LDQS and Data-in are masked at the both edges (Write UDM/LDM latency is 0). 9. This combination is not defined for any function, which means "No Operation(NOP)" in DDR SDRAM. 15 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 2M x 16Bit x 4 Banks Double Data Rate SDRAM 10.0 General Description The K4H281638L is 134,217,728 bits of double data rate synchronous DRAM organized as 4x 2,097,152 words by 16bits, fabricated with SAMSUNG′s high performance CMOS technology. Synchronous features with Data Strobe allow extremely high performance up to 500Mb/s per pin. I/O transactions are possible on both edges of DQS. Range of operating frequencies, programmable burst length and programmable latencies allow the device to be useful for a variety of high performance memory system applications. 11.0 Absolute Maximum Rating Parameter Symbol Value Unit Voltage on any pin relative to VSS VIN, VOUT -0.5 ~ 3.6 V Voltage on VDD & VDDQ supply relative to VSS VDD, VDDQ 1.0 ~ 3.6 V Storage temperature TSTG -55 ~ +150 °C Power dissipation PD 1 W Short circuit current IOS 50 mA Note : Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. Functional operation should be restricted to recommend operation condition. Exposure to higher than recommended voltage for extended periods of time could affect device reliability. 12.0 DC Operating Conditions Recommended operating conditions(Voltage referenced to VSS=0V, TA=0 to 70°C) Parameter Symbol Min Max Unit Supply voltage (for device with a nominal VDD of 2.5V for DDR333, 400) VDD 2.3 2.7 V Supply voltage (for device with a nominal VDD of 2.5V for DDR500) VDD 2.375 2.625 V I/O Supply voltage (for device with a nominal VDD of 2.5V for DDR333, 400) VDDQ 2.3 2.7 V I/O Supply voltage (for device with a nominal VDD of 2.5V for DDR500) VDDQ 2.375 2.625 V I/O Reference voltage VREF 0.49*VDDQ 0.51*VDDQ V 1 VTT VREF-0.04 VREF+0.04 V 2 Input logic high voltage VIH(DC) VREF+0.15 VDDQ+0.3 V Input logic low voltage VIL(DC) -0.3 VREF-0.15 V Input Voltage Level, CK and CK inputs VIN(DC) -0.3 VDDQ+0.3 V Input Differential Voltage, CK and CK inputs VID(DC) 0.36 VDDQ+0.6 V 3 V-I Matching: Pullup to Pulldown Current Ratio VI(Ratio) 0.71 1.4 - 4 II -2 2 uA Output leakage current IOZ -5 5 uA Output High Current(Full strengh driver) ; VOUT=VDDQ-0.388V IOH -13.8 -16.1 mA Output LowCurrent(Full strengh driver) ; VOUT=0.388V IOL 16.5 19.2 mA Output High Current(Week strengh driver) ; VOUT=VDDQ-0.538V IOH -18.2 -21.8 mA Output Low Current(Week strengh driver) ; VOUT=0.538V IOL 20.2 24.5 mA Output High Current(Mached strengh driver) ; VOUT=VDDQ-0.6505V IOH -15.5 -18.9 mA Output Low Current(Mached strengh driver) ; VOUT=0.6505V IOL 17 21.3 mA I/O Termination voltage(system) Input leakage current Note Note : 1. VREF is expected to be equal to 0.5*VDDQ of the transmitting device, and to track variations in the dc level of same. Peak-to peak noise on VREF may not exceed +/-2% of the dc value. 2. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of VREF 3. VID is the magnitude of the difference between the input level on CK and the input level on CK. 4. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages from 0.25V to 1.0V. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. The full variation in the ratio of the maximum to minimum pullup and pulldown current will not exceed 1.7 for device drain to source voltages from 0.1 to 1.0. 16 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 13.0 DDR SDRAM Spec Items & Test Conditions Conditions Symbol Operating current - One bank Active-Precharge; tRC=tRCmin; tCK= 6ns for DDR333, 5ns for DDR400, 4ns for DDR500; DQ,DM and DQS inputs changing once per clock cycle; address and control inputs changing once every two clock cycles. IDD0 Operating current - One bank operation ; One bank open, BL=4, Reads - Refer to the following page for detailed test condition IDD1 Precharge power-down standby current; All banks idle; power - down mode; CKE = <VIL(max); tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500; VIN = VREF for DQ,DQS and DM. IDD2P Precharge Floating standby current; CS > =VIH(min);All banks idle; CKE > = VIH(min); tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500; Address and other control inputs changing once per clock cycle; VIN = VREF for DQ,DQS and DM IDD2F Precharge Quiet standby current; CS > = VIH(min); All banks idle; CKE > = VIH(min); tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500; Address and other control inputs stable at >= VIH(min) or =<VIL(max); VIN = VREF for DQ ,DQS and DM IDD2Q Active power - down standby current ; one bank active; power-down mode; CKE=< VIL (max); tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500; VIN = VREF for DQ,DQS and DM IDD3P Active standby current; CS >= VIH(min); CKE>=VIH(min); one bank active; active - precharge;tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500; DQ, DQS and DM inputs changing twice per clock cycle; address and other control inputs changing once per clock cycle IDD3N Operating current - burst read; Burst length = 2; reads; continguous burst; One bank active; address and control inputs changing once per clock cycle; CL=2.5 at tCK=6ns for DDR333, CL=3 at tCK=5ns for DDR400, tCK=4ns for DDR500; 50% of data changing on every transfer; lout = 0 m A IDD4R Operating current - burst write; Burst length = 2; writes; continuous burst; One bank active address and control inputs changing once per clock cycle; CL=2.5 at tCK=6ns for DDR333, 5ns for DDR400, tCK=4ns for DDR500; DQ, DM and DQS inputs changing twice per clock cycle, 50% of input data changing at every burst IDD4W Auto refresh current; tRC = tRFC(min) which is 12*tCK for DDR333 at tCK=6ns, 14*tCK for DDR400 at tCK=5ns, 15*tCK for DDR500 at tCK=4ns; distributed refresh IDD5 Self refresh current; CKE =< 0.2V; External clock on; tCK=6ns for DDR333, 5ns for DDR400, 4ns for DDR500. IDD6 Operating current - Four bank operation ; Four bank interleaving with BL=4 -Refer to the following page for detailed test condition IDD7A 14.0 Input/Output Capacitance Parameter ( TA= 25°C, f=100MHz) Symbol Min Max DeltaCap(max) Unit Note Input capacitance (A0 ~ A11, BA0 ~ BA1, CKE, CS, RAS,CAS, WE) CIN1 1 4 0.5 pF 4 Input capacitance( CK, CK ) CIN2 1 5 0.25 pF 4 Data & DQS input/output capacitance COUT 1 6.5 pF 1,2,3,4 Input capacitance(UDM/LDM for x16) CIN3 1 6.5 pF 1,2,3,4 0.5 Note : 1. These values are guaranteed by design and are tested on a sample basis only. 2. Although DM is an input -only pin, the input capacitance of this pin must model the input capacitance of the DQ and DQS pins. This is required to match signal propagation times of DQ, DQS, and DM in the system. 3. Unused pins are tied to ground. 4. This parameteer is sampled. VDDQ = +2.5V +0.2V, VDD = +2.5V+0.2V. For all devices, f=100MHz, tA=25°C, VOUT(DC) = VDDQ/2, VOUT(peak to peak) = 0.2V. DM inputs are grouped with I/O pins - reflecting the fact that they are matched in loading (to facilitate trace matching at the board level) 17 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 15.0 Detailed test condition for DDR SDRAM IDD1 & IDD7A IDD1 : Operating current: One bank operation 1. Typical Case: VDD = 2.5V, T=25°C Worst Case : VDD = 2.7V, T= 10°C 2. Only one bank is accessed with tRC(min), Burst Mode, Address and Control inputs on NOP edge are changing once per clock cycle. lout = 0mA 3. Timing patterns - B3(166Mhz, CL=2.5) : tCK=6ns, CL=2.5, BL=4, tRCD=3*tCK, tRC = 10*tCK, tRAS=7*tCK Read : A0 N N R0 N N N P0 N N - repeat the same timing with random address changing *50% of data changing at every burst - CC(200Mhz,CL = 3) : tCK = 5ns, CL = 3, BL = 4, tRCD = 3*tCK , tRC = 11*tCK, tRAS = 8*tCK Read : A0 N N R0 N N N N P0 N N - repeat the same timing with random address changing *50% of data changing at every transfer - CD(250Mhz,CL = 3) : tCK = 4ns, CL = 3, BL = 4, tRCD = 4*tCK , tRC = 13*tCK, tRAS = 10*tCK Read : A0 N N N R0 N N N N N P0 N N - repeat the same timing with random address changing *50% of data changing at every transfer Legend : A=Activate, R=Read, W=Write, P=Precharge, N=DESELECT IDD7A : Operating current: Four bank operation 1. Typical Case: VDD = 2.5V, T=25°C Worst Case : VDD = 2.7V, T= 10°C 2. Four banks are being interleaved with tRC(min), Burst Mode, Address and Control inputs on NOP edge are not changing. lout = 0mA 4. Timing patterns - B3(166Mhz,CL=2.5) : tCK=6ns, BL=4, tRRD=2*tCK, tRCD=3*tCK, tRAS=5*tCK Read : A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing *50% of data changing at every burst - CC(200Mhz,CL = 3) : tCK = 5ns, BL = 4, tRRD=2*tCK, tRCD = 3*tCK , tRAS = 8*tCK Read : A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing *50% of data changing at every transfer - CD(250Mhz,CL = 3) : tCK = 4ns, CL = 3, BL = 4, tRCD = 4*tCK , tRAS = 10*tCK Read : A0 N N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing *50% of data changing at every transfer Legend : A=Activate, R=Read, W=Write, P=Precharge, N=DESELECT 18 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 16.0 DDR SDRAM IDD spec table Symbol (VDD=2.7V, T = 10°C) 8Mx16 (K4H281638L) CD(DDR500@CL=3) CC(DDR400@CL=3) B3(DDR333@CL=2.5) Unit IDD0 120 110 100 mA IDD1 130 120 120 mA 40 mA IDD2P 8 IDD2F 40 mA 40 IDD2Q 40 40 40 mA IDD3P 40 35 35 mA IDD3N 55 55 55 mA IDD4R 200 180 160 mA IDD4W 200 180 160 mA IDD5 200 180 160 mA IDD6 Normal IDD7A 3 3 3 mA 300 300 280 mA 19 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 17.0 AC Operating Conditions Parameter/Condition Symbol Min Input High (Logic 1) Voltage, DQ, DQS and DM signals VIH(AC) VREF + 0.31 Input Low (Logic 0) Voltage, DQ, DQS and DM signals. VIL(AC) Input Differential Voltage, CK and CK inputs VID(AC) Input Crossing Point Voltage, CK and CK inputs I/O Reference Voltage Max Unit Note V VREF - 0.31 V 0.7 VDDQ+0.6 V 1 VIX(AC) 0.5*VDDQ-0.2 0.5*VDDQ+0.2 V 2 VREF(AC) 0.45 x VDDQ 0.55 x VDDQ V 3 Note : 1. VID is the magnitude of the difference between the input level on CK and the input level on CK. 2. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the dc level of the same. 3. VREF is expected to equal VDDQ/2 of the transmitting device and to track variations in the DC level of the same. Peak-to-peak noise (non-common mode) on VREF may not exceed ±2 percent of the DC value. Thus, from VDDQ/2, VREF is allowed ± 25mV for DC error and an additional ± 25mV for AC noise. This measurement is to be taken at the nearest VREF by-pass capacitor. 18.0 AC Overshoot/Undershoot specification for Address and Control Pins Specification Parameter DDR400 DDR333 Maximum peak amplitude allowed for overshoot 1.5 V 1.5 V Maximum peak amplitude allowed for undershoot 1.5 V 1.5 V The area between the overshoot signal and VDD must be less than or equal to 4.5 V-ns 4.5 V-ns The area between the undershoot signal and GND must be less than or equal to 4.5 V-ns 4.5 V-ns VDD Overshoot 5 Maximum Amplitude = 1.5V 4 3 Volts (V) 2 Area 1 0 -1 -2 -3 Maximum Amplitude = 1.5V GND -4 -5 0 0.6875 1.5 2.5 3.5 4.5 5.5 6.3125 7.0 0.5 1.0 2.0 3.0 4.0 5.0 6.0 6.5 Tims(ns) undershoot AC overshoot/Undershoot Definition 20 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 19.0 Overshoot/Undershoot specification for Data, Strobe and Mask Pins Specification Parameter DDR400 DDR333 Maximum peak amplitude allowed for overshoot 1.2 V 1.2 V Maximum peak amplitude allowed for undershoot 1.2 V 1.2 V The area between the overshoot signal and VDD must be less than or equal to 2.4 V-ns 2.4 V-ns The area between the undershoot signal and GND must be less than or equal to 2.4 V-ns 2.4 V-ns VDDQ Overshoot 5 Maximum Amplitude = 1.2V 4 3 Volts (V) 2 1 Area 0 -1 -2 -3 Maximum Amplitude = 1.2V GND -4 -5 0 0.5 1.0 1.42 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 5.68 6.0 6.5 7.0 Tims(ns) undershoot DQ/DM/DQS AC overshoot/Undershoot Definition 21 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 20.0 AC Timming Parameters & Specifications Parameter Symbol CD (DDR500@CL=3.0) CC (DDR400@CL=3.0) B3 (DDR333@CL=2.5) Unit Min Max Min Max Min Max tRC 52 - 55 - 60 - ns Refresh row cycle time tRFC 60 - 70 - 72 - ns Row active time tRAS 36 70K 40 70K 42 70K ns RAS to CAS delay tRCD 16 - 15 - 18 - ns tRP 16 - 15 - 18 - ns Row active to Row active delay tRRD 12 - 10 - 12 - ns Write recovery time tWR 12 - 15 - 15 - ns tWTR 2 - 2 - 1 - tCK tCK 6 10 6 10 6 10 ns 4 8 5 8 - - Clock high level width tCH 0.45 0.55 0.45 0.55 0.45 0.55 tCK Clock low level width tCL 0.45 0.55 0.45 0.55 0.45 0.55 tCK tDQSCK -0.6 +0.6 -0.6 +0.6 -0.6 +0.6 ns ns Row cycle time Row precharge time Last data in to Read command Clock cycle time CL=2.5 CL=3.0 DQS-out access time from CK/CK tAC -0.6 +0.6 -0.7 +0.7 -0.7 +0.7 tDQSQ - 0.4 - 0.4 - 0.45 ns Read Preamble tRPRE 0.9 1.1 0.9 1.1 0.9 1.1 tCK Read Postamble tRPST 0.4 0.6 0.4 0.6 0.4 0.6 tCK CK to valid DQS-in tDQSS 0.85 1.15 0.72 1.28 0.75 1.25 tCK DQS-in setup time tWPRES 0 - 0 - 0 - ns DQS-in hold time tWPREH 0.35 - 0.25 - 0.25 - tCK tDSS 0.2 - 0.2 - 0.2 - tCK Output data access time from CK/CK Data strobe edge to ouput data edge TSOP DQS falling edge to CK rising-setup time DQS falling edge from CK rising-hold time tDSH 0.2 - 0.2 - 0.2 - tCK DQS-in high level width tDQSH 0.4 - 0.35 - 0.35 - tCK DQS-in low level width Note 22 13 tDQSL 0.4 - 0.35 - 0.35 - tCK Address and Control Input setup time(fast) tIS 0.9 - 0.6 - 0.75 - ns 15, 17~19 Address and Control Input hold time(fast) tIH 0.9 - 0.6 - 0.75 - ns 15, 17~19 Address and Control Input setup time(slow) tIS 0.9 - 0.7 - 0.8 - ns 16~19 Address and Control Input hold time(slow) tIH 0.9 - 0.7 - 0.8 - ns 16~19 Data-out high impedence time from CK/CK tHZ -0.7 +0.7 -0.65 +0.65 -0.7 +0.7 ns 11 11 tLZ -0.7 +0.7 -0.65 +0.65 -0.7 +0.7 ns Mode register set cycle time tMRD 8 - 10 - 12 - ns DQ & DM setup time to DQS tDS 0.4 - 0.4 - 0.45 - ns j, k 0.45 - ns j, k Data-out low impedence time from CK /CK DQ & DM hold time to DQS tDH Control & Address input pulse width 0.4 - 0.4 - tIPW 2.2 - 2.2 - 2.2 - ns 18 DQ & DM input pulse width tDIPW 1.75 - 1.75 - 1.75 - ns 18 Exit self refresh to non-Read command tXSNR 75 - 75 - 75 - ns Exit self refresh to read command tXSRD 200 - 200 - 200 - tCK Refresh interval time tREFI 15.6 Output DQS valid window tQH tHP -tQHS Clock half period tHP tCLmin or tCHmin Data hold skew factor DQS write postamble time TSOP tQHS 15.6 - tHP -tQHS - tCLmin or tCHmin 0.4 15.6 us 14 - tHP -tQHS - ns 21 - tCLmin or tCHmin - ns 20, 21 0.55 ns 21 tCK 12 23 0.5 tWPST 0.4 0.6 0.4 0.6 0.4 0.6 Active to Read with Auto precharge command tRAP 16 - 15 - 18 - Autoprecharge write recovery + Precharge time tDAL (tWR/tCK) + (tRP/tCK) - (tWR/tCK) + (tRP/tCK) - (tWR/tCK) + (tRP/tCK) - tCK tPDEX 1 - 1 - 1 - tCK Power Down Exit 22 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 21.0 System Characteristics for DDR SDRAM The following specification parameters are required in systems using DDR400 and DDR333 devices to ensure proper system performance. these characteristics are for system simulation purposes and are guaranteed by design. Table 1 : Input Slew Rate for DQ, DQS, and DM AC CHARACTERISTICS DDR400 SYMBOL PARAMETER DQ/DM/DQS input slew rate measured between VIH(DC), VIL(DC) and VIL(DC), VIH(DC) DDR333 MIN MAX MIN MAX 0.5 4.0 0.5 4.0 DCSLEW Units Notes V/ns a, l Table 2 : Input Setup & Hold Time Derating for Slew Rate Input Slew Rate ∆tIS ∆tIH Units Notes 0.5 V/ns 0 0 ps i 0.4 V/ns +50 0 ps i 0.3 V/ns +100 0 ps i Table 3 : Input/Output Setup & Hold Time Derating for Slew Rate Input Slew Rate ∆tDS ∆tDH Units Notes 0.5 V/ns 0 0 ps k 0.4 V/ns +75 +75 ps k 0.3 V/ns +150 +150 ps k Table 4 : Input/Output Setup & Hold Derating for Rise/Fall Delta Slew Rate Delta Slew Rate ∆tDS ∆tDH Units Notes +/- 0.0 V/ns 0 0 ps j +/- 0.25 V/ns +50 +50 ps j +/- 0.5 V/ns +100 +100 ps j Table 5 : Output Slew Rate Characteristice (X4, X8 Devices only) Slew Rate Characteristic Typical Range (V/ns) Minimum (V/ns) Maximum (V/ns) Notes Pullup Slew Rate 1.2 ~ 2.5 1.0 4.5 a,c,d,f,g,h Pulldown slew 1.2 ~ 2.5 1.0 4.5 b,c,d,f,g,h Table 6 : Output Slew Rate Characteristice (X16 Devices only) Slew Rate Characteristic Typical Range (V/ns) Minimum (V/ns) Maximum (V/ns) Notes Pullup Slew Rate 1.2 ~ 2.5 0.7 5.0 a,c,d,f,g,h Pulldown slew 1.2 ~ 2.5 0.7 5.0 b,c,d,f,g,h Table 7 : Output Slew Rate Matching Ratio Characteristics AC CHARACTERISTICS DDR400 DDR333 PARAMETER MIN MAX MIN MAX Output Slew Rate Matching Ratio (Pullup to Pulldown) 0.67 1.5 0.67 1.5 23 of 32 Notes e, l Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 22.0 Component Notes 1. All voltages referenced to VSS. 2. Tests for ac timing, IDD, and electrical, ac and dc characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. 3. Figure 1 represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be either a precise representation of the typical system environment nor a depiction of the actual load presented by a production tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester electronics). VTT 50Ω Output (Vout) 30pF Figure 1 : Timing Reference Load 4. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5 V in the test environment, but input timing is still referenced to VREF (or to the crossing point for CK/CK), and parameter specifications are guaranteed for the specified ac input levels under normal use conditions. The minimum slew rate for the input signals is 1 V/ns in the range between VIL(AC) and VIH(AC). 5. The ac and dc input level specifications are as defined in the SSTL_2 Standard (i.e., the receiver will effectively switch as a result of the signal crossing the ac input level and will remain in that state as long as the signal does not ring back above (below) the dc input LOW (HIGH) level. 6. Inputs are not recognized as valid until VREF stabilizes. Exception: during the period before VREF stabilizes, CKE ≤ 0.2VDDQ is recognized as LOW. 7. Enables on.chip refresh and address counters. 8. IDD specifications are tested after the device is properly initialized. 9. The CK/CK input reference level (for timing referenced to CK/CK) is the point at which CK and CK cross; the input reference level for signals other than CK/CK, is VREF. 10. The output timing reference voltage level is VTT. 11. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to a specific voltage level but specify when the device output is no longer driving (HZ), or begins driving (LZ). 12. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but sys tem performance (bus turnaround) will degrade accordingly. 13. The specific requirement is that DQS be valid (HIGH, LOW, or at some point on a valid transition) on or before this CK edge. A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. when no writes were previ ously in progress on the bus, DQS will be transitioning from High- Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS. 14. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device. 15. For command/address input slew rate ≥ 1.0 V/ns 16. For command/address input slew rate ≥ 0.5 V/ns and < 1.0 V/ns 24 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Component Notes 17. For CK & CK slew rate ≥ 1.0 V/ns 18. These parameters guarantee device timing, but they are not necessarily tested on each device. They may be guaranteed by device design or tester correlation. 19. Slew Rate is measured between VOH(AC) and VOL(AC). 20. Min (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this value can be greater than the minimum specification limits for tCL and tCH).....For example, tCL and tCH are = 50% of the period, less the half period jitter (tJIT(HP)) of the clock source, and less the half period jitter due to crosstalk (tJIT(crosstalk)) into the clock traces. 21. tQH = tHP - tQHS, where: tHP = minimum half clock period for any given cycle and is defined by clock high or clock low (tCH, tCL). tQHS accounts for 1) The pulse duration distortion of on-chip clock circuits; and 2) The worst case push-out of DQS on one tansition followed by the worst case pull-in of DQ on the next transition, both of which are, separately, due to data pin skew and output pattern effects, and pchannel to n-channel variation of the output drivers. 22. tDQSQ Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers for any given cycle. 23. tDAL = (tWR/tCK) + (tRP/tCK) For each of the terms above, if not already an integer, round to the next highest integer. Example: For DDR400 at CL=3 and tCK=5ns tDAL = (15 ns / 5 ns) + (15 ns/ 5 ns) = (3) + (3) tDAL = 6 clocks 25 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 23.0 System Notes a. Pullup slew rate is characteristized under the test conditions as shown in Figure 2. Test point Output 50Ω VSSQ Figure 2 : Pullup slew rate test load b. Pulldown slew rate is measured under the test conditions shown in Figure 3. VDDQ 50Ω Output Test point Figure 3 : Pulldown slew rate test load c. Pullup slew rate is measured between (VDDQ/2 - 320 mV +/- 250 mV) Pulldown slew rate is measured between (VDDQ/2 + 320 mV +/- 250 mV) Pullup and Pulldown slew rate conditions are to be met for any pattern of data, including all outputs switching and only one output switching. Example : For typical slew rate, DQ0 is switching For minmum slew rate, all DQ bits are switching from either high to low, or low to high. The remaining DQ bits remain the same as for previous state. d. Evaluation conditions Typical : 25 °C (T Ambient), VDDQ = 2.5V, typical process Minimum : 70 °C (T Ambient), VDDQ = 2.3V, slow - slow process Maximum : 0 °C (T Ambient), VDDQ = 2.7V, fast - fast process e. The ratio of pullup slew rate to pulldown slew rate is specified for the same temperature and voltage, over the entire temperature and voltage range. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. f. Verified under typical conditions for qualification purposes. g. TSOPII package divices only. h. Only intended for operation up to 500 Mbps per pin. i. A derating factor will be used to increase tIS and tIH in the case where the input slew rate is below 0.5V/ns as shown in Table 2. The Input slew rate is based on the lesser of the slew rates detemined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions. j. A derating factor will be used to increase tDS and tDH in the case where DQ, DM, and DQS slew rates differ, as shown in Tables 3 & 4. Input slew rate is based on the larger of AC-AC delta rise, fall rate and DC-DC delta rise, Input slew rate is based on the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions. The delta rise/fall rate is calculated as: {1/(Slew Rate1)} - {1/(Slew Rate2)} For example : If Slew Rate 1 is 0.5 V/ns and slew Rate 2 is 0.4 V/ns, then the delta rise, fall rate is - 0.5ns/V . Using the table given, this would result in the need for an increase in tDS and tDH of 100 ps. k. Table 3 is used to increase tDS and tDH in the case where the I/O slew rate is below 0.5 V/ns. The I/O slew rate is based on the lesser on the lesser of the AC - AC slew rate and the DC- DC slew rate. The inut slew rate is based on the lesser of the slew rates deter mined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), and similarly for rising transitions. l. DQS, DM, and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transi tions through the DC region must be monotonic. 26 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 24.0 IBIS : I/V Characteristics for Input and Output Buffers DDR SDRAM Output Driver V-I Characteristics DDR SDRAM Output driver characteristics are defined for full and half strength operation as selected by the EMRS bit A1. Figures 4, 5 and 6 show the driver characteristics graphically, and tables 8, 9 and 10 show the same data in tabular format suitable for input into simulation tools. The driver characteristcs evaluation conditions are: Typical Minimum Maximum 25×C 70×C 0×C VDD/VDDQ = 2.5V, typical process VDD/VDDQ = 2.3V, slow-slow process VDD/VDDQ = 2.7V, fast-fast process Output Driver Characteristic Curves Notes: 1. The full variation in driver current from minimum to maximum process, temperature and voltage will lie within the outer bounding lines the of the V-I curve of Figures 4, 5 and 6. 2. It is recommended that the "typical" IBIS V-I curve lie within the inner bounding lines of the V-I curves of Figures 4, 5 and 6. 3. The full variation in the ratio of the "typical" IBIS pullup to "typical" IBIS pulldown current should be unity +/- 10%, for device drain to source voltages from 0.1 to1.0. This specification is a design objective only. It is not guaranteed. Iout(mA) 160 Maximum 140 120 Typical High 100 80 Typical Low 60 Minimum 40 20 0 0.0 0.5 1.0 1.5 2.0 2.5 Pull-down Characteristics for Full Strength Output Driver Vout(V) 0.0 1.0 2.0 0 Iout(mA) -20 Minumum -40 -60 Typical Low -80 -100 -120 -140 -160 -180 Typical High -200 Maximum -220 Pull-up Characteristics for Full Strength Output Driver Vout(V) Figure 4. I/V characteristics for input/output buffers:Pulldown(above) and pullup(below) 27 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Pull-down Current (mA) Voltage (V) Typical Typical Low High 0.1 6.0 0.2 Pull-up Current (mA) Typical Typical Low High 9.6 -6.1 9.2 18.2 20.1 13.8 26.6 18.4 29.8 33.0 0.6 34.6 0.7 0.8 Minimum Maximum Minimum Maximum 6.8 4.6 -7.6 -4.6 -10.0 12.2 13.5 -12.2 -14.5 -9.2 -20.0 0.3 18.1 0.4 24.1 26.0 -18.1 -21.2 -13.8 -29.8 33.9 -24.0 -27.7 -18.4 -38.8 0.5 23.0 41.8 -29.8 -34.1 -23.0 -46.8 39.1 27.7 49.4 -34.3 -40.5 -27.7 -54.4 39.4 44.2 32.2 56.8 -38.1 -46.9 -32.2 -61.8 43.7 49.8 36.8 63.2 -41.1 -53.1 -36.0 -69.5 0.9 47.5 55.2 39.6 69.9 -41.8 -59.4 -38.2 -77.3 1.0 51.3 60.3 42.6 76.3 -46.0 -65.5 -38.7 -85.2 1.1 54.1 65.2 44.8 82.5 -47.8 -71.6 -39.0 -93.0 1.2 56.2 69.9 46.2 88.3 -49.2 -77.6 -39.2 -100.6 1.3 57.9 74.2 47.1 93.8 -50.0 -83.6 -39.4 -108.1 1.4 59.3 78.4 47.4 99.1 -50.5 -89.7 -39.6 -115.5 1.5 60.1 82.3 47.7 103.8 -50.7 -95.5 -39.9 -123.0 1.6 60.5 85.9 48.0 108.4 -51.0 -101.3 -40.1 -130.4 1.7 61.0 89.1 48.4 112.1 -51.1 -107.1 -40.2 -136.7 1.8 61.5 92.2 48.9 115.9 -51.3 -112.4 -40.3 -144.2 1.9 62.0 95.3 49.1 119.6 -51.5 -118.7 -40.4 -150.5 2.0 62.5 97.2 49.4 123.3 -51.6 -124.0 -40.5 -156.9 2.1 62.9 99.1 49.6 126.5 -51.8 -129.3 -40.6 -163.2 2.2 63.3 100.9 49.8 129.5 -52.0 -134.6 -40.7 -169.6 2.3 63.8 101.9 49.9 132.4 -52.2 -139.9 -40.8 -176.0 2.4 64.1 102.8 50.0 135.0 -52.3 -145.2 -40.9 -181.3 2.5 64.6 103.8 50.2 137.3 -52.5 -150.5 -41.0 -187.6 2.6 64.8 104.6 50.4 139.2 -52.7 -155.3 -41.1 -192.9 2.7 65.0 105.4 50.5 140.8 -52.8 -160.1 -41.2 -198.2 Table 8. Full Strength Driver Characteristics 28 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 90 Maximum 80 70 Typical High 50 Iout(mA) Iout(mA) 60 40 Typical Low Minimum 30 20 10 0 0.0 1.0 2.0 Pull-down Characteristics for Weak Output Driver 0.0 1.0 Vout(V) 2.0 0 Iout(mA) -10 -20 Minumum Typical Low -30 -40 -50 -60 Typical High -70 -80 Maximum -90 Pull-up Characteristics for Weak Output Driver Vout(V) Figure 5. I/V characteristics for input/output buffers:Pulldown(above) and pullup(below) 29 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Pull-down Current (mA) Voltage (V) Typical Typical Low High 0.1 3.4 0.2 6.9 Pull-up Current (mA) Typical Typical Low High 5.0 -3.5 5.2 9.9 -6.9 Minimum Maximum 3.8 2.6 7.6 Minimum Maximum -4.3 -2.6 -5.0 -8.2 -5.2 -9.9 0.3 10.3 11.4 7.8 14.6 -10.3 -12.0 -7.8 -14.6 0.4 13.6 15.1 10.4 19.2 -13.6 -15.7 -10.4 -19.2 0.5 16.9 18.7 13.0 23.6 -16.9 -19.3 -13.0 -23.6 0.6 19.6 22.1 15.7 28.0 -19.4 -22.9 -15.7 -28.0 0.7 22.3 25.0 18.2 32.2 -21.5 -26.5 -18.2 -32.2 0.8 24.7 28.2 20.8 35.8 -23.3 -30.1 -20.4 -35.8 0.9 26.9 31.3 22.4 39.5 -24.8 -33.6 -21.6 -39.5 1.0 29.0 34.1 24.1 43.2 -26.0 -37.1 -21.9 -43.2 1.1 30.6 36.9 25.4 46.7 -27.1 -40.3 -22.1 -46.7 1.2 31.8 39.5 26.2 50.0 -27.8 -43.1 -22.2 -50.0 1.3 32.8 42.0 26.6 53.1 -28.3 -45.8 -22.3 -53.1 1.4 33.5 44.4 26.8 56.1 -28.6 -48.4 -22.4 -56.1 1.5 34.0 46.6 27.0 58.7 -28.7 -50.7 -22.6 -58.7 1.6 34.3 48.6 27.2 61.4 -28.9 -52.9 -22.7 -61.4 1.7 34.5 50.5 27.4 63.5 -28.9 -55.0 -22.7 -63.5 1.8 34.8 52.2 27.7 65.6 -29.0 -56.8 -22.8 -65.6 1.9 35.1 53.9 27.8 67.7 -29.2 -58.7 -22.9 -67.7 2.0 35.4 55.0 28.0 69.8 -29.2 -60.0 -22.9 -69.8 2.1 35.6 56.1 28.1 71.6 -29.3 -61.2 -23.0 -71.6 2.2 35.8 57.1 28.2 73.3 -29.5 -62.4 -23.0 -73.3 2.3 36.1 57.7 28.3 74.9 -29.5 -63.1 -23.1 -74.9 2.4 36.3 58.2 28.3 76.4 -29.6 -63.8 -23.2 -76.4 2.5 36.5 58.7 28.4 77.7 -29.7 -64.4 -23.2 -77.7 2.6 36.7 59.2 28.5 78.8 -29.8 -65.1 -23.3 -78.8 2.7 36.8 59.6 28.6 79.7 -29.9 -65.8 -23.3 -79.7 Table 9. Weak Driver Characteristics 30 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L 70 Maximum 60 Iout(mA) 50 40 30 Minimum 20 10 0 0.0 1.0 2.0 Pull-down Characteristics for Matched Output Driver 0.0 1.0 Vout(V) 2.0 0 Iout(mA) -10 Minumum -20 -30 -40 -50 Maximum -60 -70 Pull-up Characteristics for Matched Output Driver Vout(V) Figure 6. I/V characteristics for input/output buffers:Pulldown(above) and pullup(below) 31 of 32 Rev. 1.2 Feburary 2009 DDR SDRAM K4H281638L Pull-down Current(mA) pull-up Current (mA) Voltage (V) Minimum Maximum Minimum Maximum 0 0.0 0.0 0.0 0.0 0.2 3.6 7.8 -4.4 -8.8 0.4 7.3 15.8 -8.8 -15.7 0.6 11.0 23.1 -13.3 -23.0 0.8 14.6 29.4 -17.3 -29.4 1.0 16.8 35.5 -18.6 -35.4 1.2 18.3 41.0 -18.9 -41.0 1.4 18.8 46.1 -19.0 -46.0 1.6 19.0 50.5 -19.3 -50.3 1.8 19.6 53.8 -19.5 -53.8 2.0 19.7 57.3 -19.6 -57.2 2.2 19.8 60.1 -19.7 -60.1 Table 10. Matched Driver Characteristics 32 of 32 Rev. 1.2 Feburary 2009