NKK LB26WKG01-EJ Standard size panel seal pushbutton Datasheet

Standard Size Panel Seal Pushbuttons
Series LB
Distinctive Characteristics
Square, round, rectangular, and round panel seal models
available.
Stainless steel clips provide secure mounting with a wide
range of panel thicknesses.
Latchdown feature gives indication of circuit status.
Audible and tactile feedback with smooth and
responsive operation.
Snap-action contact mechanism gives long electrical
life and sensitivity of actuation.
Combination solder lug and .110” quick connect
terminals are epoxy sealed to prevent entry of flux,
dust, and other contaminants.
Panel sealed model meets IP65 of IEC60529 specifications
(similar to NEMA 4 & 13).
Compact switch design minimizes behind panel depth.
Matching illuminated models available and shown in the
Illuminated Pushbutton section.
Matching indicators available and shown at the end of Section M.
Actual Size
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Standard Size Panel Seal Pushbuttons
Series LB
General Specifications
Electrical Capacity (Resistive Load)
Power Level (silver):
Logic Level (gold):
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Contact Timing:
Travel:
Materials & Finishes
Housing:
O-ring:
Inner Seal:
Movable Contact:
Stationary Contacts:
Base:
Terminals:
Environmental Data
Operating Temp Range:
Humidity:
Vibration:
Shock:
Sealing:
Installation
Mounting Torque:
Cap Installation Force:
Quick Connect Force:
Soldering Time & Temperature:
Standards & Certifications
Flammability Standards:
UL & C-UL Recognized:
R
CSA Certified:
3A @ 125V AC or 3A @ 250V AC
0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
50 milliohms maximum for silver; 100 milliohms maximum for gold
200 megohms minimum @ 500V DC
1,000V AC minimum between contacts for 1 minute minimum;
1,500V AC minimum between contacts & case for 1 minute minimum
1,000,000 operations minimum for momentary circuit
200,000 operations minimum for maintained circuit
100,000 operations minimum
5.39N
Nonshorting (break-before-make)
Momentary: Pretravel .059” (1.5mm); Overtravel .059” (1.5mm); Total Travel .118” (3.0mm)
Maintained: Pretravel .087” (2.2mm); Overtravel .031” (0.8mm); Total Travel .118” (3.0mm)
Glass fiber reinforced polyamide (UL94V-0)
Nitrile butadiene rubber
Silicone rubber
Silver alloy or copper with gold plating
Silver alloy or copper with gold plating
Liquid crystal polymer (UL94V-0)
Phosphor bronze with silver or gold plating
–25°C through +70°C (–13°F through +158°F)
Note: When used with a polyvinyl chloride splash cover, the lowest limit is 0°C (32°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning in
1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
IP65 of IEC60529 standard (similar to NEMA 4 & 13)
1.96Nm (17.35 lb•in) maximum
3.92N maximum downward force on cap
52.95N maximum downward force on connector
Manual Soldering: See Profile A in Supplement section.
UL94V-0 housing & base
All models recognized at 3A @ 125V or 250V AC or 0.4VA @ 28V AC/DC maximum;
UL File No. WOYR2.E44145; add “/U” to end of part number to order UL mark on switch;
C-UL File No. WOYR8.E44145; add “/C-UL” to end of part number to order C-UL mark on switch.
All models certified at 3A @ 125V or 250V AC or 0.4VA @ 28V AC/DC maximum;
CSA File Nos. 023535-0-000; add “/C” to end of part number to order CSA mark on switch.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Standard Size Panel Seal Pushbuttons
Series LB
TYPICAL SWITCH ORDERING EXAMPLE
LB
6
1
POLES
W
K
SPDT
2
DPDT
W
CJ
CONTACTS & TERMINALS
SHAPE
1
W01
Round
W01
Silver Contacts
Rated 3A @ 125/250V AC and
Solder Lug/Quick Connect Terminals
G01
Gold Contacts
Rated 0.4VA @ 28V AC/DC and
Solder Lug/Quick Connect Terminals
CIRCUITS
5
ON
(ON)
( ) = Momentary
6
ON
CAP COLORS
HOUSING
ON
Alternate Action
with Latchdown
K
Black
BJ
White
G
Gray
CJ
Red
EJ
Yellow
FJ
Green
GJ
Blue
IMPORTANT:
Note: Insert Cap with clear
lens and colored filter
available; see
Illuminated
Pushbuttons section
Switches are supplied without UL,
C-UL & CSA markings unless specified. Specific models & ratings noted
on General Specifications page.
DESCRIPTION FOR TYPICAL ORDERING EXAMPLE
LB16WKW01-CJ
Red Cap
Round Shape
Black Housing
SPDT
ON-ON Circuit
Silver Contacts
Rated 3A @ 125/250V AC;
Solder Lug/Quick Connect Terminals
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Standard Size Panel Seal Pushbuttons
Series LB
POLES & CIRCUITS
Plunger Position
( ) = Momentary
Pole
Connected Terminals
Normal
Down
Normal
Down
Throw & Switch/Lamp Schematics
Note:
Model
SP
LB15
*LB16
ON
ON
(ON)
ON
1-3
1-2
SPDT
DP
LB25
*LB26
ON
ON
(ON)
ON
1-3 4-6
1-2 4-5
DPDT
Switch is marked with NC, NO, COM, L+, L–.
3
1
3
1
COM
NC
2
COM
NC 2
NO
6
L (+)
(-) L
L (+)
(-) L
NO
4
COM
NC
5
NO
* When in latchdown position for the alternate circuit, cap position is .039” (1.0mm) above the built-in bezel.
SHAPE & PANEL CUTOUT
W
.866” (22.0mm)
Round
(1.7)
.067
Recommended Panel Thickness:
.039” ~ .157” (1 ~ 4mm)
Recommended Panel Thickness
with Splash Cover:
.039” ~ .138” (1 ~ 3.5mm)
Overtightening the mounting nut AT074
may damage the switch housing.
(10.5)
.413
(22.0) Dia
.866
HOUSING
K
Housing Colors Available:
G
Black
Gray
CONTACT MATERIALS, RATINGS & TERMINALS
W01
G01
Silver Contacts
Power Level
3A @ 125V AC & 250V AC
Gold Contacts
Logic Level
0.4VA max. @ 28V AC/DC max.
Solder Lug/Quick Connect
Epoxy
Seal
(2.0)
.079
(7.5)
.295
(2.8)
.110
(1.2)
.047
Thk = (0.5)
.020
Complete explanation of operating range in Supplement section.
CAP COLORS
Lens/Filter
Colors Available:
BJ
CJ
White
Red
(19.0) Dia
.748
EJ
FJ
Yellow
GJ
Blue
AT4054
(5.1)
.201
Green
Material: Polycarbonate
Finish: Glossy
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Standard Size Panel Seal Pushbuttons
Series LB
TYPICAL SWITCH DIMENSIONS
Panel Seal
Single & Double Pole
(5.5)
.217
(1.2) x (2.0) Typ
.047 x .079
M22 P1
(0.5) Typ
.020
NC
3
NO
COM
1
(1.8)
.071
(1.0)
.039
(3.2)
.126
6
(15.8) Sq
.622
5
2
(2.54) Typ
.100
(19.0) Dia
.748
(25.0) Dia
.984
L (+)
4
L (-)
Keyway
(12.0)
.472
(21.5)
.846
Latchdown Position
(2.8) Typ
.110
(7.5)
.295
LB25WKW01-CJ
(5.08) Typ
.200
Single pole models do not have terminals 4, 5, & 6.
OPTIONAL ACCESSORIES
PCB Adaptors
AT711
Single Pole • Straight PC Terminals
(0.3) Typ
.012
NC
NO
COM
(0.5)
.020
(15.0)
(4.0)
.591
.157
(+)
L
(-)
NO
(15.8) Sq
.622
COM
(2.54) Typ
.100
(0.74) Typ
.029
Double Pole • Straight PC Terminals
(0.3) Typ
.012
(5.08)
.200
NC
L
AT712
NO
(2.54) Typ
.100
(1.0) Dia Typ
.039
(5.08)
.200
COM
(0.5)
.020
(15.0)
(4.0)
.591
.157
(5.08) Typ
.200
NC
NC
L
(+)
L
(-)
(2.54) Typ
.100
(0.74) Typ
.029
NO
(15.8) Sq
.622
COM
(2.54) Typ
.100
(1.0) Dia Typ
.039
(5.08)
.200
Note: Order adaptors separately.
AT9410 Splash Cover for Panel Seal
Lid
Materials:
Lid: Polyvinyl chloride
(PVC loses pliability below 0°C/32°F)
Base: Polyethylene
O-ring: NBR
Base
O-ring Supplied with
Panel Seal Switch
O-ring Supplied with
AT9410 Splash Cover
Recommended Panel Thickness:
.039” ~ .138” (1.0mm ~ 3.5mm)
(21.0) Dia
.827
(10.6)
.417
(31.3) Dia
1.232
(7.8)
.307
(3.0)
.118
(1.6)
.063
(23.0) Dia
.906
(22.0) Dia
.866
(31.3) Dia
1.232
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
(0.5)
.020
03-07
Standard Size Pushbuttons
Series LB
ASSEMBLY INSTRUCTIONS
Cut Corner
Round & Rectangular
Match clip on cap assembly with
receptacle inside switch.
C
.
.C
N
3 25
A
3
K
S
5 C
-1 5V A C
LBA 12 0V A
N
.C
.
Projection
N .O .
Rubber Seal
C
Projection
Notch
Square
Match projection (C) on cap assembly
with groove (C) inside switch.
Panel Seal
Match projection on cap assembly
with notch inside switch.
Panel Seal
Bushing Mount
Snap-in Mount
Snap-in clip holds all switches firmly
in place. To mount round switch,
match the antirotation projection
on switch with
guide cut in
panel. Snap Projection
into panel
cutout.
Panel
Insert switch from the front of the panel
with the o-ring between the built-in
bezel and the panel. Install mounting
nut AT075 (supplied
with switch) from the
Bezel
rear of the panel.
O-ring
Overtightening
mounting nut may
damage the switch
housing.
AT109
Cap Extractor
AT112
Socket Wrench
Panel
Mounting Nut
LEGENDS
LM
Easily create and submit your own legends using our new on-line Legend Maker.
Visit www.nkkswitches.com
For other legend support options, customers may either contact the factory and request the LB Legend Packet,
or utilize the general information and basic specifications presented below.
Suggested Printable Area for LB Lens
(0.76) Typ
.030
T
AR
ST
Recommended Methods:
Laser Etch on clear lens;
Screen Print or Pad Print on lens.
Epoxy based ink is recommended.
(11.68)
.460
(11.68) Sq
.460
(13.2) Sq
.520
(0.76) Typ
.030
(17.48) Dia
.688
(19.0) Dia
.748
(0.76) Typ
.030
(17.88)
.704
(13.2)
.520
(0.76) Typ
.030
(19.4)
.764
Shaded areas are printable areas.
Additional Method
Additional method for legends is engraving the cap. Maximum depth for engraving is .012” (0.3mm) on the cap lens.
Enamel paint is recommended to fill the engraved area.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com