PRODUCT SPECIFICATION DATE:07/31/2008 cosmo Power Photo TRIAC: ELECTRONICS CORPORATION KTLP3617S 61P46003 SHEET 1 OF 6 Photo Coupler for Power Photo TRIAC Output z Features 1. Compact dual-in-line package. 2. 600V peak blocking voltage. 3. Isolation voltage between input and output 5000Vrms. z Application: 1. 2. 3. 4. TRIAC Driver. Programmable Controllers. AC-Output Module. Solid State Relay. REV. 4 PRODUCT SPECIFICATION DATE:07/31/2008 cosmo 61P46003 Power Photo TRIAC: KTLP3617S ELECTRONICS CORPORATION SHEET 2 OF 6 REV. 4 z Outside dimension:Unit ( mm ) 3617 XXX Date Code Tolerance:±0.2mm z Schematic:Top View 1 8 2 3 4 ZC 6 5 1. Cathode 2. Anode 3. Cathode 4. Cathode 5. Gate 6. T1 8. T2 PRODUCT SPECIFICATION DATE:07/31/2008 61P46003 Power Photo TRIAC: cosmo ELECTRONICS CORPORATION KTLP3617S SHEET 3 OF 6 REV. 4 z Absolute Maximum Ratings Parameter Input Output Symbol Rating Unit Forward current IF 50 mA Peak forward current IFP 1 A Reverse voltage VR 6 V Off-State Output Terminal voltage VDRM 600 V On-State R.M.S. Current IT(RMS) 1.2 A Peak Nonrepetitive Surge Current ( 60Hz, Peak ) ITSM 10 A Isolation voltage ( AC, 1 minute ) Viso 5000 Vrms Operating temperature Topr -40 to +85 ℃ Storage temperature Tstg -40 to +125 ℃ Soldering temperature 10 second Tsol 260 ℃ z Electro-optical Characteristics Parameter Input Output Symbol Conditions Forward voltage VF IF = 10mA - 1.2 1.4 V Reverse current IR VR = 6V - - 10 μA Peak Blocking Current IDRM VDRM = Rated - - 100 μA On-State Voltage VTM IT = 1.2A - - 3 V Holding Current IH VD = 5V - - 25 mA dV/dt VDRM = (1/ 2 )‧Rated 600 1000 - V/μs VINH IF = Rated IFT - - 50 V IDRM2 IF = Rated IFT, Rated VDRM, Off State - 200 - μA Riso DC500V 5×1010 - - Ω IFT VD = 5V - - 10 mA Critical rate of rise of Off-state voltage Inhibit voltage ( MT1-MT2 Voltage above which device not trigger ) Transfer Leakage in Inhibited State characteristics Isolation resistance Minimum trigger current MIN. TYP. MAX. Unit PRODUCT SPECIFICATION DATE:07/31/2008 61P46003 Power Photo TRIAC: cosmo KTLP3617S ELECTRONICS CORPORATION SHEET 4 OF 6 IF vs. Ta IT vs. Ta On-State R.M.S. Current IT ( A ) 50 40 30 20 10 Trigger Current IFT ( mA ) 0 20 40 60 80 100 1.2 1.0 0.8 0.6 0.4 0.2 -20 0 20 40 60 80 100 Ambient Temperature Ta ( ℃ ) Ambient Temperature Ta ( ℃ ) IFP vs. Duty Ratio IF vs. VF 10000 Forward current IF ( mA ) Peak forward current IFP ( mA ) -20 Ta=25°C 1000 100 -3 -2 10 200 -1 10 10 1 Ta=75° 50° 100 50 25° 0° -25° 20 10 5 2 0 0.5 1.0 1.5 2.0 2.5 Duty ratio Forward voltage VF ( V ) IFT vs. Ta VINH vs. Ta Normalized To Ta=25°C 6.2 6.0 5.8 5.6 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 3.8 3.6 -40 -20 500 1 0 0 20 40 60 80 100 120 Ambient Temperature Ta ( ℃ ) Inhibit Voltage VINH ( V ) Forward current IF ( mA ) 60 9.5 9.0 8.5 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 -40 -20 3.0 Normalized To Ta=25°C 0 20 40 60 80 100 120 Ambient Temperature Ta ( ℃ ) REV. 4 PRODUCT SPECIFICATION DATE:07/31/2008 61P46003 Power Photo TRIAC: cosmo KTLP3617S ELECTRONICS CORPORATION SHEET 5 OF 6 On-State Current ITM ( A ) +1.2 IF=10mA,Ta=25°C +1.0 +0.8 +0.6 0 -0.6 -0.8 -1.0 -1.2 -1.5 -1.0 -0.5 0 IDRM vs. Ta Peak Blocking Current IDRM ( nA ) ITM vs. VTM IF=0,VDRM=Rated 1000 500 200 100 50 -40 -20 0 20 40 60 80 100 +0.5 +1.0 +1.5 On-State Voltage VTM ( V ) Ambient Temperature Ta ( ℃ ) REV. 4 PRODUCT SPECIFICATION DATE:07/31/2008 cosmo ELECTRONICS CORPORATION 61P46003 Power Photo TRIAC: KTLP3617S SHEET 6 OF 6 z NOTICE The information contained in this document is intended to be a general product description and is subject to change without notice. Please contact cosmo in order to obtain the latest device data sheets before using any cosmo device. cosmo does not assume any responsibility for use of any circuitry described. No circuit patent licenses are implied. This publication is the property of cosmo. No part of this publication may be reproduced or copied in any form or by any means, or transferred to any third party without the prior written consent of cosmo Electronics Corporation. The devices listed in this document are designed for general applications only in electronic equipment. No devices shall be deployed which require higher level of reliability such as: – – – – Medical and other life support equipments. Space application. Telecommunication equipment ( trunk lines ). Nuclear power control equipment. Unless it received prior written approval from cosmo. cosmo takes no responsibility for damages arise form the improper usage of our device. Please contact cosmo for further information regarding the above notices. REV. 4