KS8721BL/SL Micrel KS8721BL/SL 3.3V Single Power Supply 10/100BASE-TX/FX MII Physical Layer Transceiver Rev. 1.1 General Description Features Operating with a 2.5V core to meet low-voltage and lowpower requirements, the KS8721BL and KS8721SL are 10BASE-T/100BASE-TX/FX Physical Layer Transceivers that use MII and RMII interfaces to transmit and receive data. They contain 10BASE-T Physical Medium Attachment (PMA), Physical Medium Dependent (PMD), and Physical Coding Sub-layer (PCS) functions. The KS8721BL/SL also have onchip 10BASE-T output filtering. This eliminates the need for external filters and allows a single set of line magnetics to be used to meet requirements for both 100BASE-TX and 10BASE-T. The KS8721BL/SL automatically configures itself for 100 or 10Mbps and full- or half-duplex operation, using an on-chip auto-negotiation algorithm. It is the ideal physical layer transceiver for 100BASE-TX/10BASE-T applications. • Single chip 100BASE-TX/100BASE-FX/10BASE-T physical layer solution • 2.5V CMOS design; 2.5/3.3V tolerance on I/O • 3.3V single power supply with built-in voltage regulator; Power consumption <340mW (including output driver current) • Fully compliant to IEEE 802.3u standard • Supports MII and Reduced MII (RMII) • Supports 10BASE-T, 100BASE-TX, and 100BASE-FX with Far_End_Fault Detection • Supports power-down and power-saving modes • Configurable through MII serial management ports or via external control pins • Supports auto-negotiation and manual selection for 10/100Mbps speed and full-/half-duplex modes • On-chip, built-in, analog front-end filtering for both 100BASE-TX and 10BASE-T Functional Diagram TX+ TX- Transmitter 10/100 Pulse Shaper NRZ/NRZI MLT3 Encoder 4B/5B Encoder Scrambler Parallel/Serial TXD3 TXD2 TXD1 TXD0 TXER Parallel/Serial Manchester Encoder Adaptive EQ Base Line Wander Correction MLT3 Decoder NRZI/NRZ RX+ RX- Clock Recovery 4B/5B Decoder Descrambler Serial/Parallel MII/RMII Registers and Controller Interface Auto Negotiation Manchester Decoder Serial/Parallel 10BASE-T Receiver Power Down or Saving XI XO PLL PWRDWN TXC TXEN CRS COL MDIO MDC RXD3 RXD2 RXD1 RXD0 RXER RXDV RXC LINK LED Driver COL FDX SPD Micrel, Inc. • 1849 Fortune Drive • San Jose, CA 95131 • USA • tel + 1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com May 2004 1 M9999-051704 KS8721BL/SL Features Micrel Ordering Information (continued) Part Number • LED outputs for link, activity, full-/half-duplex, collision, and speed • Supports back-to-back, FX to TX for media converter applications • Supports MDI/MDI-X auto-crossover • KS8721BL is a drop-in replacement for the KS8721BT in the same footprint • KS8721SL is a drop-in replacement for the KS8721B in the same footprint • Commercial temperature range: 0°C to +70°C • Industrial temperature range: –40°C to +85°C • Available in 48-pin SSOP and LQFP M9999-051704 2 Temp. Range Package Lead Finish KS8721BL 0°C to +70°C 48-Pin LQFP Standard KS8721SL 0°C to +70°C 48-Pin SSOP Standard KS8721BLI –40°C to +85°C 48-Pin LQFP Standard KS8721SLI –40°C to +85°C 48-Pin SSOP Standard KSZ8721BL 0°C to +70°C 48-Pin LQFP Lead-Free KSZ8721SL 0°C to +70°C 48-Pin SSOP Lead-Free May 2004 KS8721BL/SL Micrel Revision History Revision Date Summary of Changes 0.90 1/12/04 Created. 1.0 3/06/04 Initial release. Change to new format. Add part-ordering information. Editorial changes on pin description, RMII, and media converter operation. Update circuit design, reset timing, thermal resistance, electrical characteristics, and strapping option circuit. 1.1 5/17/04 Added BLI product information. May 2004 3 M9999-051704 KS8721BL/SL Micrel Table Of Contents Pin Description ............................................................................................................................................................ 6 Strapping Option ......................................................................................................................................................... 9 Pin Configuration ...................................................................................................................................................... 10 Introduction ........................................................................................................................................................... 11 100BASE-TX Transmit ........................................................................................................................................ 11 100BASE-TX Receive ......................................................................................................................................... 11 PLL Clock Synthesizer ......................................................................................................................................... 11 Scrambler/De-scrambler (100BASE-TX only) ..................................................................................................... 11 10BASE-T Transmit ............................................................................................................................................. 11 10BASE-T Receive .............................................................................................................................................. 11 SQE and Jabber Function (10BASE-T only) ....................................................................................................... 11 Auto-Negotiation .................................................................................................................................................. 11 MII Management Interface ................................................................................................................................... 12 MII Data Interface ................................................................................................................................................ 12 Transmit Clock ............................................................................................................................................. 12 Receive Clock .............................................................................................................................................. 12 Transmit Enable ........................................................................................................................................... 12 Receive Data Valid ...................................................................................................................................... 12 Error Signals ................................................................................................................................................ 12 Carrier Sense ............................................................................................................................................... 12 Collision ........................................................................................................................................................ 13 RMII (Reduced MII) Data Interface ..................................................................................................................... 13 RMII Signal Definition .......................................................................................................................................... 13 Reference Clock .................................................................................................................................................. 13 Carrier Sense/Receive Data Valid ....................................................................................................................... 13 Receive Data ....................................................................................................................................................... 13 Transmit Enable ................................................................................................................................................... 13 Transmit Data ...................................................................................................................................................... 14 Collision Detection ............................................................................................................................................... 14 RX_ER ........................................................................................................................................................... 14 RMII AC Characteristics ...................................................................................................................................... 14 Unused RMII Pins ................................................................................................................................................ 14 Auto-Crossover (Auto-MDI/MDI-X) ...................................................................................................................... 15 Power Management ............................................................................................................................................. 16 100BT FX Mode .................................................................................................................................................. 16 Media Converter Operation ................................................................................................................................. 16 Circuit Design Reference for Power Supply ........................................................................................................ 17 Register Map ........................................................................................................................................................... 18 Register 0h: Basic Control .................................................................................................................................. 18 Register 1h: Basic Status ................................................................................................................................... 18 Register 2h: PHY Identifier 1 .............................................................................................................................. 19 Register 3h: PHY Identifier 2 .............................................................................................................................. 19 Register 4h: Auto-Negotiation Advertisement ..................................................................................................... 19 Register 5h: Auto-Negotiation Link Partner Ability .............................................................................................. 19 Register 6h: Auto-Negotiation Expansion ........................................................................................................... 20 Register 7h: Auto-Negotiation Next Page ........................................................................................................... 20 Register 8h: Link Partner Next Page Ability ........................................................................................................ 20 M9999-051704 4 May 2004 KS8721BL/SL Micrel Register Map (continued) Register 15h: RXER Counter ...................................................................................................................................... Register 1bh: Interrupt Control/Status Register .......................................................................................................... Register 1fh: 100BASE-TX PHY Controller ................................................................................................................ Absolute Maximum Ratings ........................................................................................................................................ Operating Ratings ........................................................................................................................................................ Electrical Characteristics ............................................................................................................................................ Timing Diagrams .......................................................................................................................................................... Selection of Isolation Transformer ............................................................................................................................ Selection of Reference Crystal ................................................................................................................................... Package Information ................................................................................................................................................... 21 21 21 23 23 23 25 31 31 32 May 2004 5 M9999-051704 KS8721BL/SL Micrel Pin Description Pin Number Pin Name Type(1) 1 MDIO I/O 2 MDC I 3 RXD3/ PHYAD Ipd/O MII Receive Data Output. RXD [3..0], these bits are synchronous with RXCLK. When RXDV is asserted, RXD [3..0] presents valid data to MAC through the MII. RXD [3..0] is invalid when RXDV is de-asserted. During reset, the pull-up/pull-down value is latched as PHYADDR [1]. See “Strapping Options” section for details. 4 RXD2/ PHYAD2 Ipd/O MII Receive Data Output. During reset, the pull-up/pull-down value is latched as PHYADDR[2]. See “Strapping Options” section for details. 5 RXD1/ PHYAD3 Ipd/O MII Receive Data Output. During reset, the pull-up/pull-down value is latched as PHYADDR [3]. See “Strapping Options” section for details. 6 RXD0/ PHYAD4 Ipd/O MII Receive Data Output. During reset, the pull-up/pull-down value is latched as PHYADDR [4]. See “Strapping Options” section for details. 7 VDDIO P 8 GND GND Ground. 9 RXDV/ CRSDV/ PCS_LPBK Ipd/O MII Receive Data Valid Output. During reset, the pull-up/pull-down value is latched as PCS_LPBK. See “Strapping Options” section for details. 10 RXC O 11 RXER/ISO Ipd/O MII Receive Error Output. During reset, the pull-up/pull-down value is latched as ISOLATE during reset. See “Strapping Options” section for details. 12 GND GND Ground. 13 VDDC P 14 TXER Ipd MII Transmit Error Input. 15 TXC/ REFCLK I/O MII Transmit Clock Output. Input for crystal or an external 50MHz clock. When REFCLK pin is used for REF clock interface, pull up XI to VDDPLL 2.5V via 10kΩ resistor and leave XO pin unconnected. 16 TXEN Ipd MII Transmit Enable Input. 17 TXD0 Ipd MII Transmit Data Input. 18 TXD1 Ipd MII Transmit Data Input. Pin Function Management Independent Interface (MII) Data I/O. This pin requires an external 10K pull-up resistor. MII Clock Input. This pin is synchronous to the MDIO. Digital IO 2.5 /3.3V tolerant power supply. 3.3V power Input of voltage regulator. See “Circuit Design Ref. for Power Supply" section for details. MII Receive Clock Output. Operating at 25MHz = 100Mbps, 2.5MHz = 10Mbps. Digital core 2.5V only power supply. See “Circuit Design Ref. for Power Supply" section for details. Notes: 1. P = Power supply. GND = Ground. I = Input. I/O = Bidirectional. Ipd = Input w/ internal pull-down. Ipd/O = Input w/ internal pull-down during reset, output pin otherwise. Ipu = Input w/ internal pull-up. Ipu/O = Input w/ internal pull-up during reset, output pin otherwise. O = Output. M9999-051704 6 May 2004 KS8721BL/SL Micrel Pin Number Pin Name Type(1) 19 TXD2 Ipd MII Transmit Data Input. 20 TXD3 Ipd MII Transmit Data Input. 21 COL/RMII Ipd/O MII Collision Detect Output. During reset, the pull-up/pull-down value is latched as RMII select. See “Strapping Options” section for details. 22 CRS/ RMII_BTB Ipd/O MII Carrier Sense Output. During reset, the pull-up/pull-down value is latched as RMII back-to-back mode when RMII mode is selected. See “Strapping Options” section for details. 23 GND GND Ground. 24 VDDIO P Digital IO 2.5/3.3V tolerant power supply. 3.3V power input of voltage regulator. See “Circuit Design Ref. for Power Supply” section for details. 25 INT#/ PHYAD0 Ipu/O Management Interface (MII) Interrupt Out. Interrupt level set by Register 1f, bit 9. During reset, latched as PHYAD[0]. See “Strapping Options” section for details. 26 LED0/TEST Ipu/O Link/Activity LED Output. The external pull-down enable test mode and only used for the factory test. Active low. 27 28 29 30 LED1/ SPD100/ nFEF LED2/ LED3/ NWAYEN PD# Ipu/O Ipu/O Ipu/O Ipu Pin Function Link/Act Pin State LED Definition No Link H “Off” Link L “On” Act — “Toggle” PHYAD0 Speed LED Output. Latched as SPEED (Register 0, bit 13) during power-up/ reset. See “Strapping Options” section for details. Active low. Speed Pin State LED Definition 10BT H “Off” 100BT L “On” Full-duplex LED Output. Latched as DUPLEX (register 0h, bit 8) during power-up/ reset. See “Strapping DUPLEX Options” section for details. Active low. Duplex Pin State LED Definition Half H “Off” Full L “On” Collision LED Output. Latched as ANEG_EN (register 0h, bit 12) during power-up/ reset. See “Strapping Options” section for details. Collison Pin State LED Definition No Collision H “Off” Collision L “On” Power Down. 1 = Normal operation, 0 = Power-down. Active low. Notes: 1. P = Power supply. GND = Ground. I = Input. I/O = Bidirectional. Ipd = Input w/ internal pull-down. Ipd/O = Input w/ internal pull-down during reset, output pin otherwise. Ipu = Input w/ internal pull-up. Ipu/O = Input w/ internal pull-up during reset, output pin otherwise. O = Output. May 2004 7 M9999-051704 KS8721BL/SL Micrel Pin Number Pin Name Type(1) 31 VDDRX P Analog 2.5V power supply. See “Circuit Design Ref. for Power Supply” section for details. 32 RX- I Receive Input. Differential receive input pins for 100FX, 100BASE-TX, or 10BASE-T. 33 RX+ I Receive Input: Differential receive input pin for 100FX, 100BASE-TX, or 10BASE-T. 34 FXSD/FXEN Ipd/O Fiber Mode Enable / Signal Detect in Fiber Mode. If FXEN = 0, FX mode is disable. The default is “0”. See “100BT FX Mode” section for more details. 35 GND GND Ground. 36 GND GND Ground. 37 REXT I External resistor (6.49kW ) connects to REXT and GND. 38 VDDRCV P Analog 2.5V power supply. 2.5V power output of voltage regulator. See “Circuit Design Ref. for Power Supply” section for details. 39 GND GND 40 TX- O Transmit Outputs: Differential transmit output for 100FX, 100BASE-TX, or 10BASE-T. 41 TX+ O Transmit Outputs: Differential transmit output for 100FX, 100BASE-TX, or 10BASE-T. 42 VDDTX P Transmitter 2.5V power supply. See “Circuit Design Ref. for Power Supply” section for details. 43 GND GND Ground. 44 GND GND Ground. 45 XO O XTAL feedback: Used with XI for Xtal application. 46 XI I Crystal Oscillator Input: Input for a crystal or an external 25MHz clock. If an oscillator is used, XI connects to a 3.3V tolerant oscillator, and X2 is a noconnect. 47 VDDPLL P Analog PLL 2.5V power supply. See “Circuit Design Ref. for Power Supply” section for details. 48 RST# Ipu Pin Function Ground. Chip Reset. Active low, minimum of 50µs pulse is required. Notes: 1. P = Power supply. GND = Ground. I = Input. I/O = Bidirectional. Ipd = Input w/ internal pull-down. Ipd/O = Input w/ internal pull-down during reset, output pin otherwise. Ipu = Input w/ internal pull-up. Ipu/O = Input w/ internal pull-up during reset, output pin otherwise. O = Output. M9999-051704 8 May 2004 KS8721BL/SL Micrel Strapping Options(1) Pin Number Pin Name Type(2) 6,5, 4,3 PHYAD[4:1]/ RXD[0:3] Ipd/O 25 PHYAD0/ INT# Ipu/O 9 PCS_LPBK/ RXDV Ipd/O Enables PCS_LPBK mode at power-up/reset. PD (default) = Disable, PU = Enable. 11 ISO/RXER Ipd/O Enables ISOLATE mode at power-up/reset. PD (default) = Disable, PU = Enable. 21 RMII/COL Ipd/O Enables RMII mode at power-up/reset. PD (default) = Disable, PU = Enable. 22 RMII_BTB CRS Ipd/O Enable RMII back-to-back mode at power-up/reset. PD (default) = Disable, PU = Enable. 27 SPD100/ No FEF/ LED1 Ipu/O Latched into Register 0h bit 13 during power-up/reset. PD = 10Mbps, PU (default) = 100Mbps. If SPD100 is asserted during power-up/reset, this pin is also latched as the Speed Support in register 4h. (If FXEN is pulled up, the latched value 0 means no Far_End _Fault.) 28 DUPLEX/ LED2 Ipu/O Latched into Register 0h bit 8 during power-up/reset. PD = Half-duplex, PU (default) = Full-duplex. If Duplex is pulled up during reset, this pin is also latched as the Duplex support in register 4h. 29 NWAYEN/ LED3 Ipu/O Nway (auto-negotiation) Enable. Latched into Register 0h bit 12 during power-up/ reset. PD = Disable Auto-Negotiation, PU (default) = Enable Auto-Negotiation. 30 PD# Ipu Power-Down Enable. PU (default) = Normal operation, PD = Power-Down mode. Description PHY Address latched at power-up/reset. The default PHY address is 00001. Notes: 1. Strap-in is latched during power-up or reset. 2. Ipu = Input w/ internal pull-up. Ipd/O = Input w/ internal pull-down during reset, output pin otherwise. Ipu/O = Input w/ internal pull-up during reset, output pin otherwise. See “Reference Circuit” section for pull-up/pull-down and float information. May 2004 9 M9999-051704 KS8721BL/SL Micrel Pin Configuration MDIO 1 48 RST# MDC 2 47 VDDPLL R3D3/PHYAD1 3 46 XI RXD2/PHYAD2 4 45 XO RXD1/PHYAD3 5 44 GND RXD0/PHYAD4 6 43 GND 42 VDDTX GND 8 41 TX+ RXDV/PCS_LPBK 9 40 TX- RXC 10 RXER/ISO 11 GND 12 39 GND 38 VDDRCV 48 47 46 45 44 43 42 41 40 39 38 37 37 REXT VDDC 13 36 GND TXER 14 35 GND TXC/REF_CLK 15 RST# VDDPLL X1 X0 GND GND VDDTX TX+ TX— GND VDDRCV REXT VDDIO 7 MDIO MDC RXD3/PHYAD1 RXD2/PHYAD2 RXD1/PHYAD3 RXD0/PHYAD4 VDDIO GND RXDV/PCS_LPBK RXC RXER/ISO GND 34 FXSD/FXEN TXEN 16 33 RX+ TXD0 17 32 RX- TXD1 18 31 VDDRX TXD2 19 30 PD# TXD3 20 29 LED3/NWAYEN COL/RMII 21 28 LED2/DUPLEX 36 35 34 33 32 31 30 29 28 27 26 25 1 2 3 4 5 6 7 8 9 10 11 12 GND GND FXSD/FXEN RX+ RX— VDDRX PD# LED3/NWAYEN LED2/DUPLEX LED1/SPD100 LED0/TEST INT#/PHYAD0 CRS/RMII_BTB 22 GND 23 VDDIO 24 VDDC TXER TXC/REF_CLK TXEN TXD0 TXD1 TXD2 TXD3 COL/RMII CRS/RMII_BTB GND VDDIO 13 14 15 16 17 18 19 20 21 22 23 24 27 LED1/SPD100 26 LED0/TEST 25 INT#/PHYAD0 48-Pin LQFP (LQ) 48-Pin SSOP (SM) M9999-051704 10 May 2004 KS8721BL/SL Micrel Introduction 100BASE-TX Transmit The 100BASE-TX transmit function performs parallel to serial conversion, NRZ-to-NRZI conversion, and MLT-3 encoding and transmission. The circuitry starts with a parallel to serial conversion that converts the 25MHz, 4-bit nibbles into a 125MHz serial bit stream. The incoming data is clocked in at the positive edge of the TXC signal. The serialized data is further converted from NRZ to NRZI format, and then transmitted in MLT3 current output. The output current is set by an external 1% 6.49kΩ resistor for the 1:1 transformer ratio. Its typical rise/fall time of 4ns complies with the ANSI TP-PMD standard regarding amplitude balance, overshoot, and timing jitter. The wave-shaped 10BASE-T output driver is also incorporated into the 100BASE-TX driver. 100BASE-TX Receive The 100BASE-TX receive function performs adaptive equalization, DC restoration, MLT-3 to NRZI conversion, data and clock recovery, NRZI-to-NRZ conversion, and serial-to-parallel conversion. The receiving side starts with the equalization filter to compensate inter-symbol interference (ISI) over the twisted pair cable. Since the amplitude loss and phase distortion are a function of the length of the cable, the equalizer has to adjust its characteristic to optimize performance. In this design, the variable equalizer will make an initial estimation based on comparisons of incoming signal strength against some known cable characteristics, then tunes itself for optimization. This is an ongoing process and can self-adjust for environmental changes such as temperature variations. The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is used to compensate for the effects of base line wander and improve dynamic range. The differential data conversion circuit converts the MLT3 format back to NRZI. The slicing threshold is also adaptive. The clock recovery circuit extracts the 125MHz clock from the edges of the NRZI signal. This recovered clock is then used to convert the NRZI signal into the NRZ format. Finally, the NRZ serial data is converted to 4-bit parallel 4B nibbles. A synchronized 25MHz RXC is generated so that the 4B nibbles are clocked out at the negative edge of RCK25 and is valid for the receiver at the positive edge. When no valid data is present, the clock recovery circuit is locked to the 25MHz reference clock and both TXC and RXC clocks continue to run. PLL Clock Synthesizer The KS8721BL/SL generates 125MHz, 25MHz, and 20MHz clocks for system timing. An internal crystal oscillator circuit provides the reference clock for the synthesizer. Scrambler/De-scrambler (100BASE-TX only) The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce electromagnetic interference (EMI) and baseline wander. 10BASE-T Transmit When TXEN (transmit enable) goes high, data encoding and transmission begins. The KS8721BL/SL continues to encode and transmit data as long as TXEN remains high. The data transmission ends when TXEN goes low. The last transition occurs at the boundary of the bit cell if the last bit is zero, or at the center of the bit cell if the last bit is one. The output driver is incorporated into the 100BASE-T driver to allow transmission with the same magnetics. They are internally wave-shaped and preemphasized into outputs with a typical 2.5V amplitude. The harmonic contents are at least 27dB below the fundamental when driven by an all-ones, Manchester-encoded signal. 10BASE-T Receive On the receive side, input buffer and level detecting squelch circuits are employed. A differential input receiver circuit and a PLL performs the decoding function. The Manchester-encoded data stream is separated into clock signal and NRZ data. A squelch circuit rejects signals with levels less than 300mV or with short pulse widths in order to prevent noise at the RX+ or RX- input from falsely triggering the decoder. When the input exceeds the squelch limit, the PLL locks onto the incoming signal and the KS8721BL/SL decodes a data frame. This activates the carrier sense (CRS) and RXDV signals and makes the receive data (RXD) available. The receive clock is maintained active during idle periods in between data reception. SQE and Jabber Function (10BASE-T only) In 10BASE-T operation, a short pulse is put out on the COL pin after each packet is transmitted. This is required as a test of the 10BASE-T transmit/receive path and is called an SQE test. The 10BASE-T transmitter is disabled and COL goes high if TXEN is high for more than 20ms (Jabbering). If TXEN then goes low for more than 250ms, the 10BASE-T transmitter is reenabled and COL goes low. Auto-Negotiation The KS8721BL/SL performs auto-negotiation by hardware strapping option (pin 29) or software (Register 0.12). It automatically chooses its mode of operation by advertising its abilities and comparing them with those received from its link May 2004 11 M9999-051704 KS8721BL/SL Micrel partner whenever auto-negotiation is enabled. It can also be configured to advertise 100BASE-TX or 10BASE-T in either fullor half-duplex mode (please refer to “Auto-Negotiation”). Auto-negotiation is disabled in the FX mode. During auto-negotiation, the contents of Register 4, coded in fast link pulse (FLP), are sent to its link partner under the conditions of power-on, link-loss, or restart. At the same time, the KS8721BL/SL monitors incoming data to determine its mode of operation. The parallel detection circuit is enabled as soon as either 10BASE-T normal link pulse (NLP) or 100BASE-TX idle is detected. The operation mode is configured based on the following priority: Priority 1: 100BASE-TX, full-duplex Priority 2: 100BASE-TX, half-duplex Priority 3: 10BASE-T, full-duplex Priority 4: 10BASE-T, half-duplex When the KS8721BL/SL receives a burst of FLP from its link partner with three identical link code words (ignoring acknowledge bit), it will store these code words in Register 5 and wait for the next three identical code words. Once the KS8721BL/SL detects the second code words, it then configures itself according to the above-mentioned priority. In addition, the KS8721BL/SL also checks for 100BASE-TX idle or 10BASE-T NLP symbols. If either is detected, the KS8721BL/SL automatically configures to match the detected operating speed. MII Management Interface The KS8721BL/SL supports the IEEE 802.3 MII Management Interface, also known as the Management Data Input/Output (MDIO) Interface. This interface allows upper-layer devices to monitor and control the state of the KS8721BL/SL. The MDIO interface consists of the following: • A physical connection including a data line (MDIO), a clock line (MDC), and an optional interrupt line (INTRPT). • A specific protocol that runs across the above-mentioned physical connection that allows one controller to communicate with multiple KS8721BL/SL devices. Each KS8721BL/SL is assigned an MII address between 0 and 31 by the PHYAD inputs. • An internal addressable set of fourteen 16-bit MDIO registers. Registers [0:6] are required and their functions are specified by the IEEE 802.3 specifications. Additional registers are provided for expanded functionality. The INTPRT pin functions as a management data interrupt in the MII. An active Low or High in this pin indicates a status change on the KS8721BL/SL based on 1fh.9 level control. Register bits at 1bh[15:8] are the interrupt enable bits. Register bits at 1bh[7:0] are the interrupt condition bits. This interrupt is cleared by reading Register 1bh. MII Data Interface The data interface consists of separate channels for transmitting data from a 10/100 802.3 compliant Media Access Controller (MAC) to the KS8721BL/SL, and for receiving data from the line. Normal data transmission is implemented in 4B nibble mode (4-bit wide nibbles). Transmit Clock (TXC): The transmit clock is normally generated by the KS8721BL/SL from an external 25MHz reference source at the X1 input. The transmit data and control signals must always be synchronized to the TXC by the MAC. The KS8721BL/SL normally samples these signals on the rising edge of the TXC. Receive Clock (RXC): For 100BASE-TX links, the receive clock is continuously recovered from the line. If the link goes down, and auto-negotiation is disabled, the receive clock operates off the master input clock (X1 or TXC). For 10BASE-T links, the receive clock is recovered from the line while carrier is active, and operates from the master input clock when the line is idle. The KS8721BL/SL synchronizes the receive data and control signals on the falling edge of RXC in order to stabilize the signals at the rising edge of the clock with 10ns setup and hold times. Transmit Enable: The MAC must assert TXEN at the same time as the first nibble of the preamble, and de-assert TXEN after the last bit of the packet. Receive Data Valid: The KS8721BL/SL asserts RXDV when it receives a valid packet. Line operating speed and MII mode will determine timing changes in the following way: • For 100BASE-TX links with the MII in 4B mode, RXDV is asserted from the first nibble of the preamble to the last nibble of the data packet. • For 10BASE-T links, the entire preamble is truncated. RXDV is asserted with the first nibble of the SFD “5D” and remains asserted until the end of the packet. Error Signals: Whenever the KS8721BL/SL receives an error symbol from the network, it asserts RXER and drives “1110” (4B) on the RXD pins. When the MAC asserts TXER, the KS8721BL/SL will drive “H” symbols (a Transmit Error defined in the IEEE 802.3 4B/5B code group) out on the line to force signaling errors. Carrier Sense (CRS): For 100BASE-TX links, a start-of-stream delimiter, or /J/K symbol pair causes assertion of Carrier Sense (CRS). An end-of-stream delimiter, or /T/R symbol pair, causes de-assertion of CRS. The PMA layer will also de-assert CRS if IDLE symbols are received without /T/R, yet in this case RXER will be asserted for one clock cycle when CRS is deM9999-051704 12 May 2004 KS8721BL/SL Micrel asserted. For 10BASE-T links, CRS assertion is based on reception of valid preamble, and de-assertion on reception of an end-of-frame (EOF) marker. Collision: Whenever the line state is half-duplex and the transmitter and receiver are active at the same time, the KS8721BL/ SL asserts its collision signal, which is asynchronous to any clock. RMII (Reduced MII) Data Interface RMII interface specifies a low-pin count, Reduced Media Independent Interface (RMII) intended for use between Ethernet PHYs and Switch or Repeater ASICs. It is fully compliant with IEEE 802.3u [2]. This interface has the following characteristics: • It is capable of supporting 10Mbps and 100Mbps data rates. • A single clock reference is sourced from the MAC to PHY (or from an external source). • It provides independent 2-bit wide (di-bit) transmit and receive data paths. • It uses TTL signal levels compatible with common digital CMOS ASIC processes. RMII Signal Definition Signal Name Direction (w/respect to the PHY) Direction (w/respect to the MAC) REF_CLK Input Input or Output Synchronous clock reference for receive, transmit and control interface CRS_DV Output Input Carrier Sense/Receive Data Valid RXD[1:0] Output Input Receive Data TX_EN Input Output Transmit Enable TXD[1:0] Input Output Transmit Data RX_ER Output Input (Not Required) Receive Error Use Reference Clock (REF_CLK) REF_CLK is a continuous 50MHz clock that provides the timing reference for CRS_DV, RXD[1:0], TX_EN, TXD[1:0], and RX_E. REF_CLK is sourced by the MAC or an external source. Switch implementations may choose to provide REF_CLK as an input or an output depending on whether they provide a REF_CLK output or rely on an external clock distribution device. Each PHY device must have an input corresponding to this clock but may use a single clock input for multiple PHYs implemented on a single IC. Carrier Sense/Receive Data Valid (CRS_DV) CRS_DV is asserted asynchronously on detection of carrier due to the criteria relevant to the operating mode. That is, in 10BASE-T mode, when squelch is passed or in 100BASE-X mode when 2 noncontiguous zeroes in 10 bits are detected, the carrier is detected. Loss-of-carrier results in the de-assertion of CRS_DV synchronous to REF_CLK. As carrier criteria are met, CRS_DV remains continuously asserted from the first recovered di-bit of the frame through the final recovered di-bit and is negated prior to the first REF_CLK that follows the final di-bit. The data on RXD[1:0] is considered valid once CRS_DV is asserted. However, since the assertion of CRS_DV is asynchronous relative to REF_CLK, the data on RXD[1:0] remains as “00” until proper receive signal decoding takes place (see “Definition of RXD[1:0] Behavior”). Receive Data [1:0] (RXD[1:0]) RXD[1:0] transitions synchronously to REF_CLK. For each clock period in which CRS_DV is asserted, RXD[1:0] transfers two bits of recovered data from the PHY. In some cases (e.g., before data recovery or during error conditions), a predetermined value for RXD[1:0] is transferred instead of recovered data. RXD[1:0] remains as “00” to indicate idle when CRS_DV is deasserted. Values of RXD[1:0] other than “00” when CRS_DV is de-asserted are reserved for out-of-band signalling (to be defined). Values other than “00” on RXD[1:0] while CRS_DV is de-asserted are ignored by the MAC/repeater. Upon assertion of CRS_DV, the PHY ensures that RXD[1:0]=00 until proper receive decoding takes place. Transmit Enable (TX_EN) Transmit Enable TX_EN indicates that the MAC is presenting di-bits on TXD[1:0] on the RMII for transmission. TX_EN is asserted synchronously with the first nibble of the preamble and remains asserted while all transmitted di-bits are presented May 2004 13 M9999-051704 KS8721BL/SL Micrel to the RMII. TX_EN is negated prior to the first REF_CLK following the final di-bit of a frame. TX_EN transitions synchronously with respect to REF_CLK. Transmit Data [1:0] (TXD[1:0]) Transmit Data TXD[1:0] transitions synchronously with respect to REF_CLK. When TX_EN is asserted, TXD[1:0] are accepted for transmission by the PHY. TXD[1:0] remains as “00” to indicate idle when TX_EN is de-asserted. Values of TXD[1:0] other than “00” when TX_EN is de-asserted are reserved for out-of-band signalling (to be defined). Values other than “00” on TXD[1:0] while TX_EN is de-asserted are ignored by the PHY. Collision Detection Since the definition of CRS_DV and TX_EN both contain an accurate indication of the start of frame, the MAC reliably regenerates the COL signal of the MII by ANDing TX_EN and CRS_DV. During the IPG time following the successful transmission of a frame, the COL signal is asserted by some transceivers as a self-test. The Signal Quality Error (SQE) function is not supported by the reduced MII due to the lack of the COL signal. Historically, SQE was present to indicate that a transceiver located physically remote from the MAC was functioning. Since the reduced MII only supports chip-to-chip connections on a PCB, SQE functionality is not required. RX_ER The PHY provides RX_ER as an output according to the rules specified in IEEE 802.3u [2] (see Clause 24, Figure 24-11– Receive State Diagram). RX_ER is asserted for one or more REF_CLK periods to indicate that an error (e.g., a coding error or any error that a PHY is capable of detecting, and that may otherwise be undetectable by the MAC sublayer) is detected somewhere in the frame presently being transferred from the PHY. RX_ER transitions synchronously with respect to REF_CLK. While CRS_DV is de-asserted, RX_ER has no effect on the MAC. RMII AC Characteristics Symbol Parameter Min REF_CLK Frequency Typ Max 50 Unit MHz REF_CLK Duty Cycle 35 65 % tSU TXD[1:0], TX_EN, RXD[1:0], CRS_DV, RXER 4 ns tH TXD[1:0], TX_EN, RXD[1:0], CRS_DV, RXER Data Hold from REF_CLK Rising Edge 2 ns Unused RMII Pins Input Pins Output Pins M9999-051704 TXD[2:3] and TXER are pull-down to GND. RXD[2:3] and RXC are no connect. Note that the RMII pin needs to be pulled up to enable RMII mode. 14 May 2004 KS8721BL/SL Micrel Auto-Crossover (Auto-MDI/MDI-X) Automatic MDI/MDI-X configuration is intended to eliminate the need for crossover cables between similar devices. The assignment of pinouts for a 10/100 BASE-T crossover function cable is shown below. This feature eliminates the confusion in applications by allowing the use of both straight and crossover cables. This feature is controlled by register 1f:13. See “Register 1fh–100BASE-TX PHY Controller” section for details. 10/100 BASE-T Media Dependent Interface 10/100 BASE-T Media Dependent Interface 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Transmit Pair Receive Pair Receive Pair Transmit Pair Modular Connector (RJ45) Modular Connector (RJ45) NIC HUB (Repeater or Switch) Figure 1. Straight Through Cable 10/100 BASE-T Media Dependent Interface 10/100 BASE-T Media Dependent Interface 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Receive Pair Receive Pair Transmit Pair Transmit Pair Modular Connector (RJ45) Modular Connector (RJ45) HUB (Repeater or Switch) HUB (Repeater or Switch) Figure 2. Crossover Cable May 2004 15 M9999-051704 KS8721BL/SL Micrel Power Management The KS8721BL/SL offers the following modes for power management: • Power-Down Mode: This mode can be achieved by writing to Register 0.11 or pulling pin 30 PD# low. • Power-Saving Mode: This mode can be disabled by writing to Register 1fh.10. The KS8721BL/SL turns off everything except for the Energy Detect and PLL circuits when the cable is not installed. In other words, the KS8721BL/SL shuts down most of the internal circuits to save power if there is no link. Power-saving mode is in the most effective state when auto-negotiation mode is enabled. 100BT FX Mode Please contact your local field application engineer (FAE) for a reference schematic on fiber connection. 100BT FX mode is activated when FXSD/FXEN is higher than 0.6V (this pin has a default pull down). Under this mode, the auto-negotiation and auto-MDI-X features are disabled. In fiber operation, the FXSD pin should connect to the signal detect (SD) output of the fiber module. The internal threshold of FXSD is around 1/2 VDD ±50mV (1.25V ±0.05V). Above this level, the fiber signal is considered detected. The operation is summarized in the following table: FXSD/FXEN Condition Less than 0.6V 100TX mode Less than 1.25V, but greater than 0.6V FX mode No signal detected FEF generated Greater than 1.25 FX mode Signal detected Table 1. 100BT FX Mode To ensure proper operation, the swing of fiber module SD should cover the threshold variation. A resistive voltage divider is recommended to adjust the SD voltage range. Far End Fault (FEF), repetition of a special pattern which consists of 84-one and 1-zero, is generated under “FX mode with no signal detected.” The purpose of FEF is to notify the sender of a faulty link. When receiving an FEF, the LINK will go down to indicate a fault, even with fiber signal detected. The transmitter is not affected by receiving an FEF and still sends out its normal transmit pattern from MAC. FEF can be disabled by strapping pin 27 low. Refer to the “Strapping Options” section. Media Converter Operation The KS8721BL/SL is capable of performing media conversion with two parts in a back-to-back RMII loop-back mode as indicated in the diagram. Both parts are in RMII mode and with RMII BTB asserted (pins 21 and 22 strapped high). One part is operating in TX mode and the other is operating in FX mode. Both parts can share a common 50MHz oscillator. Under this operation, auto-negotiation on the TX side prohibits 10BASE-T link-up. Additional options can be implemented under this operation. Disable the transmitter and set it at tri-state by controlling the high TXD2 pin. In order to do this, RXD2 and TXD2 pins need to be connected via inverter. When TXD2 pin is high in both the copper and fiber operation, it is disabled transmit. Meanwhile, the RXD2 pin on the copper side serves as the energy detect and can indicate if a line signal is detected. TXD3 should be tied low and RXD3 let float. Please contact your Micrel FAE for a media converter reference design. VCC 21 22 Pin Rx +/- KS8721BL/SL RxD TxD Tx +/- TxC/ Ref_CLK OSC FTx KS8721BL/SL FRx 50MHz TxC/ Ref_CLK (Fiber Mode) Pin 34 TxD RxD Pin 21 22 To the SD pin of the Fiber Module VCC Figure 3. Fiber Module M9999-051704 16 May 2004 KS8721BL/SL Micrel Circuit Design Reference for Power Supply Micrel’s integrated built-in, voltage regulator technology and thoughtful implementation allows the user to save BOM cost on both existing and future designs with the use of the new KS8721BL/SL single supply, single port 10/100 Ethernet PHY. Ferrite Bead Ferrite Bead 10µF 13 10µF 10µF 10µF 47 VDDC 42 VDDPLL 31 10µF 38 VDDRCV 10µF 7 +2.5VA +2.5VPLL VDDRX +2.5V VDDTX +3.3V VDDI/O IN 24 OUT Voltage Regulator VDDI/O GND KS8721BL/SL 8 12 23 35 36 39 43 44 Figure 4. Circuit Design The circuit design in Figure 4 shows the power connections for the power supply: the 3.3V to VDDI/O is the only input power source and the 2.5V at VDDRCV, pin 38, is the output of the voltage regulator that needs to supply through the rest of the 2.5V VDD pins via the 2.5V power plane. The 2.5V VDD pins make the drop-in replacement with the existing KS8721B/BT part. Table 2 shows the drop-in replacement from the existing KS8721B/BT to the KS8721SL/BL. Please contact your local Micrel FAE for Application Note AN-117, “Dropin Replacement with KS8721BT.” 2.5V/3.3V Supply 3.3V Supply with Built-in Regulator Part Number Package Part Number KS8721B 48-SSOP KS8721SL Package 48-SSOP KS8721BT 48-TQFP KS8721BL 48-LQFP KS8721BI 48-SSOP KS8721SLI 48-SSOP Table 2. Drop-In Replacement May 2004 17 M9999-051704 KS8721BL/SL Micrel Register Map Register No. Description 0h Basic Control Register 1h Basic Status Register 2h PHY Identifier I 3h PHY Identifier II 4h Auto-Negotiation Advertisement Register 5h Auto-Negotiation Link Partner Ability Register 6h Auto-Negotiation Expansion Register 7h Auto-Negotiation Next Page Register 8h Link Partner Next Page Ability 15h RXER Counter Register 1bh Interrupt Control/Status Register 1fh 100BASE-TX PHY Control Register Address Name Description Mode(1) Default Register 0h - Basic Control 0.15 Reset 1 = software reset. Bit is self-clearing. RW/SC 0 0.14 Loop-Back 1 = loop-back mode; 0 = normal operation. RW 0 0.13 Speed Select (LSB) 1 = 100Mbps; 0 = 10Mbps. Ignored if Auto-Negotiation is enabled (0.12 = 1). RW Set by SPD100 0.12 Auto-Negotiation Enable 1 = enable auto-negotiation process (override 0.13 and 0.8). 0 = disable auto-negotiation process. RW Set by NWAYEN 0.11 Power Down 1 = power-down mode; 0 = normal operation. RW 0 0.10 Isolate 1 = electrical isolation of PHY from MII and TX+/TX-. 0 = normal operation. RW Set by ISO 0.9 Restart Auto-Negotiation 1 = restart auto-negotiation process. 0 = normal operation. Bit is self-clearing. RW/SC 0 0.8 Duplex Mode 1 = full-duplex; 0 = half-duplex. RW Set by DUPLEX 0.7 Collision Test 1 = enable COL test; 0 = disable COL test. RW 0 0.6:1 Reserved RO 0 0.0 Disable Transmitter 0 = enable transmitter. 1 = disable transmitter. R/W 0 Register 1h - Basic Status 1.15 100BASE-T4 1 = T4 capable; 0 = not T4 capable. RO 0 1.14 100BASE-TX Full-Duplex 1 = capable of 100BASE-X full-duplex. 0 = not capable of 100BASE-X full-duplex. RO 1 1.13 100BASE-TX Half-Duplex 1 = capable of 100BASE-X half-duplex. 0 = not capable of 100BASE-X half-duplex. RO 1 1.12 10BASE-T Full-Duplex 1 = 10Mbps with full-duplex. 0 = no 10Mbps with full-duplex capability. RO 1 1.11 10BASE-T Half-Duplex 1 = 10Mbps with half-duplex. 0 = no 10Mbps with half-duplex capability. RO 1 Note: 1. RW: Read/Write, RO: Read Only, SC: Self Clear, LH: Latch High, LL: Latch Low. Some of the default values are set by strap-in. See “Strapping Options.” M9999-051704 18 May 2004 KS8721BL/SL Micrel Mode(1) Default RO 0 1 = preamble suppression; 0 = normal preamble. RO 1 Auto-Negotiation Complete 1 = auto-negotiation process completed. 0 = auto-negotiation process not completed. RO 0 1.4 Remote Fault 1 = remote fault; 0 = no remote fault. RO/LH 0 1.3 Auto-Negotiation Ability 1 = capable to perform auto-negotiation. 0 = unable to perform auto-negotiation. RO 1 1.2 Link Status 1 = link is up; 0 = link is down. RO/LL 0 1.1 Jabber Detect 1 = jabber detected; 0 = jabber not detected. Default is low. RO/LH 0 1.0 Extended Capability 1 = supports extended capabilities registers. RO 1 Assigned to the 3rd through 18th bits of the organizationally. unique identifier (OUI). Micrel’s OUI is 0010A1 (hex). RO 0022h Address Name 1.10:7 Reserved 1.6 No Preamble 1.5 Description Register 2h - PHY Identifier 1 2.15:0 PHY ID Number Register 3h - PHY Identifier 2 3.15:10 PHY ID Number Assigned to the 19th through 24th bits of the organizationally unique identifier (OUI). Micrel’s OUI is 0010A1 (hex). RO 000101 3.9:4 Model Number Six bit manufacturer’s model number. RO 100001 3.3:0 Revision Number Four bit manufacturer’s model number. RO 1001 RW 0 RO 0 RW 0 RO 0 Register 4h - Auto-Negotiation Advertisement 4.15 Next Page 1 = next page capable; 0 = no next page capability. 4.14 Reserved 4.13 Remote Fault 4.12 : 11 Reserved 4.10 Pause 1 = pause function supported; 0 = no pause function. RW 0 4.9 100BASE-T4 1 = T4 capable; 0 = no T4 capability. RO 0 4.8 100BASE-TX Full-Duplex 1 = TX with full-duplex; 0 = no TX full-duplex capability. RW Set by SPD100 & DUPLEX 4.7 100BASE-TX 1 = TX capable; 0 = no TX capability. RW Set by SPD100 4.6 10BASE-T Full-Duplex 1 = 10Mbps with full-duplex. 0 = no 10Mbps full-duplex capability. RW Set by DUPLEX 4.5 10BASE-T 1 = 10Mbps capable; 0 = no 10Mbps capability. RW 1 4.4:0 Selector Field [00001] = IEEE 802.3. RW 00001 1 = remote fault supported; 0 = no remote fault. Register 5h - Auto-Negotiation Link Partner Ability 5.15 Next Page 1 = next page capable; 0 = no next page capability. RO 0 5.14 Acknowledge 1 = link code word received from partner. 0 = link code word not yet received. RO 0 5.13 Remote Fault 1 = remote fault detected; 0 = no remote fault. RO 0 5.12 Reserved RO 0 Note: 1. RW: Read/Write, RO: Read Only, SC: Self Clear, LH: Latch High, LL: Latch Low. Some of the default values are set by strap-in. See “Strapping Options.” May 2004 19 M9999-051704 KS8721BL/SL Micrel Address Name Description Mode(1) Default 5.11:10 Pause 5.10 5 .11 0 0 RO 0 No PAUSE 0 1 Asymmetric PAUSE (link partner) 1 0 Symmetric PAUSE 1 1 Symmetric & Asymmetric PAUSE (local device) 5.9 100 BASE-T4 1 = T4 capable; 0 = no T4 capability. RO 0 5.8 100BASE-TX Full-Duplex 1 = TX with full-duplex; 0 = no TX full-duplex capability. RO 0 5.7 100BASE-TX 1 = TX capable; 0 = no TX capability. RO 0 5.6 10BASE-T Full-Duplex 1 = 10Mbps with full-duplex. 0 = no 10Mbps full-duplex capability. RO 0 5.5 10BASE-T 1 = 10Mbps capable; 0 = no 10Mbps capability. RO 0 5.4:0 Selector Field [00001] = IEEE 802.3. RO 00001 RO 0 Register 6h - Auto-Negotiation Expansion 6.15:5 Reserved 6.4 Parallel Detection Fault 1 = fault detected by parallel detection. 0 = no fault detected by parallel detection. RO/LH 0 6.3 Link Partner Next Page Able 1 = link partner has next page capability. 0 = link partner does not have next page capability. RO 0 6.2 Next Page Able 1 = local device has next page capability. 0 = local device does not have next page capability. RO 1 6.1 Page Received 1 = new page received; 0 = new page not yet received. RO/LH 0 6.0 Link Partner Auto-Negotiation Able 1 = link partner has auto-negotiation capability. 0 = link partner does not have auto-negotiation capability. RO 0 RW 0 RO 0 Register 7h - Auto-Negotiation Next Page 7.15 Next Page 1 = additional next page(s) will follow; 0 = last page. 7.14 Reserved 7.13 Message Page 1 = message page; 0 = unformatted page. RW 1 7.12 Acknowledge 2 1 = will comply with message. 0 = cannot comply with message. RW 0 7.11 Toggle 1 = previous value of the transmitted link code word. equaled logic One; 0 = logic Zero. RO 0 7.10:0 Message Field 11-bit wide field to encode 2048 messages. RW 001 Register 8h - Link Partner Next Page Ability 8.15 Next Page 1 = additional next page(s) will follow; 0 = last page. RO 0 8.14 Acknowledge 1 = successful receipt of link word. 0 = no successful receipt of link word. RO 0 8.13 Message Page 1 = Message Page; 0 = unformatted page. RO 0 8.12 Acknowledge 2 1 = able to act on the information. 0 = not able to act on the information. RO 0 8.11 Toggle 1 = previous value of transmitted link code word equal to logic zero; 0 = previous value of transmitted link code word equal to logic one. RO 0 8.10:0 Message Field RO 0 Note: 1. RW: Read/Write, RO: Read Only, SC: Self Clear, LH: Latch High, LL: Latch Low. Some of the default values are set by strap-in. See “Strapping Options.” M9999-051704 20 May 2004 KS8721BL/SL Address Name Micrel Description Mode(1) Default RX Error counter for the RX_ER in each package. RO 0000 Register 15h - RXER Counter 15.15:0 RXER Counter Register 1bh - Interrupt Control/Status Register 1b.15 Jabber Interrupt Enable 1 = Enable jabber interrupt; 0 = Disable jabber interrupt. RW 0 1b.14 Receive Error Interrupt Enable 1 = Enable receive error interrupt. 0 = Disable receive error interrupt. RW 0 1b.13 Page Received Interrupt Enable 1 = Enable page received interrupt. 0 = Disable page received interrupt. RW 0 1b.12 Parallel Detect Fault Interrupt Enable 1 = Enable parallel detect fault interrupt. 0 = Disable parallel detect fault interrupt. RW 0 1b.11 Link Partner Acknowledge Interrupt Enable 1 = Enable link partner acknowledge interrupt. 0 = Disable link partner acknowledge interrupt. RW 0 1b.10 Link Down Interrupt Enable 1 = Enable link down interrupt. 0 = Disable link down interrupt. RW 0 1b.9 Remote Fault Interrupt Enable 1 = Enable remote fault interrupt. 0 = Disable remote fault interrupt. RW 0 1b.8 Link Up Interrupt Enable 1 = Enable link up interrupt. 0 = Disable link up interrupt. RW 0 1b.7 Jabber Interrupt 1 = Jabber interrupt occurred. 0 = Jabber interrupt has not occurred. RO 0 1b.6 Receive Error Interrupt 1 = Receive error occurred. 0 = Receive error has not occurred. RO 0 1b.5 Page Receive Interrupt 1 = Page receive occurred. 0 = Page receive has not occurred. RO 0 1b.4 Parallel Detect Fault Interrupt 1 = Parallel detect fault occurred. 0 = Parallel detect fault has not occurred. RO 0 1b.3 Link Partner Acknowledge Interrupt 1 = Link partner acknowledge occurred. 0 = Link partner acknowledge has not occurred. RO 0 1b.2 Link Down Interrupt 1 = Link down occurred. 0 = Link down has not occurred. RO 0 1b.1 Remote Fault Interrupt 1 = Remote fault occurred. 0 = Remote fault has not occurred. RO 0 1b.0 Link Up Interrupt 1 = Link up interrupt occurred. 0 = Link up interrupt has not occurred. RO 0 Register 1fh - 100BASE-TX PHY Controller 1f.15:14 Reserved 1f:13 Pairswap Disable 1 = Disable MDI/MDI-X; 0 = Enable MDI/MDI-X. R/W 0 1f.12 Energy Detect 1 = Presence of signal on RX+/RX- analog wire pair. 0 = No signal detected on RX+/RX-. RO 0 1f.11 Force Link 1 = Force link pass; 0 = Normal link operation. R/W 0 This bit bypasses the control logic and allow transmitter to send pattern even if there is no link. 1f.10 Power-Saving 1 = Enable power-saving; 0 = Disable. RW 1 1f.9 Interrupt Level 1 = Interrupt pin active high; 0 = Active low. RW 0 1f.8 Enable Jabber 1 = Enable jabber counter; 0 = Disable. RW 1 1f.7 Auto-Negotiation Complete 1 = Auto-negotiation complete; 0 = Not complete. RW 0 Note: 1. RW: Read/Write, RO: Read Only, SC: Self Clear, LH: Latch High, LL: Latch Low. Some of the default values are set by strap-in. See “Strapping Options.” May 2004 21 M9999-051704 KS8721BL/SL Micrel Address Name Description Mode(1) Default 1f.6 Enable Pause (Flow-Control Result) 1 = Flow control capable; 0 = No flow control. RO 0 1f.5 PHY Isolate 1 = PHY in isolate mode; 0 = Not isolated. RO 0 1f.4:2 Operation Mode Indication [000] = Still in auto-negotiation. [001] = 10BASE-T half-duplex. [010] = 100BASE-TX half-duplex. [011] = Default. [101] = 10BASE-T full-duplex. [110] = 100BASE-TX full-duplex. [111] = PHY/MII isolate. RO 0 1f.1 Enable SQE Test 1 = Enable SQE test; 0 = Disable. RW 0 1f.0 Disable Data Scrambling 1 = Disable scrambler; 0 = Enable. RW 0 Note: 1. RW: Read/Write, RO: Read Only, SC: Self Clear, LH: Latch High, LL: Latch Low. Some of the default values are set by strap-in. See “Strapping Options.” M9999-051704 22 May 2004 KS8721BL/SL Micrel Absolute Maximum Ratings(1) Operating Ratings(2) Storage Temperature (TS) ....................... –55°C to +150°C Supply Referenced to GND ........................ –0.5V to +4.0V All Pins ........................................................ –0.5V to +4.0V Supply Voltage (VDD_PLL, VDD_TX, VDD_RXC, VDD_RCV, VDDC) ........ +2.5V (VDDIO) ................................................................... +3.3V Ambient Temperature (TA) Commercial ................................................ 0°C to +70°C Industrial ................................................. –40°C to +85°C Package Thermal Resistance(3) LQFP (θJA) No Airflow ................................................... 83.56°C/W SSOP (θJA) No Airflow ................................................... 75.19°C/W Important: Please read the Notes at the bottom of the page. Electrical Characteristics(4) VDD = 3.3V ±10% Symbol Parameter Total Supply Current (including TX output driver Test Condition Min Typ Max Units current)(5) IDD1 Normal 100BASE-TX Including 40mA output current 103 mA IDD2 Normal 10BASE-T (independent of utilization) Including 90mA output current 146 mA IDD3 Power Saving Mode 1 Auto-negotiation is Enable 43 mA IDD5 Power Down Mode 4 mA TTL Inputs VIH Input High Voltage V 1/2VDD(I/O) +0.2 VIL Input Low Voltage IIN Input Current VIN = GND ~ VDD Output High Voltage IOH = –4mA –10 0.8 V 10 µA TTL Outputs VOH V 1/2VDD(I/O) +0.6 VOL Output Low Voltage |IOZ| Output Tri-State Leakage IOL = 4mA 0.4 V 10 µA 100BASE-TX Receive RIN RX+/RX– Differential Input Resistance Propagation Delay 8 from magnetics to RDTX 50 kΩ 110 ns 1.05 V 2 % 5 0.5 ns ns 100BASE-TX Transmit (measured differentially after 1:1 transformer) VO Peak Differential Output Voltage 50Ω from each output to VDD VIMB Output Voltage Imbalance 50Ω from each output to VDD tr, tt Rise/Fall Time Rise/Fall Time Imbalance 0.95 3 0 Notes: 1. Exceeding the absolute maximum rating(s) may cause permanent damage to the device. Operating at maximum conditions for extended periods may affect device reliability. 2. The device is not guaranteed to function outside its operating rating. Unused inputs must always be tied to an appropriate logic voltage level (Ground to VDD). 3. No HS (heat spreader) in package. 4. Specification for packaged product only. 5. There is 100% data transmission in full-duplex mode and a minimum IPG with a 130-meter cable. May 2004 23 M9999-051704 KS8721BL/SL Symbol Parameter Micrel Condition Min Typ Max Units ±0.5 ns 5 % 100BASE-TX Transmit (measured differentially after 1:1 transformer) Duty Cycle Distortion Overshoot VSET Reference Voltage of ISET Propagation Delay 0.75 from TDTX to magentics Jitters V 45 60 ns 0.7 1.4 ns(pp) 10BASE-TX Receive RIN RX+/RX– Differential Input Resistance VSQ Squelch Threshold 5MHz square wave 8 kW 400 mV 10BASE-TX Transmit (measured differentially after 1:1 transformer) VP tr, tt Peak Differential Output Voltage 50W from each output to VDD Jitters Added 50W from each output to VDD Rise/Fall Time 2.2 2.8 V ±3.5 ns 25 ns Clock Outputs X1, X2 Crystal Oscillator 25 MHZ RXC100 Receive Clock, 100TX 25 MHZ RXC10 Receive Clock, 10T 2.5 MHZ Receive Clock Jitters 3.0 ns(pp) TXC100 Transmit Clock, 100TX 25 MHZ TXC10 Transmit Clock, 10T 2.5 MHZ Transmit Clock Jitters 1.8 ns(pp) M9999-051704 24 May 2004 KS8721BL/SL Micrel Timing Diagrams tHD2 TXC tSU2 TXEN TXD[3:0] tHD1 tSU1 tCRS1 CRS tCRS2 TXP/TXM tLA T Valid Data SQE Timing TXC TXEN tSQE COL tSQEP Figure 4. 10BASE-T MII Transmit Timing Symbol Parameter Min Typ Max Units tSU1 TXD [3:0] Set-Up to TXC High 10 ns tSU2 TXEN Set-Up to TXC High 10 ns tHD1 TXD [3:0] Hold After TXC High 0 ns tHD2 TXEN Hold After TXC High 0 ns tCRS1 TXEN High to CRS Asserted Latency 4 BT(1) tCRS2 TXEN Low to CRS De-Asserted Latency 8 BT tLAT TXEN High to TXP/TXM Output (TX Latency) 4 BT tSQE COL (SQE) Delay After TXEN De-Asserted 2.5 µs tSQEP COL (SQE) Pulse Duration 1.0 µs Table 3. 10BASE-T MII Transmit Timing Parameters Note: 1. BT = bit time. 1BT = 1ns @ 100BT. May 2004 25 M9999-051704 KS8721BL/SL Micrel TXC tSU2 tHD2 TXEN tSU1 TXD[3:0], TXER tHD1 Data In tCRS2 tCRS1 CRS tLAT Symbol Out TX+/TX- Figure 5. 100BASE-T MII Transmit Timing Symbol Parameter Min Typ Max Units tSU1 TXD [3:0] Set-Up to TXC High 10 ns tSU2 TXEN Set-Up to TXC High 10 ns tHD1 TXD [3:0] Hold After TXC High 0 ns tHD2 TXER Hold After TXC High 0 ns tHD3 TXEN Hold After TXC High 0 ns tCRS1 TXEN High to CRS Asserted Latency 4 BT tCRS2 TXEN Low to CRS De-Asserted Latency 4 BT tLAT TXEN High to TX+/TX– Output (TX Latency) 7 BT Table 4. 100BASE-T MII Transmit Timing Parameters M9999-051704 26 May 2004 KS8721BL/SL Micrel RX+/RX- CRS Start of Stream End of Stream tCRS1 tCRS2 tRLAT RXDV RXD[3:0] RXER tSU tHD tWH RXC tWL tP Figure 6. 100BASE-T MII Receive Timing Symbol Parameter Min Typ Max 40 Units tP RXC Period tWL RXC Pulse Width 20 ns tWH RXC Pulse Width 20 ns tSU RXD [3:0], RXER, RXDV Set-Up to Rising Edge of RXC 20 ns tHD RXD [3:0], RXER, RXDV Hold from Rising Edge of RXC 20 ns tRLAT CRS to RXD Latency, 4B or 5B Aligned tCRS1 “Start of Stream” to CSR Asserted 140 ns tCRS2 “End of Stream” to CSR De-Asserted 170 ns 1 2 ns 3 BT Table 5. 100BASE-T MII Receive Timing Parameters May 2004 27 M9999-051704 KS8721BL/SL Micrel FLP Burst FLP Burst TX+/TX- tFLPW tBTB TX+/TX- Clock Pulse Data Pulse tPW tPW Clock Pulse Data Pulse tCTD tCTC Figure 7. Auto-Negotiation/Fast Link Pulse Timing Symbol Parameter tBTB FLP Burst to FLP Burst tFLPW FLP Burst Width tPW Min Typ Max Units 8 16 24 ms 2 ms Clock/Data Pulse Width 100 ns tCTD Clock Pulse to Data Pulse 69 µs tCTC Clock Pulse to Clock Pulse Number of Clock/Data Pulses per Burst 136 17 33 µs µs Table 6. Auto-Negotiation/Fast Link Pulse Timing M9999-051704 28 May 2004 KS8721BL/SL Micrel tP MDC tMD1 MDI O (Into Chip) tMD2 Valid Data Valid Data tMD3 MDI O (Out of Chip) Valid Data Figure 8. Serial Management Interface Timing Symbol Parameter Min Typ 400 Max Units tP MDC Period tMD1 MDIO Set-Up to MDC (MDIO as Input) 10 ns tMD2 MDIO Hold After MDC (MDIO as Input) 10 ns tMD3 MDC to MDIO Valid (MDIO as Output) 222 ns ns Table 7. Serial Management Interface Timing May 2004 29 M9999-051704 KS8721BL/SL Micrel Supply Voltage tsr RST_N Strap-In Value Figure 9. Reset Timing Symbol Parameter Min tsr Stable Supply Voltages to Reset High 50 Typ Max Units µs Table 8. Reset Timing Parameters Reference Circuit for Strapping Option Configuration Figure 10 shows the reference circuit for strapping option pins. 2.5V 220Ω Pull-Up 10kΩ LED pin KS8721BL/SL 2.5V 220Ω Pull-down LED pin KS8721BL/SL 1kΩ Reference circuits for unmanaged programming through LED ports. Figure 10. Reference Circuit, Strapping Option Pins M9999-051704 30 May 2004 KS8721BL/SL Micrel Selection of Isolation Transformer(1) One simple 1:1 isolation transformer is needed at the line interface. An isolation transformer with integrated common-mode choke is recommended for exceeding FCC requirements. The following table gives recommended transformer characteristics. Characteristic Value Test Condition Turns Ratio 1 CT : 1 CT Open-Circuit Inductance (min.) 350µH 100mV, 100kHz, 8mA Leakage Inductance (max.) 0.4µH 1MHz (min.) Inter-Winding Capacitance (max.) 12pF D.C. Resistance (max.) 0.9Ω Insertion Loss (max.) 1.0dB HIPOT (min.) 1500Vrms 0MHz to 65MHz Note: 1. The IEEE 802.3u standard for 100BASE-TX assumes a transformer loss of 0.5dB. For the transmit line transformer, insertion loss of up to 1.3dB can be compensated or by increasing the line drive current by means of reducing the ISET resistor value. Please select the transformer that supports auto-MDI/MDI-X. Selection of Reference Crystal An oscillator or crystal with the following typical characteristics is recommended. Characteristic Value Units Frequency 25.00000 MHz Frequency Tolerance (max.) ±100 ppm Load Capacitance (max.) 20 pF Series Resistance (max.) 25 Ω Single Port Magnetic Manufacturer Part Number Auto-MDI-X Number of Ports Pulse H1102 Yes 1 Bel Fuse S558-5999-U7 Yes 1 YCL PH163112 Yes 1 Transpower HB726 Yes 1 Delta LF8505 Yes 1 LanKom LF-H41S Yes 1 Table 9. Qualified Transformer List May 2004 31 M9999-051704 KS8721BL/SL Micrel Package Information 48-Pin SSOP (SM) M9999-051704 32 May 2004 KS8721BL/SL Micrel 48-Pin LQFP (LQ) MICREL, INC. 1849 FORTUNE DRIVE TEL + 1 (408) 944-0800 FAX SAN JOSE, CA 95131 + 1 (408) 474-1000 WEB USA http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2004 Micrel, Incorporated. May 2004 33 M9999-051704