Ordering information Rugged PCB type LEA100F LEA 100 1 2 F 3 -5 Recommended Noise Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *5 -O 4 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current J2:Mini terminal block R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LEA100F-3R3-Y LEA100F-5 LEA100F-9 LEA100F-12 LEA100F-15 LEA100F-18 LEA100F-24 LEA100F-24-H LEA100F-30 LEA100F-48 66 100 103.5 102 100.5 100.8 103.2 103.2 105 105.6 3.3V 20A 5V 20A 9V 11.5A 12V 8.5A 15V 6.7A 18V 5.6A 24V 4.3A 24V 4.3(5.0)A 30V 3.5A 48V 2.2A SPECIFICATIONS MODEL VOLTAGE[V] LEA CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] *1 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] -10 - 0C *2 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C DRIFT[mV] *3 START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC *4 INPUT-FG OUTPUT-RC-FG *4 OUTPUT-RC *4 OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] LEA100F-3R3-Y LEA100F-5 LEA100F-9 LEA100F-12 LEA100F-15 LEA100F-18 LEA100F-24 LEA100F-24-H AC85 - 264 1f or DC120 - 370 1.0 1.4typ 0.5 0.7typ 50/60 (47 - 63) or DC 71typ 75typ 79typ 79typ 79typ 81typ 81typ 81typ 73typ 78typ 81typ 81typ 82typ 83typ 84typ 84typ 0.98typ 0.99typ 0.92typ 0.94typ 15typ (Io=100%) (At cold start) (Ta=25 C) 30typ (Io=100%) (At cold start) (Ta=25 C) 0.75max (60Hz, According to IEC60950 and DEN-AN) 3.3 5 9 12 15 18 24 24 20 20 11.5 8.5 6.7 5.6 4.3 4.3 (Peak 5.0) 20max 20max 36max 48max 60max 72max 96max 96max 40max 40max 100max 100max 120max 120max 150max 150max 80max 80max 120max 120max 120max 120max 120max 120max 140max 140max 160max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 150max 150max 160max 160max 180max 180max 180max 180max 180max 180max 50max 50max 90max 120max 150max 180max 240max 240max 60max 60max 120max 150max 180max 200max 290max 290max 20max 20max 36max 48max 60max 72max 96max 96max 500max (ACIN 100V, Io=100%) 20typ (Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional:t10%) 3.25 - 3.35 4.9 - 5.3 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 62X35X222mm (WXHXD) /380g max (without chassis and cover) Convection *1 Peak load for 10 sec. or less is acceptable if the total wattage is less than the rated wattage. *2 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, E-22 *4 *5 * * with the input voltage held constant at the rated input/output. Applicable when remote control (optional) is added. ( ):peak current. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LEA100F-30 LEA100F-48 82typ 85typ 83typ 85typ 30 3.5 120max 180max 120max 160max 150max 180max 300max 360max 120max 48 2.2 192max 300max 150max 200max 350max 400max 480max 600max 192max 28.5 - 31.5 46.0 - 50.0 LEA100F External view CN3 Connector for Remote Voltage adjust (optional) 72 13 23 11 Output(+) CN2 CN1 5 C119 Output(-) 4-M4 Mounting Hole 4.5 CN2 45-+0.5 FG AC(N) AC(L) 25-+0.5 62 RC(-) RC(+) 8 235-+0.5 2-º4.5 Mounting Hole CN1 52-+0.5 4-º3.5 34.5 Name plate 36 ON/OFF (optional) 5 212-+0.5 222 252 235-+0.5 8 (Lead) 3max 45 4.5 32 2-M4 Mounting Hole 20 15 º4.5 PCB t=1.6 PIN CONNECTION I / O Connector Mating Connector CN1 B3P5-VH VHR-5N CN2 B8P-VH VHR-8N CN3 B2B-XH-A XHP-2 Terminal Chain : SVH-21T-P1.1 Loose: BVH-21T-P1.1 Chain : SVH-21T-P1.1 Loose: BVH-21T-P1.1 Chain : SXH-001T-P0.6 Loose: BXH-001T-P0.6 (Mfr: J.S.T.) ¶Weight: 380g or less (Without chassis and cover) ¶Tolerance: t1 ¶Dimensions in mm. ¶PCB Material: Glass composite (CEM3) ¶Chassis and cover is optional. ¶Chassis and cover is not available to remote ON/OFF unit. ¶Mounting torque: 1.5N · m(16kgf · cm)max Optional Pin No. Input 1 AC(L) 2 CN1 3 AC(N) 4 5 FG Pin No. Output 1~4 Pin No. Remote ON/OFF -V CN2 1 RC(+) 2 RC(-) CN3 5~8 +V ¶Keep drawing current per pin below 5A for CN2 Performance data ¡RISE TIME & FALL TIME (LEA100F-5) ¡EFFICIENCY (LEA100F-5) 80 78 EFFICIENCY 76 DC Output ACIN 100V Io=100% AC Input 74 72 Load factor100% Load factor 50% 70 68 60 50ms/DIV ¡INPUT HARMONIC CURRENT (LEA100F-5) 140 180 220 INPUT VOLTAGE 260 300 V ¡INPUT HARMONIC CURRENT (LEA100F-5) 10 10 HARMONIC CURRENT Load factor 100% Input voltage AC 100V 1 Harmonic current standard class A (at odd number) A Harmonic current standard class A (at odd number) A HARMONIC CURRENT 100 0.1 0.01 1 Load factor 100% Input voltage AC 230V 0.1 0.01 0.001 0.001 0 10 20 30 0 40 HARMONIC ORDER 10 20 Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ Änderungen vorbehalten / subject to change without notice 30 40 HARMONIC ORDER ■ ■ ■ E-23 LEA