LINKCOM LAL2021-50

LAL2021-50
Broadband Access Transformer
z
z
z
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
RoHS Compliant
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
Leakage
Inductance:
Interwinding
Capacitance
PIN 16-9= 100uH ±5% @ 10KHz/0.1V/Ser. (PIN 11-14 Short)
PIN 16-9= 3.5uH Max. @ 100KHz/0.1V (PIN 1-2-3-4-5-6-7-8,11-14 Short)
PIN 1-16= 50 pF Max. @ 100KHz/0.1V
(PIN 1-2-3-4-5-6-7-8,PIN 11-14 Short)
PIN 1-4 to PIN 16-9= -85dB Max. @ 100KHz/4V (PIN 2-3,PIN 11-14 Short)
T.H.D
PIN 5-8 to PIN 16-9= -85dB Max. @ 100KHz/4V (PIN 6-7,PIN 11-14 Short)
D.C.R
PIN 1-4 = 0.840 ohm Max.
(PIN 2-3 Short)
PIN 5-8 = 0.250 ohm Max.
(PIN 6-7 Short)
PIN 16 -9 = 0.420 ohm Max.
Hi-POT :
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1 ( PIN 11-14,PIN 2-3 Short)
Turn Ratio:
PIN16-9 : PIN 5-8 = 4.25±2% :1 ( PIN 11-14,PIN 6-7 Short)
Dimensions (Units: mm)
Schematic
Mark
LALXXXX
LinkCom
1.LAL****----LAL2021
X Date Code G
2. X----PRODUCT LINE
3. DATE CODE----YYWW
DOT PIN1
SUGGESTED PADS LAYOUT
Rev.B
(PIN 11-14 Short)
4. G----RoHS