General Purpose Relays
Miniature Power Relay LN / LNH
I
1 pole 10 A / 16 A, 1 CO or 1 NO contact
I
High performance 10 A version (LN1)
I
16 A High capacity version available (LN3)
I
Version for HOT-applications (LNH)
I
Flux proof
I
Plastic materials according to IEC60335-1 (domestic appliances)
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0424
Applications
F0278-A
Domestic appliances
Approvals
V
REG.-Nr. 40004596, Z E214025
Technical data of approved types on request
Contact data
LN1
LN3
LNH
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 4 s, df 10%
Contact material
1 CO or 1 NO 1 CO or 1 NO 1 CO or 1 NO
single contact
micro-disconnection
10 A
16 A1)
10 A
240/400 VAC 240/400 VAC 240/400 VAC
2500 VA
4000 VA
2500 VA
35 A
35 A
35 A
AgSnO2
AgSnO2
AgSnO2
(AgCdO)
Mechanical endurance
10x106 cycles
Rated frequency of operation with / without load
30/300 min-1
Contact ratings
Type
Load
LN1
10 A, 250V, 85 °C, resistive, EN61810-1
LN3
16 A, 250V, 85 °C, resistive, EN61810-1
LNH NO 10 A, 250V, 105 °C, resistive, EN61810-1
LNH NO 8 A, 250V, 105 °C, resistive, EN61810-1
1)
For 16 A at 85°C: coil power reduction to 50% necessary
For 16A with 100% coil power: max. ambient temperature 75°C
For 100% coil power at 85°C: max. contact current 15A
Coil data
LN1
Rated coil voltage range DC coil
6...48 VDC
Coil power DC coil
typ. 400 mW
Operative range
2
Operative voltage range, % of rated coil voltage
Coil insulation system according UL1446
class F
Cycles
250x103
50x103 1)
200x103
250x103
LN3
LNH
6...48 VDC
typ. 400 mW
2
6...48 VDC
typ. 400 mW
class F
90 - 110%
class F
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
006
6
4.2
0.6
90+10%
400
009
9
6.3
0.9
202+10%
401
012
12
8.4
1.2
360+10%
400
024
24
16.8
2.4
1440+10%
400
036
36
25.2
3.6
3240+10%
400
048
48
33.6
4.8
5760+10%
400
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Miniature Power Relay LN / LNH (Continued)
Insulation
LN1
Dielectric strength coil-contact circuit
open contact circuit
Clearance / creepage coil-contact circuit
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
open contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
Other data
LN3
LNH
PCB layout / terminal assignment
Bottom view on solder pins
2000 Vrms
1000 Vrms
W 2,5/2,5 mm
IIIa
CTI 325
basic
functional
250 V
2
240 V
II
LN1
S0260-AN
LN3
LNH
RoHS - Directive 2002/95/EC
compliant per product date code 0424
Flammability class according to UL94
V-0
V-0
V-0
For WG version: GWFI to IEC 60695-2-12
850°C
850°C
850°C
GWIT to IEC 60695-2-13
775°C
775°C
775°C
Ambient temperature range
-40...85°C -40...75 (85)°C -40...105°C
Operate- / release time
typ. 10/5 ms
Vibration resistance (function), NO / NC contact
>14 / 8 g, 30...400 Hz
Shock resistance (destruction)
100 g
Category of protection
RTII - flux proof
Mounting
PCB
Resistance to soldering heat flux proof
270°C / 10 s
Relay weight
12 g
Packaging unit
25/1000 pcs
S0260-AB
S0260-AC
Dimensions
S0486-A
2
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Miniature Power Relay LN / LNH (Continued)
Product key
L N
Type
Version
1 10 A, 85°C
H 10 A, 105°C
Contact configuration
1 1 CO contact
Contact material
0 AgCdO
Coil
006
6 VDC
009
9 VDC
012
12 VDC
Product key
LN133006
LN133009
LN133012
LN133024
LN133036
LN133048
LN113006
LN113009
LN113012
LN113024
LN113036
LN113048
LNH33006
LNH33009
LNH33012
LNH33024
LNH33036
LNH33048
LNH13006
LNH13009
LNH13012
LNH13024
LNH13036
LNH13048
3
16 A, 85°C
3
1 NO contatct
3
AgSnO2
024
036
Version
LN1
10 A
85°C
24 VDC
36 VDC
Cont. material
AgSnO2
Cont.configuration
1 NO contact
1 CO contact
LNH
10 A
105°C
1 NO contact
1 CO contact
Coil
6 VDC
9 VDC
12 VDC
24 VDC
36 VDC
48 VDC
6 VDC
9 VDC
12 VDC
24 VDC
36 VDC
48 VDC
6 VDC
9 VDC
12 VDC
24 VDC
36 VDC
48 VDC
6 VDC
9 VDC
12 VDC
24 VDC
36 VDC
48 VDC
Part number
0-1721249-1
0-1721249-2
0-1721249-3
0-1721249-4
0-1721249-5
0-1721249-6
0-1721249-7
0-1721249-8
0-1721249-9
1-1721249-0
1-1721249-2
1-1721249-3
0-1721253-2
0-1721253-3
0-1721253-4
0-1721253-5
0-1721253-6
0-1721253-7
0-1721253-9
1-1721253-0
1-1721253-1
1-1721253-2
1-1721253-3
1-1721253-4
3
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
Similar pages