LIGITEK LA79B-1-GXGX-S2-PF

LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
LED ARRAY
Pb
Lead-Free Parts
LA79B-1/GXGX-S2-PF
DATA SHEET
DOC. NO :
QW0905-LA79B-1/GXGX-S2-PF
REV.
:
A
DATE
: 15 - Feb. - 2006
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
PART NO. LA79B-1/GXGX-S2-PF
Page 1/5
Package Dimensions
4.0±0.5
10.7
4.4
ψ2.9x2
G
X
20.3
G
1.5mm
5.08
X
2.5
3.5±0.5
0.5
TYP
4.7±0.5
2.54TYP
+ +
8.5±0.5
-
LG2640/S36-PF
2.9
3.1
3.3
1.5
MAX
□0.5
TYP
28.5MIN
4.3
29.5MIN
2.54TYP
+ Note : 1.All dimension are in millimeter tolerance is ±0.25mm unless otherwise noted.
2.Specifications are subject to change without notice.
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
Page 2/5
PART NO. LA79B-1/GXGX-S2-PF
Absolute Maximum Ratings at Ta=25 ℃
Ratings
Parameter
Symbol
UNIT
G
Forward Current
IF
30
mA
Peak Forward Current
Duty 1/10@10KHz
IFP
120
mA
Power Dissipation
PD
100
mW
Reverse Current @5V
Ir
10
μA
Operating Temperature
Topr
-40 ~ +85
℃
Storage Temperature
Tstg
-40 ~ +100
℃
Typical Electrical & Optical Characteristics (Ta=25 ℃)
PART NO
MATERIAL
COLOR
Emitted
LA79B-1/GXGX-S2-PF
GaP
Peak
wave
length
λPnm
Lens
Green Green Diffused
Forward
voltage
@20mA(V)
Spectral
halfwidth
△λ nm
Min.
565
30
1.7
Note : 1.The forward voltage data did not including ± 0.1V testing tolerance.
2. The luminous intensity data did not including ±15% testing tolerance.
Luminous Viewing
intensity
angle
@10mA(mcd) 2θ 1/2
(deg)
Max. Min. Typ.
2.6
12
20
50
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
PART NO. LA79B-1/GXGX-S2-PF
Page 3/5
Typical Electro-Optical Characteristics Curve
G CHIP
Fig.1 Forward current vs. Forward Voltage
Fig.2 Relative Intensity vs. Forward Current
3.5
Relative Intensity
Normalize @20mA
Forward Current(mA)
1000
100
10
1.0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0.1
1.0
2.0
3.0
4.0
5.0
1.0
10
1.2
1.1
1.0
0.9
0.8
0
20
40
60
80
100
Fig.5 Relative Intensity vs. Wavelength
1.0
0.5
0.0
500
550
600
Wavelength (nm)
3.0
2.5
2.0
1.5
1.0
0.5
0.0
-40
-20
0
20
40
60
Ambient Temperature( ℃)
Ambient Temperature( ℃)
Relative Intensity@20mA
Fig.4 Relative Intensity vs. Temperature
Relative Intensity@20mA
Normalize @25℃
Forward Voltage@20mA
Normalize @25℃
Fig.3 Forward Voltage vs. Temperature
-20
1000
Forward Current(mA)
Forward Voltage(V)
-40
100
650
80
100
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
PART NO. LA79B-1/GXGX-S2-PF
Page 4/5
Soldering Condition(Pb-Free)
1.Iron:
Soldering Iron:30W Max
Temperature 350° C Max
Soldering Time:3 Seconds Max(One Time)
Distance:2mm Min(From solder joint to case)
2.Wave Soldering Profile
Dip Soldering
Preheat: 120° C Max
Preheat time: 60seconds Max
Ramp-up
2°C/sec(max)
Ramp-Down:-5° C/sec(max)
Solder Bath:260°C Max
Dipping Time:3 seconds Max
Distance:2mm Min(From solder joint to case)
Temp(° C)
260° C3sec Max
260°
5° /sec
max
120°
25°
0°
2° /sec
max
0
Preheat
60 Seconds Max
50
100
150
Time(sec)
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
Page 5/5
PART NO. LA79B-1/GXGX-S2-PF
Reliability Test:
Test Item
Test Condition
Description
Reference
Standard
Operating Life Test
1.Under Room Temperature
2.If=20mA
3.t=1000 hrs (-24hrs, +72hrs)
This test is conducted for the purpose
of detemining the resistance of a part
in electrical and themal stressed.
MIL-STD-750: 1026
MIL-STD-883: 1005
JIS C 7021: B-1
High Temperature
Storage Test
1.Ta=105 ℃±5 ℃
2.t=1000 hrs (-24hrs, +72hrs)
The purpose of this is the resistance of
the device which is laid under condition
of high temperature for hours.
MIL-STD-883:1008
JIS C 7021: B-10
Low Temperature
Storage Test
1.Ta=-40 ℃±5℃
2.t=1000 hrs (-24hrs, +72hrs)
The purpose of this is the resistance
of the device which is laid under
condition of low temperature for hours.
High Temperature
High Humidity Test
1.Ta=65 ℃±5℃
2.RH=90 %~95 %
3.t=240hrs ±2hrs
The purpose of this test is the resistance
of the device under tropical for hours.
1.Ta=105 ℃±5℃&-40 ℃±5℃
(10min) (10min)
2.total 10 cycles
The purpose of this is the resistance of
the device to sudden extreme changes
in high and low temperature.
MIL-STD-202: 107D
MIL-STD-750: 1051
MIL-STD-883: 1011
Solder Resistance
Test
1.T.Sol=260 ℃±5℃
2.Dwell time= 10 ±1sec.
This test intended to determine the
thermal characteristic resistance
of the device to sudden exposures
at extreme changes in temperature
when soldering the lead wire.
MIL-STD-202: 210A
MIL-STD-750: 2031
JIS C 7021: A-1
Solderability Test
1.T.Sol=230 ℃±5℃
2.Dwell time=5 ±1sec
This test intended to see soldering well
performed or not.
MIL-STD-202: 208D
MIL-STD-750: 2026
MIL-STD-883: 2003
JIS C 7021: A-2
Thermal Shock Test
JIS C 7021: B-12
MIL-STD-202:103B
JIS C 7021: B-11